ACS Omega ; 9(11): 12553-12563, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38524417

RESUMEN

The UPLC methodology was used to establish a method for determining the qualitative and quantitative content of teneligliptin and remogliflozin tablets in oral solid dose form, as no simultaneous method was available. The developed liquid chromatography method consists of an X-Bridge C18 100 mm × 3.5 mm, 2.1 mm column with an economical 0.2 mL/min flow rate. A wavelength of 248 nm was used for detection, and the temperature of the column compartment was 30 °C. The method was evaluated using a static tool quality by design after it was validated as per the regulations. The data from validation result in linearity for both analytes with a correlation coefficient of more than 0.999. The accuracy data were found from a minimum of 98.1 to a maximum of 100.9. All of the validation results met the acceptance criteria. The stability of the analytical solutions proved for 24 h at bench and refrigerator temperatures. Studies of force degradation proved the stability indicating the nature of the method. A factorial design was used to evaluate the method performance.

2.
Biomed Chromatogr ; 37(9): e5687, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37392152

RESUMEN

Ritonavir and darunavir were examined using a ultra-performance liquid chromatography (UPLC) approach in pharmaceutical dosage forms. The small number of analytical studies that are currently available do not demonstrate the method's stability or nature. The study sought to assess both chemicals using a stability-indicating approach with a relatively short run time. The HSS C18 (100 × 2.1 mm), 2-mm column was used for the chromatographic separation, and isocratic elution was used to achieve this. In the mobile phase, methanol and 0.01 M phosphate buffer (pH 4.0) were included in a 60:40 (v/v) ratio. Throughout the analysis, the flow rate was kept at 0.2 mL min-1 , and a photodiode array detector set to 266 nm was used to find the major components. The proposed method showed a linear response (r2  > 0.999), and the accuracy was between 98.0% and 102.0%. The precision data showed relative standard deviation ≤1.0%. The UPLC method for quantification of ritonavir and darunavir in pharmaceutical dosage forms using a very short run time of under a minute is the subject of the proposed article. To meet current regulatory criteria, the quality by design idea was used in the method performance verification.


Asunto(s)
Síndrome de Inmunodeficiencia Adquirida , Ritonavir , Humanos , Darunavir , Ritonavir/análisis , VIH , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Liquida , Preparaciones Farmacéuticas