Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Int J Cardiovasc Imaging ; 40(4): 853-862, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38236362

RESUMEN

This methodological study aimed to validate the cardiac output (CO) measured by exercise-stress real-time phase-contrast cardiovascular magnetic resonance imaging (CMR) in patients with heart failure and preserved ejection fraction (HFpEF). 68 patients with dyspnea on exertion (NYHA ≥ II) and echocardiographic signs of diastolic dysfunction underwent rest and exercise stress right heart catheterization (RHC) and CMR within 24 h. Patients were diagnosed as overt HFpEF (pulmonary capillary wedge pressure (PCWP) ≥ 15mmHg at rest), masked HFpEF (PCWP ≥ 25mmHg during exercise stress but < 15mmHg at rest) and non-cardiac dyspnea. CO was calculated using RHC as the reference standard, and in CMR by the volumetric stroke volume, conventional phase-contrast and rest and stress real-time phase-contrast imaging. At rest, the CMR based CO showed good agreement with RHC with an ICC of 0.772 for conventional phase-contrast, and 0.872 for real-time phase-contrast measurements. During exercise stress, the agreement of real-time CMR and RHC was good with an ICC of 0.805. Real-time measurements underestimated the CO at rest (Bias:0.71 L/min) and during exercise stress (Bias:1.4 L/min). Patients with overt HFpEF had a significantly lower cardiac index compared to patients with masked HFpEF and with non-cardiac dyspnea during exercise stress, but not at rest. Real-time phase-contrast CO can be assessed with good agreement with the invasive reference standard at rest and during exercise stress. While moderate underestimation of the CO needs to be considered with non-invasive testing, the CO using real-time CMR provides useful clinical information and could help to avoid unnecessary invasive procedures in HFpEF patients.


Asunto(s)
Gasto Cardíaco , Prueba de Esfuerzo , Insuficiencia Cardíaca , Valor Predictivo de las Pruebas , Volumen Sistólico , Función Ventricular Izquierda , Humanos , Femenino , Masculino , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico por imagen , Anciano , Persona de Mediana Edad , Reproducibilidad de los Resultados , Cateterismo Cardíaco , Imagen por Resonancia Cinemagnética , Factores de Tiempo , Disnea/fisiopatología , Disnea/etiología , Disnea/diagnóstico por imagen , Función Ventricular Derecha
2.
Eur J Microbiol Immunol (Bp) ; 8(4): 159-162, 2018 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-30719334

RESUMEN

INTRODUCTION: To prevent surgical site infections (SSIs) during operation, the use of sterile surgical latex gloves is common. The aim of this study was to examine the damage of the gloves in surgeries with different mechanical stress and the influence on the kind of damages. Gloves were collected during primary arthroplasty, revision arthroplasty (hip and knee), and arthroscopy (shoulder, hip, and knee). MATERIALS AND METHODS: Surgical latex operation gloves were collected from surgeons after the operation and were tested with watertightness test (ISO EN 455-1:2000). RESULTS: A total of 1460 surgical gloves were retrieved from 305 elective operations. On average, 15.9% of the gloves showed postoperative lesions, with the highest incidence occurring in revision arthroplasty with 25%. In primary and revision arthroplasty, the index finger of the dominant hand was most frequently affected (62.7% and 58.6%); in contrast, gloves from arthroscopies had most lesions on thumb and middle finger (42.9% each). Tear and perforation size differed from ≤1 mm to >5 mm, and primary and revision arthroplasty showed bigger damages. CONCLUSIONS: Surgical gloves have a high malfunction, which increases with growing mechanical stress. A high rate of perforation occurred mostly in revision arthroplasty. Breaching the integrity of the gloves, especially by high mechanical loads, could lead to an increased rate of infection.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...