Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
PLoS One ; 19(3): e0294897, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38512960

RESUMEN

BACKGROUND: SARS-CoV-2 variant Omicron rapidly evolved over 2022, causing three waves of infection due to sub-variants BA.1, BA.2 and BA.4/5. We sought to characterise symptoms and viral loads over the course of COVID-19 infection with these sub-variants in otherwise-healthy, vaccinated, non-hospitalised adults, and compared data to infections with the preceding Delta variant of concern (VOC). METHODS: In a prospective, observational cohort study, healthy vaccinated UK adults who reported a positive polymerase chain reaction (PCR) or lateral flow test, self-swabbed on alternate weekdays until day 10. We compared participant-reported symptoms and viral load trajectories between infections caused by VOCs Delta and Omicron (sub-variants BA.1, BA.2 or BA.4/5), and tested for relationships between vaccine dose, symptoms and PCR cycle threshold (Ct) as a proxy for viral load using Chi-squared (χ2) and Wilcoxon tests. RESULTS: 563 infection episodes were reported among 491 participants. Across infection episodes, there was little variation in symptom burden (4 [IQR 3-5] symptoms) and duration (8 [IQR 6-11] days). Whilst symptom profiles differed among infections caused by Delta compared to Omicron sub-variants, symptom profiles were similar between Omicron sub-variants. Anosmia was reported more frequently in Delta infections after 2 doses compared with Omicron sub-variant infections after 3 doses, for example: 42% (25/60) of participants with Delta infection compared to 9% (6/67) with Omicron BA.4/5 (χ2 P < 0.001; OR 7.3 [95% CI 2.7-19.4]). Fever was less common with Delta (20/60 participants; 33%) than Omicron BA.4/5 (39/67; 58%; χ2 P = 0.008; OR 0.4 [CI 0.2-0.7]). Amongst infections with an Omicron sub-variants, symptoms of coryza, fatigue, cough and myalgia predominated. Viral load trajectories and peaks did not differ between Delta, and Omicron, irrespective of symptom severity (including asymptomatic participants), VOC or vaccination status. PCR Ct values were negatively associated with time since vaccination in participants infected with BA.1 (ß = -0.05 (CI -0.10-0.01); P = 0.031); however, this trend was not observed in BA.2 or BA.4/5 infections. CONCLUSION: Our study emphasises both the changing symptom profile of COVID-19 infections in the Omicron era, and ongoing transmission risk of Omicron sub-variants in vaccinated adults. TRIAL REGISTRATION: NCT04750356.


Asunto(s)
COVID-19 , Adulto , Humanos , COVID-19/prevención & control , SARS-CoV-2 , Estudios Prospectivos , Vacunación
3.
Dent Mater ; 40(3): 466-476, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38142146

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the clinical performance of surface sealants associated with a bulk-fill composite in posterior restorations after 4 years. METHODS: A total of 174 posterior restorations were performed on 57 participants using a self-etch adhesive system and a bulk-fill composite. The groups were then divided into the following categories: 1) without surface sealant (NoS), 2) with surface sealant Biscover (Bisco, SBi), and 3) with surface sealant Permaseal (Ultradent, SPe). Restorations were evaluated using FDI criteria at baseline and after 1 and 4 years. Statistical analysis was conducted using Kaplan-Meier survival analysis and the Chi-square test (α = 0.05). RESULTS: After 4 years, only one restoration was lost (1 in the NoS group). The fracture/retention rate (with 95% confidence interval) was 98% for NoS and 100% for both SBi and SPe (p = 0.76). The majority of secondary outcomes showed minor defects, with no significant differences among the groups (p > 0.05). However, significant differences were observed among the groups in terms of marginal staining and marginal adaptation (p = 0.03). In both items, twelve restorations (nine in NoS, one in SBi, and two in SPe) showed minor marginal discrepancies favoring the sealant groups (SBi and SPe). SIGNIFICANCE: Regardless of the use of surface sealants, the bulk-fill composite restorations showed excellent clinical performance after 4 years. However, the groups that received sealants showed better marginal adaptation and less marginal discoloration compared to those that did not receive sealants.


Asunto(s)
Resinas Compuestas , Caries Dental , Humanos , Restauración Dental Permanente , Adaptación Marginal Dental , Materiales Dentales , Proyectos de Investigación
5.
Braz Oral Res ; 33: e083, 2019 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-31460609

RESUMEN

This study evaluated the influence of activation modes, on Diametral Tensile Strength (DTS) of dual cured resin cements subjected to a Mechanical Fatigue test (MF). Four dual-cured resin cements (RelyX UNICEM [U], RelyX ARC [A], ENFORCE [E] and Nexus 2 [N]) were activated by three different curing modes as follows: Self-Curing (SC), Dual Cure activation with photoactivation executed directly (DC) and Dual Cure activation with Photoactivation Through Porcelain (DCTP). After 24 hours, half of the sample was subjected to 30.000 fatigue cycles at 1 Hz frequency and 12 N load. Then, all specimens were subjected to DTS test in Instron Universal Testing Machine and data were analyzed by three-way ANOVA and Tukey's Test (5%). The results of DTS test means (MPa) and standard deviation, for each cement factor activated by SC, DC and DCTP was respectively: U (28.12 ± 5.29; 37.44 ± 6.49 and 40.10 ± 4.39), A (49.68 ± 8.42; 55.12 ± 5.16 and 63.43 ± 6.92), E (49.12 ± 3.89; 56.42 ± 8.88 and 56.96 ± 6.45) and N (61.89 ± 11.21; 59.26 ± 9.47 and 62.56 ± 10.93). Turkey's test indicated that DC is related to the highest DTS values; Nexus 2 DTS remained the same independently of activation mode and that the Porcelain disk interposition enhanced DTS only for RelyX ARC the ANOVA statistical test indicated that MF didn't alter the DTS values for all experimental groups. MF results clinical implication is that all cements tested exhibited, in an immediate loading, good cross linked bonds quality.


Asunto(s)
Bisfenol A Glicidil Metacrilato/química , Cerámica/química , Polietilenglicoles/química , Ácidos Polimetacrílicos/química , Cementos de Resina/química , Análisis de Varianza , Curación por Luz de Adhesivos Dentales/métodos , Ensayo de Materiales , Valores de Referencia , Reproducibilidad de los Resultados , Auto-Curación de Resinas Dentales/métodos , Resistencia a la Tracción
6.
AJR Am J Roentgenol ; 213(6): W277-W286, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31414892

RESUMEN

OBJECTIVE. The objective of our study was to compare the quality and diagnostic utility of the following three metal artifact reduction sequences in evaluating hip arthroplasties: conventional multiacquisition variable-resonance image combination selective (MAVRIC SL), isotropic MAVRIC SL, and reduced-TR isotropic MAVRIC SL. SUBJECTS AND METHODS. Ninety-three hip arthroplasties (85 total hip replacements and eight hip resurfacings [nine bilateral hips]) in 84 patients (38 men and 46 women; mean age ± SD, 69.1 ± 9.7 years old) were imaged and evaluated. A calibration scan determined the number of spectral bins needed for each implant, and isotropic and conventional MAVRIC SL images were acquired. Reduced-TR isotropic MAVRIC SL scans were acquired for 40 arthroplasties. Two board-certified radiologists blinded to MRI acquisition evaluated images for clinical and image quality features and compared images using a mixed-effects ordinal logistic regression model and odds ratios. Rater agreement was assessed with Gwet agreement coefficients. Scanning times were compared using mixed-effects linear regression. Significance was set at p < 0.05. RESULTS. Calibration scans decreased the number of bins needed (median, 12 bins; interquartile range, 10-16 bins). Isotropic MAVRIC SL (mean scanning time, 7 minutes 16 seconds; 95% CI, 7 minutes 7 seconds-7 minutes 25 seconds) acquisitions had the longest scanning time, and conventional (mean, 5 minutes 46 seconds; 95% CI, 5 minutes 37 seconds-5 minutes 55 seconds) and reduced-TR isotropic (5 minutes 28 seconds; 95% CI, 5 minutes 15 seconds-5 minutes 41 seconds) MAVRIC SL acquisitions had scanning times that were similar. Both isotropic and reduced-TR isotropic MAVRIC SL images showed decreased blurring and improved visualization of the synovium and periprosthetic bone compared with conventional MAVRIC SL images (p < 0.001). Isotropic MAVRIC SL acquisitions more effectively improved signal-to-noise ratio (SNR), visualization of the synovium and periprosthetic bone, and lesion conspicuity and decreased blurring compared with reduced-TR isotropic MAVRIC SL acquisitions (p < 0.032). CONCLUSION. Isotropic MAVRIC SL acquisitions improve SNR, conspicuity of lesions, and visualization of synovium and periprosthetic bone and decrease blurring compared with conventional MAVRIC SL acquisitions.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Femenino , Humanos , Masculino , Metales , Persona de Mediana Edad , Relación Señal-Ruido
7.
Rev. Cient. CRO-RJ (Online) ; 4(1): 97-101, Jan.-Apr. 2019.
Artículo en Inglés | LILACS, BBO | ID: biblio-1024331

RESUMEN

Introduction: In order to satisfy the aesthetic desires of the population, by masking the restorations was the search for the evolution of restorative materials enabling the introduction of metal-free materials. But previous studies that have been made with metal structures often cannot be removed and therefore require devices that can be masked, because there is no desire for a total passage of light avoiding dim reflection of these funds. For these situations, you must opt for a ceramic system to provide a degree of opacity, without losing its characteristics of light transmission, reflectance and saturation. Case report: In case the patient had clinical a metal ceramic crown on the molten core element 21, it was confirmed radiographically the core could not be removed because it would fracture risk to the tooth. We chose to use an opaquer ceramic framework to prevent the passage of light over dark metal. The material of choice was zirconia ceramic by high flexural strength, allowing it to function as a framework for crowns. Conclusion: With the correct application of ceramic coverage on Caquetá noted that it is possible to mask the gray color of the metal through the knowledge of the optical material, the correct use of these properties, opacity and translucidus, and a close contact between dentists and prosthetic.


Introdução: A fim de satisfazer os anseios estéticos, da população, por mascarar as restaurações houve a busca pela evolução dos materiais restauradores possibilitando a introdução de materiais livres de metais. Porém trabalhos prévios que foram confeccionados com estruturas metálicas muitas vezes não podem ser removidos e, portanto, necessitam de artifícios para que possam ser mascarados, pois não há o desejo de uma total passagem de luz evitando a reflexão desses fundos escurecidos. Para estas situações, é necessário optar por um sistema cerâmico que apresente um grau de opacidade, sem perda de suas características de translucidez, refletância e saturação. Relato do caso: A paciente possuía uma coroa metalo-cerâmica sobre núcleo fundido no elemento 21, constatou-se radiograficamente que o núcleo não podia ser retirado, pois traria risco de fratura ao dente. Optou-se por utilizar uma cerâmica mais opaca de arcabouço para evitar a passagem de luz sobre o metal escurecido. O material de escolha foi à cerâmica de zircônia por apresentar alta resistência à flexão, permitindo que funcione como arcabouço para coroas unitárias. Conclusão: Com a correta aplicação de cerâmicas de cobertura sobre o casquete observou- se que é possível mascarar a cor acinzentada do metal através dos conhecimentos ópticos do material, a correta utilização dessas propriedades, opacidade e translucides, e um estreito contato entre dentista e protético.


Asunto(s)
Estética Dental , Cerámica , Corona del Diente
8.
Clin Orthop Relat Res ; 477(1): 159-174, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30499779

RESUMEN

BACKGROUND: MRI is predictive of adverse local tissue reactions (ALTRs) after THA but how MRI directly relates to implant surface wear, fretting, and trunnion corrosion at different articulations between implant components remains unclear. MRI generates high-contrast images to display soft tissues around arthroplasty and may provide a surgeon the means to distinguish and differentiate host-related synovial patterns as a response to either polyethylene wear or metal wear and corrosion products. QUESTIONS/PURPOSES: The purposes of this study were (1) to correlate findings from MRI in patients who have undergone THA with direct assessment of implant wear, corrosion, and fretting from retrieved components; and (2) to distinguish the unique synovial responses on MRI in patients who have undergone THA based on bearing materials. METHODS: In this prospective study, patients undergoing THA (181 patients, 187 hips) with metal-on-metal (MoM), hip resurfacing (HRA), metal-on-polyethylene (MoP), ceramic-on-polyethylene, ceramic-on-ceramic, or modular neck designs having revision surgery (between October 2013 and June 2017) underwent preoperative MRI. A single reader blinded to the bearing surface made an assessment of the synovial response (Gwet's AC1, 0.65-0.97); these data were compared with semiquantitative histology of tissue samples by a single reader (Gwet's AC1, 0.92) and semiquantitative wear, corrosion, and fretting analysis of retrieved components using Goldberg scoring (Gwet's AC1, 0.60-0.79). Direct noncontact measurements of implant wear were also made. Correlations and analyses of variance were used to assess associations between metrics and differences by implant type, respectively. RESULTS: Correlations were found between MRI synovial thickness with severity of fretting and corrosion damage of the female head-neck trunnion of femoral stems in modular designs (ρ = 0.26 [95% confidence interval {CI}, 0.12-0.39]; p = 0.015, n = 185) and ALTR grade and volumetric wear in MoM bearings (ρ = 0.93 [95% CI, 0.72-0.98]; p < 0.001, n = 10). MRI synovial thickness was highest in patients identified with aseptic lymphocyte-dominated vasculitis-associated lesions and diffuse tissue necrosis. On MRI, MoP hips demonstrated a distinct polymeric synovial response, whereas HRA, MoM, and modular hips more commonly demonstrated ALTR. Hips classified as having a polymeric synovial response on MRI had a greater number of particles present in tissue samples. CONCLUSIONS: In this study, we demonstrated that MRI of THA can distinguish synovial responses that reflect the bearing type of the implanted THA and correlate to direct measurements of implant wear, corrosion, and fretting and histologic assessment of wear particles in periprosthetic tissues. MRI provides a means of direct, noninvasive visualization of the host-generated synovial response. Patients presenting with painful arthroplasties may be evaluated for the cause of their discomfort, specifically highlighting any concerning synovial reactions that would warrant more prompt surgical intervention. Future studies would benefit from a prospective evaluation of different implants to assess the natural longitudinal history of arthroplasty complications, including the development and prevalence of ALTR across bearing constructs. LEVEL OF EVIDENCE: Level III, diagnostic study.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Reacción a Cuerpo Extraño/diagnóstico por imagen , Articulación de la Cadera/cirugía , Prótesis de Cadera , Imagen por Resonancia Magnética , Falla de Prótesis , Adulto , Anciano , Estudios Transversales , Femenino , Reacción a Cuerpo Extraño/patología , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/patología , Articulación de la Cadera/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Estrés Mecánico , Propiedades de Superficie , Membrana Sinovial/diagnóstico por imagen , Membrana Sinovial/patología , Factores de Tiempo , Resultado del Tratamiento
9.
Braz. dent. sci ; 22(3): 378-386, 2019. tab, ilus
Artículo en Inglés | LILACS, BBO | ID: biblio-1009381

RESUMEN

Objective: The objective of this study was to evaluate the alteration of the optical properties of bulk fill resin-based composites after two years of simulated toothbrushing. Material and Methods: Three high-viscosity bulk fill resin composites and one conventional sculptable resin composite (control) were analyzed. Five specimens of each resin composite were prepared, and roughness, color, translucency and gloss were evaluated initially and after one and two years of simulated toothbrushing. The specimens were submitted to electric simulated toothbrushing (14600 strokes / 100 g) using a commercially available soft bristle toothbrush and toothpaste slurry in a proportion of 1:2 by weight. The brushing scheme was of 40 cycles per day (2 cycles per second / 280 cycles in a week). The optical properties and the roughness data were analyzed by a multifactor analysis of variance (MANOVA) and a Tukey post hoc test. Results: The baseline and final values of Ra and Sa were submitted to linear regression analyses, all of which were performed at a significance level of 5%. Gloss and roughness presented statistical differences between the resin-time interactions in all composite resins. The gloss (72.5%) and roughness (89.4%) worsened significantly after brushing, but the authors didn't find statistically significant differences when evaluating translucency and color. Conclusion: Based in the results, it could be concluded that the simulated brushing degraded the gloss and roughness of the used high-viscosity bulk fill composites. (AU)


Objetivo: O objetivo deste estudo foi avaliar a alteração das propriedades ópticas de resinas compostas do tipo bulk fill após dois anos de escovação simulada. Material e Métodos: Foram analisadas três resinas compostas do tipo bulk fill de alta viscosidade e uma resina composta convencional (controle). Cinco corpos-deprova de cada resina composta foram preparados e a rugosidade, cor, translucidez e brilho foram avaliados inicialmente e após um e dois anos de escovação simulada. Os espécimes foram submetidos a escovação dental simulada (14.600 golpes / 100 g) utilizando-se escova de dentes de cerdas macias comercialmente disponíveis e uma pasta composta de dentifrício e água na proporção de 1:2 em peso. O esquema de escovação foi de 40 ciclos por dia (2 ciclos por segundo / 280 ciclos por semana). As propriedades ópticas e os dados de rugosidade foram analisados por uma análise de variância multifatorial (MANOVA) e um teste post hoc de Tukey. Resultados: Os valores iniciais e finais de Ra e Sa foram submetidos a análises de regressão linear, todas realizadas ao nível de significância de 5%. O brilho e a rugosidade apresentaram diferenças estatísticas entre as interações resina-tempo em todas as resinas compostas. O brilho (72,5%) e a rugosidade (89,4%) pioraram significativamente após a escovação, mas os autores não encontraram diferenças estatisticamente significativas ao avaliar a translucidez e a cor. Conclusão: Com base nos resultados, pôde-se concluir que a escovação simulada degradou o brilho e a rugosidade das resinas compostas do tipo bulk fill avaliadas. (AU)


Asunto(s)
Cepillado Dental , Análisis de Varianza , Resinas Compuestas
10.
Braz. oral res. (Online) ; 33: e083, 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1019613

RESUMEN

Abstract This study evaluated the influence of activation modes, on Diametral Tensile Strength (DTS) of dual cured resin cements subjected to a Mechanical Fatigue test (MF). Four dual-cured resin cements (RelyX UNICEM [U], RelyX ARC [A], ENFORCE [E] and Nexus 2 [N]) were activated by three different curing modes as follows: Self-Curing (SC), Dual Cure activation with photoactivation executed directly (DC) and Dual Cure activation with Photoactivation Through Porcelain (DCTP). After 24 hours, half of the sample was subjected to 30.000 fatigue cycles at 1 Hz frequency and 12 N load. Then, all specimens were subjected to DTS test in Instron Universal Testing Machine and data were analyzed by three-way ANOVA and Tukey's Test (5%). The results of DTS test means (MPa) and standard deviation, for each cement factor activated by SC, DC and DCTP was respectively: U (28.12 ± 5.29; 37.44 ± 6.49 and 40.10 ± 4.39), A (49.68 ± 8.42; 55.12 ± 5.16 and 63.43 ± 6.92), E (49.12 ± 3.89; 56.42 ± 8.88 and 56.96 ± 6.45) and N (61.89 ± 11.21; 59.26 ± 9.47 and 62.56 ± 10.93). Turkey's test indicated that DC is related to the highest DTS values; Nexus 2 DTS remained the same independently of activation mode and that the Porcelain disk interposition enhanced DTS only for RelyX ARC the ANOVA statistical test indicated that MF didn't alter the DTS values for all experimental groups. MF results clinical implication is that all cements tested exhibited, in an immediate loading, good cross linked bonds quality.


Asunto(s)
Polietilenglicoles/química , Ácidos Polimetacrílicos/química , Cerámica/química , Bisfenol A Glicidil Metacrilato/química , Cementos de Resina/química , Valores de Referencia , Resistencia a la Tracción , Ensayo de Materiales , Reproducibilidad de los Resultados , Análisis de Varianza , Auto-Curación de Resinas Dentales/métodos , Curación por Luz de Adhesivos Dentales/métodos
11.
Gen Dent ; 65(5): e17-e22, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28862597

RESUMEN

In this in vitro study, 3 experiments were conducted to evaluate the influence of customizing the apical portion on the characteristics of fiber posts. In the first experiment, 4 fiber posts were submitted to different custom adaptations (no customization, industrial shaping tool, diamond bur, or paper disc) and were observed with a scanning electron microscope to evaluate the micromorphologic changes. In the second experiment, 60 posts of different sizes were divided into 6 groups (n = 10): 0 (No. 0.5), 1 (No. 1), 2 (No. 2), 3 (No. 3), 4 (No. 4), and 5 (paper disc-remodeled No. 4). The posts were submitted to a 3-point bending test. In the third experiment, the crowns of 20 extracted, healthy permanent human canines were removed, and the teeth were endodontically treated, embedded in acrylic resin, and divided into 2 groups (n = 10): I (control), No. 4 posts cemented into post spaces prepared with a No. 4 drill; and II (test), remodeled No. 4 posts cemented into root spaces prepared with No. 2 and 4 drills. The posts were cemented with self-adhesive dual resin cement, and the specimens received direct resin crowns. Fracture strength was measured with a universal testing machine at 45 degrees until fracture. Results were submitted to analysis of variance (P ≤ 0.05). Customization of fiber posts with diamond burs or paper discs produced acceptable micromorphologic changes. Custom adaptation of fiber posts reduced their flexural strength, which remained at acceptable values. Teeth restored with customized fiber posts had greater fracture strength than those restored with intact posts. The results of this study indicated that post remodeling is a safe means to facilitate adaptation to root walls and preserve tooth structure.


Asunto(s)
Técnica de Perno Muñón , Ápice del Diente , Coronas , Cementos Dentales , Materiales Dentales/química , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Humanos , Técnicas In Vitro , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Cementos de Resina/química
12.
Int J Dent ; 2017: 4646789, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28932242

RESUMEN

PURPOSE: The purpose of this study was to evaluate changes in calcium and phosphorus content in dental enamel when subjected to "in-office" whitening for an extended time by using a 35% hydrogen peroxide solution, with and without calcium. MATERIALS AND METHODS: 10 human teeth, from which the roots had been removed, were embedded in epoxy resin, and their surfaces were smoothed. The specimens were divided into two groups; in group 1, a whitening solution without calcium was used, while in group 2, the solution included calcium. Each specimen was evaluated at 6 different points before the bleaching treatment, and these points were reassessed after each session. A total of five sessions were carried out. Concentrations of calcium and phosphorus were measured by using the technique of X-ray fluorescence. RESULTS: After performing a statistical analysis, it was found that there was no statistically significant loss of calcium and phosphorus during the whitening treatment, and the groups showed no statistical differences. CONCLUSION: Excessive use of hydrogen peroxide, with or without calcium, causes no loss of calcium and phosphorus.

13.
Braz. dent. j ; 27(3): 359-362, May-June 2016. graf
Artículo en Inglés | LILACS | ID: lil-782820

RESUMEN

Abstract The aim of this paper was to describe a clinical case of immediate dental desensitization using a self-etch adhesive system in an adolescent patient diagnosed with amelogenesis imperfecta (AI). AI was associated with severe tooth sensitivity, treated by the application of a universal adhesive system for desensitization of the teeth affected by AI. Reduction of tooth sensitivity was assessed using a visual analog scale during all reevaluations. The technique was effective for reducing tooth sensitivity. It was concluded that the adhesive system for tooth desensitization had an immediate effect and maintained its effectiveness during a 12-month follow-up period.


Resumo O objetivo deste estudo foi descrever uma técnica de dessensibilização dental imediata, usando o adesivo universal em paciente adolescente diagnosticado com amelogênese imperfeita. O paciente afetado pela amelogênese imperfeita apresentava dentes extremamente sensíveis, e foi submetido a aplicações de adesivo universal para dessensibilizar os dentes afetados por amelogênese imperfeita. A redução da sensibilidade dentária foi avaliada pela escala analógica visual durante todas as reavaliações. A técnica foi efetiva na redução da sensibilidade dental. Concluiu-se que o uso do sistema adesivo foi eficaz na imediata dessensibilidazação dentária e mantida após doze meses de avaliação.


Asunto(s)
Humanos , Masculino , Niño , Amelogénesis Imperfecta/tratamiento farmacológico , Cementos Dentales/uso terapéutico , Escala Visual Analógica
14.
Braz Dent J ; 27(3): 359-62, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27224574

RESUMEN

The aim of this paper was to describe a clinical case of immediate dental desensitization using a self-etch adhesive system in an adolescent patient diagnosed with amelogenesis imperfecta (AI). AI was associated with severe tooth sensitivity, treated by the application of a universal adhesive system for desensitization of the teeth affected by AI. Reduction of tooth sensitivity was assessed using a visual analog scale during all reevaluations. The technique was effective for reducing tooth sensitivity. It was concluded that the adhesive system for tooth desensitization had an immediate effect and maintained its effectiveness during a 12-month follow-up period.


Asunto(s)
Amelogénesis Imperfecta/tratamiento farmacológico , Cementos Dentales/uso terapéutico , Niño , Humanos , Masculino , Escala Visual Analógica
15.
Int J Dent ; 2016: 9319534, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27143971

RESUMEN

The present study evaluated the influence of the cement film thickness on the push-out bond strength of glass fiber posts in the cervical, medium, and apical thirds of root canal spaces. Thirty roots were randomly divided into three groups, according to the fiber post system's drills: (G1) #2; (G2) #3; (G3) #4. The posts were cemented using a self-adhesive cement, and a small amount of powdered Rhodamine B was used as a stain. Images of both sides of each slice were obtained before and after the push-out test. To determine the cement thickness, a macro routine was developed using the software KS 400. The data were analyzed statistically using Kruskal-Wallis and Dunn's test. G2 (14.62 ± 5.15 MPa) showed statistically higher bond strength values than G1 (10.04 ± 5.13 MPa) and G3 (7.68 ± 6.14 MPa). All groups presented higher bond strength values in the apical third. The bur diameter significantly influenced the results of the shear bond strength for the push-out test. The slight increase in the cement thickness allowed an increase in the values of shear bond strength when compared to very thin or very thick cement films.

16.
J Prosthet Dent ; 114(2): 278-85, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25882976

RESUMEN

STATEMENT OF THE PROBLEM: Fixed prosthesis and partial dental prosthesis frameworks are usually made from welded Ni-Cr-based alloys. These structures can corrode in saliva and have to be investigated to establish their safety. PURPOSE: The purpose of this study was to evaluate the corrosion behavior of joints joined by tungsten inert gas (TIG) welding and conventional brazing in specimens made of commercial Ni-Cr alloy in Fusayama artificial saliva at 37°C (pH 2.5 and 5.5). MATERIAL AND METHODS: Eighteen Ni-Cr base metal specimens were cast and welded by brazing or tungsten inert gas methods. The specimens were divided into 3 groups (base metal, 2 welded specimens), and the composition and microstructure were qualitatively evaluated. The results of potential corrosion and corrosion current density were analyzed with a 1-way analysis of variance and the Tukey test for pairwise comparisons (α=.05). RESULTS: Base metal and tungsten inert gas welded material showed equivalent results in electrochemical corrosion tests, while the air-torched specimens exhibited low corrosion resistance. The performance was worst at pH 2.5. CONCLUSIONS: These results suggest that tungsten inert gas is a suitable welding process for use in dentistry, because the final microstructure does not reduce the corrosion resistance in artificial saliva at 37°C, even in a corrosion-testing medium that facilitates galvanic corrosion processes. Moreover, the corrosion current density of brazed Ni-Cr alloy joints was significantly higher (P<.001) than the base metal and tungsten inert gas welded joints.


Asunto(s)
Argón , Aleaciones de Cromo/química , Soldadura Dental/métodos , Saliva Artificial/química , Tungsteno , Grabado Ácido Dental/métodos , Aire , Aleaciones de Cromo/análisis , Corrosión , Pulido Dental/métodos , Espectroscopía Dieléctrica , Electroquímica , Calor , Ácido Clorhídrico/química , Concentración de Iones de Hidrógeno , Ensayo de Materiales , Metalurgia/métodos , Microscopía Electrónica de Rastreo , Ácido Nítrico/química , Espectrometría por Rayos X , Temperatura
17.
Dent Mater J ; 33(6): 770-7, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25311334

RESUMEN

The bond strength of dental materials has been evaluated by tensile testing of micro-specimens. The cutting process used to obtain specimens may influence the results. The objective of this study was to investigate the influence of different types of diamond disks and cutting speeds on the bond strength of ceramic specimens and on specimen integrity. Lithium disilicate-based ceramic cubes were bonded with resin cement to composite resin cubes, according to the manufacturers' instructions. The ceramic/cement/resin blocks thus obtained were divided into two groups to be cut with Buehler(®) or Extec(®) disks and then sectioned at cutting speeds of 200 rpm and 400 rpm. The results showed that the bond strength values were affected by the cutting speed and disk/speed interaction (p<0.05). SEM analysis revealed better specimen properties when the blocks were cut at 200 rpm. It was concluded that ceramic specimens must be cut at low speeds.


Asunto(s)
Resinas Compuestas/química , Cementos de Resina/química , Dióxido de Silicio/química , Circonio/química , Bisfenol A Glicidil Metacrilato/química , Instrumentos Dentales , Materiales Dentales , Porcelana Dental , Análisis del Estrés Dental , Diamante , Curación por Luz de Adhesivos Dentales , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Polietilenglicoles/química , Ácidos Polimetacrílicos/química , Resistencia a la Tracción
18.
Dental Press J Orthod ; 18(3): 54-62, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24094012

RESUMEN

INTRODUCTION: The shear bond strength of orthodontic brackets bonded to micro-hybrid and micro-particulate resins under different surface treatment methods was assessed. METHODS: Two hundred and eighty test samples were divided into 28 groups (n = 10), where 140 specimens were filled with Durafill micro-particulate resin and 140 with Charisma composite. In 140 samples, a coupling agent (silane) was applied. The surface treatment methods were: Phosphoric and hydrofluoric acid etching, sodium bicarbonate and aluminum oxide blasting, stone and burs. A Universal Instron Machine was used to apply an occlusal shear force directly to the resin composite bracket surface at a speed of 0.5 mm/min. The means were compared using analysis of variance and multivariate regression to assess the interaction between composites and surface treatment methods. RESULTS: Means and standard deviations for the groups were: Sodium bicarbonate jet 11.27 ± 2.78; burs 9.26 ± 3.01; stone 7.95 ± 3.67; aluminum oxide blasting 7.04 ± 3.21; phosphoric acid 5.82 ± 1.90; hydrofluoric acid 4.54 ± 2.87, and without treatment 2.75 ± 1.49. An increase of 1.94 MPa in shear bond strength was seen in Charisma groups. Silane agent application reduced the Charisma shear bond strength by 0.68 Mpa, but increased Durafill means for bicarbonate blasting (0.83), burs (0.98) and stone drilling (0.46). CONCLUSIONS: The sodium bicarbonate blasting, burs and stone drilling methods produced adequate shear bond strength and may be suitable for clinical use. The Charisma micro hybrid resin composite showed higher shear bond means than Durafill micro particle composite.


Asunto(s)
Grabado Ácido Dental , Abrasión Dental por Aire/métodos , Recubrimiento Dental Adhesivo , Análisis del Estrés Dental , Soportes Ortodóncicos , Silanos , Análisis de Varianza , Resinas Compuestas , Análisis de Regresión , Resistencia al Corte , Bicarbonato de Sodio , Propiedades de Superficie
19.
Dental press j. orthod. (Impr.) ; 18(3): 54-62, May-June 2013. ilus, graf, tab
Artículo en Inglés | LILACS | ID: lil-689998

RESUMEN

INTRODUCTION: The shear bond strength of orthodontic brackets bonded to micro-hybrid and micro-particulate resins under different surface treatment methods was assessed. METHODS: Two hundred and eighty test samples were divided into 28 groups (n = 10), where 140 specimens were filled with Durafill micro-particulate resin and 140 with Charisma composite. In 140 samples, a coupling agent (silane) was applied. The surface treatment methods were: Phosphoric and hydrofluoric acid etching, sodium bicarbonate and aluminum oxide blasting, stone and burs. A Universal Instron Machine was used to apply an occlusal shear force directly to the resin composite bracket surface at a speed of 0.5 mm/min. The means were compared using analysis of variance and multivariate regression to assess the interaction between composites and surface treatment methods. RESULTS: Means and standard deviations for the groups were: Sodium bicarbonate jet 11.27±2.78; burs 9.26±3.01; stone 7.95±3.67; aluminum oxide blasting 7.04±3.21; phosphoric acid 5.82±1.90; hydrofluoric acid 4.54±2.87, and without treatment 2.75±1.49. An increase of 1.94 MPa in shear bond strength was seen in Charisma groups. Silane agent application reduced the Charisma shear bond strength by 0.68 Mpa, but increased Durafill means for bicarbonate blasting (0.83), burs (0.98) and stone drilling (0.46). CONCLUSION: The sodium bicarbonate blasting, burs and stone drilling methods produced adequate shear bond strength and may be suitable for clinical use. The Charisma micro hybrid resin composite showed higher shear bond means than Durafill micro particle composite.


INTRODUÇÃO: foram avaliadas as forças de cisalhamento após colagem de braquetes ortodônticos em superfícies resinosas microparticuladas ou micro-híbridas, após diferentes tratamentos de superfície. MÉTODOS: foram utilizados 280 corpos de prova, divididos em grupos de 10 elementos cada, sendo 140 preenchidos com resina microparticulada Durafill e 140 com resina micro-híbrida Charisma. Os tratamentos de superfície envolveram: ácido fosfórico, ácido fluorídrico, jato de bicarbonato de sódio, jato de óxido de alumínio, pedra e broca. A silanagem foi utilizada em metade dos grupos. O cisalhamento foi realizado com a máquina universal de testes EMIC DL 10000 MF, com célula de 10kg e velocidade de 0,5mm/min. As comparações entre as forças de cisalhamento foram obtidas por meio da análise de variância, e o grau de interação entre os tipos de compósito e o preparo de superfície foram obtidos por meio de uma regressão multivariada. RESULTADOS: as médias e desvios-padrão foram: jato de bicarbonato = 11,27 ± 2,78; broca = 9,26 ± 3,01; pedra = 7,95 ± 3,67; jato de óxido de alumínio = 7,04 ± 3,21; ácido fosfórico = 5,82 ± 1,90; ácido fluorídrico = 4,54 ± 2,87; e sem preparo = 2,75 ± 1,49. Um acréscimo de 1,94MPa foi obtido com o uso do compósito Charisma. A silanagem reduziu em 0,68MPa as médias do compósito Charisma, e aumentou o Durafill com uso do jato de bicarbonato (0,83), broca (0,98) e pedra (0,46). CONCLUSÃO: os preparos com jato de bicarbonato, broca e pedra obtiveram médias de forças apropriadas para colagem. O compósito Charisma apresentou forças de maior intensidade que as da resina Durafill.


Asunto(s)
Grabado Ácido Dental , Abrasión Dental por Aire/métodos , Recubrimiento Dental Adhesivo , Análisis del Estrés Dental , Soportes Ortodóncicos , Silanos , Análisis de Varianza , Resinas Compuestas , Análisis de Regresión , Resistencia al Corte , Bicarbonato de Sodio , Propiedades de Superficie
20.
Rev. dental press estét ; 10(1): 89-95, jan.-mar .2013. ilus
Artículo en Portugués | LILACS | ID: lil-681622

RESUMEN

Atualmente, a cimentação adesiva de pinos pré-fabricados reforçados por fibras em condutos radiculares é um procedimento comum na prática clínica. No entanto, muitas vezes o pino não se adapta ao conduto e um desgaste excessivo de estrutura dentária é realizado no intuito de promover uma melhor adaptação, ou um pino de menor diâmetro é selecionado, formando um filme de cimento muito espesso. Sendo assim, o presente estudo visa colaborar com os profissionais da área de Odontologia por meio de uma revisão de literatura que possui como objetivo discutir sobre a união de pinos cimentados em canais radiculares, além de abordar sobre pinos reforçados por fibras e cimentação adesiva


Currently, adhesive cementation of prefabricated fber reinforced posts in root canals is a common procedure in clinical practice. However, often the post does not ft precisely to the root canal and excessive wear of tooth structure is carried out in order to promote a better ft, or a post with smaller diameter is selected creating greater cement flm thickness. Therefore, this study aims to collaborate with professionals in dentistry through a literature review that discuss the influence of cement flm thickness on the bond strength of posts cemented in root canals, besides addressing on fber reinforced posts and adhesive cementation.


Asunto(s)
Humanos , Pins Dentales , Restauración Dental Permanente , Estética Dental , Técnica de Perno Muñón , Cementos de Resina , Preparación del Conducto Radicular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...