Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Med Sci Monit ; 30: e944050, 2024 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-38971968

RESUMEN

BACKGROUND Measurement of bite force plays a crucial role in assessment of the masticatory system. With a growing interest in detecting occlusal irregularities, bite force sensors have garnered attention in the biomedical field. This study aimed to introduce a hydrogel bite force sensor, based on hydroxyethyl-cellulose-fructose-water (HEC-F-water), for premolar and molar teeth, and to evaluate it using optical profilometry, infrared spectroscopy (FTIR), and Instron Tension testing system, with 2.5 cm (1 inch) margins at top, bottom, right, and left. MATERIAL AND METHODS We fabricated 20 HEC-F-water hydrogel samples sized with surface of 1×1 cm, with 2 different widths - 1 mm and 5 mm. The samples were characterized using optical profilometry and FTIR and their electrical characteristics were determined using an impedance analyzer. Aluminum (Al) electrodes, fabricated using Cutting Plotter, were used to form a HEC-F-water-based transducer, which was used for bite force sensing. The Instron tensile testing system was employed, utilizing 3D printed models of the upper and lower jaw, to simulate biting. Forces in the range between 40 N and 540 N were exerted upon the transducer, and the output change in the electrical signal was measured. RESULTS The study determined the transfer function between bite force and capacitance. The fabricated sensor exhibited a sensitivity of 3.98 pF/N, an input range of 500 N, output range of 2 nF, and accuracy of 95.9%. CONCLUSIONS This study introduces an edible bite force sensor employing an edible hydrogel as a dielectric, presenting a novel avenue in the development of edible sensorics in dentistry.


Asunto(s)
Fuerza de la Mordida , Humanos , Hidrogeles/química , Diente Molar , Fructosa , Masticación/fisiología , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Celulosa/química , Agua , Diente Premolar
2.
Sci Rep ; 13(1): 21277, 2023 12 02.
Artículo en Inglés | MEDLINE | ID: mdl-38042878

RESUMEN

Intraoral theranostics, the integration of diagnostics and therapeutics within the oral cavity, is gaining significant traction. This pioneering approach primarily addresses issues like xerostomia (dry mouth), commonly resulting from cancer treatment, with a specific focus on monitoring temperature and humidity. This paper introduces the innovative Intra-Oral Portable Micro-Electronic (IOPM) fluidic theranostic device platform. It leverages conventional dental spoons by incorporating advanced sensors for precise measurements of oral temperature and humidity. Personalization options include a microfluidic chip and a tooth model, enabling targeted delivery of therapeutic agents to optimize treatment outcomes. The electronic control system simplifies the administration of fluid dosages, intelligently adjusted based on real-time oral cavity temperature and humidity readings. Rigorous experimental evaluations validate the platform's precision in delivering fluid volumes at predefined intervals. This platform represents a transformative advancement for individuals contending with oral health challenges such as xerostomia (dry mouth). Furthermore, it has the potential to elevate oral healthcare standards by providing advanced diagnostics and tailored therapeutic solutions, benefiting both patients and dental professionals alike.


Asunto(s)
Xerostomía , Humanos , Temperatura , Humedad , Xerostomía/diagnóstico , Xerostomía/terapia , Examen Físico
3.
Front Public Health ; 11: 1279915, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37927882

RESUMEN

This systematic review and meta-analysis aimed to evaluate the ingestion of toothpaste and its sequelae. The study adhered to the PRISMA guidelines and was registered in the PROSPERO database. A comprehensive search strategy was conducted across multiple databases, resulting in the inclusion of 18 relevant publications. Eligible studies encompassed various designs and included both children and adults as the study population. Data extraction was carried out systematically, and relevant information on study characteristics, interventions, and outcomes were collected. The assessment of bias was performed using the Joanna Briggs Institute's Critical Appraisal Tools showing variations of bias among the included studies. The overall risk of systemic toxicity was found to be low, and no severe or life-threatening events were reported in the included studies. Furthermore, some toothpaste formulations containing higher concentrations of fluoride were associated with an increased risk of dental fluorosis. These findings have several implications for practice and policy. Healthcare providers and dental professionals should emphasize the importance of promoting safe toothpaste use, especially in vulnerable populations such as young children who are more prone to accidental ingestion. Public health campaigns and educational initiatives should aim to raise awareness about appropriate toothpaste usage and the potential risks. In addition, toothpaste manufacturers and regulatory bodies should consider revising guidelines and regulations to ensure the safety of oral care products, including the appropriate concentration of active ingredients. Future research should focus on investigating the long-term effects of toothpaste ingestion, exploring potential interactions between different active ingredients, and evaluating the efficacy of current preventive measures.


Asunto(s)
Fluoruros , Pastas de Dientes , Niño , Adulto , Humanos , Preescolar , Pastas de Dientes/efectos adversos , Fluoruros/efectos adversos , Promoción de la Salud , Personal de Salud , Ingestión de Alimentos
4.
Nanomaterials (Basel) ; 12(22)2022 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-36432311

RESUMEN

bioNEMS/MEMS has emerged as an innovative technology for the miniaturisation of biomedical devices with high precision and rapid processing since its first R&D breakthrough in the 1980s. To date, several organic including food waste derived nanomaterials and inorganic nanomaterials (e.g., carbon nanotubes, graphene, silica, gold, and magnetic nanoparticles) have steered the development of high-throughput and sensitive bioNEMS/MEMS-based biosensors, actuator systems, drug delivery systems and implantable/wearable sensors with desirable biomedical properties. Turning food waste into valuable nanomaterials is potential groundbreaking research in this growing field of bioMEMS/NEMS. This review aspires to communicate recent progress in organic and inorganic nanomaterials based bioNEMS/MEMS for biomedical applications, comprehensively discussing nanomaterials criteria and their prospects as ideal tools for biomedical devices. We discuss clinical applications for diagnostic, monitoring, and therapeutic applications as well as the technological potential for cell manipulation (i.e., sorting, separation, and patterning technology). In addition, current in vitro and in vivo assessments of promising nanomaterials-based biomedical devices will be discussed in this review. Finally, this review also looked at the most recent state-of-the-art knowledge on Internet of Things (IoT) applications such as nanosensors, nanoantennas, nanoprocessors, and nanobattery.

5.
Materials (Basel) ; 15(13)2022 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-35806658

RESUMEN

The aim of this study was to tackle the topic of appropriate recommendations for artificial-saliva and mouthwash usage. The contact angle, pH, and conductivity of two artificial saliva solutions, four mouthwashes, and their mixtures on enamel, glass-ionomer, and composite dental materials were measured. The measurements were conducted with a MATLAB algorithm to minimize human error. The obtained values for the contact angle were in the range from 7.98° to 52.6°, and they showed completely nonlinear and nonuniform behavior for all investigated liquids and on all investigated substrates. Results reveal statistically significant differences among all tested liquids on all investigated substrates (p < 0.05). pH values ranged from 1.54 to 7.01. A wide range of conductivity values were observed, from 1205µS/cm in the saliva-stimulating solution to 6679 mS/cm in the artificial saliva. Spearman's test showed a moderate positive correlation between the pH and conductivity of the tested fluids (R = 0.7108). A comparison of the data obtained using Image J software and the MATLAB algorithm showed consistency, not exceeding 5% error. When an experiment uses human material and bioactive materials THAT are used in biomedicine as substrates, an additional definition of protocols is highly recommended for future research on this topic.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...