Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
J Arrhythm ; 40(3): 605-613, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38939791

RESUMEN

Background: The Mt FUJI study was a multicenter, prospective, randomized, single-blind, controlled trial comparing delivery catheter-based and stylet-based right ventricular (RV) lead placement at the RV septum. This study extended the follow-up duration to 1 year after implantation. Methods: Seventy patients with pacemaker indications for atrioventricular block were randomly assigned to the delivery catheter and stylet groups. We compared the mid-term efficacy and safety between the two groups at 1 year after implantation. The primary outcome was the change in the left ventricular ejection fraction (LVEF), and the secondary outcomes were changes in brain natriuretic peptide (BNP) levels, lead parameters, paced QRS duration, and the incidence of adverse events. Results: At the 1-year follow-up, no significant differences were observed in the changes in the LVEF (+1.0% ± 8.6% vs. +3.1% ± 8.1%, p = .332), BNP levels (+8.0 [-11.1, 26.5] pg/mL vs. -8.7 [-15.3, 13.2] pg/mL, p = .193), or lead performance between the delivery catheter and stylet groups. The QRS duration was significantly shorter in the delivery catheter group than in the stylet group (128 ± 23 ms vs. 146 ± 17 ms, p < .001). All-cause death, hospitalization for heart failure, new development of atrial fibrillation, and pacing-induced cardiomyopathy occurred in seven patients in the delivery catheter group and five in the stylet group. Conclusion: The delivery catheter system was similarly useful and safe compared to the stylet system in the mid-term follow-up from the Mt FUJI trial. Further long-term evaluations are warranted.

2.
J Cardiovasc Electrophysiol ; 35(4): 802-810, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38409896

RESUMEN

INTRODUCTION: The Mt. FUJI multicenter trial demonstrated that a delivery catheter system had a higher rate of successful right ventricular (RV) lead deployment on the RV septum (RVS) than a conventional stylet system. In this subanalysis of the Mt. FUJI trial, we assessed the differences in electrocardiogram (ECG) parameters during RV pacing between a delivery catheter system and a stylet system and their associations with the lead tip positions. METHODS: Among 70 patients enrolled in the Mt FUJI trial, ECG parameters, RV lead tip positions, and lead depth inside the septum assessed by computed tomography were compared between the catheter group (n = 36) and stylet group (n = 34). RESULTS: The paced QRS duration (QRS-d), corrected paced QT (QTc), and JT interval (JTc) were significantly shorter in the catheter group than in the stylet group (QRS-d: 130 ± 19 vs. 142 ± 15 ms, p = .004; QTc: 476 ± 25 vs. 514 ± 20 ms, p < .001; JTc: 347 ± 24 vs. 372 ± 17 ms, p < .001). This superiority of the catheter group was maintained in a subgroup analysis of patients with an RV lead tip position at the septum. The lead depth inside the septum was greater in the catheter group than in the stylet group, and there was a significant negative correlation between the paced QRS-d and the lead depth. CONCLUSION: Using a delivery catheter system carries more physiological depolarization and repolarization during RVS pacing and deeper screw penetration in the septum in comparison to conventional stylet system. The lead depth could have a more impact on the ECG parameters rather than the type of pacing lead.


Asunto(s)
Estimulación Cardíaca Artificial , Tabique Interventricular , Humanos , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Catéteres , Electrocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Tabique Interventricular/diagnóstico por imagen
3.
Quant Imaging Med Surg ; 13(10): 6840-6853, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37869287

RESUMEN

Background: Left bundle branch area pacing (LBBAP) has emerged as a novel physiological pacing method to reduce left ventricular (LV) dyssynchrony due to ventricular pacing. Only lumen-less pacing leads (LLLs) with fixed helixes could achieve LBBAP previously, but recently, LBBAP has been performed using stylet-driven leads (SDLs). This study aimed to evaluate the LV dyssynchrony between SDLs and LLLs techniques in LBBAP. Methods: We retrospectively evaluated patients who underwent LBBAP with either SDLs or LLLs. We compared both groups' electrocardiogram (ECG) findings and LV dyssynchrony parameters derived from myocardial perfusion scintigraphy. LV dyssynchrony parameters consisted of phase analysis and regional wall motion analysis. We evaluated bandwidth, phase standard deviation (PSD), and entropy in the phase analysis. The time to the end-systolic frame (TES) was calculated in regional wall motion analysis using single-photon emission computed tomography (SPECT). We also evaluated the maximum differences between segmental TES (MDTES), the standard deviation of TES (SDTES), and the difference in the TES between the lateral wall and septum (DTES-LS). Results: In total, 97 patients were enrolled. The success rate of LBBAP did not differ between the groups [SDLs: 47/48 patients (98%) vs. LLLs: 47/51 patients (92%), P=0.36]. The paced QRS duration and the stimulus to the peak LV activation time (stim-LVAT) also did not differ between SDL and LLL groups (122±10 vs. 119±12 ms, P=0.206; 69±12 vs. 66±13 ms, P=0.31, respectively). There were no differences in bandwidth, PSD, and entropy between SDL and LLL groups (73°±37° vs. 86°±47°, P=0.18; 19°±8.5° vs. 21°±9.7°, P=0.19; 0.57±0.08 vs. 0.59±0.08, P=0.17, respectively). The regional wall motion analysis parameters MDTES, SDTES, and DTES-LS also did not differ between SDL and LLL groups (19%±10% vs. 20%±10%, P=0.885; 5.0%±2.5% vs. 5.0%±2.5%, P=0.995; 5.0%±3.7% vs. 4.8%±4.2%, P=0.78, respectively). Conclusions: LBBAP using SDLs was comparable to LV electrical and mechanical synchrony with LLLs.

4.
J Cardiol ; 82(5): 371-377, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37100387

RESUMEN

BACKGROUND: Pacemaker leads were originally implanted into the right atrial appendage (RAA) and right ventricular apex, but septal pacing, which is more physiological, is becoming increasingly popular. The usefulness of atrial lead implantation in the RAA or atrial septum is inconclusive, and whether or not atrial septum implantation is accurate has not yet been verified. METHODS: Patients who underwent pacemaker implantation between January 2016 and December 2020 were included. The success rate of atrial septal implantation was validated using thoracic computed tomography performed for any reason postoperatively. We examined factors related to the successful implantation of the atrial lead in the atrial septum. RESULTS: Forty-eight people were included in this study. Lead placement was performed with a delivery catheter system (SelectSecure MRI SureScan; Medtronic Japan Co., Ltd., Tokyo, Japan) in 29 cases and a conventional stylet in 19 cases. The mean age was 74 ±â€¯12 years old, and 28 (58%) were male. Successful atrial septal implantation was performed in 26 patients (54%), with only 4 (21%) successful implantations in the stylet group. There were no significant differences in the age, gender, body mass index (BMI), pacing P wave axis, duration, or amplitude between the atrial septal implantation group and non-septal groups. The only significant difference was for delivery catheter use [22 (85%) vs. 7 (32%), p < 0.001]. In multivariate logistic analysis, the use of a delivery catheter was independently associated with successful septal implantation [odds ratio (OR): 16.9, 95% confidence interval 3.0-90.9] after adjusting for the age, gender, and BMI. CONCLUSION: The success rate of atrial septal implantation was very low at 54%, and only the use of a delivery catheter was associated with successful septal implantation. However, even with a delivery catheter, the success rate was 76%, so further investigations are warranted.


Asunto(s)
Fibrilación Atrial , Tabique Interatrial , Defectos del Tabique Interatrial , Marcapaso Artificial , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Estimulación Cardíaca Artificial
5.
Europace ; 25(4): 1451-1457, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36794652

RESUMEN

AIMS: Although the delivery catheter system for pacemaker-lead implantation is a new alternative to the stylet system, no randomized controlled trial has addressed the difference in right ventricular (RV) lead placement accuracy to the septum between the stylet and the delivery catheter systems. This multicentre prospective randomized controlled trial aimed to prove the efficacy of the delivery catheter system for accurate delivery of RV lead to the septum. METHODS AND RESULTS: In this trial, 70 patients (mean age 78 ± 11 years; 30 men) with pacemaker indications of atrioventricular block were randomized to the delivery catheter or the stylet groups. Right ventricular lead tip positions were assessed using cardiac computed tomography within 4 weeks of pacemaker implantation. Lead tip positions were classified into RV septum, anterior/posterior edge of the RV septal wall, and RV free wall. The primary endpoint was the success rate of RV lead tip placement to the RV septum. RESULTS: Right ventricular leads were implanted as per allocation in all patients. The delivery catheter group had higher success rate of RV lead deployment to the septum (78 vs. 50%; P = 0.024) and narrower paced QRS width (130 ± 19 vs. 142 ± 15 ms P = 0.004) than those in the stylet group. However, there was no significant difference in procedure time [91 (IQR 68-119) vs. 85 (59-118) min; P = 0.488] or the incidence of RV lead dislodgment (0 vs. 3%; P = 0.486). CONCLUSION: The delivery catheter system can achieve a higher success rate of RV lead placement to the RV septum and narrower paced QRS width than the stylet system. TRIAL REGISTRATION NUMBER: jRCTs042200014 (https://jrct.niph.go.jp/en-latest-detail/jRCTs042200014).


Asunto(s)
Estimulación Cardíaca Artificial , Tabique Interventricular , Masculino , Humanos , Anciano , Anciano de 80 o más Años , Estudios Prospectivos , Estimulación Cardíaca Artificial/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Tabique Interventricular/diagnóstico por imagen , Catéteres , Electrocardiografía/métodos
6.
Ann Noninvasive Electrocardiol ; 27(6): e13000, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35972827

RESUMEN

INTRODUCTION: Conventional Doppler measurements have limitations in predicting left ventricular diastolic dysfunction (LVDD) in patients with mitral regurgitation (MR). Recently, electrocardiographic P-wave peak time (PWPT) has been proposed as a parameter of detecting LVDD. This study aimed to evaluate the association between PWPT and left ventricular end-diastolic pressure (LVEDP) in patients with MR. METHODS: We performed echocardiography and cardiac catheterization in 82 patients with moderate or severe MR. We classified patients into two groups: low LVEDP group (L-LVEDP) (LVEDP <16 mmHg, n = 40) and high LVEDP group (H-LVEDP) (LVEDP ≥16 mmHg, n = 42). We evaluated LVDD and PWPT based on echocardiographic and electrocardiographic findings in both groups. RESULTS: The PWPT in lead II (PWPTII ) was significantly longer in patients in the H-LVEDP group than in those in the L-LVEDP group (67 vs. 47 ms, p < .001). Using correlation analysis, LVEDP was positively correlated with PWPTII (r = .577, p < .001). Using multivariate analysis, PWPTII was found to be an independent predictor of increased LVEDP (95% CI: 0.1030-0.110; p < .001). Using receiver operating characteristic (ROC) curve analysis, the optimal cutoff value of PWPTII for predicting elevated LVEDP was 58.9 ms, with a sensitivity of 80.0% and a specificity of 73.8% (area under curve: 0.809, 95% CI: 0.713-0.905). CONCLUSION: To the best of our knowledge, this is the first study to assess the effect of a significant valvular disease on PWPT in lead II. These findings suggest that prolonged PWPTII may be an independent predictor of increased LVEDP in patients with moderate or severe MR.


Asunto(s)
Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Electrocardiografía , Ecocardiografía , Cateterismo Cardíaco , Análisis Multivariante
7.
J Cardiovasc Electrophysiol ; 33(8): 1826-1836, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35748386

RESUMEN

INTRODUCTION: Left bundle branch area pacing (LBBAP) has recently been reported to be a new, clinically feasible and safe physiological pacing strategy. The present study aims to investigate the usefulness of LBBAP in reducing mechanical dyssynchrony compared with right ventricular septal pacing (RVSP). METHODS AND RESULTS: A total of 39 LBBAP patients, 42 RVSP patients, and 93 healthy control participants were retrospectively evaluated. We compared phase analysis- (bandwidth, phase standard deviation [PSD], entropy) and regional wall motion analysis parameters. Wall motion analysis parameters included the time to the end-systolic frame (TES) assessed using single-photon emission computed tomography analysis. The maximum differences between segmental TES (MDTES), the standard deviation of TES (SDTES), and the TES difference between the lateral and septal segments (DTES-LS) were obtained. All phase analysis parameters were significantly smaller in the LBBAP group than in the RVSP group (bandwidth: LBBAP, 74 ± 31° vs. RVSP, 102 ± 59°, p = .009; PSD: LBBAP, 19 ± 6.7° vs. RVSP, 26 ± 15°, p = .007; entropy: LBBAP, 0.57 ± 0.07 vs. RVSP, 0.62 ± 0.11 p = .009). The regional wall motion analysis parameters were also smaller in the LBBAP group than in the RVSP group (MDTES:LBBAP, 17 ± 7.1% vs. RVSP, 25 ± 14%, p = .004; SDTES:LBBAP, 4.5 ± 1.7% vs. RVSP, 6.0 ± 3.5%, p = .015; DTES-LS: LBBAP, 4.1 ± 3.4% vs. RVSP, 7.1 ± 5.4%, p = .004). All phase analysis and wall motion analysis parameters were same in the LBBAP and control groups. CONCLUSION: LBBAP may reduce mechanical dyssynchrony and achieve greater physiological ventricular activation than RVSP.


Asunto(s)
Fascículo Atrioventricular , Marcapaso Artificial , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Humanos , Imagen de Perfusión , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
8.
Cardiovasc Revasc Med ; 40: 123-131, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35101372

RESUMEN

BACKGROUND: In rotational atherectomy (RA), the risk of coronary perforation is considered to increase when the wire is in contact with the healthy portion of the vessel. However, the relationship between the extent of wire bias in the healthy portion of the vessel and the risk of coronary perivascular trauma (CPT) has not been reported. METHODS: We examined 90 consecutive cases wherein intravascular ultrasound (IVUS) was performed before and after RA. The IVUS catheter in contact with the healthy region of the vessel was defined as the healthy portion wire bias (HWB), of which we measured the bias diameter, defined as the media-to-media length between the site where the IVUS catheter was in contact and the opposite side of the vessel. The bias ratio was defined as the ratio of the bias diameter to the short diameter at the region where the wire bias was the strongest. The relationship between the bias ratio and the CPT risk was evaluated. RESULTS: CPT was significantly higher in the HWB group than in the non-HWB group (9% vs. 0%, P = 0.048). In the HWB group, the bias ratio was significantly greater in the CPT group than in the non-CPT group (1.31 ±â€¯0.09 vs. 1.06 ±â€¯0.06; P < 0.0001). The cutoff value of the bias ratio for CPT was 1.2, which was the maximum value of the sum of sensitivity 100% and specificity 97%. CONCLUSIONS: Lesions without HWB had no CPT. CPT risk increased when the bias ratio exceeded 1.2.


Asunto(s)
Aterectomía Coronaria , Enfermedad de la Arteria Coronaria , Aterectomía Coronaria/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Vasos Coronarios/cirugía , Humanos , Resultado del Tratamiento , Ultrasonografía Intervencional
9.
J Nucl Cardiol ; 29(5): 2599-2611, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34427859

RESUMEN

BACKGROUND: Takotsubo cardiomyopathy (TTC) shows reversible hypokinesis in the left ventricular (LV) apical-half segment and hyperkinesis in the LV basal-half segment. However, the precise pathophysiological mechanism of TTC is unclear. Therefore, this study sought to clarify the nuclear characteristics, degree of myocardial damage, and serial change of TTC and rTTC using myocardial perfusion imaging. METHODS: We performed myocardial perfusion scintigraphy in 28 patients (TTC: 20, rTTC: 8) using Tc-99m sestamibi and assessed minimum percentage uptake (min-%-uptake), extent score (ES) and summed rest score (SRS) at acute and chronic phases. RESULTS: Min-%-uptake improved from the acute to the chronic phase (TTC: 54 [48-59]% vs 87 [81-90]%, P  < 0.01; rTTC: 60 [55-64]% vs 77 [71-79]%, P < 0.01), as did the ES (TTC: 32 [26-41]% vs 0.0 [0.0-6.0]%, P < 0.01; rTTC: 16 [12-34]% vs 0.0 [0.0-0.0]%, P = 0.02) and SRS (TTC: 4.5 [3.9-5.3] vs 0.0 [0.0-0.2], P < 0.01; rTTC: 3.6 [3.3-3.8] vs 0.0 [0.0-0.0], P = 0.01). CONCLUSION: Tc-99m sestamibi uptake was reduced in hypokinetic regions in the acute phase and improved in the chronic phase. TTC and rTTC may involve a reversible disorder of the myocardial cell membrane, mitochondria, and microcirculation.


Asunto(s)
Imagen de Perfusión Miocárdica , Cardiomiopatía de Takotsubo , Ventrículos Cardíacos , Humanos , Imagen de Perfusión Miocárdica/métodos , Cardiomiopatía de Takotsubo/diagnóstico por imagen , Tecnecio Tc 99m Sestamibi , Tomografía Computarizada por Rayos X
10.
Europace ; 24(8): 1284-1290, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34919657

RESUMEN

AIMS: This study aimed to investigate the intraventricular blood flow pattern of patients with left bundle branch block (LBBB) using four-dimensional flow magnetic resonance imaging (4D-flow MRI). METHODS AND RESULTS: We performed 4D-flow MRI for 16 LBBB patients (LBBB group) and 16 propensity score-matched patients with a normal QRS duration (non-LBBB group). The energy loss (EL) in the left ventricle was evaluated. In both groups, blood flow from the mitral valve to the apex of the heart and left ventricular (LV) outflow tract during LV diastole were observed. Vortices were also observed in both groups. There were two patterns of vortices: unidirectional clockwise rotation and counterclockwise rotation taking place from the mid-diastole to the systole (reverse pattern). The reverse pattern was observed significantly more frequently in the LBBB group (LBBB 94% vs. non-LBBB 19%, P < 0.001). The interobserver agreement for the streamline analysis was good (kappa = 0.68). The maximum EL was significantly higher in the LBBB group [LBBB 12 (11-15) mW vs. non-LBBB 8.0 (6.2-9.7) mW, P < 0.001]. CONCLUSION: Left bundle branch block patients may suffer from inefficient LV haemodynamics reflected by non-physiological counterclockwise vortices and increased EL. Thus, the shape of the vortices and EL in the left ventricle can serve as markers of LV mechanical dyssynchrony in LBBB patients and could be investigated as predictors of response to cardiac resynchronization therapy.


Asunto(s)
Terapia de Resincronización Cardíaca , Disfunción Ventricular Izquierda , Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos , Ventrículos Cardíacos , Humanos , Imagen por Resonancia Magnética , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Función Ventricular Izquierda
11.
Intern Med ; 60(23): 3749-3753, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34120999

RESUMEN

An 82-year-old woman with a history of bladder cancer presented with dyspnea and loss of consciousness. Contrast-enhanced computed tomography revealed pulmonary embolism, and emergency thrombus aspiration therapy was performed, but the thrombus was not aspirated. Echocardiography showed mobile masses in the heart and a right-to-left shunt due to a patent foramen ovale (PFO). Magnetic resonance imaging showed multiple cerebral infarctions. Surgical thrombectomy and PFO closure were performed, and the patient was diagnosed with intracardiac metastasis of bladder cancer based on intraoperative histopathology. This is a rare case of concomitant pulmonary and cerebral tumor embolism and intracardiac metastasis from bladder cancer.


Asunto(s)
Embolia Paradójica , Foramen Oval Permeable , Células Neoplásicas Circulantes , Embolia Pulmonar , Neoplasias de la Vejiga Urinaria , Anciano de 80 o más Años , Femenino , Humanos , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/etiología , Neoplasias de la Vejiga Urinaria/complicaciones , Neoplasias de la Vejiga Urinaria/diagnóstico , Neoplasias de la Vejiga Urinaria/cirugía
12.
BMJ Open ; 11(5): e046782, 2021 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-34039576

RESUMEN

INTRODUCTION: Pacing-induced cardiomyopathy occasionally occurs in patients undergoing pacemaker implantation. Although compared with right ventricular (RV) apical pacing, RV septal pacing can attenuate left ventricular dyssynchrony; the success rate of lead placement on the RV septum using the stylet system is low. Additionally, no randomised controlled trial has addressed the issue regarding the accuracy of RV lead placement on the RV septum using the stylet and delivery catheter systems. This study hypothesises that a newly available delivery catheter system can improve the accuracy of RV lead placement on the RV septum. METHODS AND ANALYSIS: In a multicentre, prospective, randomised, single-blind, controlled trial, 70 patients with pacemaker indication owing to atrioventricular block will be randomised to either the delivery catheter or stylet group before the pacemaker implantation procedure. The position of the RV lead tip will be assessed using ECG-gated cardiac CT in all patients within 4 weeks after pacemaker implantation. Lead tip positions are classified into three groups: (1) RV septum, (2) anterior/posterior edge of the RV septal wall and (3) RV free wall. The primary endpoint will be the success rate of RV lead tip placement on the RV septum, which will be evaluated using cardiac CT. ETHICS AND DISSEMINATION: This study will be conducted according to the stipulations of the Helsinki Declaration and the institutional review board of Hamamatsu University School of Medicine. The results of the study will be disseminated at several research conferences and will be published in peer-reviewed journals. TRIAL REGISTRATION NUMBER: jRCTs042200014; Pre-results.


Asunto(s)
Tabique Interventricular , Catéteres , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Estudios Multicéntricos como Asunto , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto , Método Simple Ciego , Tomografía Computarizada por Rayos X , Tabique Interventricular/diagnóstico por imagen
14.
Intern Med ; 60(19): 3113-3119, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-33840691

RESUMEN

A 41-year-old man was admitted with a chief complaint of dyspnea. Echocardiography showed diffuse severe hypokinesis in the left ventricle. Although his heart failure improved, high creatine kinase levels persisted. A muscle biopsy of the biceps brachii showed necrotic and regenerating fibers along with positive findings for major histocompatibility complex class I and membrane attack complex. He was diagnosed with antibody-negative immune-mediated necrotizing myopathy (IMNM). Steroid therapy was started, but he died due to ventricular fibrillation. Autopsy findings revealed CD68-positive macrophages in the myocardium and quadriceps. To our knowledge, this is the first case of antibody-negative IMNM with cardiac involvement.


Asunto(s)
Enfermedades Autoinmunes , Miositis , Adulto , Autoanticuerpos , Autopsia , Humanos , Masculino , Músculo Esquelético
15.
Heart Vessels ; 36(7): 1056-1063, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33507356

RESUMEN

Right ventricular (RV) septum is an alternate site for the placement of RV lead tip instead of RV apex. Recent studies have demonstrated that less than half of the RV leads targeted for septal implantation are placed on the RV septum using a conventional stylet system; new guiding catheter systems have become available for RV lead placement. This study aimed to investigate the usefulness of the delivery catheter system in lead placement on the RV septum when compared with the stylet system. We retrospectively evaluated 198 patients who underwent fluoroscopically guided pacemaker implantation with RV leads targeted to be placed in the RV septum and in whom computed tomography was incidentally and subsequently performed. A delivery catheter was used in 16 patients, and a stylet in 182 patients. The primary endpoint of this study was the success rate of RV lead placement on the RV septum. The proportion of RV lead placement on the RV septum was higher in the delivery catheter group than in the stylet group (100% vs. 44%; p < 0.001). In the stylet group, the lead tips were placed at the hinge in 92 cases (51%) and on the free wall in 9 cases (5%). Paced QRS duration was narrower in the delivery catheter group than in the stylet group (128 ± 16 vs. 150 ± 21 ms, p < 0.01). The delivery catheter system designated for pacing leads may aid in selecting RV septal sites and achieve good physiologic ventricular activation.


Asunto(s)
Arritmias Cardíacas/terapia , Marcapaso Artificial/estadística & datos numéricos , Función Ventricular Derecha/fisiología , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Electrocardiografía/métodos , Diseño de Equipo , Femenino , Fluoroscopía/métodos , Estudios de Seguimiento , Ventrículos Cardíacos , Humanos , Masculino , Estudios Retrospectivos , Tabique Interventricular
16.
J Interv Cardiol ; 2019: 4532862, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31772532

RESUMEN

OBJECTIVES: To examine the influence of hydrostatic pressure on fractional flow reserve (FFR) in vivo. BACKGROUND: Systematic differences in FFR values have been observed previously in the left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery (RCA). It has been suggested that as the hydrostatic pressure variations caused by the height differences between the catheter tip (mean aortic pressure (Pa)) and pressure-wire sensor (mean distal intracoronary pressure (Pd)) are small, intracoronary pressure need not be corrected. METHODS: Resting Pd/Pa and FFR values in 23 patients (27 lesions) were measured and compared in supine and prone positions. These values were corrected by hydrostatic pressure influenced by height levels and compared. Height differences between Pa and Pd were calculated using coronary computed tomography angiographies. RESULTS: In LAD, resting Pd/Pa and FFR values were significantly higher in the prone position than in the supine position (0.97 ± 0.05 vs 0.89 ± 0.04, P < 0.001 (resting Pd/Pa); 0.81 ± 0.09 vs 0.72 ± 0.07, P < 0.001 (FFR)). Conversely, in LCX and RCA, these values were significantly lower in the prone position (LCX: 0.93 ± 0.03 vs 0.98 ± 0.03, P < 0.001 (resting Pd/Pa); 0.84 ± 0.05 vs 0.89 ± 0.04, P < 0.001 (FFR); RCA: 0.91 ± 0.04 vs 0.98 ± 0.03, P=0.005 (resting Pd/Pa); 0.78 ± 0.07 vs 0.84 ± 0.07, P=0.019 (FFR)). FFR values corrected by hydrostatic pressure showed good correlations in the supine and prone positions (R 2 = 0.948 in LAD; R 2 = 0.942 in LCX; R 2 = 0.928 in RCA). CONCLUSIONS: Hydrostatic pressure variations due to height levels influence intracoronary pressure measurements and largely affect resting Pd/Pa and FFR, which might have caused systematic differences in FFR values between the anterior and posterior coronary territories.


Asunto(s)
Circulación Coronaria/fisiología , Reserva del Flujo Fraccional Miocárdico/fisiología , Presión Hidrostática , Posición Prona/fisiología , Posición Supina/fisiología , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Estenosis Coronaria/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
17.
Circ J ; 83(9): 1901-1907, 2019 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-31308318

RESUMEN

BACKGROUND: Although previous studies have suggested a certain prevalence of Fabry disease (FD) in left ventricular hypertrophy (LVH) patients, the screening of FD is difficult because of its wide-ranging clinical phenotypes. We aimed to clarify the utility of combined measurement of plasma globotriaosylsphingosine (lyso-Gb3) concentration and α-galactosidase A activity (α-GAL) as a primary screening of FD in unexplained LVH patients.Methods and Results:Between 2014 and 2016, both lyso-Gb3 and α-GAL were measured in 277 consecutive patients (male 215, female 62, age 25-79 years) with left ventricular wall thickness >12 mm on echocardiogram: 5 patients (1.8%) screened positive (2 (0.7%) showed high lyso-Gb3 and 4 (1.4%) had low α-GAL levels). Finally, 2 patients (0.7%) were diagnosed with clinically significant FD. In 1 case, a female heterozygote with normal α-GAL levels had genetic variants of unknown significance and was diagnosed as FD by endomyocardial biopsy. The other case was a male chronic renal failure patient requiring hemodialysis, and he had a p.R112H mutation. In both cases there were high lyso-Gb3 levels. CONCLUSIONS: The serum lyso-Gb3 level can be relevant for clinically significant FD, and combined measurement of lyso-Gb3 and α-GAL can provide better screening of FD in unexplained LVH patients.


Asunto(s)
Enfermedad de Fabry/sangre , Glucolípidos/sangre , Hipertrofia Ventricular Izquierda/sangre , Esfingolípidos/sangre , Adolescente , Adulto , Anciano , Biomarcadores/sangre , Enfermedad de Fabry/diagnóstico por imagen , Enfermedad de Fabry/genética , Enfermedad de Fabry/fisiopatología , Femenino , Predisposición Genética a la Enfermedad , Humanos , Hipertrofia Ventricular Izquierda/diagnóstico por imagen , Hipertrofia Ventricular Izquierda/genética , Hipertrofia Ventricular Izquierda/fisiopatología , Japón , Masculino , Persona de Mediana Edad , Mutación , Valor Predictivo de las Pruebas , Estudios Prospectivos , Función Ventricular Izquierda , Remodelación Ventricular , Adulto Joven , alfa-Galactosidasa/sangre , alfa-Galactosidasa/genética
18.
J Cardiol Cases ; 15(5): 145-149, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-30279763

RESUMEN

Heparin-induced thrombocytopenia (HIT) is an adverse immune-mediated drug reaction that is associated with thromboembolic complications. We report the case of an 82-year-old man with unstable angina pectoris who suffered from recurrent arterial thromboembolism due to HIT. Coronary angiography (CAG) was performed while we administered unfractionated heparin bolus. CAG showed triple-vessel disease without left main coronary artery. We performed elective percutaneous coronary angioplasty (PCI) to the left anterior descending coronary artery (LAD). The sudden thrombus formation in the LAD occurred during the procedure. We suspected HIT and administered argatroban. We deployed four everolimus-eluting stents in the LAD and intra-aortic balloon pumping (IABP) support was started. The platelet counts were rapidly reduced almost 50% next day after PCI and IgG-specific anti-PF4/heparin antibodies were elevated. Multiple cerebral infarctions were detected by magnetic resonance imaging after the PCI. The patient received the continuous argatroban administration and IABP support for 4 days. Subacute stent thrombosis occurred after quitting argatroban. We performed thrombus aspiration and fibrinolytic treatment. Finally we re-inserted IABP and stabilized the hemodynamic state. Right popliteal arterial thromboembolism occurred after emergency PCI. Argatroban is essential and following oral anticoagulant therapy is necessary to prevent thromboembolic complications. .

19.
Masui ; 65(4): 336-40, 2016 Apr.
Artículo en Japonés | MEDLINE | ID: mdl-27188100

RESUMEN

Currently, the immediate extubation in the operating room is necessary for the patients undergoing off-pump coronary artery bypass (OPCAB). To achieve UFTA, anesthesiologists should control general anesthesia. We report the case series of UFTA for the patients undergone OPCAB at our hospital. Forty patients receiving OPCAB between April 2012 and April 2014 were retrospectively analyzed. We divided the patients into those extubated in the operating room (Extubation group) and those not (Intubation group). The extubation criteria included adequate revascularization, adequate hemostasis, ratio between Pa(O2) and FI(O2) more than 250, body temperature above 36 degrees C, stable hemodynamics without noradrenaline, without IABP, and normal postoperative chest X-ray. Twenty-three patients (70% of the scheduled and 20% of the emergency patients) were included in our criteria and could be extubated in the operating room. One patient was re-intubated due to asthma attack following extubation in the operating room. The sucess rate of immediate extubation was 95.7% by our criteria. There were no significant differences in age, sex, BMI, duration of anesthesia, and amount of hemorrhage between the 2 groups. We believe that UFTA for OPCAB patients may be possible under carefull decision by extubation criteria.


Asunto(s)
Anestesia General/métodos , Puente de Arteria Coronaria Off-Pump/métodos , Anciano , Extubación Traqueal , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Quirófanos , Estudios Retrospectivos
20.
Acta Otolaryngol ; 129(6): 674-80, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18728915

RESUMEN

CONCLUSIONS: Computer processing of conventional CT images can provide virtual endoscopic images (VEIs). Surgeons observing these images feel as if they are observing the lesion using an endoscope. Simulation based on animated VEIs before endoscopic sinus surgery (ESS) is useful for the improvement of surgical safety and surgeons' education. Although the production of VEIs requires certain surgical experience, after the production of VEIs, surgeons can repeat simulation of a surgical procedure and have confidence in the actual operation. OBJECTIVE: We investigated the clinical application of CT-reconstructed VEIs as a support system for ESS. MATERIALS AND METHODS: A GE Light Speed Ultra 16 as a 16-slice CT scanner and Advantage Workstation 4.2 were used. Software called Navigator in this workstation allows the production of CT-reconstructed VEIs. We applied simulation based on VEIs to endoscopic operations for mucocele or sinusitis. RESULTS: In nine cases of mucoceles and sinusitis, simulation based on animated VEIs was applied. According to the simulation, surgeries were performed, and the mucoceles and obstructed sinuses could be opened readily and safely. This system was more effective when there were landmarks such as polyps or irregular mucosal surfaces allowing macroscopic confirmation ahead of the viewpoint.


Asunto(s)
Endoscopía/métodos , Mucocele/cirugía , Enfermedades de los Senos Paranasales/cirugía , Cirugía Asistida por Computador , Interfaz Usuario-Computador , Anciano , Simulación por Computador , Senos Etmoidales/diagnóstico por imagen , Senos Etmoidales/cirugía , Femenino , Seno Frontal/diagnóstico por imagen , Seno Frontal/cirugía , Humanos , Imagenología Tridimensional , Masculino , Seno Maxilar/diagnóstico por imagen , Seno Maxilar/cirugía , Persona de Mediana Edad , Mucocele/diagnóstico por imagen , Enfermedades de los Senos Paranasales/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Programas Informáticos , Seno Esfenoidal/diagnóstico por imagen , Seno Esfenoidal/cirugía , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...