Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Clin Microbiol ; 56(6)2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29618499

RESUMEN

The ability of next-generation sequencing (NGS) technologies to detect low frequency HIV-1 drug resistance mutations (DRMs) not detected by dideoxynucleotide Sanger sequencing has potential advantages for improved patient outcomes. We compared the performance of an in vitro diagnostic (IVD) NGS assay, the Sentosa SQ HIV genotyping assay for HIV-1 genotypic resistance testing, with Sanger sequencing on 138 protease/reverse transcriptase (RT) and 39 integrase sequences. The NGS assay used a 5% threshold for reporting low-frequency variants. The level of complete plus partial nucleotide sequence concordance between Sanger sequencing and NGS was 99.9%. Among the 138 protease/RT sequences, a mean of 6.4 DRMs was identified by both Sanger and NGS, a mean of 0.5 DRM was detected by NGS alone, and a mean of 0.1 DRM was detected by Sanger sequencing alone. Among the 39 integrase sequences, a mean of 1.6 DRMs was detected by both Sanger sequencing and NGS and a mean of 0.15 DRM was detected by NGS alone. Compared with Sanger sequencing, NGS estimated higher levels of resistance to one or more antiretroviral drugs for 18.2% of protease/RT sequences and 5.1% of integrase sequences. There was little evidence for technical artifacts in the NGS sequences, but the G-to-A hypermutation was detected in three samples. In conclusion, the IVD NGS assay evaluated in this study was highly concordant with Sanger sequencing. At the 5% threshold for reporting minority variants, NGS appeared to attain a modestly increased sensitivity for detecting low-frequency DRMs without compromising sequence accuracy.


Asunto(s)
Farmacorresistencia Viral/genética , VIH-1/genética , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Mutación/genética , Fármacos Anti-VIH/uso terapéutico , Genotipo , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/virología , Integrasa de VIH/genética , Transcriptasa Inversa del VIH/genética , Humanos , Pruebas de Sensibilidad Microbiana , ARN Viral/genética , Juego de Reactivos para Diagnóstico , Carga Viral
2.
PLoS One ; 11(12): e0168074, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27936225

RESUMEN

BACKGROUND: Control and elimination of human African trypanosomiasis (HAT) can be accelerated through the use of diagnostic tests that are more accurate and easier to deploy. The goal of this work was to evaluate the immuno-reactivity of antigens and identify candidates to be considered for development of a simple serological test for the detection of Trypanosoma brucei gambiense or T. b. rhodesiense infections, ideally both. METHODOLOGY/PRINCIPAL FINDINGS: The reactivity of 35 antigens was independently evaluated by slot blot and ELISA against sera from both T. b. gambiense and T. b. rhodesiense infected patients and controls. The antigens that were most reactive by both tests to T. b. gambiense sera were the membrane proteins VSG LiTat 1.3, VSG LiTat 1.5 and ISG64. Reactivity to T. b. rhodesiense sera was highest with VSG LiTat 1.3, VSG LiTat 1.5 and SRA, although much lower than with T. b. gambiense samples. The reactivity of all possible combinations of antigens was also calculated. When the slot blot results of 2 antigens were paired, a VSG LiTat 1.3- ISG75 combination performed best on T. b. gambiense sera, while a VSG LiTat 1.3-VSG LiTat 1.5 combination was the most reactive using ELISA. A combination of SRA and either VSG LiTat 1.3 or VSG LiTat 1.5 had the highest reactivity on T. b. rhodesiense sera according to slot blot, while in ELISA, pairing SRA with either GM6 or VSG LiTat 1.3 yielded the best results. CONCLUSIONS: This study identified antigens that were highly reactive to T. b. gambiense sera, which could be considered for developing a serological test for gambiense HAT, either individually or in combination. Antigens with potential for inclusion in a test for T. b. rhodesiense HAT were also identified, but because their reactivity was comparatively lower, a search for additional antigens would be required before developing a test for this form of the disease.


Asunto(s)
Antígenos de Protozoos/inmunología , Tripanosomiasis Africana/diagnóstico , Humanos , Inmunoglobulina G/inmunología , Inmunoglobulina M/inmunología , Tripanosomiasis Africana/inmunología
3.
Sci Rep ; 3: 3259, 2013 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-24247282

RESUMEN

Quality controls of serological assays have to contain defined amounts of human antibodies specific for the targeted antigen. A prevailing issue for array-based antigen assays is that dozens of antigens are targeted within the same assay. Commonly different patient sera are combined and optimal pools are empirically identified. Here, we report a mathematical approach how an optimal sample pool composition can be systematically calculated and accurately compiled. The approach was used to compose suitable quality controls for a 71 plex Tuberculosis antigen bead array using a limited number of positive human sera.


Asunto(s)
Inmunoensayo , Inmunoglobulina G/sangre , Algoritmos , Antígenos/inmunología , Proteínas Bacterianas/inmunología , Humanos , Inmunoensayo/normas , Inmunoglobulina G/inmunología , Análisis por Micromatrices/normas , Modelos Teóricos , Mycobacterium tuberculosis/metabolismo , Control de Calidad , Valores de Referencia , Tuberculosis/diagnóstico
4.
J Clin Microbiol ; 51(5): 1367-73, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23390284

RESUMEN

The development of an accurate antigen detection assay for the diagnosis of active tuberculosis (TB) would represent a major clinical advance. Here, we demonstrate that the Mycobacterium tuberculosis Rv1681 protein is a biomarker for active TB with potential diagnostic utility. We initially identified, by mass spectroscopy, peptides from the Rv1681 protein in urine specimens from 4 patients with untreated active TB. Rabbit IgG anti-recombinant Rv1681 detected Rv1681 protein in lysates and culture filtrates of M. tuberculosis and immunoprecipitated it from pooled urine specimens from two TB patients. An enzyme-linked immunosorbent assay formatted with these antibodies detected Rv1681 protein in unconcentrated urine specimens from 11/25 (44%) TB patients and 1/21 (4.8%) subjects in whom TB was initially clinically suspected but then ruled out by conventional methods. Rv1681 protein was not detected in urine specimens from 10 subjects with Escherichia coli-positive urine cultures, 26 subjects with confirmed non-TB tropical diseases (11 with schistosomiasis, 5 with Chagas' disease, and 10 with cutaneous leishmaniasis), and 14 healthy subjects. These results provide strong validation of Rv1681 protein as a promising biomarker for TB diagnosis.


Asunto(s)
Proteínas Bacterianas/orina , Biomarcadores/orina , Mycobacterium tuberculosis/metabolismo , Tuberculosis Pulmonar/diagnóstico , Secuencia de Aminoácidos , Anticuerpos Antibacterianos/inmunología , Antígenos Bacterianos/inmunología , Proteínas Bacterianas/inmunología , Enfermedad de Chagas/orina , Escherichia coli/aislamiento & purificación , Infecciones por Escherichia coli/orina , Humanos , Inmunoglobulina G/inmunología , Leishmaniasis Cutánea/orina , Datos de Secuencia Molecular , Esquistosomiasis/orina
5.
J Infect Dis ; 206(5): 697-705, 2012 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-22732925

RESUMEN

BACKGROUND: Biomarkers of progression from latent Mycobacterium tuberculosis infection to active tuberculosis are needed. We assessed correlations between infection outcome and antibody responses in macaques and humans by high-throughput, proteome-scale serological studies. METHODS: Mycobacterium tuberculosis proteome microarrays were probed with serial sera from macaques representing various infection outcomes and with single-point human sera from tuberculosis suspects. Fluorescence intensity data were analyzed by calculating Z scores and associated P values. Temporal changes in macaque antibody responses were analyzed by polynomial regression. Correlations between human responses and sputum bacillary burden were assessed by quantile and hurdle regression. RESULTS: Macaque outcome groups exhibited distinct antibody profiles: early, transient responses in latent infection and stable antibody increase in active and reactivation disease. In humans, antibody levels and reactive protein numbers increased with bacillary burden. Responses to a subset of 10 proteins were more tightly associated with disease state than reactivity to the broader reactive proteome. CONCLUSIONS: Integration of macaque and human data reveals dynamic properties of antibody responses in relation to outcome and leads to actionable findings for translational research. These include the potential of antibody responses to detect acute infection and preclinical tuberculosis and to identify serodiagnostic proteins for the spectrum of bacillary burden in tuberculosis.


Asunto(s)
Anticuerpos Antibacterianos/biosíntesis , Enfermedades de los Monos/inmunología , Enfermedades de los Monos/microbiología , Mycobacterium tuberculosis/inmunología , Proteoma/inmunología , Tuberculosis/inmunología , Tuberculosis/microbiología , Adulto , Animales , Anticuerpos Antibacterianos/sangre , Biomarcadores/sangre , Humanos , Macaca fascicularis , Persona de Mediana Edad , Análisis por Matrices de Proteínas , Proteómica/métodos , Análisis de Regresión , Estudios Retrospectivos
6.
Clin Chem ; 58(4): 690-8, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22461515

RESUMEN

BACKGROUND: In the search for more powerful tools for diagnoses of endemic diseases in resource-limited settings, we have been analyzing technologies with potential applicability. Increasingly, the process focuses on readily accessible bodily fluids combined with increasingly powerful multiplex capabilities to unambiguously diagnose a condition without resorting to reliance on a sophisticated reference laboratory. Although these technological advances may well have important implications for the sensitive and specific detection of disease, to date their clinical utility has not been demonstrated, especially in resource-limited settings. Furthermore, many emerging technological developments are in fields of physics or engineering, which are not readily available to or intelligible to clinicians or clinical laboratory scientists. CONTENT: This review provides a look at technology trends that could have applicability to high-sensitivity multiplexed immunoassays in resource-limited settings. Various technologies are explained and assessed according to potential for reaching relevant limits of cost, sensitivity, and multiplex capability. Frequently, such work is reported in technical journals not normally read by clinical scientists, and the authors make enthusiastic claims for the potential of their technology while ignoring potential pitfalls. Thus it is important to draw attention to technical hurdles that authors may not be publicizing. SUMMARY: Immunochromatographic assays, optical methods including those involving waveguides, electrochemical methods, magnetorestrictive methods, and field-effect transistor methods based on nanotubes, nanowires, and nanoribbons reveal possibilities as next-generation technologies.


Asunto(s)
Líquidos Corporales/química , Inmunoensayo/métodos , Enfermedades Renales/diagnóstico , Biomarcadores/análisis , Técnicas Biosensibles , Cromatografía de Afinidad , Técnicas Electroquímicas , Humanos , Inmunoensayo/instrumentación , Pruebas de Función Renal , Campos Magnéticos , Técnicas Analíticas Microfluídicas , Nanoestructuras , Dispositivos Ópticos , Sistemas de Atención de Punto , Transistores Electrónicos
7.
EMBO Mol Med ; 4(1): 27-37, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22147526

RESUMEN

Mycolic acids are attractive diagnostic markers for tuberculosis (TB) infection because they are bacteria-derived, contain information about bacterial species, modulate host-pathogen interactions and are chemically inert. Here, we present a novel approach based on mass spectrometry. Quantification of specific precursor → fragment transitions of approximately 2000 individual mycolic acids (MAs) resulted in high analytical sensitivity and specificity. We next used this tool in a retrospective case-control study of patients with pulmonary TB with varying disease burdens from South Korea, Vietnam, Uganda and South Africa. MAs were extracted from small volume sputum (200 µl) and analysed without the requirement for derivatization. Infected patients (70, 19 of whom were HIV+) could be separated from controls (40, 20 of whom were HIV+) with a sensitivity and specificity of 94 and 93%, respectively. Furthermore, we quantified MA species in lung tissue of TB-infected mice and demonstrated effective clearance of MA levels following curative rifampicin treatment. Thus, our results demonstrate for the first time the feasibility and clinical relevance of direct detection of mycobacterial lipids as biomarkers of TB infection.


Asunto(s)
Antibióticos Antituberculosos/uso terapéutico , Ácidos Micólicos/análisis , Rifampin/uso terapéutico , Tuberculosis/diagnóstico , Tuberculosis/tratamiento farmacológico , Animales , Biomarcadores/análisis , Estudios de Casos y Controles , Cromatografía Líquida de Alta Presión , Femenino , Infecciones por VIH/complicaciones , Infecciones por VIH/patología , Humanos , Ratones , Ratones Endogámicos BALB C , Estudios Retrospectivos , Sensibilidad y Especificidad , Espectrometría de Masa por Ionización de Electrospray , Esputo/metabolismo , Tuberculosis/complicaciones
8.
J Proteome Res ; 10(3): 1316-22, 2011 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-21247063

RESUMEN

Based on a single-molecule sensitive fluorescence-linked immunosorbent assay, an analytical platform for the detection of lipoarabinomannan (LAM), a lipopolysaccharide marker of tuberculosis, was established that is about 3 orders of magnitude more sensitive than comparable current ELISA assays. No amplification step was required. Also, no particular sample preparation had to be done. Since individual binding events are detected, true quantification was possible simply by counting individual signals. Utilizing a total internal reflection configuration, unprocessed biological samples (human urine and plasma) to which LAM was added could be analyzed without the requirement of sample purification or washing steps during analysis. Samples containing about 600 antigen molecules per microliter produced a distinct signal. The methodology developed can be employed for any set of target molecules for which appropriate antibodies exist.


Asunto(s)
Antígenos/análisis , Colorantes Fluorescentes/química , Técnicas de Inmunoadsorción , Lipopolisacáridos/análisis , Tuberculosis/inmunología , Humanos , Técnicas de Inmunoadsorción/instrumentación , Lipopolisacáridos/inmunología , Sensibilidad y Especificidad
9.
Proc Natl Acad Sci U S A ; 107(33): 14703-8, 2010 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-20668240

RESUMEN

Considerable effort has been directed toward controlling tuberculosis, which kills almost two million people yearly. High on the research agenda is the discovery of biomarkers of active tuberculosis (TB) for diagnosis and for monitoring treatment outcome. Rational biomarker discovery requires understanding host-pathogen interactions leading to biomarker expression. Here we report a systems immunology approach integrating clinical data and bacterial metabolic and regulatory information with high-throughput detection in human serum of antibodies to the entire Mycobacterium tuberculosis proteome. Sera from worldwide TB suspects recognized approximately 10% of the bacterial proteome. This result defines the M. tuberculosis immunoproteome, which is rich in membrane-associated and extracellular proteins. Additional analyses revealed that during active tuberculosis (i) antibody responses focused on an approximately 0.5% of the proteome enriched for extracellular proteins, (ii) relative target preference varied among patients, and (iii) responses correlated with bacillary burden. These results indicate that the B cell response tracks the evolution of infection and the pathogen burden and replicative state and suggest functions associated with B cell-rich foci seen in tuberculous lung granulomas. Our integrated proteome-scale approach is applicable to other chronic infections characterized by diverse antibody target recognition.


Asunto(s)
Anticuerpos Antibacterianos/inmunología , Proteínas Bacterianas/inmunología , Mycobacterium tuberculosis/inmunología , Proteoma/inmunología , Tuberculosis/inmunología , Anticuerpos Antibacterianos/sangre , Formación de Anticuerpos/inmunología , Antígenos Bacterianos/sangre , Antígenos Bacterianos/inmunología , Proteínas Bacterianas/análisis , Interacciones Huésped-Patógeno/inmunología , Humanos , Mycobacterium tuberculosis/metabolismo , Mycobacterium tuberculosis/fisiología , Proteoma/análisis , Proteómica , Tuberculosis/sangre , Tuberculosis/microbiología
10.
Antivir Ther ; 13(4): 547-54, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18672533

RESUMEN

BACKGROUND: The elimination of hepatitis B virus surface antigen (HBsAg) is the final goal of hepatitis B treatment, but is rarely achieved. As quantitative assays for HBsAg recently became available, we have investigated whether quantitative HBsAg measurements can substitute for hepatitis B virus (HBV) DNA quantification in treatment monitoring. METHODS: Within this study, 23 liver transplant patients and 18 heart transplant recipients were retrospectively analysed. Patients had been treated with famciclovir and/or lamivudine, in addition some had also received adefovir in cases of lamivudine resistance. Quantitative HBsAg and hepatitis B virus e antigen (HBeAg) levels were determined with the Architect assay. HBV DNA levels were determined with different assays available at given time points. RESULTS: We did not find a significant correlation between either HBsAg or HBeAg and HBV DNA levels - both in treated and untreated patients. More importantly, there was no significant concordance between an increase or decrease of HBsAg or HBeAg with HBV DNA. However, the curve and decline of quantitative HBsAg enabled prediction of eventual viral clearance. Eight patients showed a 2 log10 drop of HBsAg levels and eight patients demonstrated a reduction of HBsAg levels below 100 IU/ml; five patients fulfilled both criteria. Three of those five cleared HBsAg and became positive for antibodies against HBsAg. CONCLUSIONS: Quantitative HBsAg and HBeAg cannot substitute for HBV DNA quantification during the assessment of antiviral therapy; however, the decline of HBsAg does predict eventual HBsAg clearance. A 2 log10 drop to below 100 IU/ml is associated with a high likelihood of HBsAg clearance.


Asunto(s)
Antivirales/uso terapéutico , ADN Viral/sangre , Antígenos de Superficie de la Hepatitis B/sangre , Antígenos e de la Hepatitis B/sangre , Virus de la Hepatitis B/efectos de los fármacos , Hepatitis B/tratamiento farmacológico , 2-Aminopurina/análogos & derivados , 2-Aminopurina/uso terapéutico , Famciclovir , Femenino , Trasplante de Corazón/efectos adversos , Hepatitis B/virología , Humanos , Lamivudine/uso terapéutico , Trasplante de Hígado/efectos adversos , Masculino , Valor Predictivo de las Pruebas , Resultado del Tratamiento
12.
Clin Chem Lab Med ; 45(7): 843-50, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17617025

RESUMEN

This workshop discussed the use of pharmacogenomics knowledge in clinical practice. It was organized in three sections: educational needs, definition of industry as a potential trigger, and regulatory aspects. Regarding pharmacogenomics education, it appears that this is truly lacking, except for patients, who are becoming increasingly educated thanks to the media. Regarding administrators, education is mainly a problem of cost. Indeed, even if cost-effective for society on the whole, pharmacogenomic tests will be expensive for hospitals. Physicians are facing an overabundance of information. They must be helped to bridge the gap between knowledge/research and clinical application. Collaboration between the pharmaceutical industry and the diagnostics industry could be one of the triggers. Moreover, there is a lack of qualification of this information, even though some guidelines are being produced. The Food and Drug Administration organizes workshops that often lead to publications on pharmacogenomic education, genomic data aims and development concepts, which can finally be translated into guidelines. Industry can contribute to pharmacogenomic development, not only through research, but also through marketing activities, which would promote the use of pharmacogenomics by physicians. Legal aspects were also considered in terms of the problem of availability and the degree of qualification of commercial drug tests on the market. The Innovative Medicine Initiative was also presented, which is a public-private partnership to create a biomedical research and development leader to benefit patients and society. Finally, a technical report from the Institute for Prospective Technological Studies on the socioeconomic impact of pharmacogenomics in the EU was presented.


Asunto(s)
Industria Farmacéutica , Farmacogenética , Industria Farmacéutica/educación , Industria Farmacéutica/tendencias , Necesidades y Demandas de Servicios de Salud , Humanos , Cooperación Internacional , Farmacogenética/educación , Farmacogenética/métodos , Estados Unidos , United States Food and Drug Administration/legislación & jurisprudencia
13.
J Hepatol ; 46(4): 635-44, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17316869

RESUMEN

BACKGROUND/AIMS: Administration of hepatitis B immunoglobulin (HBIG) initially after liver transplantation of hepatitis B patients is considered important to prevent reinfection reliably. However, dosing schedules differ considerably between centers. We measured HBsAg, anti-HBs and HBV DNA kinetics to create a rational basis for dosing schemes. METHODS: Thirteen patients (group A) received 10,000 IU HBIG in the anhepatic phase followed by 10,000 IU daily until HBsAg became negative, whereas five patients (group B) received 20,000 IU followed by 5000 IU every 30 min. RESULTS: HBsAg levels at time of transplantation ranged from 0.12 to 12,990 IU/ml. Correlations between initial HBsAg and HBIG required to decrease HBsAg below 1 IU/ml were high in groups A and B (r=0.97, p<0.001; r=1.00, p<0.001), as were correlations between initial HBsAg and HBIG required to raise anti-HBs above 1000 IU/l (r=0.94, p<0.001; r=1.00, p<0.001). In 11 HBV DNA-positive patients, DNA levels became negative in seven, and dropped by 2.5 log10 (mean) in the other four patients during immunoglobulin administration. CONCLUSIONS: In conclusion, required HBIG doses to decrease HBsAg and raise anti-HBs are determined by HBsAg levels at time of transplantation, not by HBV DNA levels. Shortened HBIG dosing intervals accelerate HBsAg decrease and anti-HBs increase. HBV DNA decreases rapidly during HBIG administration in most patients.


Asunto(s)
ADN Viral/sangre , Anticuerpos contra la Hepatitis B/sangre , Antígenos de Superficie de la Hepatitis B/sangre , Virus de la Hepatitis B/genética , Inmunoglobulinas/administración & dosificación , Trasplante de Hígado/inmunología , Cuidados Posoperatorios , Adulto , Relación Dosis-Respuesta a Droga , Esquema de Medicación , Femenino , Estudios de Seguimiento , Hepatitis B/prevención & control , Humanos , Inmunización Pasiva , Inmunoglobulinas/uso terapéutico , Cinética , Masculino , Persona de Mediana Edad , Prevención Secundaria
14.
Free Radic Biol Med ; 35(10): 1286-92, 2003 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-14607527

RESUMEN

Treatment of hyperlipidemic patients with the thiol compound N-acetylcysteine (NAC) was previously shown to cause a significant dose-related increase in the high-density lipoprotein (HDL)-cholesterol serum level, suggesting the possibility that its disease-related decrease may result from a diminished thiol concentration and/or thiol/disulfide redox status (REDST) in the plasma. We therefore investigated plasma thiol levels and REDST in normo-/hyperlipidemic subjects with and without coronary heart disease (CHD). The thiol level, REDST, and amino acid concentrations in the plasma and intracellular REDST of peripheral blood mononuclear cells (PBMC) have been determined in 62 normo- and hyperlipidemic subjects. Thirty-three of these subjects underwent coronary angiography, because of clinical symptoms of CHD. All groups of hyperlipidemic patients under test and those normolipidemic individuals with documented coronary stenoses showed a marked decrease in plasma thiol concentrations, plasma and intracellular REDST of PBMCs, and a marked increase in plasma taurine levels. Individual plasma thiol concentrations and plasma REDST were strongly negatively correlated with the serum LDL-cholesterol and positively correlated with the serum HDL-cholesterol level. Together with the earlier report about the effect of NAC on the HDL-cholesterol serum level, our findings suggest strongly that lower HDL-cholesterol serum levels may result from a decrease in plasma thiol level and/or REDST possibly through an excessive cysteine catabolism into taurine.


Asunto(s)
HDL-Colesterol/sangre , Enfermedad Coronaria/sangre , Disulfuros/sangre , Hiperlipidemias/sangre , Oxidación-Reducción , Compuestos de Sulfhidrilo/sangre , Aminoácidos/sangre , Colesterol/sangre , LDL-Colesterol/sangre , Cisteína/sangre , Glutatión/metabolismo , Humanos , Taurina/sangre , Triglicéridos/sangre
15.
Clin Chem Lab Med ; 40(7): 698-704, 2002 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12241017

RESUMEN

Performance characteristics of the Abbott LCx HIV RNA Quantitative Assay (LCx HIV) were established in a multicenter study comparing it with the manual (Amplicor v1.5) and automated (Cobas) ultra-sensitive Roche Amplicor HIV-1 Monitor v1.5, the Bayer Quantiplex HIV RNA 3.0 (bDNA v3.0), and the Organon NucliSens HIV QT 2.0 (NucliSens). Within-run precision of LCx HIV assessed in clinical specimens was SD log10 0.210 at approximately 50 copies/ml, and log10 0.133 at approximately 400 copies/ml. Total precision in a reconstituted type B HIV-1 RNA panel was SD log10 0.380 at 100 copies/ml, and SD log10 0.180 at 1000 copies/ml. Type B HIV-1 RNA sensitivity (1 ml input) assessed at a 50%, 75% and 95% detection rate ranged from 29 to 41, 54 to 75 and 94 to 176 copies/ml, respectively. Overall specificity in HIV seronegative individuals was 99.78%. Linear regression indicated close assay correlations and agreements for measurement of type B HIV-1 RNA. Pearson's correlations and (Log10LCx=aLog10x + b) linear regressions were 0.91 (y=0.892 Log10Amplicor + 0.595), 0.93 (y=0.827 Log10Cobas + 0.969), 0.93 (y=0.951 Log10bDNA + 0.550), and 0.79 (y=0.834 Log10NucliSens + 0.911). LCx HIV was least affected by the genetic variability of HIV-1. LCx HIV detected 99% of non-type B HIV-1 group M samples (subtypes A-G), Amplicor v1.5 detected 96%, and bDNA v3.0 detected 99%. The assays detected 10/11, 1/11 and 8/11, respectively of the HIV-1 group O samples. LCx HIV vs. Amplicor/bDNA Spearman's rank correlations for quantification of non-type B HIV-1 RNA were 0.76/0.84 (A), 0.93/0.93 (C), 0.73/0.99 (D), 0.86/0.98 (E), and 0.40/0.83 (group O). LCx HIV assays consistently detect and quantify type B, non-type B and group O HIV-1 RNA.


Asunto(s)
Síndrome de Inmunodeficiencia Adquirida/diagnóstico , Productos del Gen pol/genética , VIH-1/clasificación , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Síndrome de Inmunodeficiencia Adquirida/sangre , VIH-1/genética , Humanos , ARN Viral/sangre , Juego de Reactivos para Diagnóstico/normas , Reproducibilidad de los Resultados , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/normas , Sensibilidad y Especificidad , Carga Viral/métodos , Productos del Gen pol del Virus de la Inmunodeficiencia Humana
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...