Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
2.
Front Cardiovasc Med ; 10: 1272944, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37795488

RESUMEN

Background: ApoB-containing lipoproteins including low-density lipoprotein cholesterol (LDL-C) are necessary for the development of atherosclerosis, and lifelong exposure to low serum levels of LDL-C have been associated with a substantial reduction of cardiovascular risk. Although plaque regression has been observed in patients with serum LDL-C less than 70-80 mg/dl on lipid-lowering therapy, an LDL-C level under which atherosclerosis cannot develop has not been established. Case presentation: In this case we describe a 60-year-old man with well-controlled diabetes mellitus and hypertension who presented to the hospital after an acute stroke likely due to an atrial myxoma discovered on imaging. A coronary computed tomography angiography scan performed in preparation for the planned surgical myxoma resection revealed an anomalous origin of the right coronary artery as well as evidence of nonobstructive coronary atherosclerosis in the right coronary and non-anomalous left coronary system. Despite not having ever been on any lipid-lowering therapy, this patient was found to have low LDL-C levels (<40 mg/dl) during this admission and on routine laboratory data collected over the prior 16 years. His family history strongly suggested heterozygous familial hypobetalipoproteinemia as a possible diagnosis. Conclusions: This case illustrates that even long-standing, very low levels of LDL-C may be insufficient to completely prevent atherosclerosis and emphasizes the importance of primordial prevention of all cardiovascular risk factors.

3.
Rheumatol Int ; 43(5): 849-858, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36894756

RESUMEN

Impaired left-ventricular (LV) and right-ventricular (RV) cardiac magnetic resonance (CMR) strain has been documented in systemic sclerosis (SSc). However, it is unknown whether the CMR strain is predictive of adverse outcomes in SSc. Therefore, we set out to investigate the prognostic value of CMR strain in SSc. Patients with SSc who underwent CMR for clinical indications between 11/2010 and 07/2020 were retrospectively studied. LV and RV strain was evaluated by feature tracking. The association between strain, late gadolinium enhancement (LGE), and survival was evaluated with time to event and Cox-regression analyses. During the study period, 42 patients with SSc (age: 57 ± 14 years, 83% female, 57% limited cutaneous SSc, SSc duration: 7 ± 8 years) underwent CMR. During the median follow-up of 3.6 years, 11 patients died (26%). Compared to surviving patients, patients who died had significantly worse LV GLS (- 8.2 ± 6.2% versus - 12.1 ± 2.9%, p = 0.03), but no difference in LV global radial, circumferential, or RV strain values. Patients within the quartile of most impaired LV GLS (≥ - 12.8%, n = 10) had worse survival when compared to patients with preserved LV GLS (< - 12.8%, n = 32, log-rank p = 0.02), which persisted after controlling for LV cardiac output, LV cardiac index, reduced LV ejection fraction, or presence of LGE. In addition, patients who had both impaired LV GLS and LGE (n = 5) had worse survival than patients with LGE or impaired GLS alone (n = 14) and compared to those without any of these features (n = 17, p = 0.003). In our retrospective cohort of patients with SSc undergoing CMR for clinical indications, LV GLS and LGE were found to be predictive of overall survival.


Asunto(s)
Medios de Contraste , Esclerodermia Sistémica , Humanos , Femenino , Adulto , Persona de Mediana Edad , Anciano , Masculino , Estudios Retrospectivos , Imagen por Resonancia Cinemagnética , Tensión Longitudinal Global , Gadolinio , Imagen por Resonancia Magnética , Función Ventricular Izquierda , Volumen Sistólico , Esclerodermia Sistémica/complicaciones , Esclerodermia Sistémica/diagnóstico por imagen , Pronóstico , Valor Predictivo de las Pruebas
6.
JACC Case Rep ; 3(2): 314-318, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34317526

RESUMEN

Two middle-aged women had evidence suggesting right ventricular hypertrophy on routine electrocardiograms. Their echocardiograms showed right ventricular thickening and cardiac magnetic resonance imaging revealed right ventricular fatty infiltration. Neither patient fulfilled the criteria for arrhythmogenic right ventricular cardiomyopathy, and both had a benign clinical course. (Level of Difficulty: Intermediate.).

7.
PLoS One ; 16(2): e0246764, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33606757

RESUMEN

BACKGROUND: Immune checkpoint inhibitors (ICIs) are highly effective in treating cancer; however, cardiotoxicity can occur, including myocarditis. Cardiac magnetic resonance (CMR) imaging is useful for evaluation of myocarditis, although it has not been well studied in ICI cardiotoxicity. METHODS: We identified patients referred for CMR evaluation of ICI cardiotoxicity from September 2015 through September 2019. We assessed structural and functional parameters, feature tracking (FT) left ventricular and atrial strain, T2- weighted ratios and quantitative late gadolinium enhancement (LGE). We also applied the Updated Lake Louise Criteria for diagnosis of myocarditis. RESULTS: Of the 20 patients referred, the median left ventricular ejection fraction (LVEF) was 52.5% ± 19.1 and 50% had a normal LVEF (≥53%). FT strain analysis revealed an average abnormal global longitudinal strain (GLS) of -9.8%± 4.2%. In patients with a normal LVEF, the average GLS remained depressed at -12.3%± 2.4%. In all patients, GLS demonstrated a significant negative correlation with LVEF (rs = -0.64, p 0.002). Sixteen patients (80%) had presence of LGE (14 non-ischemic pattern and 2 ischemic). Percent LGE did not correlate with any CMR parameters and notably did not correlate with LVEF (rs = -0.29, p = 0.22) or GLS (rs = 0.10, p = 0.67), highlighting the value of tissue characterization beyond functional assessment. Nine patients (45%) met full Updated Lake Louise Criteria and 85% met at least one criterion, suggestive of myocarditis in the correct clinical context. Thirteen patients (65%) were treated for ICI-associated myocarditis and, of these, 54% (n = 7) had recovery of LVEF to normal. There was no correlation between LVEF (p = 0.47), GLS (0.89), or % LGE (0.15) and recovery of LVEF with treatment. CONCLUSION: In patients with suspected ICI cardiotoxicity, CMR is an important diagnostic tool, even in the absence of overt left ventricular dysfunction, as abnormalities in left ventricular strain, T2 signal and LGE can identifying disease.


Asunto(s)
Cardiotoxicidad/diagnóstico por imagen , Inhibidores de Puntos de Control Inmunológico/efectos adversos , Miocarditis/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico por imagen , Anciano , Cardiotoxicidad/complicaciones , Cardiotoxicidad/diagnóstico , Medios de Contraste , Edema/diagnóstico por imagen , Femenino , Fibrosis/diagnóstico por imagen , Gadolinio , Humanos , Inflamación/diagnóstico por imagen , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Miocarditis/complicaciones , Miocarditis/patología , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda
8.
Future Cardiol ; 17(4): 585-592, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33084387

RESUMEN

The systemic or catheter-directed infusion of thrombolytics benefits patients with massive and probably submassive pulmonary embolism. However, the risk of bleeding may offset benefits in a substantial number of patients. Percutaneous mechanical thromboembolectomy is an alternative to thrombolysis in those patients with contraindications to the lytic therapy, also potentially a way to avoid systemic or catheter-directed infusion of the thrombolytic all together. The Inari FlowTriever System (Inari Medical Inc, CA, USA) is the first US FDA-cleared large-bore aspiration thrombectomy device with pulmonary embolism thrombectomy indication. This article is a review of the FlowTriever System, its clinical use, current supportive literates and future research directions.


Asunto(s)
Embolia Pulmonar , Fibrinolíticos/uso terapéutico , Hemorragia , Humanos , Embolia Pulmonar/tratamiento farmacológico , Embolia Pulmonar/cirugía , Trombectomía , Terapia Trombolítica , Resultado del Tratamiento
10.
J Magn Reson Imaging ; 49(3): 688-699, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30252987

RESUMEN

BACKGROUND: Cardiac 3D navigator-gated late gadolinium enhancement (LGE) imaging is important for assessment of left atrial fibrosis, but the image quality is often degraded due to arrhythmia. PURPOSE: To investigate a novel 3D LGE sequence with improved myocardial nulling and reduced ghosting artifacts during arrhythmia. STUDY TYPE: Prospective. POPULATION: Arrhythmia patients (n = 14). SEQUENCE: The proposed technique, REPAIRit (Regrowth Equalization Pulse for Arrhythmias in Inversion Recovery with automatic inversion time calculation), inserts a saturation pulse with a dynamic flip angle into the 3D LGE sequence to minimize arrhythmia-induced signal fluctuations. Using ShMOLLI (shortened modified Look-Locker imaging) to estimate myocardial T1 , REPAIRit automatically calculates the optimal inversion time (TI) based on Bloch equations. ASSESSMENT: REPAIRit LGE and the standard LGE were compared with simulations, phantom imaging, and patient studies. Patient images were assessed quantitatively, based on ghost-to-noise ratio (GNR), blood signal-to-noise ratio (SNRb), myocardial signal-to-noise ratio (SNRm), and blood-to-myocardium contrast-to-noise ratio (CNR), and qualitatively on a 4-point scale. Patients were subgrouped based on the presence of arrhythmia to assess the image quality difference. STATISTICAL TESTS: The two LGE sequences were compared by Student's t-test and Wilcoxon signed-rank test. The two patient-subgroups were compared using Welch's t-test and Wilcoxon rank-sum test. RESULTS: In 14 analyzed patients, REPAIRit LGE significantly lowered GNR (1.25 ± 0.41 vs. 1.42 ± 0.42, P = 0.04), reduced SNRm (1.90 ± 0.60 vs. 3.16 ± 1.66, P = 0.01), improved ghosting artifact scores (2.5 ± 0.6 vs. 2.2 ± 0.9, P = 0.03), myocardial nulling scores (2.7 ± 0.5 vs. 2.3 ± 0.7, P = 0.02), and atrial quality scores (2.8 ± 0.3 vs. 2.4 ± 0.8, P = 0.03) compared with the standard LGE. Comparing patients with arrhythmia (n = 6) to those without (n = 8) during the scan, the former had lower left ventricular (LV) myocardial T1 s (430 ± 26 msec vs. 469 ± 39 msec, P = 0.06) but similar blood T1 s (318 ± 55 msec vs. 316 ± 27 msec, P = 0.96), and significantly lower blood SNR (5.2 ± 1.8 vs. 9.2 ± 3.0, P = 0.01) and significantly worse image quality (P = 0.01 for REPAIRit and P = 0.03 for standard). DATA CONCLUSION: REPAIRit improves myocardial nulling and reduces ghosting artifacts of 3D LGE under arrhythmia. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:688-699.


Asunto(s)
Arritmias Cardíacas/diagnóstico por imagen , Técnicas de Imagen Cardíaca , Gadolinio/química , Imagen por Resonancia Magnética , Miocardio/metabolismo , Adulto , Anciano , Artefactos , Medios de Contraste/química , Femenino , Corazón/diagnóstico por imagen , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Miocardio/patología , Fantasmas de Imagen , Estudios Prospectivos , Relación Señal-Ruido
11.
Evol Med Public Health ; 2018(1): 60-66, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29588855

RESUMEN

Management of prosthetic vascular graft infections caused by Pseudomonas aeruginosa can be a significant challenge to clinicians. These infections often do not resolve with antibiotic therapy alone due to antibiotic resistance/tolerance by bacteria, poor ability of antibiotics to permeate/reduce biofilms and/or other factors. Bacteriophage OMKO1 binding to efflux pump proteins in P. aeruginosa was consistent with an evolutionary trade-off: wildtype bacteria were killed by phage whereas evolution of phage-resistance led to increased antibiotic sensitivity. However, phage clinical-use has not been demonstrated. Here, we present a case report detailing therapeutic application of phage OMKO1 to treat a chronic P. aeruginosa infection of an aortic Dacron graft with associated aorto-cutaneous fistula. Following a single application of phage OMKO1 and ceftazidime, the infection appeared to resolve with no signs of recurrence.

12.
J Magn Reson Imaging ; 47(6): 1498-1508, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29112315

RESUMEN

BACKGROUND: Cardiac dark-blood turbo spin-echo (TSE) imaging is sensitive to through-plane motion, resulting in myocardial signal reduction. PURPOSE: To propose and validate reverse double inversion-recovery (RDIR)-a dark-blood preparation with improved motion robustness for the cardiac dark-blood TSE sequence. STUDY TYPE: Prospective. POPULATION: Healthy volunteers (n = 10) and patients (n = 20). FIELD STRENGTH: 1.5T (healthy volunteers) and 3T (patients). ASSESSMENT: Compared to double inversion recovery (DIR), RDIR swaps the two inversion pulses in time and places the slice-selective 180° in late-diastole of the previous cardiac cycle to minimize slice misregistration. RDIR and DIR were performed in the same left-ventricular basal short-axis slice. Healthy subjects were imaged with two preparation slice thicknesses, 110% and 200%, while patients were imaged using a 200% slice thickness only. Images were assessed quantitatively, by measuring the myocardial signal heterogeneity and the extent of dropout, and also qualitatively on a 5-point scale. STATISTICAL TESTS: Quantitative and qualitative data were assessed with Student's t-test and Wilcoxon signed-rank test, respectively. RESULTS: In healthy subjects, RDIR with 110% slice thickness significantly reduced signal heterogeneity in both the left ventricle (LV) and right ventricle (RV) (LV: P = 0.006, RV: P < 0.0001) and the extent of RV dropout (P < 0.0001), while RDIR with 200% slice thickness significantly reduced RV signal heterogeneity (P = 0.001) and the extent of RV dropout (P = 0.0002). In patients, RDIR significantly reduced RV myocardial signal heterogeneity (0.31 vs. 0.43; P = 0.003) and the extent of RV dropout (24% vs. 46%; P = 0.0005). LV signal heterogeneity exhibited a trend towards improvement with RDIR (0.12 vs. 0.16; P = 0.06). Qualitative evaluation showed a significant improvement of LV and RV visualization in RDIR compared to DIR (LV: P = 0.04, RV: P = 0.0007) and a significantly improved overall image quality (P = 0.03). DATA CONCLUSION: RDIR TSE is less sensitive to through-plane motion, potentiating increased clinical utility for black-blood TSE. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1498-1508.


Asunto(s)
Cardiopatías/diagnóstico por imagen , Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Movimiento (Física) , Miocardio/patología , Adulto , Anciano , Algoritmos , Artefactos , Simulación por Computador , Diástole , Femenino , Voluntarios Sanos , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Control de Calidad , Reproducibilidad de los Resultados , Relación Señal-Ruido
14.
J Am Heart Assoc ; 5(1)2016 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-26746998

RESUMEN

BACKGROUND: Thoracic aortic aneurysm is usually a clinically silent disease; timely detection is largely dependent upon identification of clinical markers of thoracic aortic disease (TAD); (bicuspid aortic valve, intracranial aortic aneurysm, bovine aortic arch, or positive family history). Recently, an association of simple renal cysts (SRC) with abdominal aortic aneurysm and aortic dissection was established. The aim of our study was to evaluate the prevalence of SRC in patients with TAD in order to assess whether the presence of SRC can be used as a predictor of TAD. METHODS AND RESULTS: We evaluated the prevalence of SRC in 842 patients with TAD (64.0% males) treated at our institution from 2004 to 2013 and compared to a control group of patients (n=543; 56.2% males). Patients were divided into 4 groups: ascending aortic aneurysm (456; 54.2%); descending aortic aneurysm (86; 10.2%); type A aortic dissection (118; 14.0%); and type B aortic dissection (182; 21.6%). SRC were identified by abdominal computed tomography or magnetic resonance imaging of these patients. Prevalence of SRC is 37.5%, 57.0%, 44.1%, and 47.3% for patients with ascending aneurysm, descending aneurysm, type A dissection, and type B dissection, respectively. Prevalence of SRC in the control group was 15.3%. Prevalence of SRC was not significantly different between male and female aortic disease patients, despite reported general male predominance (2:1), which was also observed in our control group (1.7:1). CONCLUSIONS: This study establishes an increased prevalence of SRC in patients with TAD. SRC can potentially be used as a marker for timely detection of patients at risk of TAD.


Asunto(s)
Aneurisma de la Aorta Torácica/epidemiología , Disección Aórtica/epidemiología , Enfermedades Renales Quísticas/epidemiología , Adolescente , Adulto , Distribución por Edad , Anciano , Anciano de 80 o más Años , Disección Aórtica/diagnóstico , Aneurisma de la Aorta Torácica/diagnóstico , Aortografía/métodos , Connecticut/epidemiología , Femenino , Humanos , Enfermedades Renales Quísticas/diagnóstico , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Retrospectivos , Factores de Riesgo , Distribución por Sexo , Tomografía Computarizada por Rayos X , Adulto Joven
15.
JAMA Surg ; 151(2): 147-53, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26501863

RESUMEN

IMPORTANCE: Abdominal aortic aneurysms are associated with chronic inflammation within the aortic wall, and previous studies have suggested that chronic inflammation may be a consequence of a dysregulated and persistent autoimmune response. Persistent aortic remodeling after aneurysm repair could place the patient at risk for endoleak or sac rupture. OBJECTIVE: To determine whether patients with systemic inflammatory disease and large aneurysms have persistent aortic remodeling after endovascular aneurysm repair (EVAR). DESIGN, SETTING, AND PARTICIPANTS: The records of all patients who underwent EVAR between July 2002 and June 2011 at the Veterans Affairs Connecticut Healthcare System were included in this retrospective review. Patients were considered to have a systemic inflammatory disease when confirmed by a referring specialist. Post-EVAR surveillance was performed by yearly imaging. INTERVENTION: Endovascular aneurysm repair. MAIN OUTCOMES AND MEASURES: Significant endoleak, defined as endoleak and sac diameter increase of 0.5 cm or greater. RESULTS: A total of 51 of 79 patients (65%) had a systemic inflammatory disease. These patients had similar comorbid conditions compared with patients without inflammation but significantly greater numbers of major postoperative complications after EVAR (23.5% vs 3.6%; P = .02) and overall postoperative complications after EVAR (27.5% vs 7.1%; P = .03). Patients with a history of systemic inflammatory disease developed more endoleaks (45.1% vs 17.9%; P = .02) and late sac expansion (51.0% vs 21.4%; P = .01) and required more interventions (21.6% vs 3.6%; P = .03) during long-term follow-up. Systemic inflammatory disease was significantly associated with significant endoleak (odds ratio, 5.18; 95% CI, 1.56-17.16; P = .007). CONCLUSIONS AND RELEVANCE: Patients with systemic inflammatory disease are at high risk for postoperative complications, type II endoleak, sac expansion, and additional interventions after EVAR. Additional strategies for improving the efficacy of EVAR in these patients may be warranted.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Endofuga/clasificación , Endofuga/complicaciones , Procedimientos Endovasculares , Inflamación/etiología , Anciano , Femenino , Humanos , Masculino , Estudios Retrospectivos , Factores de Tiempo
17.
J Vasc Surg ; 53(5): 1386-90, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21276684

RESUMEN

A 79-year-old woman presented with a ruptured saccular thoracoabdominal aortic aneurysm involving the celiac and mesenteric artery. The patient was unfit for open surgical repair. A "chimney" procedure was performed, which involved placement of stents in the aortic side branches alongside the endograft. The patient underwent another chimney procedure 2 weeks later for a type I endoleak. Computed tomography angiography (CTA) at 1 and 6 months showed a good result with no endoleaks or graft migration. The chimney procedure provides an alternative for emergency patients unfit for open repair and has the advantage that stents can be used that are already available in most institutions.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares , Anciano , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Rotura de la Aorta/diagnóstico por imagen , Aortografía/métodos , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Arteria Celíaca/diagnóstico por imagen , Endofuga/etiología , Endofuga/cirugía , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Arterias Mesentéricas/diagnóstico por imagen , Diseño de Prótesis , Reoperación , Stents , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
18.
J Vasc Access ; 11(4): 342-5, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20853251

RESUMEN

PURPOSE: The VenaTrac™ is designed for exchange and primary placement of chronic tunneled hemodialysis catheters over a wire. It occludes both lumens of the catheter for the purpose of reducing the risk of air embolism and blood loss. The purpose of this paper is to report our experience with the use of this device. METHODS: A retrospective review of chronic hemodialysis dialysis catheters exchanges over a 30-month period was performed. Two hundred and ninety-seven over-the-wire catheter exchanges and 47 primary placements using the VenaTrac™ device were reviewed. In addition, 430 over-the-wire catheter exchanges without the use of the VenaTrac™ were reviewed. RESULTS: No insertional complications or air embolism occurred when using the VenaTrac™. Symptomatic air embolism was documented in 5 out of 430 catheter exchanges performed without the use of VenaTrac™ (1.2%). CONCLUSIONS: VenaTrac™ over-the-wire insertion device demonstrated safe and reliable use with no incidence of air embolism.


Asunto(s)
Cateterismo Venoso Central/instrumentación , Catéteres de Permanencia , Diálisis Renal , Cateterismo Venoso Central/efectos adversos , Connecticut , Remoción de Dispositivos , Embolia Aérea/etiología , Embolia Aérea/prevención & control , Diseño de Equipo , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
19.
J Comput Assist Tomogr ; 34(1): 52-7, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20118722

RESUMEN

OBJECTIVE: This study assesses if the arm of contrast infusion influences attenuation of the main pulmonary artery in computed tomography (CT) angiograms to evaluate for pulmonary emboli. METHODS: Four hundred seven consecutive CT angiograms performed to exclude pulmonary emboli were reviewed. Patient characteristics, study details, and interpretation results were collected. After exclusion criteria, 100 studies from each scanner (4, 16, and 64 slice) remained. A reader, blinded to injection side, measured the attenuation of the main pulmonary artery. RESULTS: The average attenuation in the main pulmonary artery was similar if infused through the right (275.4 HU) or left (275.0 HU) arm when controlling for confounders with a multiple regression analysis (P = 0.82). There was no statistical difference (P > 0.05) in the number of scans with attenuation less than 250 (45.9% right, 42.9% left), 200 (25.3% right, 29.2% left), or 150 HU (11.6% right, 12.3% left) and interpreted as indeterminate (1.4% right, 3.9% left) or nondiagnostic (2.7% right, 2.6% left). CONCLUSIONS: Main pulmonary artery attenuation is independent of the arm of infusion when evaluating mean attenuation, attenuation beneath 250, 200, or 150 HU, or indeterminate or nondiagnostic interpretations for patients undergoing CT angiograms of the chest to rule out pulmonary emboli.


Asunto(s)
Brazo/irrigación sanguínea , Medios de Contraste , Yohexol , Arteria Pulmonar/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Estudios de Cohortes , Femenino , Humanos , Infusiones Intravenosas , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
20.
Can Assoc Radiol J ; 61(4): 223-9, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20083369

RESUMEN

PURPOSE: To determine if valuable information could be obtained from abdominal computed tomography (CT) performed before insertion of an inferior vena cava (IVC) filter. MATERIALS AND METHODS: A retrospective review was performed on IVC filter insertions with a CT performed before the procedure. Cavagram and CT were compared for renal vein and IVC anatomy, the diameter of the IVC, and the prevalence of iliocaval thrombus. Correlations were assessed among 3 reference standards for measuring the IVC at cavography. RESULTS: The mean IVC diameter was 23.0 mm on CT. On cavagram the mean IVC diameter was assessed by using 3 reference standards: 20.7 mm, with the catheter tip as a reference; 26.9 mm, with a radiopaque ruler; and 23.4 mm, by using a lumbar vertebral body. There was good correlation among the 3 measures of IVC diameter (Pearson's r = 0.75, P < .0001) but moderate correlation with CT (r = 0.36-0.56, P < .001). The sensitivity of cavagram for detecting retroaortic and circumaortic renal veins was 40% and 0%, respectively. Nineteen accessory renal veins (12.8%) were not seen by cavagram. Thirteen patients (8.8%) had iliocaval thrombus on cavagram, of which 12 (92.3%) were not previously detected by CT. CONCLUSIONS: CT is more sensitive than cavagram for detection of renal vein variants and the level of the lowest renal vein. Therefore, if available, the CT should be reviewed before placement of an IVC filter to optimize positioning. Cavagram remains the criterion standard for detection of iliocaval thrombosis and is necessary before IVC filter insertion.


Asunto(s)
Cuidados Preoperatorios/métodos , Tomografía Computarizada por Rayos X/métodos , Filtros de Vena Cava , Vena Cava Inferior/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Estándares de Referencia , Venas Renales/diagnóstico por imagen , Estudios Retrospectivos , Sensibilidad y Especificidad , Ácidos Triyodobenzoicos , Trombosis de la Vena/diagnóstico , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...