Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Heart Rhythm ; 2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38823670

RESUMEN

BACKGROUND: It is unclear whether advances in management of acute coronary syndrome (ACS) and introduction of novel oral anticoagulants have changed outcomes in patients with ACS with concomitant atrial fibrillation (AF). OBJECTIVE: This study aimed to examine the incidence of AF in patients admitted for ACS and to evaluate its association with adverse outcomes, given the recent advances in management of both diseases. METHODS: Natural language processing search algorithms identified AF in patients admitted with ACS across 13 Northwell Health Hospitals from 2015 to 2021. Hierarchical generalized linear mixed modeling was used to assess the association between AF and in-hospital mortality, bleeding, and stroke outcomes; marginal Cox regression modeling was used to assess the association between AF and postdischarge mortality. RESULTS: Of 12,315 patients admitted for ACS, 3018 (24.5%) had AF with 1609 (53.3%) newly diagnosed. AF patients more commonly received anticoagulation with an oral anticoagulant (80.4% vs 12.3%) or heparin (61.9% vs 56.9%), had lengthier intensive care unit stay (72 vs 49 hours), and underwent fewer percutaneous coronary interventions (31.9% vs 53.1%). In-hospital bleeding, stroke, and mortality were higher in the AF group (15.3% vs 5.0%, 7.4% vs 2.4%, and 6.9% vs 2.1%, respectively). AF was an independent risk factor for all in-hospital outcomes (odds ratios of 2.5, 2.7, and 2.0 for bleeding, stroke, and mortality, respectively) as well as for postdischarge mortality (hazard ratio, 1.3; 95% CI, 1.2-1.5). CONCLUSION: AF is present in 25% of ACS patients and increases risk of in-hospital and postdischarge adverse outcomes. Additional data are required to direct optimal management.

2.
Cardiovasc Revasc Med ; 64: 15-20, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38388248

RESUMEN

BACKGROUND: Conduction disturbances are a common complication of transcatheter aortic valve replacement (TAVR). Mobile Cardiac Telemetry (MCT) allows for continuous monitoring with near "real time" alerts and has allowed for timely detection of conduction abnormalities and pacemaker placement in small trials. A standardized, systematic approach utilizing MCT devices post TAVR has not been widely implemented, leading to variation in use across hospital systems. OBJECTIVES: Our aim was to evaluate the utility of a standardized, systematic approach utilizing routine MCT to facilitate safe and earlier discharge by identifying conduction disturbances requiring permanent pacemaker (PPM) placement. We also sought to assess the occurrence of actionable arrhythmias in post-TAVR patients. METHODS: Using guidance from the JACC Scientific Expert Panel, a protocol was implemented starting in December 2019 to guide PPM placement post-TAVR across our health system. All patients who underwent TAVR from December 2019 to June 2021 across four hospitals within Northwell Health, who did not receive or have a pre-existing PPM received an MCT device at discharge and were monitored for 30 days. Clinical and follow-up data were collected and compared to pre initiative patients. RESULTS: During the initiative 693 patients were monitored with MCT upon discharge, 21 of whom required PPM placement. Eight of these patients had no conduction abnormality on initial or discharge ECG. 59 (8.6 %) patients were found to have new atrial fibrillation or flutter via MCT monitoring. There were no adverse events in the initiative group. Prior to the initiative, 1281 patients underwent TAVR over a one-year period. The initiative group had significantly shorter length of stay than pre-initiative patients (2.5 ± 4.5 vs 3.0 ± 3.8 days, p < 0.001) and lower overall PPM placement rate within 30 days post-TAVR (16 % vs 20.5 %, P = 0.0125). CONCLUSIONS: In our study, implementation of a standardized, systematic approach utilizing MCT in post-TAVR patients was safe and allowed for timely detection of conduction abnormalities requiring pacemaker placement. This strategy also detected new atrial fibrillation and flutter. Reduction in post TAVR pacemaker rate and length of stay were also noted although this effect is multifactorial.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Arritmias Cardíacas , Estimulación Cardíaca Artificial , Marcapaso Artificial , Valor Predictivo de las Pruebas , Telemetría , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Masculino , Femenino , Anciano de 80 o más Años , Anciano , Factores de Tiempo , Resultado del Tratamiento , Telemetría/instrumentación , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Factores de Riesgo , Atención Ambulatoria , Frecuencia Cardíaca , Estudios Retrospectivos , Alta del Paciente , Potenciales de Acción
3.
J Card Surg ; 37(12): 4937-4943, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36378870

RESUMEN

OBJECTIVE: The aim of this study was to compare outcomes of transcatheter heart valve (THV) choice in patients with left ventricular (LV) systolic dysfunction. BACKGROUND: The management congestive heart failure with combined LV systolic dysfunction and severe aortic stenosis (AS) is challenging, yet transcatheter aortic valve replacement (TAVR) has emerged as a suitable treatment option in such patients. Head-to-head comparisons among the balloon-expandable (BEV) and self-expandable (SEV) THV remain limited in this subgroup of patients. METHODS: In this retrospective study, we included patients with severe AS with LV systolic dysfunction (LVEF ≤40%) who underwent TAVR at four high volume centers. Two thousand and twenty-eight consecutive patients were analyzed, of which 335 patients met inclusion criteria. One hundred fourty-six patients (43%) received a SEV, and 189 patients (57%) received a BEV. RESULTS: Baseline characteristics were similar except for a higher proportion of females in the SEV group. The primary composite endpoint of in-hospital mortality, moderate or greater paravalvular (PVL), stroke, conversion to open surgery, aortic valve reintervention, and/or need for permanent pacemaker (PPM) was no different among THV choice. There was more PVL in the SEV group, but higher transaortic gradients in the BEV group. Clinical outcomes and quality of life measures were similar up to 1 year follow-up. CONCLUSION: The choice of THV in patients with severe AS and systolic dysfunction must be weighed on a case-by-case basis.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Disfunción Ventricular Izquierda , Femenino , Humanos , Estudios Retrospectivos , Volumen Sistólico , Calidad de Vida , Factores de Riesgo , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Disfunción Ventricular Izquierda/etiología , Resultado del Tratamiento , Diseño de Prótesis
4.
Ann Thorac Surg ; 114(6): 2149-2156, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35452664

RESUMEN

BACKGROUND: Transfusion in acute aortic syndromes has been studied in a limited fashion. We sought to describe contemporary transfusion practice for root replacement in acute (Stanford) type A aortic dissection. METHODS: The Society of Thoracic Surgeons Adult Cardiac Surgery Database was interrogated to identify patients who underwent primary aortic root replacement for acute (Stanford) type A aortic dissection (July 2014 to June 2017). Patients (n = 1558) were stratified by type of root replacement. Multivariate regression was used to determine those variables associated with transfusion and postoperative morbidity. RESULTS: Transfusion was required in 90.5% of cases (n = 1410). Operative mortality for all patients was 17.3% (261 deaths). Intraoperative red blood cell transfusion portended reduced short-term survival (odds ratio [OR] 2.00, P = .025). Massive postoperative transfusion was associated with prolonged ventilation (OR 13.47, P < .001), sepsis (OR 4.13, P < .001), and new dialysis-dependent renal failure (OR 2.43, P < .001). Women were more likely to require transfusion (OR 3.03, P < .001), as were patients who had coronary artery bypass (OR 1.57, P = .009), and those in shock (OR 2.27, P < .001). Valve-sparing aortic root replacement was associated with reduced transfusion requirements vs composite roots. Institutional case volume was not appreciably correlated with transfusion. CONCLUSIONS: Most patients undergoing root replacement for aortic dissection require blood products. Composite root replacement is associated with a greater likelihood of transfusion than a valve-sparing operation. Transfusion independently foreshadows greater operative mortality.


Asunto(s)
Disección Aórtica , Adulto , Humanos , Femenino , Estudios Retrospectivos , Resultado del Tratamiento , Disección Aórtica/cirugía , Aorta/cirugía , Puente de Arteria Coronaria , Complicaciones Posoperatorias/epidemiología , Válvula Aórtica/cirugía
6.
J Cardiothorac Surg ; 15(1): 205, 2020 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-32736644

RESUMEN

BACKGROUND: Direct cannulation of the innominate artery for selective antegrade cerebral perfusion has been shown to be safe in elective proximal aortic reconstructions. We sought to evaluate the safety of this technique in acute aortic dissection. METHODS: A multi-institutional retrospective review was undertaken of patients who underwent proximal aortic reconstruction for Stanford type A dissection between 2006 and 2016. Those patients who had direct innominate artery cannulation for selective antegrade cerebral perfusion were selected for analysis. RESULTS: Seventy-five patients underwent innominate artery cannulation for ACP for Stanford Type A Dissections. Isolated replacement of the ascending aorta was performed in 36 patients (48.0%), concomitant aortic root replacement was required in 35 patients (46.7%), of whom 7 had a valve-sparing aortic root replacement, ascending aorta and arch replacement was required in 4 patients (5%). Other procedures included frozen elephant trunk (n = 11 (14.7%)), coronary artery bypass grafting (n = 20 (26.7%)), and peripheral arterial bypass (n = 4 (5.3%)). Mean hypothermic circulatory arrest time was 19 ± 13 min. Thirty-day mortality was 14.7% (n = 11). Perioperative stroke occurred in 7 patients (9.3%). CONCLUSIONS: This study is the first comprehensive review of direct innominate artery cannulation through median sternotomy for selective antegrade cerebral perfusion in aortic dissection. Our experience suggests that this strategy is a safe and effective technique compared to other reported methods of cannulation and cerebral protection for delivering selective antegrade cerebral perfusion in these cases.


Asunto(s)
Aorta , Disección Aórtica/mortalidad , Tronco Braquiocefálico , Cateterismo , Disección Aórtica/cirugía , Circulación Cerebrovascular , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Análisis de Supervivencia , Virginia
7.
Ann Thorac Surg ; 110(4): 1225-1233, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32119850

RESUMEN

BACKGROUND: Data on blood use in proximal aortic surgery is limited. This study sought to establish quality benchmarks in the pattern of transfusion during elective aortic root replacement. METHODS: The Society of Thoracic Surgeons Adult Cardiac Surgery Database was queried to identify all patients who underwent primary elective aortic root replacement between July 2014 and June 2017. Multivariable negative binomial regressions were used to determine whether perioperative transfusion was associated with demographic or procedural factors. Multivariable logistic regression analysis was performed for clinical outcomes. RESULTS: Of 5559 patients analyzed, 38.95% (n = 2165) received no blood products. Patients who had a valve-sparing root replacement were less likely to undergo transfusion than those who received composite roots (bioprosthetic or mechanical valves) or homografts. The 30-day mortality for all patients was 2.57% (n = 143). Transfusion was associated with an increased risk of death at 30 days (odds ratio [OR], 1.833; P = .012), more frequent reoperation for bleeding (OR, 1.766; P < .001), prolonged ventilation (OR, 1.935; P < .001), a longer postoperative hospital stay (OR, 1.056; P < .001), and a higher incidence of new dialysis-dependent renal failure (OR, 2.088; P = .003). There was no correlation between institutional case volume and transfusion practice. CONCLUSIONS: Elective aortic root replacement can be performed with acceptable requirements for blood products. Composite root replacement has a greater likelihood of transfusion than does a valve-sparing procedure. Transfusion is independently associated with more complications after elective aortic root surgery, including 30-day mortality.


Asunto(s)
Enfermedades de la Aorta/cirugía , Transfusión Sanguínea , Implantación de Prótesis Vascular , Implantación de Prótesis de Válvulas Cardíacas , Adulto , Anciano , Bases de Datos Factuales , Procedimientos Quirúrgicos Electivos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
8.
J Thorac Cardiovasc Surg ; 157(2): 791-800, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30669239

RESUMEN

OBJECTIVE: Tracheobronchomalacia is a progressive, debilitating disease with limited treatment options. Open tracheobronchoplasty (TBP) is an accepted surgical option for management of severe tracheobronchomalacia. This study examined the outcomes of the first reported series of robot-assisted TBP (R-TBP). METHODS: We retrospectively reviewed the records of patients with clinical suspicion for tracheobronchomalacia who had dynamic computed tomography scan and subsequent R-TBP from May 2016 to December 2017. RESULTS: Four hundred thirty-five patients underwent dynamic computed tomography scan for suspicion of tracheobronchomalacia. Of this group, 42 patients underwent R-TBP. In the surgery group, the median age was 66 years (interquartile range, 39-72 years) and there were 30 women (71%). Respiratory comorbidities included asthma (88%) and chronic obstructive pulmonary disease (52%). The median operative time was 249 minutes (interquartile range, 266-277 minutes). Median hospital length of stay was 3 days (interquartile range, 2-4.75 days), and there were 19 postoperative complications (11 minor and 8 major). There were no mortalities at 90 days. Comparison of preoperative and postoperative pulmonary function testing demonstrated improvement in forced expiratory volume at 1 second by 13.5% (P = .01), forced vital capacity by 14.5% (P < .0001), and peak expiratory flow rate by 21.0% (P < .0001). Quality of life questionnaires also showed improvement with 82% reporting overall satisfaction with the procedure. CONCLUSIONS: R-TBP can be performed with low morbidity and mortality. Early follow-up reveals significant improvement in pulmonary function testing and high patient satisfaction when compared with preoperative baseline. Long-term follow-up is needed to demonstrate the durability of R-TBP and substantiate its role in the management of patients with symptomatic, severe tracheobronchomalacia.


Asunto(s)
Procedimientos Quirúrgicos Robotizados/instrumentación , Mallas Quirúrgicas , Cirugía Torácica Asistida por Video/instrumentación , Procedimientos Quirúrgicos Torácicos/instrumentación , Traqueobroncomalacia/cirugía , Adulto , Anciano , Femenino , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias/etiología , Calidad de Vida , Recuperación de la Función , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Índice de Severidad de la Enfermedad , Cirugía Torácica Asistida por Video/efectos adversos , Procedimientos Quirúrgicos Torácicos/efectos adversos , Factores de Tiempo , Tomografía Computarizada por Rayos X , Traqueobroncomalacia/diagnóstico por imagen , Traqueobroncomalacia/fisiopatología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...