Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
MAGMA ; 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38703246

RESUMEN

OBJECTIVE: Diffusion-weighted MRI is a technique that can infer microstructural and microcirculatory features from biological tissue, with particular application to renal tissue. There is extensive literature on diffusion tensor imaging (DTI) of anisotropy in the renal medulla, intravoxel incoherent motion (IVIM) measurements separating microstructural from microcirculation effects, and combinations of the two. However, interpretation of these features and adaptation of more specific models remains an ongoing challenge. One input to this process is a whole organ distillation of corticomedullary contrast of diffusion metrics, as has been explored for other renal biomarkers. MATERIALS AND METHODS: In this work, we probe the spatial dependence of diffusion MRI metrics with concentrically layered segmentation in 11 healthy kidneys at 3 T. The metrics include those from DTI, IVIM, a combined approach titled "REnal Flow and Microstructure AnisotroPy (REFMAP)", and a multiply encoded model titled "FC-IVIM" providing estimates of fluid velocity and branching length. RESULTS: Fractional anisotropy decreased from the inner kidney to the outer kidney with the strongest layer correlation in both parenchyma (including cortex and medulla) and medulla with Spearman correlation coefficients and p-values (r, p) of (0.42, <0.001) and (0.37, <0.001), respectively. Also, dynamic parameters derived from the three models significantly decreased with a high correlation from the inner to the outer parenchyma or medulla with (r, p) ranges of (0.46-0.55, <0.001). CONCLUSIONS: These spatial trends might find implications for indirect assessments of kidney physiology and microstructure using diffusion MRI.

2.
J Magn Reson Imaging ; 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38485244

RESUMEN

BACKGROUND: Postacute Covid-19 patients commonly present with respiratory symptoms; however, a noninvasive imaging method for quantitative characterization of respiratory patterns is lacking. PURPOSE: To evaluate if quantitative characterization of respiratory pattern on free-breathing higher temporal resolution MRI stratifies patients by cardiopulmonary symptom burden. STUDY TYPE: Prospective analysis of retrospectively acquired data. SUBJECTS: A total of 37 postacute Covid-19 patients (25 male; median [interquartile range (IQR)] age: 58 [42-64] years; median [IQR] days from acute infection: 335 [186-449]). FIELD STRENGTH/SEQUENCE: 0.55 T/two-dimensional coronal true fast imaging with steady-state free precession (trueFISP) at higher temporal resolution. ASSESSMENT: Patients were stratified into three groups based on presence of no (N = 11), 1 (N = 14), or ≥2 (N = 14) cardiopulmonary symptoms, assessed using a standardized symptom inventory within 1 month of MRI. An automated lung postprocessing workflow segmented each lung in each trueFISP image (temporal resolution 0.2 seconds) and respiratory curves were generated. Quantitative parameters were derived including tidal lung area, rates of inspiration and expiration, lung area coefficient of variability (CV), and respiratory incoherence (departure from sinusoidal pattern) were. Pulmonary function tests were recorded if within 1 month of MRI. Qualitative assessment of respiratory pattern and lung opacity was performed by three independent readers with 6, 9, and 23 years of experience. STATISTICAL TESTS: Analysis of variance to assess differences in demographic, clinical, and quantitative MRI parameters among groups; univariable analysis and multinomial logistic regression modeling to determine features predictive of patient symptom status; Akaike information criterion to compare the quality of regression models; Cohen and Fleiss kappa (κ) to quantify inter-reader reliability. Two-sided 5% significance level was used. RESULTS: Tidal area and lung area CV were significantly higher in patients with two or more symptoms than in those with one or no symptoms (area: 15.4 cm2 vs. 12.9 cm2 vs. 12.8 cm2 ; CV: 0.072, 0.067, and 0.058). Respiratory incoherence was significantly higher in patients with two or more symptoms than in those with one or no symptoms (0.05 vs. 0.043 vs. 0.033). There were no significant differences in patient age (P = 0.19), sex (P = 0.88), lung opacity severity (P = 0.48), or pulmonary function tests (P = 0.35-0.97) among groups. Qualitative reader assessment did not distinguish between groups and showed slight inter-reader agreement (κ = 0.05-0.11). DATA CONCLUSION: Quantitative respiratory pattern measures derived from dynamic higher-temporal resolution MRI have potential to stratify patients by symptom burden in a postacute Covid-19 cohort. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 3.

3.
Magn Reson Med ; 91(5): 1803-1821, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38115695

RESUMEN

PURPOSE: K trans $$ {K}^{\mathrm{trans}} $$ has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for K trans $$ {K}^{\mathrm{trans}} $$ quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging-Dynamic Contrast-Enhanced (OSIPI-DCE) challenge was designed to benchmark methods to better help the efforts to standardize K trans $$ {K}^{\mathrm{trans}} $$ measurement. METHODS: A framework was created to evaluate K trans $$ {K}^{\mathrm{trans}} $$ values produced by DCE-MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for K trans $$ {K}^{\mathrm{trans}} $$ quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' K trans $$ {K}^{\mathrm{trans}} $$ values, the applied software, and a standard operating procedure. These were evaluated using the proposed OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score defined with accuracy, repeatability, and reproducibility components. RESULTS: Across the 10 received submissions, the OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0-1 = lowest-highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in K trans $$ {K}^{\mathrm{trans}} $$ analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility. CONCLUSIONS: This study reports results from the OSIPI-DCE challenge and highlights the high inter-software variability within K trans $$ {K}^{\mathrm{trans}} $$ estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real-world clinical setting, many of these tools may perform differently with different benchmarking methodology.


Asunto(s)
Medios de Contraste , Imagen por Resonancia Magnética , Humanos , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Programas Informáticos , Algoritmos
4.
J Magn Reson Imaging ; 2023 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-37702382

RESUMEN

BACKGROUND: Monoexponential apparent diffusion coefficient (ADC) and biexponential intravoxel incoherent motion (IVIM) analysis of diffusion-weighted imaging is helpful in the characterization of breast tumors. However, repeatability/reproducibility studies across scanners and across sites are scarce. PURPOSE: To evaluate the repeatability and reproducibility of ADC and IVIM parameters (tissue diffusivity (Dt ), perfusion fraction (Fp ) and pseudo-diffusion (Dp )) within and across sites employing MRI scanners from different vendors utilizing 16-channel breast array coils in a breast diffusion phantom. STUDY TYPE: Phantom repeatability. PHANTOM: A breast phantom containing tubes of different polyvinylpyrrolidone (PVP) concentrations, water, fat, and sponge flow chambers, together with an MR-compatible liquid crystal (LC) thermometer. FIELD STRENGTH/SEQUENCE: Bipolar gradient twice-refocused spin echo sequence and monopolar gradient single spin echo sequence at 3 T. ASSESSMENT: Studies were performed twice in each of two scanners, located at different sites, on each of 2 days, resulting in four studies per scanner. ADCs of the PVP and water were normalized to the vendor-provided calibrated values at the temperature indicated by the LC thermometer for repeatability/reproducibility comparisons. STATISTICAL TESTS: ADC and IVIM repeatability and reproducibility within and across sites were estimated via the within-system coefficient of variation (wCV). Pearson correlation coefficient (r) was also computed between IVIM metrics and flow speed. A P value <0.05 was considered statistically significant. RESULTS: ADC and Dt demonstrated excellent repeatability (<2%; <3%, respectively) and reproducibility (both <5%) at the two sites. Fp and Dp exhibited good repeatability (mean of two sites 3.67% and 5.59%, respectively) and moderate reproducibility (mean of two sites 15.96% and 13.3%, respectively). The mean intersite reproducibility (%) of Fp /Dp /Dt was 50.96/13.68/5.59, respectively. Fp and Dt demonstrated high correlations with flow speed while Dp showed lower correlations. Fp correlations with flow speed were significant at both sites. DATA CONCLUSION: IVIM reproducibility results were promising and similar to ADC, particularly for Dt . The results were reproducible within both sites, and a progressive trend toward reproducibility across sites except for Fp . LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 1.

5.
Magn Reson Imaging ; 100: 93-101, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36924807

RESUMEN

PURPOSE: Diffusion-weighted imaging (DWI) of the abdomen has increased dramatically for both research and clinical purposes. Motion and static field inhomogeneity related challenges limit image quality of abdominopelvic imaging with the most conventional echo-planar imaging (EPI) pulse sequence. While reversed phase encoded imaging is increasingly used to facilitate distortion correction, it typically assumes one motion independent magnetic field distribution. In this study, we describe a more generalized workflow for the case of kidney DWI in which the field inhomogeneity at multiple respiratory phases is mapped and used to correct all images in a multi-contrast DWI series. METHODS: In this HIPAA-compliant and IRB-approved prospective study, 8 volunteers (6 M, ages 28-51) had abdominal imaging performed in a 3 T MRI system (MAGNETOM Prisma; Siemens Healthcare, Erlangen, Germany) with ECG gating. Coronal oblique T2-weighted HASTE images were collected for anatomical reference. Sagittal phase-contrast (PC) MRI images through the left renal artery were collected to determine systolic and diastolic phases. Cardiac triggered oblique coronal DWI were collected at 10 b-values between 0 and 800 s/mm2 and 12 directions. DWI series were distortion corrected using field maps generated by forward and reversed phase encoded b = 0 images collected over the full respiratory cycle and matched by respiratory phase. Morphologic accuracy, intraseries spatial variability, and diffusion tensor imaging (DTI) metrics mean diffusivity (MD) and fractional anisotropy (FA) were compared for results generated with no distortion correction, correction with only one respiratory bin, and correction with multiple respiratory bins across the breathing cycle. RESULTS: Computed field maps showed significant variation in static field with kidney laterality, region, and respiratory phase. Distortion corrected images showed significantly better registration to morphologic images than uncorrected images; for the left kidney, the multiple bin correction outperformed one bin correction. Line profile analysis showed significantly reduced spatial variation with multiple bins than one bin correction. DTI metrics were mostly similar between correction methods, with some differences observed in MD between uncorrected and corrected datasets. CONCLUSIONS: Our results indicate improved morphology of kidney DWI and derived parametric maps as well as reduced variability over the full image series using the motion-resolved distortion correction. This work highlights some morphologic and quantitative metric improvements can be obtained for kidney DWI when distortion correction is performed in a respiratory-resolved manner.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen de Difusión Tensora , Humanos , Adulto , Persona de Mediana Edad , Estudios Prospectivos , Imagen de Difusión por Resonancia Magnética/métodos , Imagen por Resonancia Magnética , Riñón/diagnóstico por imagen , Imagen Eco-Planar/métodos , Movimiento (Física)
6.
J Magn Reson Imaging ; 58(1): 210-220, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36399101

RESUMEN

BACKGROUND: Renal diffusion-weighted imaging (DWI) involves microstructure and microcirculation, quantified with diffusion tensor imaging (DTI), intravoxel incoherent motion (IVIM), and hybrid models. A better understanding of their contrast may increase specificity. PURPOSE: To measure modulation of DWI with cardiac phase and flow-compensated (FC) diffusion gradient waveforms. STUDY TYPE: Prospective. POPULATION: Six healthy volunteers (ages: 22-48 years, five females), water phantom. FIELD STRENGTH/SEQUENCE: 3-T, prototype DWI sequence with 2D echo-planar imaging, and bipolar (BP) or FC gradients. 2D Half-Fourier Single-shot Turbo-spin-Echo (HASTE). Multiple-phase 2D spoiled gradient-echo phase contrast (PC) MRI. ASSESSMENT: BP and FC water signal decays were qualitatively compared. Renal arteries and velocities were visualized on PC-MRI. Systolic (peak velocity), diastolic (end stable velocity), and pre-systolic (before peak velocity) phases were identified. Following mutual information-based retrospective self-registration of DWI within each kidney, and Marchenko-Pastur Principal Component Analysis (MPPCA) denoising, combined IVIM-DTI analysis estimated mean diffusivity (MD), fractional anisotropy (FA), and eigenvalues (λi) from tissue diffusivity (Dt ), perfusion fraction (fp ), and pseudodiffusivity (Dp , Dp,axial , Dp,radial ), for each tissue (cortex/medulla, segmented on b0/FA respectively), phase, and waveform (BP, FC). Monte Carlo water diffusion simulations aided data interpretation. STATISTICAL TESTS: Mixed model regression probed differences between tissue types and pulse sequences. Univariate general linear model analysis probed variations among cardiac phases. Spearman correlations were measured between diffusion metrics and renal artery velocities. Statistical significance level was set at P < 0.05. RESULTS: Water BP and FC signal decays showed no differences. Significant pulse sequence dependence occurred for λ1 , λ3 , FA, Dp , fp , Dp,axial , Dp,radial in cortex and medulla, and medullary λ2 . Significant cortex/medulla differences occurred with BP for all metrics except MD (systole [P = 0.224]; diastole [P = 0.556]). Significant phase dependence occurred for Dp , Dp,axial , Dp,radial for BP and medullary λ1 , λ2 , λ3 , MD for FC. FA correlated significantly with velocity. Monte Carlo simulations indicated medullary measurements were consistent with a 34 µm tubule diameter. DATA CONCLUSION: Cardiac gating and flow compensation modulate of measurements of renal diffusion. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Imagen de Difusión Tensora , Riñón , Femenino , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Imagen de Difusión Tensora/métodos , Anisotropía , Estudios Prospectivos , Estudios Retrospectivos , Riñón/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Movimiento (Física) , Agua
7.
J Clin Med ; 11(7)2022 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-35407587

RESUMEN

Given the central role of interstitial fibrosis in disease progression in chronic kidney disease (CKD), a role for diffusion-weighted MRI has been pursued. We evaluated the feasibility and preliminary efficacy of using radiomic features to phenotype apparent diffusion coefficient (ADC) maps and hence to the clinical classification(s) of the participants. The study involved 40 individuals (10 healthy and 30 with CKD (eGFR < 60 mL/min/1.73 m2)). Machine learning methods, such as hierarchical clustering and logistic regression, were used. Clustering resulted in the identification of two clusters, one including all individuals with CKD (n = 17), while the second one included all the healthy volunteers (n = 10) and the remaining individuals with CKD (n = 13), resulting in 100% specificity. Logistic regression identified five radiomic features to classify participants as with CKD vs. healthy volunteers, with a sensitivity and specificity of 93% and 70%, respectively, and an AUC of 0.95. Similarly, four radiomic features were able to classify participants as rapid vs. non-rapid CKD progressors among the 30 individuals with CKD, with a sensitivity and specificity of 71% and 43%, respectively, and an AUC of 0.75. These promising preliminary data should support future studies with larger numbers of participants with varied disease severity and etiologies to improve performance.

8.
Eur J Radiol ; 145: 110031, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34801878

RESUMEN

PURPOSE: To assess prognostic value of body composition parameters measured at CT to predict risk of hospitalization in patients with COVID-19 infection. METHODS: 177 patients with SARS-CoV-2 infection and with abdominopelvic CT were included in this retrospective IRB approved two-institution study. Patients were stratified based on disease severity as outpatients (no hospital admission) and patients who were hospitalized (inpatients). Two readers blinded to the clinical outcome segmented axial CT images at the L3 vertebral body level for visceral adipose tissue (VAT), subcutaneous adipose tissue (SAT), muscle adipose tissue (MAT), muscle mass (MM). VAT to total adipose tissue ratio (VAT/TAT), MAT/MM ratio, and muscle index (MI) at L3 were computed. These measures, along with detailed clinical risk factors, were compared in patients stratified by severity. Various logistic regression clinical and clinical + imaging models were compared to discriminate inpatients from outpatients. RESULTS: There were 76 outpatients (43%) and 101 inpatients. Male gender (p = 0.013), age (p = 0.0003), hypertension (p = 0.0003), diabetes (p = 0.0001), history of cardiac disease (p = 0.007), VAT/TAT (p < 0.0001), and MAT/MM (p < 0.0001), but not BMI, were associated with hospitalization. A clinical model (age, gender, BMI) had AUC of 0.70. Addition of VAT/TAT to the clinical model improved the AUC to 0.73. Optimal model that included gender, BMI, race (Black), MI, VAT/TAT, as well as interaction between gender and VAT/TAT and gender and MAT/MM demonstrated the highest AUC of 0.83. CONCLUSION: MAT/MM and VAT/TAT provides important prognostic information in predicting patients with COVID-19 who are likely to require hospitalization.


Asunto(s)
COVID-19 , Composición Corporal , Índice de Masa Corporal , Hospitalización , Humanos , Grasa Intraabdominal , Masculino , Estudios Retrospectivos , SARS-CoV-2 , Tomografía Computarizada por Rayos X
9.
Abdom Radiol (NY) ; 46(2): 818-825, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32748252

RESUMEN

PURPOSE: To assess visceral (VAT), subcutaneous (SAT), and total adipose tissue (TAT) estimates at abdominopelvic CT in COVID-19 patients with different severity, and analyze Body Mass Index (BMI) and CT estimates of fat content in patients requiring hospitalization. METHODS: In this retrospective IRB approved HIPPA compliant study, 51 patients with SARS-CoV-2 infection with abdominopelvic CT were included. Patients were stratified based on disease severity as outpatient (no hospital admission) and patients who were hospitalized. Subset of hospitalized patient required mechanical ventilation (MV). A radiologist blinded to the clinical outcome evaluated single axial slice on CT at L3 vertebral body for VATL3, SATL3, TATL3, and VAT/TATL3. These measures along with age, gender, and BMI were compared. A clinical model that included age, sex, and BMI was compared to clinical + CT model that also included VATL3 to discriminate hospitalized patients from outpatients. RESULTS: There were ten outpatients and 41 hospitalized patients. 11 hospitalized patients required MV. There were no significant differences in age and BMI between the hospitalized and outpatients (all p > 0.05). There was significantly higher VATL3 and VAT/TATL3 in hospitalized patients compared to the outpatients (all p < 0.05). Area under the curve (AUC) of the clinical + CT model was higher compared to the clinical model (AUC 0.847 versus 0.750) for identifying patients requiring hospitalization. CONCLUSION: Higher VATL3 was observed in COVID-19 patients that required hospitalization compared to the outpatients, and addition of VATL3 to the clinical model improved AUC in discriminating hospitalized from outpatients in this preliminary study.


Asunto(s)
COVID-19/fisiopatología , Grasa Intraabdominal/diagnóstico por imagen , Grasa Intraabdominal/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Medición de Riesgo/métodos , SARS-CoV-2 , Índice de Severidad de la Enfermedad , Adulto Joven
10.
Acad Radiol ; 28(12): 1699-1708, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-33127308

RESUMEN

RATIONALE AND OBJECTIVES: Periventricular and deep white matter hyperintensities (WMHs) in the elderly have been reported with distinctive roles in the progression of cognitive decline and dementia. However, the definition of these two subregions of WMHs is arbitrary and varies across studies. Here, we evaluate three partition methods for WMH subregions, including two widely used conventional methods (CV & D10) and one novel method based on bilateral distance (BD). MATERIALS AND METHODS: The three partition methods were assessed on the MRI scans of 60 subjects, with 20 normal control, 20 mild cognitive impairment, and 20 Alzheimer's disease (AD). Resulting WMH subregional volumes were (1) compared among different partition methods and subject groups, and (2) tested for clinical associations with cognition and dementia. Inter-rater, intrarater, and interscan reproducibility of WMHs volumes were tested on 12 randomly selected subjects from the 60. RESULTS: For all three partition methods, increased periventricular WMHs were found for AD subjects over normal control. For BD and D10, but not CV method, increased Periventricular WMHs were found for AD subjects over mild cognitive impairment. Significant correlations were found between PVWMHs and Mini-Mental State Examination, Montreal Cognitive Assessment, and Clinical Dementia Rating scores. Furthermore, PVWMHs under BD partition showed higher correlations than D10 and CV. High intrarater and interscan reproducibility (ICCA = 0.998 and 0.992 correspondingly) and substantial inter-rater reproducibility (ICCA = 0.886) were detected. CONCLUSION: Different WMH partition methods showed comparable diagnostic abilities. The proposed BD method showed advantages in quantifying PVWMH over conventional CV and D10 methods, in terms of higher consistency, larger contrast, and higher diagnosis accuracy. Furthermore, the PVWMH under BD partition showed stronger clinical correlations than conventional methods.


Asunto(s)
Disfunción Cognitiva , Sustancia Blanca , Anciano , Envejecimiento , Encéfalo/diagnóstico por imagen , Disfunción Cognitiva/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Sustancia Blanca/diagnóstico por imagen
11.
Sci Rep ; 10(1): 20764, 2020 11 27.
Artículo en Inglés | MEDLINE | ID: mdl-33247166

RESUMEN

In this study, we investigate the feasibility of using dynamic contrast enhanced magnetic resonance imaging (DCE-MRI), diffusion weighted imaging (DWI), and dynamic positron emission tomography (PET) for detection of metastatic lymph nodes in head and neck squamous cell carcinoma (HNSCC) cases. Twenty HNSCC patients scheduled for lymph node dissection underwent DCE-MRI, dynamic PET, and DWI using a PET-MR scanner within one week prior to their planned surgery. During surgery, resected nodes were labeled to identify their nodal levels and sent for routine clinical pathology evaluation. Quantitative parameters of metastatic and normal nodes were calculated from DCE-MRI (ve, vp, PS, Fp, Ktrans), DWI (ADC) and PET (Ki, K1, k2, k3) to assess if an individual or a combination of parameters can classify normal and metastatic lymph nodes accurately. There were 38 normal and 11 metastatic nodes covered by all three imaging methods and confirmed by pathology. 34% of all normal nodes had volumes greater than or equal to the smallest metastatic node while 4 normal nodes had SUV > 4.5. Among the MRI parameters, the median vp, Fp, PS, and Ktrans values of the metastatic lymph nodes were significantly lower (p = <0.05) than those of normal nodes. ve and ADC did not show any statistical significance. For the dynamic PET parameters, the metastatic nodes had significantly higher k3 (p value = 8.8 × 10-8) and Ki (p value = 5.3 × 10-8) than normal nodes. K1 and k2 did not show any statistically significant difference. Ki had the best separation with accuracy = 0.96 (sensitivity = 1, specificity = 0.95) using a cutoff of Ki = 5.3 × 10-3 mL/cm3/min, while k3 and volume had accuracy of 0.94 (sensitivity = 0.82, specificity = 0.97) and 0.90 (sensitivity = 0.64, specificity = 0.97) respectively. 100% accuracy can be achieved using a multivariate logistic regression model of MRI parameters after thresholding the data with Ki < 5.3 × 10-3 mL/cm3/min. The results of this preliminary study suggest that quantitative MRI may provide additional value in distinguishing metastatic nodes, particularly among small nodes, when used together with FDG-PET.


Asunto(s)
Fluorodesoxiglucosa F18/metabolismo , Neoplasias de Cabeza y Cuello/patología , Ganglios Linfáticos/patología , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos , Carcinoma de Células Escamosas de Cabeza y Cuello/secundario , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/metabolismo , Neoplasias de Cabeza y Cuello/cirugía , Humanos , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/metabolismo , Ganglios Linfáticos/cirugía , Metástasis Linfática , Masculino , Persona de Mediana Edad , Pronóstico , Radiofármacos/metabolismo , Carcinoma de Células Escamosas de Cabeza y Cuello/diagnóstico por imagen , Carcinoma de Células Escamosas de Cabeza y Cuello/metabolismo , Carcinoma de Células Escamosas de Cabeza y Cuello/cirugía
12.
BJU Int ; 124(1): 76-86, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30378238

RESUMEN

OBJECTIVE: To undertake an early proof-of-concept study on a novel, semi-automated texture-based scoring system in order to enhance the association between magnetic resonance imaging (MRI) lesions and clinically significant prostate cancer (SPCa). PATIENTS AND METHODS: With ethics approval, 536 imaging volumes were generated from 20 consecutive patients who underwent multiparametric MRI (mpMRI) at time of biopsy. Volumes of interest (VOIs) included zonal anatomy segmentation and suspicious MRI lesions for cancer (Likert Scale score >2). Entropy (E), measuring heterogeneity, was computed from VOIs and plotted as a multiparametric score defined as the entropy score (ES) = E ADC + E Ktrans + E Ve + E T2WI. The reference test that was used to define the ground truth comprised systematic saturation biopsies coupled with MRI-targeted sampling. This generated 422 cores in all that were individually labelled and oriented in three-dimensions. Diagnostic accuracy for detection of SPCa, defined as Gleason score ≥3 + 4 or >3 mm of any grade of cancer on a single core, was assessed using receiver operating characteristics, correlation, and descriptive statistics. The proportion of cancerous lesions detected by ES and visual scoring (VS) were statistically compared using the paired McNemar test. RESULTS: Any cancer (Gleason score 6-8) was found in 12 of the 20 (60%) patients, with a median PSA level of 8.22 ng/mL. SPCa (mean [95% confidence interval, CI] ES = 17.96 [0.72] NATural information unit [NAT]) had a significantly higher ES than non-SPCa (mean [95% CI] ES = 15.33 [0.76] NAT). The ES correlated with Gleason score (rs = 0.568, P = 0.033) and maximum cancer core length (ρ = 0.781; P < 0.001). The area under the curve for the ES (0.89) and VS (0.91) were not significantly different (P = 0.75) for the detection of SPCa amongst MRI lesions. Best ES estimated numerical threshold of 16.61 NAT led to a sensitivity of 100% and negative predictive value of 100%. The proportion of MRI lesions that were found to be positive for SPCa using this ES threshold (54%) was significantly higher (P < 0.001) than using the VS (24% of score 3, 4, 5) in a paired analysis using the McNemar test. In all, 53% of MRI lesions would have avoided biopsy sampling without missing significant disease. CONCLUSION: Capturing heterogeneity of prostate cancer across multiple MRI sequences with the ES yielded high performances for the detection and stratification of SPCa. The ES outperformed the VS in predicting positivity of lesions, holding promise in the selection of targets for biopsy and calling for further understanding of this association.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Anciano , Estudios de Cohortes , Humanos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Valor Predictivo de las Pruebas , Prueba de Estudio Conceptual , Curva ROC
13.
J Magn Reson Imaging ; 48(1): 188-197, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29331053

RESUMEN

BACKGROUND: Diffusion-weighted imaging (DWI) provides insight into the pathophysiology underlying renal dysfunction. Variants of DWI include intravoxel incoherent motion (IVIM), which differentiates between microstructural diffusion and vascular or tubular flow, and diffusion tensor imaging (DTI), which quantifies diffusion directionality. PURPOSE: To investigate the reproducibility of joint IVIM-DTI and compare controls to presurgical renal mass patients. STUDY TYPE: Prospective cross-sectional. SUBJECTS: Thirteen healthy controls and ten presurgical renal mass patients were scanned. Ten controls were scanned twice to investigate reproducibility. FIELD STRENGTH/SEQUENCE: Subjects were scanned on a 3T system using 10 b-values and 20 diffusion directions for IVIM-DTI in a study approved by the local Institutional Review Board. ASSESSMENT: Retrospective coregistration and measurement of joint IVIM-DTI parameters were performed. STATISTICAL ANALYSIS: Parameter reproducibility was defined as intraclass correlation coefficient (ICC) >0.7 and coefficient of variation (CV) <30%. Patient data were stratified by lesion side (contralateral/ipsilateral) for comparison with controls. Corticomedullary differentiation was evaluated. RESULTS: In controls, the reproducible subset of REnal Flow and Microstructure AnisotroPy (REFMAP) parameters had average ICC = 0.82 and CV = 7.5%. In renal mass patients, medullary fractional anisotropy (FA) was significantly lower than in controls (0.227 ± 0.072 vs. 0.291 ± 0.044, P = 0.016 for the kidney contralateral to the mass and 0.228 ± 0.070 vs. 0.291 ± 0.044, P = 0.018 for the kidney ipsilateral). In the kidney ipsilateral to the mass, cortical Dp,radial was significantly higher than in controls (P = 0.012). Conversely, medullary Dp,axial was significantly lower in contralateral than ipsilateral kidneys (P = 0.027) and normal controls (P = 0.044). DATA CONCLUSION: REFMAP-MRI parameters provide unique information regarding renal dysfunction. In presurgical renal mass patients, directional flow changes were noted that were not identified with IVIM analysis alone. Both contralateral and ipsilateral kidneys in patients show reductions in structural diffusivities and anisotropy, while flow metrics showed opposing changes in contralateral vs. ipsilateral kidneys. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Neoplasias Renales/diagnóstico por imagen , Riñón/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Anisotropía , Índice de Masa Corporal , Estudios Transversales , Imagen de Difusión Tensora , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Movimiento (Física) , Distribución Normal , Periodo Preoperatorio , Estudios Prospectivos , Reproducibilidad de los Resultados , Estudios Retrospectivos
14.
J Magn Reson Imaging ; 47(6): 1685-1691, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29140576

RESUMEN

BACKGROUND: Potential clinical implications of the level of background parenchymal enhancement (BPE) on breast MRI are increasing. Currently, BPE is typically evaluated subjectively. Tests of concordance between subjective BPE assessment and computer-assisted quantified BPE have not been reported. PURPOSE OR HYPOTHESIS: To compare subjective radiologist assessment of BPE with objective quantified parenchymal enhancement (QPE). STUDY TYPE: Cross-sectional observational study. POPULATION: Between 7/24/2015 and 11/27/2015, 104 sequential patients (ages 23 - 81 years, mean 49 years) without breast cancer underwent breast MRI and were included in this study. FIELD STRENGTH/SEQUENCE: 3T; fat suppressed axial T2, axial T1, and axial fat suppressed T1 before and after intravenous contrast. ASSESSMENT: Four breast imagers graded BPE at 90 and 180 s after contrast injection on a 4-point scale (a-d). Fibroglandular tissue masks were generated using a phantom-validated segmentation algorithm, and were co-registered to pre- and postcontrast fat suppressed images to define the region of interest. QPE was calculated. STATISTICAL TESTS: Receiver operating characteristic (ROC) analyses and kappa coefficients (k) were used to compare subjective BPE with QPE. RESULTS: ROC analyses indicated that subjective BPE at 90 s was best predicted by quantified QPE ≤20.2 = a, 20.3-25.2 = b, 25.3-50.0 = c, >50.0 = d, and at 180 s by quantified QPE ≤ 32.2 = a, 32.3-38.3 = b, 38.4-74.5 = c, >74.5 = d. Agreement between subjective BPE and QPE was slight to fair at 90 s (k = 0.20-0.36) and 180 s (k = 0.19-0.28). At higher levels of QPE, agreement between subjective BPE and QPE significantly decreased for all four radiologists at 90 s (P ≤ 0.004) and for three of four radiologists at 180 s (P ≤ 0.004). DATA CONCLUSION: Radiologists were less consistent with QPE as QPE increased. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:1685-1691.


Asunto(s)
Mama/diagnóstico por imagen , Imagen por Resonancia Magnética , Radiografía , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Medios de Contraste , Estudios Transversales , Femenino , Humanos , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador , Persona de Mediana Edad , Curva ROC , Adulto Joven
15.
Acad Radiol ; 24(12): 1544-1555, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-29122471

RESUMEN

RATIONALE AND OBJECTIVES: This study aimed to assess a novel method of three-dimensional (3D) co-registration of prostate magnetic resonance imaging (MRI) examinations performed before and after prostate cancer focal therapy. MATERIALS AND METHODS: We developed a software platform for automatic 3D deformable co-registration of prostate MRI at different time points and applied this method to 10 patients who underwent focal ablative therapy. MRI examinations were performed preoperatively, as well as 1 week and 6 months post treatment. Rigid registration served as reference for assessing co-registration accuracy and precision. RESULTS: Segmentation of preoperative and postoperative prostate revealed a significant postoperative volume decrease of the gland that averaged 6.49 cc (P = .017). Applying deformable transformation based on mutual information from 120 pairs of MRI slices, we refined by 2.9 mm (max. 6.25 mm) the alignment of the ablation zone, segmented from contrast-enhanced images on the 1-week postoperative examination, to the 6-month postoperative T2-weighted images. This represented a 500% improvement over the rigid approach (P = .001), corrected by volume. The dissimilarity by Dice index of the mapped ablation zone using deformable transformation vs rigid control was significantly (P = .04) higher at the ablation site than in the whole gland. CONCLUSIONS: Our findings illustrate our method's ability to correct for deformation at the ablation site. The preliminary analysis suggests that deformable transformation computed from mutual information of preoperative and follow-up MRI is accurate in co-registration of MRI examinations performed before and after focal therapy. The ability to localize the previously ablated tissue in 3D space may improve targeting for image-guided follow-up biopsy within focal therapy protocols.


Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Técnicas de Ablación , Anciano , Humanos , Aumento de la Imagen , Masculino , Programas Informáticos
16.
Clin Imaging ; 42: 119-125, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27951458

RESUMEN

PURPOSE: To evaluate clinical applicability of fibroglandular tissue (FGT) segmentation on routine T1 weighted breast MRI and compare FGT quantification with radiologist assessment. METHODS: FGT was segmented on 232 breasts and quantified, and was assessed qualitatively by four breast imagers. RESULTS: FGT segmentation was successful in all 232 breasts. Agreement between radiologists and quantified FGT was moderate to substantial (kappa=0.52-0.67); lower quantified FGT was associated with disagreement between radiologists and quantified FGT (P≤0.002). CONCLUSIONS: FGT segmentation was successful using routine T1 weighted breast MRI. Radiologists were less consistent with quantified results in breasts with lower quantified FGT.


Asunto(s)
Mama/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos
17.
Magn Reson Med ; 78(3): 1147-1156, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-27779790

RESUMEN

PURPOSE: Diffusion-weighted imaging (DWI) and 18 F-fluorodeoxyglucose-positron emission tomography (18 F-FDG-PET) independently correlate with malignancy in breast cancer, but the relationship between their structural and metabolic metrics is not completely understood. This study spatially correlates diffusion, perfusion, and glucose avidity in breast cancer with simultaneous PET/MR imaging and compares correlations with clinical prognostics. METHODS: In this Health Insurance Portability and Accountability Act-compliant prospective study, with written informed consent and approval of the institutional review board and using simultaneously acquired FDG-PET and DWI, tissue diffusion (Dt ), and perfusion fraction (fp ) from intravoxel incoherent motion (IVIM) analysis were registered to FDG-PET within 14 locally advanced breast cancers. Lesions were analyzed using 2D histograms and correlation coefficients between Dt , fp , and standardized uptake value (SUV). Correlations were compared with prognostics from biopsy, metastatic burden from whole-body PET, and treatment history. RESULTS: SUV||Dt correlation coefficient significantly distinguished treated (0.11 ± 0.24) from nontreated (-0.33 ± 0.26) patients (P = 0.005). SUV||fp correlations were on average negative for the whole cohort (-0.17 ± 0.13). CONCLUSION: Simultaneously acquired and registered FDG-PET/DWI allowed quantifiable descriptions of breast cancer microenvironments that may provide a framework for monitoring and predicting response to treatment. Magn Reson Med 78:1147-1156, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mama/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Femenino , Fluorodesoxiglucosa F18 , Humanos , Persona de Mediana Edad , Movimiento/fisiología
18.
J Comput Assist Tomogr ; 40(5): 827-32, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27224227

RESUMEN

OBJECTIVE: The aim of this study was to validate computed tomography (CT)-based longitudinal markers of the progression of Alzheimer disease (AD). MATERIALS AND METHODS: We retrospectively studied 33 AD patients and 39 nondemented patients with other neurological illnesses (non-AD) having 4 to 12 CT examinations of the head, with over a mean (SD) of 3.9 (1.7) years. At each time point, we applied an automatic software to measure whole brain, cerebrospinal fluid, and intracranial space volumes. Longitudinal measures were then related to disease status and time since the first scan using hierarchical models. RESULTS: Absolute brain volume loss accelerated for non-AD patients by 0.86 mL/y (95% confidence interval [CI], 0.64-1.08 mL/y) and 1.5× faster, that is, 1.32 mL/y (95% CI, 1.09-1.56 mL/y) for AD patients (P = 0.006). In terms of brain volume normalized to intracranial space, the acceleration in atrophy rate for non-AD patients was 0.0578%/y (95% CI, 0.0389%/y to 0.0767%/y), again 1.5× faster, that is, 0.0919%/y (95% CI, 0.0716%/y to 0.1122%/y) for AD patients (P = 0.017). This translates to an increase in atrophy rate from 0.5% to 1.4% in AD versus to 1.1% in non-AD group after 10 years. CONCLUSIONS: Brain volumetry on CT reliably detected accelerated volume loss in AD and significantly lower acceleration factor in age-matched non-AD patients, leading to the possibility of its use to monitor the progression of cognitive decline and dementia.


Asunto(s)
Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/patología , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Atrofia/diagnóstico por imagen , Atrofia/patología , Progresión de la Enfermedad , Femenino , Humanos , Estudios Longitudinales , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Técnica de Sustracción
19.
Radiology ; 280(3): 931-9, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27097236

RESUMEN

Purpose To identify the ability of computer-derived three-dimensional (3D) computed tomographic (CT) segmentation techniques to help differentiate lung adenocarcinoma subtypes. Materials and Methods This study had institutional research board approval and was HIPAA compliant. Pathologically classified resected lung adenocarcinomas (n = 41) with thin-section CT data were identified. Two readers independently placed over-inclusive volumes around nodules from which automated computer measurements were generated: mass (total mass) and volume (total volume) of the nodule and of any solid portion, in addition to the solid percentage of the nodule volume (percentage solid volume) or mass (percentage solid mass). Interobserver agreement and differences in measurements among pathologic entities were evaluated by using t tests. A multinomial logistic regression model was used to differentiate the probability of three diagnoses: invasive non-lepidic-predominant adenocarcinoma (INV), lepidic-predominant adenocarcinoma (LPA), and adenocarcinoma in situ (AIS)/minimally invasive adenocarcinoma (MIA). Results Mean percentage solid volume of INV was 35.4% (95% confidence interval [CI]: 26.2%, 44.5%)-higher than the 14.5% (95% CI: 10.3%, 18.7%) for LPA (P = .002). Mean percentage solid volume of AIS/MIA was 8.2% (95% CI: 2.7%, 13.7%) and had a trend toward being lower than that for LPA (P = .051). Accuracy of the model based on total volume and percentage solid volume was 73.2%; accuracy of the model based on total mass and percentage solid mass was 75.6%. Conclusion Computer-assisted 3D measurement of nodules at CT had good reproducibility and helped differentiate among subtypes of lung adenocarcinoma. (©) RSNA, 2016.


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/patología , Imagenología Tridimensional , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Tomografía Computarizada por Rayos X , Adenocarcinoma/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Neoplasias Pulmonares/cirugía , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Carga Tumoral
20.
MAGMA ; 29(2): 197-206, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26516082

RESUMEN

OBJECTIVE: To investigate the precision and accuracy of a new semi-automated method for kidney segmentation from single-breath-hold non-contrast MRI. MATERIALS AND METHODS: The user draws approximate kidney contours on every tenth slice, focusing on separating adjacent organs from the kidney. The program then performs a sequence of fully automatic steps: contour filling, interpolation, non-uniformity correction, sampling of representative parenchyma signal, and 3D binary morphology. Three independent observers applied the method to images of 40 kidneys ranging in volume from 94.6 to 254.5 cm(3). Manually constructed reference masks were used to assess accuracy. RESULTS: The volume errors for the three readers were: 4.4% ± 3.0%, 2.9% ± 2.3%, and 3.1% ± 2.7%. The relative discrepancy across readers was 2.5% ± 2.1%. The interactive processing time on average was 1.5 min per kidney. CONCLUSIONS: Pending further validation, the semi-automated method could be applied for monitoring of renal status using non-contrast MRI.


Asunto(s)
Algoritmos , Diabetes Mellitus Tipo 2/diagnóstico por imagen , Nefropatías Diabéticas/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Riñón/diagnóstico por imagen , Adulto , Medios de Contraste , Diabetes Mellitus Tipo 2/patología , Nefropatías Diabéticas/patología , Femenino , Humanos , Aumento de la Imagen/métodos , Riñón/patología , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Tamaño de los Órganos , Reconocimiento de Normas Patrones Automatizadas/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Interfaz Usuario-Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...