Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39363418

RESUMEN

BACKGROUND: Biventricular pacing (BIV) is the gold standard for cardiac resynchronization therapy (CRT). Thirty percent of patients do not respond to CRT. Conduction system pacing (CSP) represents a viable alternative. Interventricular conduction delay (IVCD), as electrical desynchrony marker, is a CRT response predictor. The aim of this study was to determine the incidence of CRT responders by selecting the best approach between BIV and CPS based on intraoperative IVCD measurement in patients with HFrEF and LBBB. METHODS: Ninety-six patients were randomly assigned in a 1:1 ratio to either a standard BIV group(control group, CG) or a group where the CRT approach was determined based on IVCD evaluation(study group, SG). If the right ventricular sensed electrogram (RVs)-left ventricular sensed electrogram (LVs) interval was ≥100 ms, the lead was left in its original position; otherwise, the LV lead was removed, and CSP was performed instead. Clinical, EKG, and echocardiographic features have been assessed pre- and 6 months post-implant. Echocardiographic and clinical responder were evaluated. RESULTS: Thirty-seven percent of patients in the SG underwent CSP, as the operative algorithm. The incidence of CRT responders was significantly higher in the SG (echocardiographic criterion: 92.5% vs. 69.8%, p:.009; clinical criterion 87.5% vs. 62.8%, p:.014). The SG showed a significantly greater difference in EF between pre- and post-implant as well as reduced end-diastolic and systolic volumes. Univariate and multivariate regression analysis indicated that enrollment in the SG was the only factor associated with CRT response. CONCLUSION: Intraoperative assessment of IVCD could help determine the optimal CRT approach between BIV and CSP, leading to a significant improvement in the rate of CRT responders.

2.
ESC Heart Fail ; 10(5): 2853-2864, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37415291

RESUMEN

AIMS: The presence of anti-human leucocyte antigen (HLA) antibodies has been implicated in a higher incidence of complications as well as mortality rate in heart transplantation. The aim of the study was to identify through non-invasive parameters early signs of myocardial dysfunction in the presence of anti-HLA antibodies but without evidence of antibody-mediated rejection (AMR) and its possible prognostic impact. METHODS AND RESULTS: A total of 113 heart-transplanted patients without acute cellular rejection (ACR) and AMR or cardiac allograft vasculopathy (CAV) were prospectively enrolled and divided into two groups ['HLA+' (50 patients) and 'HLA-' (63 patients)], based on the presence of anti-HLA antibodies. Each patient was followed for 2 years after the enrolment, recording episodes of AMR, ACR, CAV, and mortality. Clinical characteristics were similar between the two groups. Among laboratory data, N-terminal pro-B-type natriuretic peptide and high-sensitivity cardiac troponin values were significantly higher in the presence of anti-HLA antibodies (P < 0.001 and P = 0.003, respectively). The echocardiographic parameters that showed a statistically significant difference between the two groups were deceleration time of E wave (DecT E, P < 0.001), left ventricular global longitudinal strain (P < 0.001), tricuspid annular plane systolic excursion (P = 0.011), tricuspid S' wave (P = 0.002), and free wall right ventricular longitudinal strain (fwRVLS, P = 0.027), whereas left atrial strain did not differ significantly (P = 0.408). Univariate analysis showed that anti-HLA antibodies were associated with the development of CAV at both 1 and 2 year follow-up [odds ratio (OR) 11.90, 95% confidence interval (CI) 1.43-90.79, P = 0.022 and OR 3.37, 95% CI 1.78-9.67, P = 0.024, respectively]. Bivariate analysis demonstrated that both fwRVLS and DecT E were predictors of CAV development independently from HLA status. CONCLUSIONS: The presence of circulating anti-HLA antibodies is correlated with a mild cardiac dysfunction, even in the absence of AMR, and CAV development. Interestingly, reduced values of DecT E and fwRVLS were predictors of future development of CAV, independently from anti-HLA antibody.


Asunto(s)
Trasplante de Corazón , Humanos , Trasplante de Corazón/efectos adversos , Trasplante de Corazón/métodos , Anticuerpos , Pronóstico , Rechazo de Injerto/diagnóstico , Ecocardiografía
3.
Front Cardiovasc Med ; 9: 827237, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35321100

RESUMEN

Background: Cases of myocarditis and myopericarditis after mRNA COVID-19 vaccines have been reported, especially after the second dose and in young males. Their course is generally benign, with symptoms onset after 24-72 h from the dose. Case Summary: We report two cases of myopericarditis after the second dose of the mRNA-1273 COVID-19 vaccine in two young males. Both the patients were administered the mRNA-1273 COVID-19 vaccine from the same batch on the same day and experienced fever on the same day of the vaccine, and symptoms consisted of myopericarditis 3 days after the dose. Discussion: Myopericarditis is usually considered an uncommon adverse reaction after various vaccinations, reported also after the mRNA COVID-19 vaccine. Several explanations have been proposed, including an abnormal activation of the immune system leading to a pro-inflammatory cascade responsible for myocarditis development. Both patients experienced the same temporal onset as well as the same symptoms, it is also useful to underscore that both vaccines belonged to the same batch of vaccines. However, despite these cases, vaccination against COVID-19 far outweighs the risk linked to COVID-19 infection and remains the best option to overcome this disease.

4.
Postgrad Med J ; 97(1145): 180-184, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32820084

RESUMEN

The coronavirus disease of 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV2), has been rapidly escalating, becoming a relevant threat to global health. Being a recent virus outbreak, there are still no available therapeutic regimens that have been approved in large randomised trials and so patients are currently being treated with multiple drugs. This raises concerns regarding drug interaction and their implication in arrhythmic burden. In fact, two of the actually used drugs against SARS-CoV2, such as chloroquine and the combination lopinavir/ritonavir, might determine a QT (the time from the start of the Q wave to the end of the T wave) interval prolongation and they show several interactions with antiarrhythmic drugs and antipsychotic medications, making them prone to an increased risk of developing arrhythmias. This brief review focuses the attention on the most relevant drug interactions involving the currently used COVID-19 medications and their possible association with cardiac rhythm disorders, taking into account also pre-existing condition and precipitating factors that might additionally increase this risk. Furthermore, based on the available evidence and based on the knowledge of drug interaction, we propose a quick and simple algorithm that might help both cardiologists and non-cardiologists in the management of the arrhythmic risk before and during the treatment with the specific drugs used against SARS-CoV2.


Asunto(s)
Antirreumáticos/efectos adversos , Antivirales/efectos adversos , Tratamiento Farmacológico de COVID-19 , Síndrome de QT Prolongado/inducido químicamente , Adenosina Monofosfato/efectos adversos , Adenosina Monofosfato/análogos & derivados , Alanina/efectos adversos , Alanina/análogos & derivados , Anticuerpos Monoclonales Humanizados/efectos adversos , Arritmias Cardíacas/inducido químicamente , Cloroquina/efectos adversos , Combinación de Medicamentos , Interacciones Farmacológicas , Electrocardiografía , Insuficiencia Cardíaca , Humanos , Hidroxicloroquina/efectos adversos , Hipoxia , Inflamación , Lopinavir/efectos adversos , Miocarditis , Miocardio , Factores Desencadenantes , Receptores de Interleucina-6/antagonistas & inhibidores , Síndrome de Dificultad Respiratoria , Ribavirina/efectos adversos , Ritonavir/efectos adversos , SARS-CoV-2 , Desequilibrio Hidroelectrolítico
5.
Echocardiography ; 33(3): 398-405, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26493278

RESUMEN

BACKGROUND: This study aimed at exploring the correlation of left atrial longitudinal function by speckle tracking echocardiography (left atrial strain) and Doppler measurements (E/E' ratio) with direct measurements of left ventricular (LV) end-diastolic pressure (LVEDP) in patients stratified for different values of ejection fraction. METHODS: The study population was 80 stable patients with sinus rhythm undergoing cardiac catheterization. This population was selected in order to have four groups of 20 patients each with different LV ejection fraction (>55%, 45-54%, 30-44%, and <30%). LVEDP was obtained during cardiac catheterization; peak atrial longitudinal strain (PALS) and mean E/E' ratio were measured in all subjects. RESULTS: Similar correlations with LVEDP of global PALS and E/E' ratio were recorded in patients with preserved (r = -0.79 vs. r = 0.72, respectively; P < 0.0001 for both) or mildly reduced ejection fraction (r = -0.75 vs. r = 0.73, respectively; P < 0.0001 for both). A closer correlation of global PALS compared to E/E' ratio was evident in patients with moderate (r = -0.78 P < 0.0001; vs. r = 0.47 P = 0.01, respectively) and severe reduction (r = -0.74 P < 0.0001; vs. r = 0.19 ns, respectively) of LV ejection fraction. In multivariate analysis of all measurements, global PALS emerged as a determinant of the LVEDP, independent on other confounding factors and, with the cutoff value of 18.0% presented the best diagnostic accuracy to predict a LVDP above 12 mmHg (AUC 0.87). CONCLUSIONS: In patients with preserved or mildly reduced LV ejection fraction, global PALS and mean E/E' ratio presented good correlations with LVEDP. In patients with moderate or severe reduction of ejection fraction, E/E' ratio correlated poorly with invasively obtained LV filling pressures. Global PALS provided an overall better estimation of LV filling pressures.


Asunto(s)
Ecocardiografía Doppler/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología , Presión Ventricular , Anciano , Módulo de Elasticidad , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadística como Asunto , Rigidez Vascular
6.
J Amino Acids ; 2013: 646703, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24319592

RESUMEN

Purpose. Previous studies have underlined the effects of the energy drinks containing caffeine end taurine on the cardiovascular system. The aim of this study was to determine acute changes on echocardiographic parameters assessed by conventional echo-Doppler analysis and by speckle tracking echocardiography after the consumption of an energy drink in a young healthy population. Methods. measurement of blood pressure, electrocardiographic, and echocardiographic examination were performed on 35 healthy subjects (mean age 25 ± 2 years, 16 men), at baseline and one hour after the consumption of a body surface area indexed amount of an energy drink (168 mL/m(2)) containing caffeine (0.03%) and taurine (0.4%). Results. The analysis of left ventricular function showed a significant increase of mean relative values of MAPSE (+11%; P < 0.001), global longitudinal strain (+10%, P = 0.004), and left ventricular twisting (+22%, P < 0.0001) in respect to baseline. Also, right ventricular function parameters appeared significantly increased after energy drink consumption, as TAPSE (+15%, P < 0.0001), global, and free wall right ventricular longitudinal strain (+8%, P = 0.001; +5%, P = 0.1, resp.). Conclusion. In conclusion, the consumption of the ED in our population showed a significant increase of right and left ventricular myocardial function, suggesting a possible positive inotropic effect related to the substances contained therein.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...