Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 178
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38752951

RESUMEN

BACKGROUND: A lesion-level risk prediction for acute coronary syndrome (ACS) needs better characterization. OBJECTIVES: This study sought to investigate the additive value of artificial intelligence-enabled quantitative coronary plaque and hemodynamic analysis (AI-QCPHA). METHODS: Among ACS patients who underwent coronary computed tomography angiography (CTA) from 1 month to 3 years before the ACS event, culprit and nonculprit lesions on coronary CTA were adjudicated based on invasive coronary angiography. The primary endpoint was the predictability of the risk models for ACS culprit lesions. The reference model included the Coronary Artery Disease Reporting and Data System, a standardized classification for stenosis severity, and high-risk plaque, defined as lesions with ≥2 adverse plaque characteristics. The new prediction model was the reference model plus AI-QCPHA features, selected by hierarchical clustering and information gain in the derivation cohort. The model performance was assessed in the validation cohort. RESULTS: Among 351 patients (age: 65.9 ± 11.7 years) with 2,088 nonculprit and 363 culprit lesions, the median interval from coronary CTA to ACS event was 375 days (Q1-Q3: 95-645 days), and 223 patients (63.5%) presented with myocardial infarction. In the derivation cohort (n = 243), the best AI-QCPHA features were fractional flow reserve across the lesion, plaque burden, total plaque volume, low-attenuation plaque volume, and averaged percent total myocardial blood flow. The addition of AI-QCPHA features showed higher predictability than the reference model in the validation cohort (n = 108) (AUC: 0.84 vs 0.78; P < 0.001). The additive value of AI-QCPHA features was consistent across different timepoints from coronary CTA. CONCLUSIONS: AI-enabled plaque and hemodynamic quantification enhanced the predictability for ACS culprit lesions over the conventional coronary CTA analysis. (Exploring the Mechanism of Plaque Rupture in Acute Coronary Syndrome Using Coronary Computed Tomography Angiography and Computational Fluid Dynamics II [EMERALD-II]; NCT03591328).

2.
Asia Pac J Clin Oncol ; 19(3): 347-354, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36281655

RESUMEN

PURPOSE: To evaluate the prognostic value of human epidermal growth factor receptor 2 (HER2) status and how to use HER2-targeted therapy in breast cancer (BC) with brain metastases (BM) treated with radiotherapy. METHODS: We retrospectively reviewed the data of 103 BC patients with parenchymal BM treated with radiotherapy. We collected data on the hormone receptor (HR), HER-2 amplification status, and systemic therapy after treatment for BM. The primary outcome was overall survival (OS), which was calculated from the diagnosis of BM to death. RESULTS: The median follow-up time from the diagnosis of the first BM was 9.1 months (range, .7-88 months). The 2-year OS of the HR-positive and HER2-positive (HR+HER2+) BC (31.3 mo) was significantly better than those of the HR-HER2+ (9,5 mo, p=.002), HR+HER2- (9.9mo, p=.003), and triple-negative BC (3.9 mo, p<.001) ( . Of the 36 HER2-positive patients, 31 patients treated with HER2-targeted therapy after radiotherapy for BM had a significantly better 2-year OS than those who did not receive HER2-targeted therapy (43% vs. 0%; p < .001). Among the 31 patients treated with HER2-targeted therapy, the 2-year OS for those treated with multiple anti-HER2 agents during the entire course of treatment was significantly higher than that for patients treated with a single agent (60% vs. 24%; p = .006). CONCLUSIONS: HR+HER2+ BC patients with BM treated with radiotherapy show a better prognosis than other subtypes. For HER2-positive patients with good prognosis, it may be important to continue HER2-targeted therapy appropriately after radiotherapy for BM.


Asunto(s)
Neoplasias Encefálicas , Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/patología , Pronóstico , Estudios Retrospectivos , Receptor ErbB-2/metabolismo , Neoplasias Encefálicas/tratamiento farmacológico , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundario
3.
Circ J ; 86(5): 857-865, 2022 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-35197394

RESUMEN

BACKGROUND: This study aimed to quantitatively evaluate myocardial perfusion single-photon emission computed tomography (SPECT) using an original analysis tool in the compartment model for detecting regional significant coronary artery disease (CAD).Methods and Results: This study analyzed 41 patients (median age, 76 years) with suspected or known CAD who underwent both dynamic SPECT using 99 mTc-tetrofosmin and invasive coronary angiography. The quantitative analysis was performed using a single-tissue compartment model to evaluate the diagnostic performance of the myocardial flow reserve (MFR) for regional significant CAD, excluding infarcted territories. In the regional analysis, 114 vessels were assessed, of which 31 were diagnosed as significant coronary lesions (≥70% stenosis and/or fraction flow reserve ≤0.8). The MFR of regional significant CAD was significantly lower than that of non-significant CAD (1.11 [0.97-1.31] vs. 1.74 [1.30-2.27]; P<0.001). In the receiver operating characteristic curve analysis, the MFR displayed an area under the curve (AUC) of 0.81. While analyzing each coronary artery territory, the diagnostic performance of the MFR value in the left anterior descending (LAD) artery territory was found to be significantly higher than that found in qualitative assessment (AUC: 0.84 vs. 0.61). CONCLUSIONS: A quantitative analysis of dynamic SPECT data facilitated detecting regional CAD. For the LAD artery, the MFR displayed a higher diagnostic performance than the qualitative assessment of conventional myocardial perfusion SPECT.


Asunto(s)
Enfermedad de la Arteria Coronaria , Imagen de Perfusión Miocárdica , Anciano , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Humanos , Imagen de Perfusión Miocárdica/métodos , Perfusión , Curva ROC , Tomografía Computarizada de Emisión de Fotón Único/métodos
4.
Heart Vessels ; 37(1): 31-39, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34232385

RESUMEN

Computed tomography (CT)-derived three-dimensional maximum principal strain (MP-strain) can provide incremental value to coronary CT angiography for cardiac dysfunction assessment with high diagnostic performance in patients with myocardial infarction. Global longitudinal strain (GLS) measured using two-dimensional speckle tracking echocardiography (2D-STE) is more sensitive than left ventricular ejection fraction (LVEF) for detecting early myocardial dysfunction. We aimed to compare CT-derived MP-strain with each of 2D-STE-derived strains (i.e., longitudinal, circumferential, and radial strains), and identify the major determinants of CT-derived MP-strain among 2D-STE-derived strains. We studied 51 patients who underwent cardiac CT and echocardiography. CT images were reconstructed at every 5% (0-95%) of the RR interval. A dedicated workstation was used to analyze CT-derived MP-strain on the 16-segment model. We calculated CT-derived global MP-strain with all the 16 segments on a per patient basis. Pearson's test was used to assess correlations between CT-derived MP-strain and STE-strain at global and segmental levels. The intra-class correlation coefficient for interobserver agreement for CT-derived global MP-strain was 0.98 (95% confidence interval 0.96-0.99). The low-CT-derived global MP-strain group (≤ 0.43) had more patients with LV dysfunction than the high-CT-derived global MP-strain group (> 0.43). CT-derived global MP-strain was associated with STE-GLS (r = 0.738, P < 0.001), global circumferential strain (r = 0.646, P < 0.001), and global radial strain (r = 0.432, P = 0.001). In multivariate analysis, STE-GLS had the strongest association to CT-derived global MP-strain among three directional STE-strains and LVEF by echocardiography (standardized coefficient = - 0.527, P < 0.001). STE-GLS is a major determinant of CT-derived global MP-strain. CT-derived MP-strain may enhance the value of coronary CT angiography by adding functional information to CT-derived LVEF.


Asunto(s)
Ecocardiografía Tridimensional , Disfunción Ventricular Izquierda , Función Ventricular Izquierda , Ecocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Reproducibilidad de los Resultados , Volumen Sistólico , Tomografía Computarizada por Rayos X , Disfunción Ventricular Izquierda/diagnóstico por imagen
5.
Intern Med ; 60(23): 3671-3678, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34853256

RESUMEN

Objective Coronary plaques with low attenuation on computed tomography (CT) angiography may indicate vulnerable plaques. However, plaque CT attenuation is reported to be significantly affected by intracoronary attenuation. Recently, the diluted-contrast injection protocol was established to facilitate more uniform intracoronary attenuation than can be achieved with the generally used body-weight-adjusted protocol. We validated the relationship between low-attenuation plaque on CT and lipid-rich plaque using integrated backscatter-intravascular ultrasound (IB-IVUS) as the standard reference. Methods Plaques were divided into tertiles (T1, T2, and T3) according to the plaque CT attenuation, calculated as the average of five intra-plaque regions of interest, and compared with the plaque characteristics noted on IB-IVUS. Patients Patients who underwent both CT angiography using a diluted-contrast injection protocol and IB-IVUS were retrospectively analyzed. Results Thirty-nine plaques in 32 patients were analyzed by CT angiography and IB-IVUS. The median plaque CT attenuation (Hounsfield units) of each tertile was 30 (T1), 48 (T2), and 68 (T3). Although no significant difference was noted in conventional quantitative IVUS parameters (e.g. plaque burden), the T1 with lowest plaque CT attenuation had the highest percentage lipid area by IB-IVUS [75.1% (T1), 57.8% (T2), and 50.8% (T3), respectively, p<0.01]. Furthermore, the plaque CT attenuation had a significant negative correlation with the percentage lipid area (r=-0.59, p<0.01). Conclusion CT angiography-based plaque characterization using a diluted-contrast injection protocol may aid in the quantitative detection of lipid-rich plaque.


Asunto(s)
Angiografía por Tomografía Computarizada , Enfermedad de la Arteria Coronaria , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Humanos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Ultrasonografía Intervencional
6.
Acta Radiol Open ; 10(9): 20584601211044779, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34594576

RESUMEN

BACKGROUND: Deep learning-based methods have been used to denoise magnetic resonance imaging. PURPOSE: The purpose of this study was to evaluate a deep learning reconstruction (DL Recon) in cardiovascular black-blood T2-weighted images and compare with intensity filtered images. MATERIAL AND METHODS: Forty-five DL Recon images were compared with intensity filtered and the original images. For quantitative image analysis, the signal to noise ratio (SNR) of the septum, contrast ratio (CR) of the septum to lumen, and sharpness of the endocardial border were calculated in each image. For qualitative image quality assessment, a 4-point subjective scale was assigned to each image (1 = poor, 2 = fair, 3 = good, 4 = excellent). RESULTS: The SNR and CR were significantly higher in the DL Recon images than in the intensity filtered and the original images (p < .05 in each). Sharpness of the endocardial border was significantly higher in the DL Recon and intensity filtered images than in the original images (p < .05 in each). The image quality of the DL Recon images was significantly better than that of intensity filtered and original images (p < .001 in each). CONCLUSIONS: DL Recon reduced image noise while improving image contrast and sharpness in the cardiovascular black-blood T2-weight sequence.

7.
Eur J Radiol ; 142: 109838, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34217136

RESUMEN

PURPOSE: This study aimed to compare the characteristics of triple-negative breast cancer (TNBC) with non-TNBC on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and synthetic MRI. METHOD: This retrospective study included 79 patients with histopathologically proven breast cancer (TNBC: 16, non-TNBC: 63) who underwent synthetic MRI. Using synthetic MR images, we obtained T1 and T2 relaxation times in breast lesions before (Pre-T1, Pre-T2, Pre-PD) and after (Gd-T1, Gd-T2, Gd-PD) contrast agent injection. Subsequently, we calculated the ΔT1 (Pre-T1 - Gd-T1), ΔT2 (Pre-T2 - Gd-T2), Pre-T1/T2, and Gd-T1/T2. We compared the aforementioned quantitative values, as well as several morphologic features between TNBCs and non-TNBCs that were identified on DCE-MRI. RESULTS: The multivariate analyses revealed that the Pre-T2 (P = 0.037) and the presence of rim enhancement (P-RIM) (P = 0.034) were significant and independent predictors of TNBC. The area under the receiver operating characteristics curve for all breast cancers was greater when a combination of Pre-T2 and P-RIM (Pre-T2+P-RIM; Method 3, AUC (area under the curve) = 0.858) was used to distinguish between TNBCs and non-TNBCs versus the use of either Pre-T2 alone (Method 1, AUC = 0.786) or P-RIM alone (Method 2, AUC = 0.747). CONCLUSIONS: Pre-T2 obtained using synthetic MRI and P-RIM identified on DCE-MRI allowed the differentiation between TNBCs and non-TNBCs. However, these results are preliminary and need to be verified by further studies.


Asunto(s)
Neoplasias de la Mama , Neoplasias de la Mama Triple Negativas , Mama , Neoplasias de la Mama/diagnóstico por imagen , Medios de Contraste , Femenino , Humanos , Imagen por Resonancia Magnética , Estudios Retrospectivos , Neoplasias de la Mama Triple Negativas/diagnóstico por imagen
8.
J Appl Clin Med Phys ; 22(7): 66-76, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33955161

RESUMEN

Volumetric-modulated arc therapy (VMAT) requires highly accurate control of multileaf collimator (MLC) movement, rotation speed of linear accelerator gantry, and monitor units during irradiation. Pretreatment validation and monitoring of these factors during irradiation are necessary for appropriate VMAT treatment. Recently, a gantry mounted transmission detector "Delta4 Discover® (D4D)" was developed to detect errors in delivering doses and dose distribution immediately after treatment. In this study, the performance of D4D was evaluated. Simulation plans, in which the MLC position was displaced by 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 mm from the clinically used original plans, were created for ten patients who received VMAT treatment for prostate cancer. Dose deviation (DD), distance-to-agreement (DTA), and gamma index analysis (GA) for each plan were evaluated by D4D. These results were compared to the results (DD, DTA and GA) measured by Delta4 Phantom + (D4P). We compared the deviations between the planned and measured values of the MLC stop positions A-side and B-side in five clinical cases of prostate VMAT during treatment and measured the GA values. For D4D, when the acceptable errors for DD, DTA, and GA were determined to be ≤3%, ≤2 mm, and ≤3%/2 mm, respectively, the minimum detectable errors in the MLC position were 2.0, 1.5, and 1.5 mm based on DD, DTA, and GA respectively. The corresponding minimum detectable MLC position errors were 2.0, 1.0, and 1.5 mm, respectively, for D4P. The deviation between the planned and measured position of MLC stopping point of prostate VMAT during treatment was stable at an average of -0.09 ± 0.05 mm, and all GA values were above 99.86%. In terms of delivering doses and dose distribution of VMAT, error detectability of D4D was comparable to that of D4P. The transmission-type detector "D4D" is thus suitable for detecting delivery errors during irradiation.


Asunto(s)
Neoplasias de la Próstata , Radioterapia de Intensidad Modulada , Humanos , Masculino , Aceleradores de Partículas , Fantasmas de Imagen , Neoplasias de la Próstata/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
9.
J Cardiovasc Magn Reson ; 23(1): 10, 2021 02 22.
Artículo en Inglés | MEDLINE | ID: mdl-33618722

RESUMEN

BACKGROUND: Feature tracking (FT) has become an established tool for cardiovascular magnetic resonance (CMR)-based strain analysis. Recently, the compressed sensing (CS) technique has been applied to cine CMR, which has drastically reduced its acquisition time. However, the effects of CS imaging on FT strain analysis need to be carefully studied. This study aimed to investigate the use of CS cine CMR for FT strain analysis compared to conventional cine CMR. METHODS: Sixty-five patients with different left ventricular (LV) pathologies underwent both retrospective conventional cine CMR and prospective CS cine CMR using a prototype sequence with the comparable temporal and spatial resolution at 3 T. Eight short-axis cine images covering the entire LV were obtained and used for LV volume assessment and FT strain analysis. Prospective CS cine CMR data over 1.5 heartbeats were acquired to capture the complete end-diastolic data between the first and second heartbeats. LV volume assessment and FT strain analysis were performed using a dedicated software (ci42; Circle Cardiovasacular Imaging, Calgary, Canada), and the global circumferential strain (GCS) and GCS rate were calculated from both cine CMR sequences. RESULTS: There were no significant differences in the GCS (- 17.1% [- 11.7, - 19.5] vs. - 16.1% [- 11.9, - 19.3; p = 0.508) and GCS rate (- 0.8 [- 0.6, - 1.0] vs. - 0.8 [- 0.7, - 1.0]; p = 0.587) obtained using conventional and CS cine CMR. The GCS obtained using both methods showed excellent agreement (y = 0.99x - 0.24; r = 0.95; p < 0.001). The Bland-Altman analysis revealed that the mean difference in the GCS between the conventional and CS cine CMR was 0.1% with limits of agreement between -2.8% and 3.0%. No significant differences were found in all LV volume assessment between both types of cine CMR. CONCLUSION: CS cine CMR could be used for GCS assessment by CMR-FT as well as conventional cine CMR. This finding further enhances the clinical utility of high-speed CS cine CMR imaging.


Asunto(s)
Cardiopatías/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética , Función Ventricular Izquierda , Remodelación Ventricular , Anciano , Femenino , Cardiopatías/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Estudios Retrospectivos
11.
Radiol Case Rep ; 16(2): 377-380, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33318777

RESUMEN

Three-dimensional high-resolution late gadolinium enhancement (3D HR LGE) magnetic resonance imaging (MRI) using compressed sensing can help detect small myocardial infarcts. We discuss the case of an 11-year-old child with an anomalous aortic origin of the left coronary artery. Since he was suspected to have coronary stenosis due to anomalous aortic origin of the left coronary artery, cardiovascular MRI, including conventional two-dimensional (2D) LGE MRI and HR 3D LGE MRI, was conducted. Myocardial scars were not clearly observed via 2D LGE MRI; however, 3D HR MRI revealed subendocardial infarction of the anteroseptal wall, which corresponded to the left coronary artery. By applying the compressed sensing technique, 3D HR LGE, MRI enables a detailed assessment of small myocardial infarcts in a clinically feasible scan time.

12.
J Nucl Cardiol ; 28(5): 1851-1860, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-31713117

RESUMEN

BACKGROUND: This study evaluated corrected relative flow reserve (RFR) derived from 13N-ammonia positron emission tomography (PET) combined with coronary computed tomography angiography (CTA). METHODS: We analyzed 61 patients who underwent coronary CTA, 13N-ammonia PET, and invasive coronary angiography. Triple-vessel disease were excluded. Conventional RFRs were calculated as the ratio of hyperemic myocardial blood flow (hMBF) of hypoperfusion areas to those of non-ischemic lesions. Corrected RFRs were calculated using PET and coronary CTA to adjust coronary territories to their feeding vessels. Diagnostic performance was compared to detect obstructive coronary lesions. RESULTS: Of the 180 vessels analyzed, 50 were diagnosed as obstructive lesions (≥ 70% stenosis and/or fractional flow reserve value ≤ 0.8). The coronary flow reserve (CFR), hMBF, conventional RFR, and corrected RFR of obstructive lesions were significantly lower than those of non-obstructive lesions. In receiver operating characteristic curve analysis, these quantitative PET measurements had area under the curve of 0.67, 0.71, 0.89, and 0.92, respectively. Diagnostic performance differences between corrected and conventional RFR were not statistically significant. CONCLUSION: In patients with single or double vessel disease, indices of RFR, with or without coronary angiographic guidance of the reference coronary territory, are better discriminators of flow-limiting stenoses than hMBF and CFR.


Asunto(s)
Angiografía por Tomografía Computarizada , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico/fisiología , Radioisótopos de Nitrógeno , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiofármacos , Anciano , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Estudios Retrospectivos
13.
J Magn Reson Imaging ; 53(2): 381-391, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32914921

RESUMEN

BACKGROUND: The addition of synthetic MRI might improve the diagnostic performance of dynamic contrast-enhanced MRI (DCE-MRI) in patients with breast cancer. PURPOSE: To evaluate the diagnostic value of a combination of DCE-MRI and quantitative evaluation using synthetic MRI for differentiation between benign and malignant breast masses. STUDY TYPE: Retrospective, observational. POPULATION: In all, 121 patients with 131 breast masses who underwent DCE-MRI with additional synthetic MRI were enrolled. FIELD STRENGTH/SEQUENCE: 3.0 Tesla, T1 -weighted DCE-MRI and synthetic MRI acquired by a multiple-dynamic, multiple-echo sequence. ASSESSMENT: All lesions were differentiated as benign or malignant using the following three diagnostic methods: DCE-MRI type based on the Breast Imaging-Reporting and Data System; synthetic MRI type using quantitative evaluation values calculated by synthetic MRI; and a combination of the DCE-MRI + Synthetic MRI types. The diagnostic performance of the three methods were compared. STATISTICAL TESTS: Univariate (Mann-Whitney U-test) and multivariate (binomial logistic regression) analyses were performed, followed by receiver-operating characteristic curve (AUC) analysis. RESULTS: Univariate and multivariate analyses showed that the mean T1 relaxation time in a breast mass obtained by synthetic MRI prior to injection of contrast agent (pre-T1 ) was the only significant quantitative value acquired by synthetic MRI that could independently differentiate between malignant and benign breast masses. The AUC for all enrolled breast masses assessed by DCE-MRI + Synthetic MRI type (0.83) was significantly greater than that for the DCE-MRI type (0.70, P < 0.05) or synthetic MRI type (0.73, P < 0.05). The AUC for category 4 masses assessed by the DCE-MRI + Synthetic MRI type was significantly greater than that for those assessed by the DCE-MRI type (0.74 vs. 0.50, P < 0.05). DATA CONCLUSION: A combination of synthetic MRI and DCE-MRI improves the accuracy of diagnosis of benign and malignant breast masses, especially category 4 masses. Level of Evidence 4 Technical Efficacy Stage 2 J. MAGN. RESON. IMAGING 2021;53:381-391.


Asunto(s)
Neoplasias de la Mama , Medios de Contraste , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Diagnóstico Diferencial , Humanos , Imagen por Resonancia Magnética , Estudios Retrospectivos
14.
J Cardiovasc Magn Reson ; 22(1): 66, 2020 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-32921308

RESUMEN

BACKGROUND: Cardiovascular magnetic resonance (CMR) late gadolinium enhancement (LGE) is a valuable technique for detecting myocardial disorders and fibrosis. However, we sometimes observe a linear, mid-wall high intensity signal in the basal septum in the short axis view, which often presents diagnostic difficulties in the clinical setting. The purpose of this study was to compare the linear, mid-wall high intensity in the basal septum identified by LGE with the anterior septal perforator arteries identified by coronary computed tomography angiography (CorCTA). METHODS: We retrospectively selected 148 patients who underwent both CorCTA and CMR LGE within 1 year. In the interpretation of LGE, we defined a positive linear high intensity (LHI+) as follows: ① LHI in the basal septum and ② observable for 1.5 cm or more. All other patients were defined as a negative LHI (LHI-). In LHI+ patients, we assessed the correlation between the LHI length and the septal perforator artery length on CorCTA. We also compared the length of the septal perforator artery on CorCTA between LHI+ patients and LHI- patients. RESULTS: A population of 111 patients were used for further analysis. Among these , there were 55 LHI+ patients and 56 LHI- patients. In LHI+ patients, linear regression analysis revealed that there was a good agreement between LGE LHI and septal perforator arteries by CorCTA in terms of length measurements. The measured length of the anterior septal perforator arteries was significantly shorter in LHI- patients than in LHI+ patients (10 ± 8 mm vs. 21 ± 8 mm; P < 0.05). CONCLUSIONS: The LHI observed in the basal septum on short axis LGE may reflect contrast enhancement of the anterior septal perforator arteries. It is important to interpret this septal LHI against knowledge of anatomic structure, to avoid misinterpretations of LGE and prevent misdiagnosis.


Asunto(s)
Cardiomiopatías/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Medios de Contraste/administración & dosificación , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Gadolinio DTPA/administración & dosificación , Tabiques Cardíacos/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Isquemia Miocárdica/diagnóstico por imagen , Anciano , Artefactos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos
15.
Int J Cardiol Heart Vasc ; 30: 100587, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32743044

RESUMEN

BACKGROUND: Sarcoidosis is a systemic inflammatory disorder and can often affect any other organs beyond the heart. Whole-body 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) is used to detect not only cardiac but also extra-cardiac involvement of sarcoidosis. However, the features and clinical impact of extra-cardiac lesions have not yet been fully elucidated. Therefore, this study aimed to clarify these using FDG-PET. METHODS AND RESULTS: We enrolled 120 consecutive patients with abnormal findings clinically suggesting cardiac sarcoidosis who underwent whole-body FDG-PET. In this study, a patient with suspected cardiac sarcoidosis was defined as one having both clinically suspected findings and FDG-PET positive cardiac uptake. Subsequently, a total of 36 patients with suspected cardiac sarcoidosis were found and analyzed. Extra-cardiac involvement was detected in 35 lesions of 14 patients (39% per patient). In particular, the extra-cardiac lesions were widely distributed throughout the body, and mediastinal/hilar lymph node involvement was most commonly observed. In most of the patients (93% per patient, 13/14), the extra-cardiac lesions were localized in the regions that were considered more accessible with less risk of complication compared with endomyocardial biopsy (EMB). Based on the FDG-PET findings, 8 patients underwent extra-cardiac biopsy without complication, and its diagnostic sensitivity for histological sarcoidosis was high (75%, 6/8). Moreover, FDG-PET-guided extra-cardiac biopsy could confirm histological sarcoidosis in 4 lesions that EMB failed to prove. CONCLUSIONS: Extra-cardiac involvement in patients with suspected cardiac sarcoidosis was relatively high. FDG-PET-guided extra-cardiac biopsy may be safe and useful for the imaging based diagnosis of cardiac sarcoidosis.

16.
Eur J Radiol ; 129: 109124, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32563962

RESUMEN

PURPOSE: This study aimed to compare the efficacy of compressed sensing (CS) and conventional coronary magnetic resonance angiography (CMRA) in detecting coronary artery stenosis. METHOD: Twenty-eight patients underwent 3 T contrast-enhanced CS and conventional CMRA; for late gadolinium enhancement (LGE) imaging, 0.1 mmol/kg gadolinium medium was infused. CS CMRA was scanned within the LGE waiting time. After the LGE image acquisition, conventional CMRA was performed. The diagnostic performance of both CMRA for the detection of significant stenosis was evaluated using coronary angiography as a reference. The analysis was conducted to examine the three main coronary artery vessels: left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery (RCA). These arteries were subdivided into 8 segments (LAD; main, proximal, and middle, LCX; proximal and distal, RCA; proximal, middle, and distal). Of these, hypoplastic segments and vessels after coronary stent implantation were excluded. The acquisition time of CS CMRA was compared with that of conventional CMRA. RESULTS: The coronary arteries were evaluated in 197 segments. The sensitivity, specificity, and accuracy of CS CMRA in detecting significant stenosis were 85.2 %, 82.5 %, and 83.2 %, respectively, on a per-segment basis. Those of conventional CMRA were 85.2 %, 86.7 %, and 86.3 %, respectively. The acquisition time was 207 s (range, 144-258 s) for CS and 975 s (range, 787-1226s) for conventional CMRA (p < 0.001). CONCLUSIONS: Similar to conventional CMRA, CS CMRA has shown potential for the detection of significant coronary artery stenosis.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Anciano , Medios de Contraste , Estenosis Coronaria/patología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Femenino , Gadolinio , Humanos , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Eur Radiol ; 30(11): 6109-6117, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32556462

RESUMEN

OBJECTIVES: This study evaluated the characteristics of left ventricular maximum principal strain (LV-MPS) using cardiac CT in subjects with normal LV function. METHODS: Of 973 subjects who underwent retrospective electrocardiogram-gated cardiac CT using a third-generation dual-source CT without beta-blocker administration, 31 subjects with preserved LV ejection fraction ≥ 55% assessed by echocardiography without coronary artery stenosis and cardiac pathology were retrospectively identified. CT images were reconstructed every 5% (0-95%) of the RR interval. LV-MPS and the time to peak (TTP) were analyzed using the 16-segment model and compared among three levels (base, mid, and apex) and among four regions (anterior, septum, inferior, and lateral) using the Steel-Dwass test. The intra- and inter-observer reproducibilities for LV-MPS were calculated using intraclass correlation coefficients (ICCs). RESULTS: The intra- and inter-observer ICCs (95% confidence interval) for peak LV-MPS were 0.96 (0.94-0.97) and 0.94 (0.92-0.96), respectively. The global peak LV-MPS (median, inter-quantile range) was 0.59 (0.55-0.72). The regional LV-MPS significantly increased in the order of the basal (0.54, 0.49-0.59), mid-LV (0.57, 0.53-0.65), and apex (0.68, 0.60-0.84) (p < 0.05, in each), and was significantly higher in the lateral wall (0.66, 0.60-0.77), while that in the septal region (0.47, 0.44-0.54) was the lowest among the four LV regions (all p < 0.05). No significant difference in TTP was seen among the myocardial levels and regions. CONCLUSION: CT-derived LV-MPS is reproducible and quantitatively represents synchronized myocardial contraction with heterogeneous values in subjects with normal LV function. KEY POINTS: • CT-derived left ventricular maximum principal strain analysis allows highly reproducible quantitative assessments of left ventricular myocardial contraction. • In subjects with normal cardiac function, the peak value of CT-derived left ventricular maximum principal strain is the highest in the apical level and in the lateral wall and the lowest in the septum. • The regional peak left ventricular maximum principal strain shows intra-ventricular heterogeneity on a per-patient basis, but myocardial contraction is globally synchronized in subjects with normal cardiac function seen on cardiac CT.


Asunto(s)
Ventrículos Cardíacos/diagnóstico por imagen , Contracción Miocárdica/fisiología , Volumen Sistólico/fisiología , Tomografía Computarizada por Rayos X/métodos , Función Ventricular Izquierda/fisiología , Ecocardiografía/métodos , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Estudios Retrospectivos
18.
J Cardiol ; 76(3): 251-258, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32354493

RESUMEN

BACKGROUND: Our aim was to evaluate the ability of adenosine triphosphate (ATP)-stress myocardial computed tomography perfusion (CTP) imaging to detect myocardial ischemia in the left anterior descending artery (LAD) territory, and to compare this method with coronary flow velocity reserve (CFVR) measured by transthoracic Doppler echocardiography (TTDE). METHODS: ATP-stress CTP and CFVR were performed in 50 patients with stable angina pectoris. Myocardial ischemia assessed from CTP imaging was defined as qualitative visual perfusion defects and reduced myocardial blood flow (MBF) based on quantitative assessment. A cut-off value of CFVR of 2.0 was used. RESULTS: The mean CFVR was 1.9 ± 0.6 in ischemic regions by CTP, whereas it was 2.9 ± 0.8 in non-ischemic regions (p < 0.001). CTP imaging could accurately predict CFVR <2.0 with 84.0% diagnostic accuracy (94.7% sensitivity, 77.4% specificity, 72.0% positive predictive value, and 96.0% negative predictive value). When receiver operating characteristic curve analysis of the MBF data was performed to detect CFVR <2.0, the area under the curve was 0.89, and the optimal MBF cut-off value was 1.43 mL/g/min. CONCLUSIONS: This study suggests that qualitative and quantitative assessment of ATP-stress CTP exhibits a good correlation with CFVR for evaluation of myocardial ischemia.


Asunto(s)
Vasos Coronarios/diagnóstico por imagen , Ecocardiografía Doppler/estadística & datos numéricos , Isquemia Miocárdica/diagnóstico por imagen , Imagen de Perfusión Miocárdica/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Adenosina Trifosfato , Anciano , Área Bajo la Curva , Velocidad del Flujo Sanguíneo , Circulación Coronaria/fisiología , Ecocardiografía Doppler/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/métodos , Valor Predictivo de las Pruebas , Curva ROC , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
19.
J Cardiol ; 76(3): 259-265, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32359811

RESUMEN

BACKGROUND: This study aimed to evaluate the combined diagnostic performance of coronary artery stenosis-subtended myocardial volume (Vsub) and myocardial blood flow (MBFsub) on computed tomography (CT) for detecting obstructive coronary artery disease (CAD) assessed by invasive coronary angiography (ICA) and fractional flow reserve (FFR). METHODS: Thirty-nine patients who underwent coronary CT angiography (CTA) and stress dynamic myocardial CT perfusion (CTP) prior to ICA were enrolled. Obstructive CAD was defined as severe (≥70%) or moderate (30-69%) stenosis with FFR ≤0.8 on ICA. The Vsub was semi-automatically calculated from coronary CTA data using Voronoi diagram-based myocardial segmentation. The standard CT-MBF based on the 17-segment model was calculated using dynamic stress CTP data and deconvolution analysis. The CT-MBFsub was automatically analyzed by integrating the CT-MBF and Voronoi diagram-based myocardial segmentation analyses. The diagnostic performance of combined CT-MBFsub and Vsub assessment was determined using receiver operating characteristic analysis and compared with standard CT-MBF and CT-MBFsub. RESULTS: Of 117 vessels in 39 patients, 72 vessels were suspected of significant stenosis on CTA and 33 vessels had obstructive CAD on ICA and FFR. The sensitivity and specificity for identifying obstructive CAD were 67% and 82% for standard CT-MBF, 70% and 77% for CT-MBFsub, and 85% and 82% for combined CT-MBFsub and Vsub assessment. The area under the receiver operating characteristic curve of the combined CT-MBFsub and Vsub assessment was significantly higher than those of standard CT-MBF and CT-MBFsub (0.89 vs. 0.75, 0.77; p<0.05). CONCLUSIONS: The Vsub may aid in increasing the diagnostic performance of CT-MBFsub for detecting obstructive CAD.


Asunto(s)
Angiografía por Tomografía Computarizada/estadística & datos numéricos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica/estadística & datos numéricos , Anciano , Angiografía por Tomografía Computarizada/métodos , Enfermedad de la Arteria Coronaria/fisiopatología , Estudios de Factibilidad , Femenino , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/métodos , Miocardio/patología , Valor Predictivo de las Pruebas , Curva ROC , Sensibilidad y Especificidad
20.
Int J Cardiovasc Imaging ; 36(9): 1781-1789, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32399762

RESUMEN

We aimed to evaluate the effects of four-dimensional noise reduction filtering using a similarity algorithm (4D-SF) on the image quality and hemodynamic parameter of dynamic myocardial computed tomography perfusion (CTP). Sixty-eight patients who underwent dynamic myocardial CTP for the assessment of coronary artery disease were enrolled. Dynamic CTP was performed using a 320-row CT with low tube voltage scan (80 kVp). Two different datasets of dynamic CTP were reconstructed using iterative reconstruction (IR) alone and a combination of IR and 4D-SF. Qualitative (5-grade scale) and quantitative image quality scores were assessed, and the CT-derived myocardial blood flow (CT-MBF) was quantified. These results were compared between the two different CTP images. The qualitative image quality in CTP images reconstructed with IR and 4D-SF was significantly higher than that with IR alone (noise score: 4.7 vs. 3.4, p < 0.05). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in CTP images reconstructed with IR and 4D-SF were significantly higher than those with IR alone (SNR: 20.6 vs. 9.7; CNR: 7.9 vs. 3.9, respectively; p < 0.05). There was no significant difference in mean CT-MBF between the two sets of CTP images (3.01 vs. 3.03 mL/g/min, p = 0.1081). 4D-SF showed incremental value in improving image quality in combination with IR without altering CT-MBF quantification in dynamic myocardial CTP imaging with a low tube potential.


Asunto(s)
Algoritmos , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Circulación Coronaria , Tomografía Computarizada Multidetector , Imagen de Perfusión Miocárdica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador , Anciano , Enfermedad de la Arteria Coronaria/fisiopatología , Bases de Datos Factuales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...