Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
BMC Anesthesiol ; 23(1): 386, 2023 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-38007426

RESUMEN

BACKGROUND: Incomplete sealing of tracheal diverticula by a tracheal tube cuff during positive-pressure ventilation causes barotrauma but the concrete possibility of incomplete sealing has not been indicated. We aimed to assess the possibility of incomplete sealing in a simulated situation of tracheal intubation for patients with tracheal diverticula with tube fixation where the tracheal tube's vocal cord guide overlaps with the patient's vocal cord. METHODS: We retrospectively assessed the characteristics of tracheal diverticula based on thoracic computed tomography data in our institution from January 2018 to July 2020. Then, we assessed the structural parameters of three single-lumen tracheal tubes (Parker Flex-Tip [Parker Medical, Bridgewater, CT, USA], Portex Soft Seal [ICU Medical, San Clemente, CA, USA], and Shiley TaperGuard [Medtronic, Dublin, Ireland]; 6.0-8.0 mm inner diameter size) and simulated the positional relationships between tracheal diverticula and the tracheal tube during tracheal intubation where the vocal cord guide overlaps with the patient's vocal cord. We assessed each tube product's possibility of incompletely sealing tracheal diverticula and the possibility of unintended bronchial intubation. RESULTS: In 5,854 patients, the prevalence of tracheal diverticula was 5.7%. The mean (SD) length from the vocal cord to the distal end of the tracheal diverticula was 52.2 (12.8) mm. Tracheal tubes with length from the distal end of the tracheal cuff to the vocal cord guide of ≥ 70 mm had a low risk of incompletely sealing tracheal diverticula (< 5%) and length from the distal end of the tube to the vocal cord guide of ≤ 95 mm had a low risk of unintended bronchial intubation (< 5%). No products in this study satisfied both outcomes. CONCLUSIONS: Tube fixation, where the vocal cord guide overlaps with the patient's vocal cord, is associated with risk of incompletely sealing of tracheal diverticula depending on the tube's manufacturer and tube's inner diameter size, although it was not a high risk. The use of small inner diameter sized tube relative to patient's body size is high risk of incomplete sealing of tracheal diverticula. TRIAL REGISTRATION: This trial was prospectively registered at University Hospital Medical Information Network (UMIN). CLINICAL TRIAL NUMBER AND REGISTRY URL: UMIN000043317 (URL: https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000048055 ).


Asunto(s)
Divertículo , Enfermedades de la Tráquea , Humanos , Anestesia General , Intubación Intratraqueal/métodos , Respiración Artificial/métodos , Estudios Retrospectivos , Enfermedades de la Tráquea/terapia
2.
J Anesth ; 37(6): 841-852, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37597005

RESUMEN

PURPOSE: Generation of nociceptive sensory evoked potentials (NEPs) by selective stimulation of nociceptive intraepidermal nerve fibers is a simple technique which could be used as intraoperative nociception monitor. We evaluated the effects of remifentanil, propofol and sevoflurane on NEPs by this technique. METHODS: Patients undergoing general anesthesia were assigned to groups in two studies. A-δ fiber selective NEPs were recorded. Study 1: NEPs were recorded at control, under anesthetics administration: remifentanil at an effect-site concentration (Ce) of 1.0 ng/mL (n = 10), propofol at Ce of 0.5 µg/mL (n = 10), or sevoflurane at 0.2 minimum alveolar concentration (MAC) (n = 10), and recovery from the anesthetics. Study 2: NEPs were recorded at control and under administration of higher dose anesthetics: propofol at Ce of 0.5 and 1.0 µg/mL (n = 10) or sevoflurane at 0.2 and 0.5 MAC (n = 10). A P-value < 0.016 was considered statistically significant in multiple analyses. RESULTS: Study 1: Remifentanil at Ce of 1.0 ng/mL significantly suppressed the amplitude of NEPs (mean amplitude (standard deviation) of control vs. remifentanil administration: 16.8 µV (3.8) vs. 10.1 µV (2.5), P < 0.001). Propofol and sevoflurane did not suppress the amplitude significantly. Study 2: Propofol at Ce of 0.5 and 1.0 µg/mL and sevoflurane at 0.2 and 0.5 MAC did not suppress the amplitude significantly. CONCLUSION: The amplitude of A-δ fiber selective NEPs was suppressed by remifentanil but not propofol or sevoflurane. NEPs with intraepidermal electrical stimulation can assess the analgesic effect of anesthetics. CLINICAL TRIAL NUMBER: UMIN000038214 REGISTRY URL: https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000043328.


Asunto(s)
Anestésicos por Inhalación , Éteres Metílicos , Propofol , Humanos , Propofol/farmacología , Sevoflurano , Remifentanilo , Anestésicos Intravenosos/farmacología , Éteres Metílicos/farmacología , Anestésicos por Inhalación/farmacología , Nocicepción , Piperidinas/farmacología , Potenciales Evocados , Estimulación Eléctrica
3.
Case Rep Surg ; 2017: 3403045, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28529813

RESUMEN

Robotic surgery with carbon dioxide (CO2) insufflation to the thorax is frequently performed to gain a better operative field of view, although its intraoperative complications have not yet been discussed in detail. We treated two patients with difficult ventilation caused by distal migration of a double-lumen endotracheal tube (DLT) during robotic thymectomy. In the first case, migration of the DLT during one-lung ventilation (OLV) occurred after CO2 insufflation to the bilateral thoraxes was started. Oxygenation rapidly deteriorated because dependent lung expansion was restricted by CO2 insufflation. In the second case, migration of the DLT during OLV occurred while CO2 insufflation to a unilateral thorax and mediastinum was performed. In both cases, once migration of the DLT during OLV occurred with CO2 insufflation, readjusting the DLT became very difficult because our manipulation of bronchofiberscopy was prevented by the robot arms located above the patient's head and because deformation of the trachea/bronchus induced by CO2 insufflation caused a poor image of the bronchofiberscopic view. Thus, during robotic-assisted thoracoscopic surgery with CO2 insufflation, since there is a potential risk of difficult ventilation with a DLT and since readjustment of the DLT is very difficult, discontinuing CO2 insufflation and switching to double-lung ventilation are needed in such a situation.

4.
JA Clin Rep ; 3(1): 20, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29457064

RESUMEN

BACKGROUND: Since acute respiratory failure (ARF) is a life-threatening complication, particularly in the gestational period, differential diagnosis and rapid treatment are required. Among the various causes of sudden onset of ARF, thyroid storm is a rare cause in a parturient complicated with well-controlled hyperthyroidism. In this case report, we describe a parturient with hyperthyroidism in whom a thyroid storm manifesting congestive heart failure and pulmonary edema developed just before an emergency ceasarean section, even though hyperthyroidism was well-controlled with antithyroid drugs. CASE PRESENTATION: A 36-year-old pregnant woman was diagnosed as having clinical chorioamnionitis, and an emergency cesarean section was performed at 25 weeks of pregnancy. She had a complication of hyperthyroidism accompanied by mild mitral regurgitation, and she had been treated with methimazole. She was treated with ritodrine and MgSO4 for the threat of premature delivery. At the preoperative consultation, her percutaneous oxygen saturation (SpO2) was 98% on room air. When she was admitted to the operating room, her heart rate and blood pressure were 130 beats/min and 196/78 mmHg, respectively. SpO2 was 88% on room air without any symptoms; however, just after starting oxygen administration via a facemask, she complained of severe respiratory distress and became agitated. Partial pressure of arterial oxygen was 108 mmHg with an inspiratory oxygen fraction of 1.0. Chest radiography revealed pulmonary congestion, and transesophageal echocardiography revealed normal right ventricular function without an embolus and severe mitral regurgitation with preserved left ventricular function. Contrast-enhanced computed tomography after the operation revealed no pulmonary embolus but revealed a pulmonary effusion, and free triiodothyronine level was increased at the onset of dyspnea. Therefore, we diagnosed the causes of sudden onset of dyspnea as pulmonary edema and congestive heart failure induced by a thyroid storm. CONCLUSION: Sudden onset of a thyroid storm just before a cesarean section occurred in a patient with several risk factors of thyroid storm and pulmonary edema, including pregnancy, treatment with tocolytic agents, and infection. The involvement of these multiple factors was considered to be the cause of the sudden onset of the thyroid storm and the cause of rapidly progressive pulmonary edema.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...