Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
AJNR Am J Neuroradiol ; 44(3): 261-267, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36797031

RESUMEN

BACKGROUND AND PURPOSE: Automated volumetric analysis of structural MR imaging allows quantitative assessment of brain atrophy in neurodegenerative disorders. We compared the brain segmentation performance of the AI-Rad Companion brain MR imaging software against an in-house FreeSurfer 7.1.1/Individual Longitudinal Participant pipeline. MATERIALS AND METHODS: T1-weighted images of 45 participants with de novo memory symptoms were selected from the OASIS-4 database and analyzed through the AI-Rad Companion brain MR imaging tool and the FreeSurfer 7.1.1/Individual Longitudinal Participant pipeline. Correlation, agreement, and consistency between the 2 tools were compared among the absolute, normalized, and standardized volumes. Final reports generated by each tool were used to compare the rates of detection of abnormality and the compatibility of radiologic impressions made using each tool, compared with the clinical diagnoses. RESULTS: We observed strong correlation, moderate consistency, and poor agreement between absolute volumes of the main cortical lobes and subcortical structures measured by the AI-Rad Companion brain MR imaging tool compared with FreeSurfer. The strength of the correlations increased after normalizing the measurements to the total intracranial volume. Standardized measurements differed significantly between the 2 tools, likely owing to differences in the normative data sets used to calibrate each tool. When considering the FreeSurfer 7.1.1/Individual Longitudinal Participant pipeline as a reference standard, the AI-Rad Companion brain MR imaging tool had a specificity of 90.6%-100% and a sensitivity of 64.3%-100% in detecting volumetric abnormalities. There was no difference between the rate of compatibility of radiologic and clinical impressions when using the 2 tools. CONCLUSIONS: The AI-Rad Companion brain MR imaging tool reliably detects atrophy in cortical and subcortical regions implicated in the differential diagnosis of dementia.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Humanos , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Imagen por Resonancia Magnética/métodos , Corteza Cerebral , Programas Informáticos , Atrofia/patología , Procesamiento de Imagen Asistido por Computador/métodos , Reproducibilidad de los Resultados
2.
AJNR Am J Neuroradiol ; 42(8): E48-E52, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33926899

RESUMEN

The Accreditation Council for Graduate Medical Education is currently in the process of specialty-by-specialty revision of the Milestones. As a result, the Neuroradiology Milestones 2.0 Workgroup was created to refine a system of competency-based assessments for fellow educational growth and development. Strengths of the new Milestones include decreased complexity and uniformity within a subcompetency as it relates to a specific educational development trajectory. The Supplemental Guide serves to decrease clutter in the Milestones 2.0 document and provides a more practical resource for guidance. This article serves to review the history of the Neuroradiology Milestones, followed by a summary of the timeline of events and discussions of the workgroup for development of Neuroradiology Milestones 2.0 and a synopsis of major changes. The plan is for the updated Neuroradiology Milestones to take effect in 2021 or 2022 based on public commentary.


Asunto(s)
Competencia Clínica , Educación de Postgrado en Medicina , Acreditación , Humanos
3.
AJNR Am J Neuroradiol ; 30(3): 613-6, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19039044

RESUMEN

BACKGROUND AND PURPOSE: External beam radiation therapy (XRT) for head and neck cancer is known to induce hypothyroidism and cause morphologic changes in the thyroid gland. This retrospective study investigates change in the size of the thyroid gland detectable by CT after XRT for laryngeal cancer. MATERIALS AND METHODS: The measured width of the thyroid lobes in 61 patients treated nonsurgically with XRT for laryngeal cancer between 2000 and 2003 on posttherapy CT was compared with that on pretherapy CT. Absolute and percentage changes in measured thyroid width following XRT were analyzed according to chemotherapy administration and posttherapy thyroid function. RESULTS: Eighty-five percent (52/61) of patients had a decrease in the width of the thyroid gland. The average change in width measuring -4.7 mm and -13.8% (SD, 5.7 mm and 19.9%) occurred at an average of 758 days following completion of XRT (mean, 402-1534 days) and was significant (P = .002). Average change in width between hypothyroid patients (n = 19, -6.1 mm and -20.0% change) and euthyroid patients (n = 42, -4.1 mm and -11.1% change) was not significant (P = .20 absolute change and P = .11 percentage change). The average change in width between patients receiving chemotherapy (n = 31, -5.5 mm and -16.1% change) and patients not receiving chemotherapy (n = 30, -3.9 mm and -11.5% change) was not significant (P = .26 absolute change and P = .37 for percentage change). CONCLUSIONS: Most nonsurgical patients receiving XRT for laryngeal cancer have a significant decrease in the width of their thyroid glands detected on CT. The average change in the size of the thyroid gland does not differ when development of hypothyroidism or chemotherapy administration are considered.


Asunto(s)
Carcinoma de Células Escamosas/radioterapia , Hipotiroidismo/etiología , Neoplasias Laríngeas/radioterapia , Radioterapia/efectos adversos , Glándula Tiroides/patología , Glándula Tiroides/efectos de la radiación , Adulto , Anciano , Anciano de 80 o más Años , Antineoplásicos/uso terapéutico , Tumor Carcinoide/tratamiento farmacológico , Tumor Carcinoide/radioterapia , Carcinoma de Células Escamosas/tratamiento farmacológico , Terapia Combinada , Estudios de Seguimiento , Humanos , Hipotiroidismo/diagnóstico por imagen , Hipotiroidismo/patología , Neoplasias Laríngeas/tratamiento farmacológico , Persona de Mediana Edad , Tamaño de los Órganos/efectos de la radiación , Estudios Retrospectivos , Rabdomiosarcoma/tratamiento farmacológico , Rabdomiosarcoma/radioterapia , Glándula Tiroides/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...