Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
PLoS One ; 19(6): e0304423, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38889124

RESUMEN

INTRODUCTION: Ischemic heart disease is a leading cause of death worldwide, and its importance is increasing with the aging population. The aim of this study was to evaluate the accuracy of SurvTrace, a survival analysis model using the Transformer-a state-of-the-art deep learning method-for predicting recurrent cardiovascular events and stratifying high-risk patients. The model's performance was compared to that of a conventional scoring system utilizing real-world data from cardiovascular patients. METHODS: This study consecutively enrolled patients who underwent percutaneous coronary intervention (PCI) at the Department of Cardiovascular Medicine, University of Tokyo Hospital, between 2005 and 2019. Each patient's initial PCI at our hospital was designated as the index procedure, and a composite of major adverse cardiovascular events (MACE) was monitored for up to two years post-index event. Data regarding patient background, clinical presentation, medical history, medications, and perioperative complications were collected to predict MACE. The performance of two models-a conventional scoring system proposed by Wilson et al. and the Transformer-based model SurvTrace-was evaluated using Harrell's c-index, Kaplan-Meier curves, and log-rank tests. RESULTS: A total of 3938 cases were included in the study, with 394 used as the test dataset and the remaining 3544 used for model training. SurvTrace exhibited a mean c-index of 0.72 (95% confidence intervals (CI): 0.69-0.76), which indicated higher prognostic accuracy compared with the conventional scoring system's 0.64 (95% CI: 0.64-0.64). Moreover, SurvTrace demonstrated superior risk stratification ability, effectively distinguishing between the high-risk group and other risk categories in terms of event occurrence. In contrast, the conventional system only showed a significant difference between the low-risk and high-risk groups. CONCLUSION: This study based on real-world cardiovascular patient data underscores the potential of the Transformer-based survival analysis model, SurvTrace, for predicting recurrent cardiovascular events and stratifying high-risk patients.


Asunto(s)
Isquemia Miocárdica , Humanos , Masculino , Femenino , Anciano , Isquemia Miocárdica/mortalidad , Persona de Mediana Edad , Análisis de Supervivencia , Medición de Riesgo/métodos , Intervención Coronaria Percutánea , Factores de Riesgo , Recurrencia , Aprendizaje Profundo , Estimación de Kaplan-Meier , Pronóstico
2.
Res Pract Thromb Haemost ; 8(4): 102431, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38840664

RESUMEN

Background: Various cardiovascular diseases cause acquired von Willebrand syndrome (AVWS), which is characterized by a decrease in high-molecular-weight (large) von Willebrand factor (VWF) multimers. Mitral regurgitation (MR) has been reported as a cause of AVWS. However, much remains unclear about AVWS associated with MR. Objectives: To evaluate VWF multimers in MR patients and examine their impact on clinical characteristics. Methods: Moderate or severe MR patients (n = 84) were enrolled. VWF parameters such as the VWF large multimer index (VWF-LMI), a quantitative value that represents the amount of VWF large multimers, and clinical data were prospectively analyzed. Results: At baseline, the mean hemoglobin level was 12.9 ± 1.9 g/dL and 58 patients (69.0%) showed loss of VWF large multimers defined as VWF-LMI < 80%. VWF-LMI in patients with degenerative MR was lower than in those with functional MR. VWF-LMI appeared to be restored the day after mitral valve intervention, and the improvement was maintained 1 month after the intervention. Seven patients (8.3%) had a history of bleeding, 6 (7.1%) of whom had gastrointestinal bleeding. Gastrointestinal endoscopy was performed in 23 patients (27.4%) to investigate overt gastrointestinal bleeding, anemia, etc. Angiodysplasia was detected in 2 of the 23 patients (8.7%). Conclusion: Moderate or severe MR is frequently associated with loss of VWF large multimers, and degenerative MR may cause more severe loss compared with functional MR. Mitral valve intervention corrects the loss of VWF large multimers. Gastrointestinal bleeding may be relatively less frequent and hemoglobin level remains stable in MR patients.

3.
J Clin Biochem Nutr ; 74(3): 221-229, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38799134

RESUMEN

Growth hormone (GH) exerts multiple effects on different organs directly or via its main mediator, insulin-like growth factor1 (IGF1). In this study, we focused on the novel relationship between GH action and the antiaging hormone α-klotho. Immunofluorescent staining of α-klotho was observed in the renal distal tubules and pituitary glands of somatostatin- and GH-positive cells in wild-type (WT) mice. Treatment of 4-week-old WT mice with GH increased IGF1 mRNA expression in the pituitary gland, liver, heart, kidney, and bone but increased α-klotho mRNA expression only in the pituitary gland, kidney, and bone. Increased α-klotho protein levels were observed in the kidney but not in the pituitary gland. No induction of α-klotho RNA expression by GH was observed in juvenile mice with kidney disease, indicating GH resistance. Furthermore, GH and α-klotho supplementation in HEK293 cells transfected with GHR increased Janus kinase 2 mRNA (a GH downstream signal) expression compared to supplementation with GH alone. In conclusion, we suggest that 1) the kidney is the main source of secreted α-klotho, which is detected in blood by the downstream action of GH, 2) α-klotho induction by GH is resistant in kidney disease, and 3) α-klotho might be an enhanced regulator of GH signaling.

4.
Res Pract Thromb Haemost ; 8(1): 102284, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38268521

RESUMEN

Background: Severe aortic stenosis (AS) causes acquired von Willebrand syndrome by the excessive shear stress-dependent cleavage of high molecular weight multimers of von Willebrand factor (VWF). While the current standard diagnostic method is so-called VWF multimer analysis that is western blotting under nonreducing conditions, it remains unclear whether a ratio of VWF Ristocetin co-factor activity (VWF:RCo) to VWF antigen levels (VWF:Ag) of <0.7, which can be measured with an automated coagulation analyzer in clinical laboratories and is used for the diagnosis of hereditary von Willebrand disease. Objectives: To evaluated whether the VWF:RCo/VWF:Ag is useful for the diagnosis of AS-induced acquired von Willebrand syndrome. Methods: VWF:RCo and VWF:Ag were evaluated with the VWF large multimer index as a reference, which represents the percentage of a patient's VWF high molecular weight multimer ratio to that of standard plasma in the VWF multimer analysis. Results: We analyzed 382 patients with AS having transaortic valve maximal pressure gradients of >30 mmHg, 27 patients with peripheral artery disease, and 46 control patients free of cardiovascular disease with osteoarthritis, diabetes, and so on. We assumed a large multimer index of <80% as loss of VWF large multimers since 59.0% of patients with severe AS had the indices of <80%, while no control patients or patients with peripheral artery disease, except for 2 patients, exhibited the indices of <80%. The VWF:RCo/VWF:Ag ratios, measured using an automated blood coagulation analyzer, were correlated with the indices (rs = 0.470, P < .001). When the ratio of <0.7 was used as a cut-off point, the sensitivity and specificity to VWF large multimer indices of <80% were 0.437 and 0.826, respectively. Conclusion: VWF:RCo/VWF:Ag ratios of <0.7 may indicate loss of VWF large multimers with high specificity, but low sensitivity. VWF:RCo/VWF:Ag ratios in patients with AS having a ratio of <0.7 may be useful for monitoring the loss of VWF large multimers during their clinical courses.

5.
Int Heart J ; 65(1): 29-38, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38296576

RESUMEN

Comprehensive management approaches for patients with ischemic heart disease (IHD) are important aids for prognostication and treatment planning. While single-modality deep neural networks (DNNs) have shown promising performance for detecting cardiac abnormalities, the potential benefits of using DNNs for multimodality risk assessment in patients with IHD have not been reported. The purpose of this study was to investigate the effectiveness of multimodality risk assessment in patients with IHD using a DNN that utilizes 12-lead electrocardiograms (ECGs) and chest X-rays (CXRs), with the prediction of major adverse cardiovascular events (MACEs) being of particular concern.DNN models were applied to detection of left ventricular systolic dysfunction (LVSD) on ECGs and identification of cardiomegaly findings on CXRs. A total of 2107 patients who underwent elective percutaneous coronary intervention were categorized into 4 groups according to the models' outputs: Dual-modality high-risk (n = 105), ECG high-risk (n = 181), CXR high-risk (n = 392), and No-risk (n = 1,429).A total of 342 MACEs were observed. The incidence of a MACE was the highest in the Dual-modality high-risk group (P < 0.001). Multivariate Cox hazards analysis for predicting MACE revealed that the Dual-modality high-risk group had a significantly higher risk of MACE than the No-risk group (hazard ratio (HR): 2.370, P < 0.001), the ECG high-risk group (HR: 1.906, P = 0.010), and the CXR high-risk group (HR: 1.624, P = 0.018), after controlling for confounding factors.The results suggest the usefulness of multimodality risk assessment using DNN models applied to 12-lead ECG and CXR data from patients with IHD.


Asunto(s)
Aprendizaje Profundo , Isquemia Miocárdica , Humanos , Rayos X , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/epidemiología , Medición de Riesgo , Electrocardiografía
6.
Oxf Med Case Reports ; 2023(11): omad125, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38033403

RESUMEN

The number of cancer patients with severe aortic stenosis and atrial fibrillation (AF) is increasing in the aging population. Transcatheter aortic valve replacement (TAVR) is an established treatment option for severe aortic stenosis with high surgical risk, including individuals with cancer. Antithrombotic therapy should be considered for post-TAVR or AF patients. However, antithrombotic management in cancer patients remains challenging due to the increased risk of both thromboembolism and bleeding. We present a case of clinical valve thrombosis and arterial embolism after transcatheter aortic valve replacement in an elderly patient with a history of metastatic pancreatic cancer and permanent atrial fibrillation under treatment of single antiplatelet therapy. Warfarin treatment after successful surgical thrombectomy to the occluded arteries improved clinical valve thrombosis, although the long-term outcome remains unclear. This case demonstrates that novel management algorithms for thromboembolism and bleeding in elderly cancer patients with AF and valvular heart disease are urgently needed.

7.
J Med Invest ; 70(1.2): 260-270, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37164731

RESUMEN

BACKGROUND: Inorganic phosphate (Pi) binders are the only pharmacologic treatment approved for hyperphosphatemia. However, Pi binders induce the expression of intestinal Pi transporters and have limited effects on the inhibition of Pi transport. EOS789, a novel pan-Pi transporter inhibitor, reportedly has potent efficacy in treating hyperphosphatemia. We investigated the properties of EOS789 with comparison to a conventional Pi binder. METHODS: Protein and mRNA expression levels of Pi transporters were measured in intestinal and kidney tissues from male Wistar rats fed diets supplemented with EOS789 or lanthanum carbonate (LC). 32Pi permeability was measured in intestinal tissues from normal rats using a chamber. RESULTS: Increased protein levels of NaPi-2b, an intestinal Pi transporter, and luminal Pi removal were observed in rats treated with LC but not in rats treated with EOS789. EOS789 but not LC suppressed intestinal protein levels of the Pi transporter Pit-1 and sodium/hydrogen exchanger isoform 3. 32Pi flux experiments using small intestine tissues from rats demonstrated that EOS789 may affect transcellular Pi transport in addition to paracellular Pi transport. CONCLUSION: EOS789 has differing regulatory effects on Pi metabolism compared to LC. The properties of EOS789 may compensate for the limitations of LC therapy. The combined or selective use of EOS789 and conventional Pi binders may allow tighter control of hyperphosphatemia. J. Med. Invest. 70 : 260-270, February, 2023.


Asunto(s)
Hiperfosfatemia , Proteínas de Transporte de Fosfato , Ratas , Masculino , Animales , Proteínas de Transporte de Fosfato/metabolismo , Ratas Wistar , Hiperfosfatemia/tratamiento farmacológico , Absorción Intestinal , Fosfatos/metabolismo
8.
J Med Invest ; 69(3.4): 173-179, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36244766

RESUMEN

Phosphate (Pi)-containing food additives are used in several forms. Polyphosphate (PPi) salt has more harmful effects than monophosphate (MPi) salt on bone physiology and renal function. This study aimed to analyze the levels of parathyroid hormone PTH and fibroblast growth factor 23 (FGF23) and the expression of renal / intestinal Pi transport-related molecules in mice fed with an MPi or PPi diet. There were no significant differences in plasma Pi concentration and fecal Pi excretion levels between mice fed with the high-MPi and PPi diet. However, more severe tubular dilatation, interstitial fibrosis, and calcification were observed in the kidneys of mice fed with the high PPi diet versus the MPi diet. Furthermore, there was a significant increase in serum FGF23 levels and a decrease in renal phosphate transporter protein expression in mice fed with the PPi diet versus the MPi diet. Furthermore, the high MPi diet was associated with significantly suppressed expression and activity of intestinal alkaline phosphatase protein. In summary, PPi has a more severe effect on renal damage than MPi, as well as induces more FGF23 secretion. Excess FGF23 may be more involved in inflammation, fibrosis, and calcification in the kidney. J. Med. Invest. 69 : 173-179, August, 2022.


Asunto(s)
Fosfatasa Alcalina , Polifosfatos , Animales , Ratones , Fosfatasa Alcalina/metabolismo , Dieta , Factores de Crecimiento de Fibroblastos , Fibrosis , Aditivos Alimentarios/metabolismo , Riñón/metabolismo , Hormona Paratiroidea/metabolismo , Proteínas de Transporte de Fosfato/metabolismo , Fosfatos/metabolismo , Fosfatos/farmacología , Polifosfatos/metabolismo
9.
PLoS One ; 17(10): e0276928, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36301966

RESUMEN

Coronary angiography (CAG) is still considered the reference standard for coronary artery assessment, especially in the treatment of acute coronary syndrome (ACS). Although aging causes changes in coronary arteries, the age-related imaging features on CAG and their prognostic relevance have not been fully characterized. We hypothesized that a deep neural network (DNN) model could be trained to estimate vascular age only using CAG and that this age prediction from CAG could show significant associations with clinical outcomes of ACS. A DNN was trained to estimate vascular age using ten separate frames from each of 5,923 CAG videos from 572 patients. It was then tested on 1,437 CAG videos from 144 patients. Subsequently, 298 ACS patients who underwent percutaneous coronary intervention (PCI) were analysed to assess whether predicted age by DNN was associated with clinical outcomes. Age predicted as a continuous variable showed mean absolute error of 4 years with R squared of 0.72 (r = 0.856). Among the ACS patients stratified by predicted age from CAG images before PCI, major adverse cardiovascular events (MACE) were more frequently observed in the older vascular age group than in the younger vascular age group (p = 0.017). Furthermore, after controlling for actual age, gender, peak creatine kinase, and history of heart failure, the older vascular age group independently suffered from more MACE (hazard ratio 2.14, 95% CI 1.07 to 4.29, p = 0.032). The vascular age estimated based on CAG imaging by DNN showed high predictive value. The age predicted from CAG images by DNN could have significant associations with clinical outcomes in patients with ACS.


Asunto(s)
Síndrome Coronario Agudo , Intervención Coronaria Percutánea , Humanos , Preescolar , Intervención Coronaria Percutánea/efectos adversos , Angiografía Coronaria/efectos adversos , Síndrome Coronario Agudo/tratamiento farmacológico , Pronóstico , Redes Neurales de la Computación , Factores de Riesgo
11.
Front Cardiovasc Med ; 9: 1001833, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36684556

RESUMEN

Background: Fractional flow reserve (FFR) is the current gold standard for identifying myocardial ischemia in individuals with coronary artery stenosis. However, FFR is not penetrated as much worldwide due to time consumption, costs associated with adenosine, FFR-related discomfort, and complications. Resting physiological indexes may be widely accepted alternatives to FFR, while the discrepancies with FFR were found in up to 20% of lesions. The saline-induced Pd/Pa ratio (SPR) is a new simplified option for evaluating coronary stenosis. However, the clinical implication of SPR remains unclear. Objectives: In the present study, we aimed to compare the accuracies of SPR and resting full-cycle ratio (RFR) and to investigate the incremental value of SPR in clinical practice. Methods: In this multicenter prospective study, 112 coronary lesions (105 patients) were evaluated by SPR, RFR, and FFR. Results: The overall median age was 71 years, and 84.8% were men. SPR was correlated more strongly with FFR than with RFR (r = 0.874 vs. 0.713, respectively; p < 0.001). Using FFR < 0.80 as the reference standard variable, the area under the receiver-operating characteristic (ROC) curve for SPR was superior to that of RFR (0.932 vs. 0.840, respectively; p = 0.009). Conclusion: Saline-induced Pd/Pa ratio predicted FFR more accurately than RFR. SPR could be an alternative method for evaluating coronary artery stenosis and further investigation including elucidation of the mechanism of SPR is needed (225 words).

12.
JACC Cardiovasc Interv ; 14(11): 1218-1228, 2021 06 14.
Artículo en Inglés | MEDLINE | ID: mdl-34112458

RESUMEN

OBJECTIVES: The aim of this study was to define predictors of prosthesis-patient mismatch (PPM) and its impact on mortality after transcatheter aortic valve replacement (TAVR) with self-expandable valves (SEVs) in patients with small annuli. BACKGROUND: TAVR seems to reduce the risk for PPM compared with surgical aortic valve replacement, especially in patients with small aortic annuli. Nevertheless, predictors and impact of PPM in this population have not been clarified yet. METHODS: Predictors of PPM and all-cause mortality were investigated using multivariable logistic regression analysis from the cohort of the TAVI-SMALL (International Multicenter Registry to Evaluate the Performance of Self-Expandable Valves in Small Aortic Annuli) registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 on computed tomography) treated with transcatheter SEVs: 445 patients with (n = 129) and without (n = 316) PPM were enrolled. RESULTS: Intra-annular valves conferred increased risk for PPM (odds ratio [OR]: 2.36; 95% confidence interval [CI]: 1.16 to 4.81), while post-dilation (OR: 0.46; 95% CI: 0.25-0.84) and valve oversizing (OR: 0.53; 95% CI: 0.28-1.00) seemed to protect against PPM occurrence. At a median follow-up of 354 days, patients with severe PPM, but not those with moderate PPM, had a higher all-cause mortality rate compared with those without PPM (log-rank p = 0.008). Multivariable Cox regression confirmed severe PPM as an independent predictor of all-cause mortality (hazard ratio: 4.27; 95% CI: 1.34 to 13.6). CONCLUSIONS: Among patients with aortic stenosis and small aortic annuli undergoing transcatheter SEV implantation, use of intra-annular valves yielded higher risk for PPM; conversely, post-dilation and valve oversizing protected against PPM occurrence. Severe PPM was independently associated with all-cause mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
13.
Catheter Cardiovasc Interv ; 98(4): 756-764, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33991385

RESUMEN

OBJECTIVES: To evaluate outcome and its predictors of bioprosthetic valve fracture (BVF) in patients undergoing valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). BACKGROUND: BVF is feasible and reduces transvalvular gradients in VIV-TAVR-procedures, but follow-up-data and information on factors influencing the outcome are missing. METHODS: The 81 cases of BVF-VIV-TAVR were collected from 14 international centers. RESULTS: Predominantly transcatheter heart valve (THV) was implanted first, followed by BVF. VARC-2 defined device success was 93%, most failures were attributed to residual high gradients. Mean gradients decreased from 37 ± 13 mmHg to 10.8 ± 5.9 mmHg (p < 0.001). BVF reduced the gradient by 16 mmHg. During follow-up (FU, 281 ± 164 days) mean gradient remained stable (10.8 ± 5.9 mmHg at discharge, 12.4 ± 6.3 mmHg at FU, p = ns). In-hospital major adverse events occurred in 3.7%. Event-free survival at 276 ± 237.6 days was 95.4%. The linear mixed model identified balloon-expandable valves (BEV), Mitroflow surgical valve, stenotic surgical bioprostheses and balloon only 1 mm larger than the true internal diameter of the surgical valve as predictors for higher gradients. CONCLUSIONS: BVF is safe and can significantly reduce gradients, which remain stable at FU. BEV, Mitroflow surgical valve, stenotic bioprostheses and balloon larger than the true internal diameter of the surgical valve of only 1 mm are predictors for higher final gradients.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios de Seguimiento , Hemodinámica , Humanos , Diseño de Prótesis , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
14.
EuroIntervention ; 17(4): e343-e352, 2021 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-33956637

RESUMEN

BACKGROUND: Tricuspid regurgitation (TR) has a poor prognosis and limited treatment options and is frequently accompanied by right ventricular (RV) dysfunction. Transcatheter tricuspid valve interventions (TTVI) to reduce TR have been shown to be safe and feasible with encouraging early results. Patient selection for TTVI remains challenging, with the role of right ventricular (RV) function being unknown. AIMS: The aims of this study were 1) to investigate survival in a TTVI-treated patient population and a conservatively treated TR population, and 2) to evaluate the outcome of TTVI as compared to conservative treatment stratified according to the degree of RV function. METHODS: We studied 684 patients from the multicentre TriValve cohort (TTVI cohort) and compared them to 914 conservatively treated patients from two tertiary care centres. Propensity matching identified 213 pairs of patients with severe TR. As we observed a non-linear relationship of RV function and TTVI outcome, we stratified patients according to tricuspid annular plane systolic excursion (TAPSE) to preserved (TAPSE >17 mm), mid-range (TAPSE 13-17 mm) and reduced (TAPSE <13 mm) RV function. The primary outcome was one-year all-cause mortality. RESULTS: TTVI was associated with a survival benefit in patients with severe TR when compared to matched controls (one-year mortality rate: 13.1% vs 25.8%; p=0.031). Of the three RV subgroups, only in patients with mid-range RV function was TTVI associated with an improved survival (p log-rank 0.004). In these patients, procedural success was associated with a reduced hazard ratio for all-cause mortality (HR 0.22; 95% CI: 0.09, 0.57). CONCLUSIONS: TTVI is associated with reduced mortality compared to conservative therapy and might exert its highest treatment effect in patients with mid-range reduced RV function.


Asunto(s)
Insuficiencia de la Válvula Tricúspide , Disfunción Ventricular Derecha , Humanos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/terapia , Función Ventricular Derecha
15.
Catheter Cardiovasc Interv ; 98(6): E862-E869, 2021 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-33961729

RESUMEN

OBJECTIVES: To evaluate the use and outcomes of percutaneous mechanical circulatory support (pMCS) utilized during transcatheter aortic valve implantation (TAVI) from high-volume centers. METHODS AND RESULTS: Our international multicenter registry including 13 high-volume TAVI centers with 87 patients (76.5 ± 11.8 years, 63.2% men) who underwent TAVI for severe aortic stenosis and required pMCS (75.9% VA-ECMO, 19.5% Impella CP, 4.6% TandemHeart) during the procedure (prior to TAVI 39.1%, emergent rescue 50.6%, following TAVI 10.3%). The procedures were considered high-risk, with 50.6% having severe left ventricular dysfunction, 24.1% biventricular dysfunction, and 32.2% severe pulmonary hypertension. In-hospital and 1-year mortality were 27.5% and 49.4%, respectively. Patients with prophylactic hemodynamic support had lower periprocedural mortality compared to patients with rescue insertion of pMCS (log rank = 0.013) and patients who did not undergo cardiopulmonary resuscitation during the TAVI procedure had better short and long term survival (log rank <0.001 and 0.015, respectively). CONCLUSIONS: Given the overall survival rate and low frequency of pMCS-related complications, our study results support the use of pMCS prophylactically or during the course of TAVI (bailout) in order to improve clinical outcomes in high-risk procedures or in case of acute life-threatening hemodynamic collapse.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Sistema de Registros , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
16.
Circ Cardiovasc Interv ; 14(2): e009685, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33541097

RESUMEN

BACKGROUND: Scarce data exist on patients with right ventricular dysfunction (RVD) or pulmonary hypertension (PH) undergoing transcatheter tricuspid valve intervention. This study aimed to determine the early and midterm outcomes and the factors associated with mortality in this group of patients. METHODS: This subanalysis of the multicenter TriValve (Transcatheter Tricuspid Valve Therapies) registry included 300 patients with severe tricuspid regurgitation with RVD (n=244), PH (n=127), or both (n=71) undergoing transcatheter tricuspid valve intervention. RVD was defined as a tricuspid annular plane systolic excursion <17 mm, and PH as an estimated pulmonary artery systolic pressure ≥50 mm Hg. RESULTS: Mean age of the patients was 77±9 years (54% women). Procedural success was 80.7%, and 9 patients (3%) died during the hospitalization. At a median follow-up of 6 (interquartile range, 2-12) months, 54 patients (18%) died, and the independent associated factors were higher gamma-glutamyl transferase values at baseline (hazard ratio, 1.02 for each increase of 10 u/L [95% CI, 1.002-1.04]), poorer renal function defined as an estimated glomerular filtration rate <45 mL/min (hazard ratio, 2.3 [95% CI, 1.22-4.33]), and the lack of procedural success (hazard ratio, 2.11 [95% CI, 1.17-3.81]). The grade of RVD and the amount of PH at baseline were not found to be predictors of mortality. Most patients alive at follow-up improved their functional class (New York Heart Association I-II in 66% versus 7% at baseline, P<0.001). CONCLUSIONS: In patients with severe tricuspid regurgitation and RVD/PH, transcatheter tricuspid valve intervention was associated with high procedural success and a relatively low in-hospital mortality, along with significant improvements in functional status. However, about 1 out of 5 patients died after a median follow-up of 6 months, with hepatic congestion, renal dysfunction, and the lack of procedural success determining an increased risk. These results may improve the clinical evaluation of transcatheter tricuspid valve intervention candidates and would suggest a closer follow-up in those at increased risk. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03416166.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Hipertensión Pulmonar , Insuficiencia de la Válvula Tricúspide , Disfunción Ventricular Derecha , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Femenino , Humanos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/etiología , Hipertensión Pulmonar/terapia , Masculino , New York , Sistema de Registros , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/etiología , Disfunción Ventricular Derecha/terapia
17.
Can J Cardiol ; 37(7): 1094-1102, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33617978

RESUMEN

BACKGROUND: Scarce data exist on patients with previous left valve surgery (PLVS) undergoing transcatheter tricuspid valve intervention (TTVI). This study sought to investigate the procedural and early outcomes in patients with PLVS undergoing TTVI. METHODS: This was a subanalysis of the multicenter TriValve registry including 462 patients, 82 (18%) with PLVS. Data were analyzed according to the presence of PLVS in the overall cohort and in a propensity score-matched population including 51 and 115 patients with and without PLVS, respectively. RESULTS: Patients with PLVS were younger (72 ± 10 vs 78 ± 9 years; p < 0.01) and more frequently female (67.1% vs 53.2%; P = 0.02). Similar rates of procedural success (PLVS 80.5%; no-PLVS 82.1%; P = 0.73), and 30-day mortality (PLVS 2.4%, no-PLVS 3.4%; P = 0.99) were observed. After matching, there were no significant differences in both all-cause rehospitalisation (PLVS 21.1%, no-PLVS 26.5%; P = 0.60) and all-cause mortality (PLVS 9.8%, no-PLVS 6.7%; P = 0.58). At last follow-up (median 6 [interquartile range 1-12] months after the procedure), most patients (81.8%) in the PLVS group were in NYHA functional class I-II (P = 0.12 vs no-PLVS group), and TR grade was ≤ 2 in 82.6% of patients (P = 0.096 vs no-PVLS group). A poorer right ventricular function and previous heart failure hospitalization determined increased risks of procedural failure and poorer outcomes at follow-up, respectively. CONCLUSIONS: In patients with PLVS, TTVI was associated with high rates of procedural success and low early mortality. However, about one-third of patients required rehospitalisation or died at midterm follow-up. These results would support TTVI as a reasonable alternative to redo surgery in patients with PLVS and suggest the importance of earlier treatment to improve clinical outcomes.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide/cirugía , Disfunción Ventricular Derecha , Anciano , Cateterismo Cardíaco/métodos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/estadística & datos numéricos , Humanos , Masculino , Evaluación de Resultado en la Atención de Salud , Readmisión del Paciente/estadística & datos numéricos , Sistema de Registros/estadística & datos numéricos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Análisis de Supervivencia , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/mortalidad , Insuficiencia de la Válvula Tricúspide/cirugía , Disfunción Ventricular Derecha/diagnóstico , Disfunción Ventricular Derecha/etiología
19.
Catheter Cardiovasc Interv ; 97(5): E724-E726, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-32154645

RESUMEN

Transcatheter tricuspid valve intervention (TTVI) is an emerging treatment for patients with symptomatic severe tricuspid regurgitation (TR). Currently, the issues that arise during TTVI are unclear. Here, a 78-year-old woman with severe TR underwent transcatheter tricuspid valve annuloplasty using a Cardioband (Edwards Lifesciences, Irvine, CA). We attempted to cinch the Dacron band after anchoring; however, it was impossible to connect the distal tip of the size adjustment tool and the Dacron band because the cinching wire was tangled around the Dacron band. We resolved this issue without surgical intervention, and eventually cinched the annulus. Final echocardiography revealed dramatic TR reduction. To our knowledge, no study has reported a tangled wire in a Dacron band during Cardioband use. Clinicians should be aware of the risks accompanying this concern in case where it is impossible to connect the distal tip of the size adjustment tool and the Dacron band during cinching.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Anciano , Cateterismo Cardíaco/efectos adversos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Tereftalatos Polietilenos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía
20.
J Cardiovasc Med (Hagerstown) ; 22(3): 212-221, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-32890234

RESUMEN

AIM: To describe six cases using the bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction technique to prevent coronary artery obstruction during transcatheter aortic valve-in-valve procedures. METHODS: All patients presented degeneration of a bovine pericardium bioprosthesis [four Trifecta (19, 21, 23, and 25 mm); two Mitroflow (25 and 27 mm)] resulting in severe aortic stenosis (n = 5) or severe aortic regurgitation (n = 1). Procedures were performed under fluoroscopic and echocardiography guidance, and the transfemoral access was used to deliver a self-expanding valve. Data are expressed as frequency or median (Q1-Q3). RESULTS: Age, EuroScore II, and Society of Thoracic Surgeons score were 81 years (75-83.2), 2.9% (2.6-10.7), and 2.7% (2.3-3.2), respectively. Median left and right coronary heights were 9.1 mm (6.2-10.3) and 12.4 mm (10-13.5), respectively, with a median virtual transcatheter heart valve-to-coronary distance of 2.9 mm on the left and 4.6 mm on the right side. Isolated left leaflet laceration was planned in four patients, and bileaflet in two. One unsuccessful right leaflet laceration was reported, corresponding to the first patient (success rate 87.5%). All other seven leaflets lacerations were successfully performed, with no intraprocedure complications. No coronary obstruction, in-hospital death, valve complication, cardiovascular event, or pacemaker implantation were reported. All patients are being followed in routine outpatient visits, and no adverse events were registered. CONCLUSION: The high procedural success and low complication rate reported in this initial experience, demonstrates that the bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction technique can be a viable solution to prevent coronary obstruction in selected patients undergoing valve-in-valve procedures. Operator experience, periprocedural imaging and teamwork are essential to enable an accurate and successful procedure.


Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis , Oclusión Coronaria/prevención & control , Enfermedad Iatrogénica/prevención & control , Complicaciones Posoperatorias/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Angiografía Coronaria , Oclusión Coronaria/diagnóstico , Oclusión Coronaria/etiología , Vasos Coronarios/diagnóstico por imagen , Femenino , Fluoroscopía , Estudios de Seguimiento , Humanos , Masculino , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA