RESUMEN
Purpose: Spatio-temporal variability in clinical fluoroscopy and cine angiography images combined with nonlinear image processing prevents the application of traditional image quality measurements in the cardiac catheterization laboratory. We aimed to develop and validate methods to measure human observer impressions of the image quality. Approach: Multi-frame images of the thorax of a euthanized pig were acquired to provide an anatomical background. The detector dose was varied from 6 to 200 nGy (increments 2×), and 0.6 and 1.0 mm focal spots were used. Two coronary stents with/without 0.5 mm separation and a synthetic right coronary artery (RCA) with hemispherical defects were embedded into the background images as test objects. The quantitative observer ( n = 17 ) performance was measured using a two-alternating forced-choice test of whether stents were separated and by a count of visible right coronary artery defects. Qualitative impressions of noise, spatial resolution, and overall image quality were measured using a visual analog scale (VAS). A paired t -test and multinomial logistic regression model were used to identify statistically significant factors affecting the observer's impression image quality. Results: The proportion of correct detection of stent separation and the number of reported right coronary artery defects changed significantly with detector dose increment in the 6 to 100 nGy ( p < 0.05 ). Although a trend favored the 0.6 versus 1.0 mm focal spot for these quantitative assessments, this was insignificant. Visual analog scale measurements changed significantly with detector dose increments in the range of 24 to 100 nGy and focal spot size ( p < 0.05 ). The application of multinomial logistic regression analysis to observer VAS scores demonstrated sensitivity matching of the paired t -test applied to quantitative observer performance measurements. Conclusions: Both quantitative and qualitative measurements of observer impression of the image quality were sensitive to image quality changes associated with changing the detector dose and focal spot size. These findings encourage future work that uses qualitative image quality measurements to assess clinical fluoroscopy and angiography image quality.
RESUMEN
PURPOSE: A dual-source CT system can be operated in a high-pitch helical mode to provide a temporal resolution of 66 ms, which reduces motion artifacts in CT pulmonary angiography (CTPA). It can also be operated in a multi-energy (ME) mode to provide iodine maps, beneficial in the evaluation of pulmonary embolism (PE). No energy-integrating detector (EID) CT can perform simultaneous ME and high-pitch acquisition. This phantom study aimed to evaluate the ability of a photon-counting-detector (PCD) CT to perform simultaneous high-pitch and ME imaging for CTPA. METHODS: A motion phantom was used to mimic the respiratory motion. Two tubes filled with iodine with intravascular thrombus mimicked by injecting glue within the tubes were placed along with 5, 10, and 15 mg/mL iodine samples, on a motion phantom at 20 and 30 revolutions per minute. Separate high-pitch and ME EID-CT scans and a single high-pitch ME PCD scan were acquired and virtual monoenergetic images and iodine maps reconstructed. Percent thrombus occlusion was measured and compared between static and moving images. RESULTS: When there was motion, EID-CT ME suffered from significant motion artifacts. The measured iodine concentrations with PCD-CT in high-pitch ME were more stable when there was a motion, with a lower standard deviation than EID-CT in ME mode. The estimated percent thrombus occlusion dropped significantly with applied motion on EID-CT, while PCD-CT high-pitch ME mode showed good agreement between measurements on static or moving images. CONCLUSION: PCD-CT with combined ME and high-pitch mode facilitates simultaneous accurate iodine quantification and assessment of intravascular occlusion.
RESUMEN
Apolipoprotein ε4 (APOE4) carriers develop brain metabolic dysfunctions decades before the onset of Alzheimer's disease (AD). A goal of the study is to identify if rapamycin, an inhibitor for the mammalian target of rapamycin (mTOR) inhibitor, would enhance synaptic and mitochondrial function in asymptomatic mice with human APOE4 gene (E4FAD) before they showed metabolic deficits. A second goal is to determine whether there may be genetic-dependent responses to rapamycin when compared to mice with human APOE3 alleles (E3FAD), a neutral AD genetic risk factor. We fed asymptomatic E4FAD and E3FAD mice with control or rapamycin diets for 16 weeks from starting from 3 months of age. Neuronal mitochondrial oxidative metabolism and excitatory neurotransmission rates were measured using in vivo 1H-[13C] proton-observed carbon-edited magnetic resonance spectroscopy, and isolated mitochondrial bioenergetic measurements using Seahorse. We found that rapamycin enhanced neuronal mitochondrial function, glutamate-glutamine cycling, and TCA cycle rates in the asymptomatic E4FAD mice. In contrast, rapamycin enhances glycolysis, non-neuronal activities, and inhibitory neurotransmission of the E3FAD mice. These findings indicate that rapamycin might be able to mitigate the risk for AD by enhancing brain metabolic functions for cognitively intact APOE4 carriers, and the responses to rapamycin are varied by APOE genotypes. Consideration of precision medicine may be needed for future rapamycin therapeutics.
Asunto(s)
Enfermedad de Alzheimer , Apolipoproteína E4 , Ratones Transgénicos , Mitocondrias , Sirolimus , Serina-Treonina Quinasas TOR , Enfermedad de Alzheimer/metabolismo , Enfermedad de Alzheimer/tratamiento farmacológico , Animales , Mitocondrias/metabolismo , Mitocondrias/efectos de los fármacos , Serina-Treonina Quinasas TOR/metabolismo , Ratones , Sirolimus/farmacología , Humanos , Apolipoproteína E4/genética , Apolipoproteína E4/metabolismo , Genotipo , Sinapsis/metabolismo , Sinapsis/efectos de los fármacos , Apolipoproteína E3/genética , Apolipoproteína E3/metabolismo , Masculino , Transmisión Sináptica/efectos de los fármacosRESUMEN
Magnetic resonance imaging plays an important role in characterizing microstructural changes and reorganization after traumatic injuries to the nervous system. In this study, we tested the feasibility of ex-vivo spinal cord diffusion tensor imaging (DTI) in combination with in vivo brain functional MRI to characterize spinal reorganization and its supraspinal association after a hemicontusion cervical spinal cord injury (SCI). DTI parameters (fractional anisotropy [FA], mean diffusion [MD]) and fiber orientation changes related to reorganization in the contused cervical spinal cord were compared to sham specimens. Altered fiber density and fiber directions occurred across the ipsilateral and contralateral hemicords but with only ipsilateral FA and MD changes. The hemicontusion SCI resulted in ipsilateral fiber breaks, voids and vivid fiber reorientations along the injury epicenter. Fiber directional changes below the injury level were primarily inter-hemispheric, indicating prominent below-level cross-hemispheric reorganization. In vivo resting state functional connectivity of the brain from the respective rats before obtaining the spinal cord samples indicated spatial expansion and increased connectivity strength across both the sensory and motor networks after SCI. The consistency of the neuroplastic changes along the neuraxis (both brain and spinal cord) at the single-subject level, indicates that distinctive reorganizational relationships exist between the spinal cord and the brain post-SCI.
Asunto(s)
Médula Cervical , Traumatismos de la Médula Espinal , Ratas , Animales , Imagen de Difusión Tensora/métodos , Médula Cervical/lesiones , Médula Cervical/patología , Traumatismos de la Médula Espinal/patología , Médula Espinal/patología , Imagen por Resonancia MagnéticaRESUMEN
Human diseases may be modeled in animals to allow preclinical assessment of putative new clinical interventions. Recent, highly publicized failures of large clinical trials called into question the rigor, design, and value of preclinical assessment. We established the Stroke Preclinical Assessment Network (SPAN) to design and implement a randomized, controlled, blinded, multi-laboratory trial for the rigorous assessment of candidate stroke treatments combined with intravascular thrombectomy. Efficacy and futility boundaries in a multi-arm multi-stage statistical design aimed to exclude from further study highly effective or futile interventions after each of four sequential stages. Six independent research laboratories performed a standard focal cerebral ischemic insult in five animal models that included equal numbers of males and females: young mice, young rats, aging mice, mice with diet-induced obesity, and spontaneously hypertensive rats. The laboratories adhered to a common protocol and efficiently enrolled 2615 animals with full data completion and comprehensive animal tracking. SPAN successfully implemented treatment masking, randomization, prerandomization inclusion and exclusion criteria, and blinded assessment of outcomes. The SPAN design and infrastructure provide an effective approach that could be used in similar preclinical, multi-laboratory studies in other disease areas and should help improve reproducibility in translational science.
Asunto(s)
Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Femenino , Humanos , Masculino , Ratas , Animales , Ratones , Roedores , Laboratorios , Reproducibilidad de los Resultados , Accidente Cerebrovascular/terapiaRESUMEN
Based on the premise that physical activity/exercise impacts hippocampal structure and function, we investigated if hippocampal metabolites for neuronal viability and cell membrane density (i.e., N-acetyl aspartate (NAA), choline (Cho), creatine (Cr)) were higher in older adults performing supervised exercise compared to following national physical activity guidelines. Sixty-three participants (75.3 ± 1.9 years after 3 years of intervention) recruited from the Generation 100 study (NCT01666340_date:08.16.2012) were randomized into a supervised exercise group (SEG) performing twice weekly moderate- to high-intensity training, and a control group (CG) following national physical activity guidelines of ≥ 30-min moderate physical activity ≥ 5 days/week. Hippocampal body and head volumes and NAA, Cho, and Cr levels were acquired at 3T with magnetic resonance imaging and spectroscopic imaging. Sociodemographic data, peak oxygen uptake (VO2peak), exercise characteristics, psychological health, and cognition were recorded. General linear models were used to assess group differences and associations corrected for age, sex, education, and hippocampal volume. Both groups adhered to their training, where SEG trained at higher intensity. SEG had significantly lower NAA/Cr in hippocampal body than CG (p = 0.04). Across participants, higher training intensity was associated with lower Cho/Cr in hippocampal body (p < 0.001). Change in VO2peak, increasing VO2peak from baseline to 3 years, or VO2peak at 3 years were not associated with hippocampal neurochemicals. Lower NAA/Cr in hippocampal body was associated with poorer psychological health and slightly higher cognitive scores. Thus, following the national physical activity guidelines and not training at the highest intensity level were associated with the best neurochemical profile in the hippocampus at 3 years.
Asunto(s)
Cognición , Imagen por Resonancia Magnética , Humanos , Anciano , Cognición/fisiología , Ejercicio Físico/fisiología , Escolaridad , Hipocampo/metabolismoRESUMEN
Cerebral ischemia and reperfusion initiate cellular events in brain that lead to neurological disability. Investigating these cellular events provides ample targets for developing new treatments. Despite considerable work, no such therapy has translated into successful stroke treatment. Among other issues-such as incomplete mechanistic knowledge and faulty clinical trial design-a key contributor to prior translational failures may be insufficient scientific rigor during preclinical assessment: nonblinded outcome assessment; missing randomization; inappropriate sample sizes; and preclinical assessments in young male animals that ignore relevant biological variables, such as age, sex, and relevant comorbid diseases. Promising results are rarely replicated in multiple laboratories. We sought to address some of these issues with rigorous assessment of candidate treatments across 6 independent research laboratories. The Stroke Preclinical Assessment Network (SPAN) implements state-of-the-art experimental design to test the hypothesis that rigorous preclinical assessment can successfully reduce or eliminate common sources of bias in choosing treatments for evaluation in clinical studies. SPAN is a randomized, placebo-controlled, blinded, multilaboratory trial using a multi-arm multi-stage protocol to select one or more putative stroke treatments with an implied high likelihood of success in human clinical stroke trials. The first stage of SPAN implemented procedural standardization and experimental rigor. All participating research laboratories performed middle cerebral artery occlusion surgery adhering to a common protocol and rapidly enrolled 913 mice in the first of 4 planned stages with excellent protocol adherence, remarkable data completion and low rates of subject loss. SPAN stage 1 successfully implemented treatment masking, randomization, prerandomization inclusion/exclusion criteria, and blinded assessment to exclude bias. Our data suggest that a large, multilaboratory, preclinical assessment effort to reduce known sources of bias is feasible and practical. Subsequent SPAN stages will evaluate candidate treatments for potential success in future stroke clinical trials using aged animals and animals with comorbid conditions.
Asunto(s)
Isquemia Encefálica , Accidente Cerebrovascular , Anciano , Animales , Encéfalo , Isquemia Encefálica/terapia , Estudios de Factibilidad , Humanos , Infarto de la Arteria Cerebral Media/terapia , Masculino , Ratones , Accidente Cerebrovascular/terapiaRESUMEN
Nuclear magnetic resonance (NMR) agents, composed of paramagnetic lanthanide ions (Ln3+) complexed with negatively charged cyclic chelating agents (Che(n+3)-) forming polyanionic lanthanide complexes (LnChen-), perturb sodium-23 (23Na) signals, a phenomenon which depends sodium ions (Na+) exchanging with LnChen-. We analyzed 23Na shiftability and broadening due to hyperfine and bulk magnetic susceptibility (BMS) effects that arise from LnChen- designs using selective Ln3+ ions (i.e., thulium, Tm3+; gadolinium, Gd3+; and europium, Eu3+) and macrocyclics derived from 1,4,7,10-tetraazacyclododecane (cyclen) [i.e., with phosphonate (DOTP8-) and carboxylate (DOTMA4-) arms] and 1,4,7-triazacyclononane (TACN) [i.e., with phosphonate (NOTP6-) arms]. All LnChen- complexes showed downfield shifts, but Gd3+ and Tm3+ agents, respectively, were dominated by BMS and hyperfine effects, in good agreement with theory. While 23Na shiftability and broadening were minimally affected by pH and competing cations (K+, Ca2+, and Mg2+) within physiological ranges, the 23Na shiftability and broadening were most sensitive to LnChen- concentration in relation to the interstitial Na+ level in vivo. Greatest 23Na shiftability and broadening were obtained with Tm3+ and Gd3+ agents, respectively. While BMS contribution to shiftability was most impacted by the number of unpaired electrons on Ln3+, negative charge on LnChen- regulated Na+ exchange for line broadening. In brain tumor models, TmDOTP5- with 23Na-NMR has been used previously to separate Na+ in intracellular, blood, and interstitial pools, while evidence here shows that GdDOTP5- can distinguish Na+ within intracellular and extracellular (i.e., blood and interstitial) pools. Given the biological importance of Na+ in vivo, future macrocyclic designs of LnChen- should be sought for 23Na-NMR biomedical applications.
Asunto(s)
Elementos de la Serie de los Lantanoides , Gadolinio/química , Iones , Elementos de la Serie de los Lantanoides/química , Espectroscopía de Resonancia Magnética , SodioRESUMEN
Chemical exchange saturation transfer (CEST) and biosensor imaging of redundant deviation in shifts (BIRDS) methods differ respectively by detecting exchangeable and nonexchangeable proton signals by magnetic resonance. Because CEST contrast depends on both temperature and pH, simultaneous CEST and BIRDS imaging can be employed to separate these contributions. Here, we test if high-resolution pH imaging in vivo is possible with ratiometric CEST calibrated for temperature variations measured by BIRDS. Thulium- and europium-based DOTA-tetraglycinate agents, TmDOTA-(gly)4- and EuDOTA-(gly)4- , were used for high-resolution pH mapping in vitro and in vivo, using BIRDS for temperature adjustments needed for a more accurate ratiometric CEST approach. Although neither agent showed pH dependence with BIRDS in vitro in the pH range 6 to 8, each one's temperature sensitivity was enhanced when mixed because of increased redundancy. By contrast, the CEST signal of each agent was affected by the presence of the other agent in vitro. However, pH could be measured more accurately when temperature from BIRDS was detected. These in vitro calibrations with TmDOTA-(gly)4- and EuDOTA-(gly)4- enabled high-resolution pH imaging of glioblastoma in rat brains. It was concluded that temperature mapping with BIRDS can calibrate the ratiometric CEST signal from a cocktail of TmDOTA-(gly)4- and EuDOTA-(gly)4- agents to provide temperature-independent absolute pH imaging in vivo.
Asunto(s)
Técnicas Biosensibles , Medios de Contraste , Animales , Técnicas Biosensibles/métodos , Compuestos Heterocíclicos con 1 Anillo , Concentración de Iones de Hidrógeno , Imagen por Resonancia Magnética/métodos , RatasRESUMEN
Paramagnetic agents that utilize two mechanisms to provide physiological information by magnetic resonance imaging (MRI) and magnetic resonance spectroscopic imaging (MRSI) are described. MRI with chemical exchange saturation transfer (CEST) takes advantage of the agent's exchangeable protons (e.g., -OH or -NHx , where 2 ≥ x ≥ 1) to create pH contrast. The agent's incorporation of non-exchangeable protons (e.g., -CHy , where 3 ≥ y ≥ 1) makes it possible to map tissue temperature and/or pH using an MRSI method called biosensor imaging of redundant deviation in shifts (BIRDS). Hybrid probes based upon 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate chelate (DOTA4- ) and its methylated analog (1,4,7,10-tetraazacyclododecane-α, α', αâ³, αâ´-tetramethyl-1,4,7,10-tetraacetate, DOTMA4- ) were synthesized, and modified to create new tetra-amide chelates. Addition of several methyl groups per pendent arm of the symmetrical chelates, positioned proximally and distally to thulium ions (Tm3+ ), gave rise to favorable BIRDS properties (i.e., high signal-to-noise ratio (SNR) from non-exchangeable methyl proton peaks) and CEST responsiveness (i.e., from amide exchangeable protons). Structures of the Tm3+ probes elucidate the influence of methyl group placement on sensor performance. An eight-coordinate geometry with high symmetry was observed for the complexes: Tm-L1 was based on DOTA4- , whereas Tm-L2 and Tm-L3 were based on DOTMA4- , where the latter contained an additional carboxylate at the distal end of each arm. The distance of Tm3+ from terminal methyl carbons is a key determinant for sustaining BIRDS temperature sensitivity without compromising CEST pH contrast; however, water solubility was influenced by introduction of hydrophobic methyl groups and hydrophilic carboxylate. Combined BIRDS and CEST detection of Tm-L2, which features two high-SNR methyl peaks and a strong amide CEST peak, should enable simultaneous temperature and pH measurements for high-resolution molecular imaging in vivo.
Asunto(s)
Técnicas Biosensibles , Protones , Amidas , Técnicas Biosensibles/métodos , Quelantes , Medios de Contraste/química , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia MagnéticaRESUMEN
Under normal conditions, high sodium (Na+) in extracellular (Na+e) and blood (Na+b) compartments and low Na+ in intracellular milieu (Na+i) produce strong transmembrane (ΔNa+mem) and weak transendothelial (ΔNa+end) gradients respectively, and these manifest the cell membrane potential (Vm) as well as blood-brain barrier (BBB) integrity. We developed a sodium (23Na) magnetic resonance spectroscopic imaging (MRSI) method using an intravenously-administered paramagnetic polyanionic agent to measure ΔNa+mem and ΔNa+end. In vitro 23Na-MRSI established that the 23Na signal is intensely shifted by the agent compared to other biological factors (e.g., pH and temperature). In vivo 23Na-MRSI showed Na+i remained unshifted and Na+b was more shifted than Na+e, and these together revealed weakened ΔNa+mem and enhanced ΔNa+end in rat gliomas (vs. normal tissue). Compared to normal tissue, RG2 and U87 tumors maintained weakened ΔNa+mem (i.e., depolarized Vm) implying an aggressive state for proliferation, whereas RG2 tumors displayed elevated ∆Na+end suggesting altered BBB integrity. We anticipate that 23Na-MRSI will allow biomedical explorations of perturbed Na+ homeostasis in vivo.