RESUMEN
OBJECTIVES: Sacral nerve stimulation (SNS) is a surgical treatment of urinary and fecal incontinence. Despite its clinical efficacy, the mechanisms of action of SNS are still poorly known. This may be related to the use of acute stimulation models. Up to date, no rodent model of chronic SNS implants has been developed. Therefore, the aim of this study was to create a fully implantable and remotely controllable stimulating device to establish an animal model of chronic SNS. MATERIALS AND METHODS: The stimulating device consisted of an implantable pulse generator linked to a platinum electrode. The communication with the device was made through an inductive link which allowed to adjust the stimulation parameters; that is, to turn the device on and off or check the battery status remotely. Rats underwent two surgical procedures. In the first procedure, we achieved chronic sacral stimulation but the implanted electrode was not fixated. In the second procedure, the electrode was fixated in the sacral foramen using dental resin. In both cases, the correct positioning of the electrode was evaluated by computed tomography (CT) imaging and the presence of tail tremor in response to high intensity stimulation. We only tested the function of implanted electrode with fixation using micturition frequency assessment following bipolar or unipolar SNS for three days after recovery. RESULTS: CT imaging showed that implantation of the electrode required fixation as we found that the second surgical procedure yielded a more precise placement of the implanted electrode. The correct placement of implanted electrode observed with imaging was always correlated with a successful tail tremor response in rats, therefore we pursued our next experiments with the second surgical procedure and only assessed the tail tremor response. We found that both bipolar and unipolar SNS reduced micturition frequency. CONCLUSION: This stimulating device provides an efficient method to perform chronic SNS studies in rats.
Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Neuroestimuladores Implantables/tendencias , Tecnología de Sensores Remotos/instrumentación , Sacro/diagnóstico por imagen , Sacro/cirugía , Animales , Terapia por Estimulación Eléctrica/métodos , Masculino , Ratas , Ratas Sprague-Dawley , Tecnología de Sensores Remotos/métodos , Sacro/inervaciónRESUMEN
Motion capture setups are used in numerous fields. Studies based on motion capture data can be found in biomechanical, sport or animal science. Clinical science studies include gait analysis as well as balance, posture and motor control. Robotic applications encompass object tracking. Today's life applications includes entertainment or augmented reality. Still, few studies investigate the positioning performance of motion capture setups. In this paper, we study the positioning performance of one player in the optoelectronic motion capture based on markers: Vicon system. Our protocol includes evaluations of static and dynamic performances. Mean error as well as positioning variabilities are studied with calibrated ground truth setups that are not based on other motion capture modalities. We introduce a new setup that enables directly estimating the absolute positioning accuracy for dynamic experiments contrary to state-of-the art works that rely on inter-marker distances. The system performs well on static experiments with a mean absolute error of 0.15 mm and a variability lower than 0.025 mm. Our dynamic experiments were carried out at speeds found in real applications. Our work suggests that the system error is less than 2 mm. We also found that marker size and Vicon sampling rate must be carefully chosen with respect to the speed encountered in the application in order to reach optimal positioning performance that can go to 0.3 mm for our dynamic study.