Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Sci Rep ; 7(1): 14955, 2017 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-29097676

RESUMEN

Optoelectronic technology has been increasingly driven towards miniaturization. In this regard, maintaining the optical properties of the bulk materials while reducing their size is a critical need. How thin must the film be to preserve the bulk material´s optical absorbance and reflectance characteristics? This is the central question for our study of the in situ electro-assembly broad band optical absorber films of platinum in non-aqueous solution of PtCl4. By reducing the in situ constructed film to sub-visible-wavelength thicknesses, the measured reflectance in the region from the ultraviolet to the infrared remained close to that exhibited by the micrometre-width films. These platinum black films broadly absorb electromagnetic waves at a sub-incident-wavelength thickness owing to their plasmonically increased absorbance cross-section. Simulation of various incident energy electron trajectories gives insights into the electron depth through the porous platinum black of ρ = 1.6 g/cm3 and previews the optical behaviour close to the atomic thickness.

2.
Sci Rep ; 7(1): 1074, 2017 04 21.
Artículo en Inglés | MEDLINE | ID: mdl-28432325

RESUMEN

We present electrochemical and chemical synthesis of platinum black at room temperature in aqueous and non-aqueous media. X-ray analysis established the purity and crystalline nature. The electron micrographs indicate that the nanostructures consist of platinum crystals that interconnect to form porous assemblies. Additionally, the electron micrographs of the platinum black thin layer, which was electrochemically deposited on different metallic and semiconductive substrates (aluminium, platinum, silver, gold, tin-cooper alloy, indium-tin-oxide, stainless steel, and copper), indicate that the substrate influences its porous features but not its absorbance characteristics. The platinum black exhibited a broad absorbance and low reflectance in the ultraviolet, visible, and infrared regions. These characteristics make this material suitable for use as a high-temperature resistant absorber layer for the fabrication of microelectronics.

3.
Rev Sci Instrum ; 86(10): 105002, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26520976

RESUMEN

We report on the development of a three-axis absolute vector magnetometer suited for mobile operation in the Earth's magnetic field. It is based on low critical temperature dc superconducting quantum interference devices (LTS dc SQUIDs) with sub-micrometer sized cross-type Josephson junctions and exhibits a white noise level of about 10 fT/Hz(1/2). The width of superconducting strip lines is restricted to less than 6 µm in order to avoid flux trapping during cool-down in magnetically unshielded environment. The long-term stability of the flux-to-voltage transfer coefficients of the SQUID electronics is investigated in detail and a method is presented to significantly increase their reproducibility. We further demonstrate the long-term operation of the setup in a magnetic field varying by about 200 µT amplitude without the need for recalibration.

4.
Rev Sci Instrum ; 85(5): 054702, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24880390

RESUMEN

A new type of high functionality, fast, compact, and easy programmable arbitrary waveform generator for low noise physical measurements is presented. The generator provides 7 fast differential waveform channels with a maximum bandwidth up to 200 MHz frequency. There are 6 fast pulse generators on the generator board with 78 ps time resolution in both duration and delay, 3 of them with amplitude control. The arbitrary waveform generator is additionally equipped with two auxiliary slow 16 bit analog-to-digital converters and four 16 bit digital-to-analog converters for low frequency applications. Electromagnetic shields are introduced to the power supply, digital, and analog compartments and with a proper filter design perform more than 110 dB digital noise isolation to the output signals. All the output channels of the board have 50 Ω SubMiniature version A termination. The generator board is suitable for use as a part of a high sensitive physical equipment, e.g., fast read out and manipulation of nuclear magnetic resonance or superconducting quantum systems and any other application, which requires electromagnetic interference free fast pulse and arbitrary waveform generation.

5.
Opt Lett ; 38(22): 4705-7, 2013 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-24322111

RESUMEN

Laser-produced solid density plasmas are well-known as table-top sources of electromagnetic radiation. Recent studies have shown that energetic broadband terahertz pulses (T rays) can also be generated from laser-driven compact ion accelerators. Here we report the measurement of record-breaking T-Ray pulses with energies no less than 0.7 mJ. The terahertz spectrum has been characterized for frequencies ranging from 0.1-133 THz. The dependence of T-Ray yield on incident laser energy is linear and shows no tendencies of saturation. The noncollinear emission pattern and the high yield reveal that the T rays are generated by the transient field at the rear surface of the solid target.

6.
Phys Rev Lett ; 111(7): 074802, 2013 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-23992071

RESUMEN

We report the observation of subpicosecond terahertz (T-ray) pulses with energies ≥460 µJ from a laser-driven ion accelerator, thus rendering the peak power of the source higher even than that of state-of-the-art synchrotrons. Experiments were performed with intense laser pulses (up to 5×10(19) W/cm(2)) to irradiate thin metal foil targets. Ion spectra measured simultaneously showed a square law dependence of the T-ray yield on particle number. Two-dimensional particle-in-cell simulations show the presence of transient currents at the target rear surface which could be responsible for the strong T-ray emission.

7.
Rev Sci Instrum ; 84(5): 054707, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23742575

RESUMEN

An ultra-wide stopband hairpin bandpass filter with integrated nonuniform transmission lines was designed and fabricated for highly sensitive measurements at cryogenic temperatures down to millikelvin and a frequency range of 10 Hz-10 GHz. The scattering matrices of the filter were characterized at T = 4.2 K. The filter provides a stopband from 10 Hz to 2.2 GHz and from 2.3 GHz to 10 GHz with more than 50 dB and 40 dB of amplitude suppression, respectively. The center frequency of the passband is f0 = 2.25 GHz with a bandwidth Δf = 80 MHz. The maximum insertion loss in the passband is 4 dB. The filter has a 50 Ω input and output impedance, SubMiniature version A connector termination, and significantly reduced form factor. The wide stopband frequency range and narrow passband in conjunction with small dimensions make the filter suitable to use it as a part of a high sensitive readout for superconducting quantum circuits, such as superconducting quantum bits and cryogenic parametric amplifiers.

8.
Phys Rev Lett ; 110(5): 053602, 2013 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-23414019

RESUMEN

We demonstrate amplification of a microwave signal by a strongly driven two-level system in a coplanar waveguide resonator. The effect, similar to the dressed-state lasing known from quantum optics, is observed with a single quantum system formed by a persistent current (flux) qubit. The transmission through the resonator is enhanced when the Rabi frequency of the driven qubit is tuned into resonance with one of the resonator modes. Amplification as well as linewidth narrowing of a weak probe signal has been observed. The stimulated emission in the resonator has been studied by measuring the emission spectrum. We analyzed our system and found an excellent agreement between the experimental results and the theoretical predictions obtained in the dressed-state model.

9.
Rev Sci Instrum ; 83(11): 113106, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23206050

RESUMEN

We show the operation of an optically pumped magnetometer array in a 50 µT magnetic field. The various components for a fully optical and non-magnetic detector unit were constructed and evaluated, from which a prototype unit was assembled with fiber coupled electronics. In this unit the magnetometers were operated using the intensity modulated method and heated with an off-resonant laser. Calculations on the temperature distribution were used to design the magnetometer array. Different magnetometers in such a detector unit were characterized and showed identical performance. Without applying noise reduction schemes, the obtained magnetic field resolution is a factor 2.5 above the shot noise level down to frequencies of about 7 Hz.

10.
Rev Sci Instrum ; 82(10): 104705, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22047315

RESUMEN

An ultra-low-noise one-stage SiGe heterojunction bipolar transistor amplifier was designed for cryogenic temperatures and a frequency range of 10 kHz-100 MHz. A noise temperature T(N) ≈ 1.4 K was measured at an ambient temperature of 4.2 K at frequencies between 100 kHz and 100 MHz for a source resistance of ~50 Ω. The voltage gain of the amplifier was 25 dB at a power consumption of 720 µW. The input voltage noise spectral density of the amplifier is about 35 pV/√Hz. The low noise resistance and power consumption makes the amplifier suitable for readout of resistively shunted DC SQUID magnetometers and amplifiers.

11.
Opt Express ; 19(19): 18593-601, 2011 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-21935228

RESUMEN

We demonstrate the transfer of single photon triggered electrical pulses from a superconducting nanowire single photon detector (SNSPD) to a single flux quantum (SFQ) pulse. We describe design and test of a digital SFQ based SNSPD readout circuit and demonstrate its correct operation. Both circuits (SNSPD and SFQ) operate under the same cryogenic conditions and are directly connected by wire bonds. A future integration of the present multi-chip configuration seems feasible because both fabrication process and materials are very similar. In contrast to commonly used semiconductor amplifiers, SFQ circuits combine very low power dissipation (a few microwatts) with very high operation speed, thus enabling count-rates of several gigahertz. The SFQ interface circuit simplifies the SNSPD readout and enables large numbers of detectors for future compact multi-pixel systems with single photon counting resolution. The demonstrated circuit has great potential for scaling the present interface solution to 1,000 detectors by using a single SFQ chip.

12.
Rev Sci Instrum ; 82(3): 033111, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21456722

RESUMEN

We describe a method for charging atomic vapor cells with cesium and buffer gas. By this, it is possible to adjust the buffer gas pressure in the cells with good accuracy. Furthermore, we present a new design of microfabricated vapor cell arrays, which combine silicon wafer based microfabrication and ultrasonic machining to achieve the arrays of thermally separated cells with 50 mm(3) volume. With cells fabricated in the outlined way, intrinsic magnetic field sensitivities down to 300 fT∕Hz(1∕2) are reached.


Asunto(s)
Magnetismo/instrumentación , Microtecnología/instrumentación , Álcalis/química , Azidas/química , Gases/química , Microscopía , Presión , Volatilización
13.
Phys Rev Lett ; 101(1): 017003, 2008 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-18764145

RESUMEN

We compare the results of ground state and spectroscopic measurements carried out on superconducting flux qubits which are effective two-level quantum systems. For a single qubit and for two coupled qubits we show excellent agreement between the parameters of the pseudospin Hamiltonian found using both methods. We argue that by making use of the ground state measurements the Hamiltonian of N coupled flux qubits can be reconstructed as well at temperatures smaller than the energy level separation. Such a reconstruction of a many-qubit Hamiltonian can be useful for future quantum information processing devices.

14.
J Clin Microbiol ; 45(8): 2684-5, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17581939

RESUMEN

We describe an unusual clinical strain of catalase-negative methicillin-resistant Staphylococcus aureus sensu stricto. Sequence analysis of its catalase gene showed 99.60% identities to the catalase genes of the reference strains. A 5-base deletion, however, led to a shift of the nucleotide reading frame and a loss of the enzymatic activity.


Asunto(s)
Catalasa/genética , Catalasa/metabolismo , Resistencia a la Meticilina , Infecciones Estafilocócicas/microbiología , Staphylococcus aureus/efectos de los fármacos , Staphylococcus aureus/enzimología , Anciano , ADN Bacteriano/química , ADN Bacteriano/genética , Humanos , Masculino , Datos de Secuencia Molecular , Análisis de Secuencia de ADN , Staphylococcus aureus/aislamiento & purificación
15.
Phys Rev Lett ; 98(5): 057004, 2007 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-17358887

RESUMEN

We have realized controllable coupling between two three-junction flux qubits by inserting an additional coupler loop between them, containing three Josephson junctions. Two of these are shared with the qubit loops, providing strong qubit-coupler interaction. The third junction gives the coupler a nontrivial current-flux relation; its derivative (i.e., the susceptibility) determines the coupling strength J, which thus is tunable in situ via the coupler's flux bias. In the qubit regime, J was varied from approximately 45 (antiferromagnetic) to approximately -55 mK (ferromagnetic); in particular, J vanishes for an intermediate coupler bias. Measurements on a second sample illuminate the relation between two-qubit tunable coupling and three-qubit behavior.

16.
Phys Rev Lett ; 96(4): 047006, 2006 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-16486877

RESUMEN

We present the first experimental results on a device with more than two superconducting qubits. The circuit consists of four three-junction flux qubits, with simultaneous ferro- and antiferromagnetic coupling implemented using shared Josephson junctions. Its response, which is dominated by the ground state, is characterized using low-frequency impedance measurement with a superconducting tank circuit coupled to the qubits. The results are found to be in excellent agreement with the quantum-mechanical predictions.

17.
Phys Rev Lett ; 93(3): 037003, 2004 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-15323858

RESUMEN

We have studied the low-frequency magnetic susceptibility of two inductively coupled flux qubits using the impedance measurement technique (IMT), through their influence on the resonant properties of a weakly coupled high-quality tank circuit. In a single qubit, an IMT dip in the tank's current-voltage phase angle at the level anticrossing yields the amplitude of coherent flux tunneling. For two qubits, the difference (IMT deficit) between the sum of single-qubit dips and the dip amplitude when both qubits are at degeneracy shows that the system is in a mixture of entangled states (a necessary condition for entanglement). The dependence on temperature and relative bias between the qubits allows one to determine all the parameters of the effective Hamiltonian and equilibrium density matrix, and confirms the formation of entangled eigenstates.

18.
Phys Rev Lett ; 91(9): 097906, 2003 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-14525214

RESUMEN

Under resonant irradiation, a quantum system can undergo coherent (Rabi) oscillations in time. We report evidence for such oscillations in a continuously observed three-Josephson-junction flux qubit, coupled to a high-quality tank circuit tuned to the Rabi frequency. In addition to simplicity, this method of Rabi spectroscopy enabled a long coherence time of about 2.5 micros, corresponding to an effective qubit quality factor approximately 7000.

19.
Phys Rev Lett ; 86(23): 5369-72, 2001 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-11384500

RESUMEN

We have measured the current-phase relationship I(varphi) of symmetric 45 degrees YBa2Cu3O7-x grain boundary Josephson junctions. Substantial deviations of the Josephson current from conventional tunnel-junction behavior have been observed: (i) The critical current exhibits, as a function of temperature T, a local minimum at a temperature T*. (ii) At T approximately T*, the first harmonic of I(phi) changes sign. (iii) For T

20.
Med Microbiol Immunol ; 189(1): 7-11, 2000 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11034552

RESUMEN

Comparative sequence analysis of a 423-bp segment of the gyrA gene including a region homologous to the quinolone resistance-determining region (QRDR) of other species was evaluated as a novel typing method for Legionella strains. The study was performed with 29 reference strains representing 11 different Legionella species, with various serogroups, and with 13 clinical isolates of L. pneumophila. Pulsed-field gel electrophoresis and serotyping were employed for comparison of the clinical isolates. QRDR sequencing proved to be a highly discriminative tool for typing Legionellae, and permitted identification of species, serogroups and even different strains within serogroup 1. None of the isolates were resistant to quinolones in vitro and this correlated with dissence of mutations in the QRDR region. The data show that comparative sequence analysis of a short fragment of the gyrA gene is a potentially useful tool for typing of Legionella beyond the serogroup level. It is anticipated that mutations of the QRDR may arise in Legionella as a consequence of the introduction of quinolones as the agents of choice for the treatment of infections with this agent in immunocompromised patients. The employment of QRDR-typing maybe helpful in uncovering such mutations.


Asunto(s)
ADN-Topoisomerasas de Tipo II/genética , Genes Bacterianos , Legionella/clasificación , 4-Quinolonas , Antiinfecciosos/farmacología , Girasa de ADN , ADN Bacteriano/análisis , Electroforesis en Gel de Campo Pulsado , Humanos , Legionella/efectos de los fármacos , Legionella/genética , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...