Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 475
Filtrar
1.
Int J Cardiol ; : 132317, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38986745

RESUMEN

AIM: The aims of this study were: i) to report the prevalence of low-risk patients with degenerative mitral regurgitation (DMR) undergoing mitral transcatheter edge-to-edge repair (M-TEER) in a real-world setting; ii) to evaluate the prognostic significance of EuroSCORE II; iii) to determine whether an optimal TEER provides a mortality benefit regardless of EuroSCORE-II. METHODS: We analyzed data from the GIOTTO registry that enrolled patients undergoing M-TEER in Italy. We included only patients with DMR. Two groups were defined: patients with EuroSCORE<4% and with EuroSCORE≥4%. A further stratification according to variables included in the EuroSCORE-II was made. Interaction between EuroSCORE-II and optimal procedural success was evaluated. Outcome of interest was all-cause death at 2-year. RESULTS: Among 1659 patients prospectively enrolled in the GIOTTO registry, 657 had DMR, 364 with an EuroSCORE<4% (53%) and 311 with an EuroSCORE≥4% (47%). Patients with lower EuroSCORE were older with less comorbidities. All-cause mortality was higher in patients with EuroSCORE≥ vs <4%. EuroSCORE II ≥ 4% was independently associated with an increased risk of mortality (HR 2.36, 95%CI 1.28-4.38, p = 0.007). Among variables included in the EuroSCORE-II, Left Ventricular Ejection Fraction<35% and systolic Pulmonary Artery Pressure ≥ 50mmhg were independent predictors of clinical outcome. Two-year all-cause death was higher in patients without optimal MR reduction regardless of the calculated surgical risk (p for interaction 0.3). CONCLUSION: More than half of patients with DMR undergoing TEER had a Euroscore<4% with a median age of 81. An optimally successful TEER was associated with a lower mortality regardless of EuroSCORE.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38988147

RESUMEN

BACKGROUND: In the elderly people with unprotected left main distal bifurcation lesions (ULMD), percutaneous coronary intervention (PCI) is often selected as first choice treatment strategy because of perioperative high risk of coronary artery bypass graft surgery due to their large number of comorbidities. Also, some recent papers reported that geriatric nutritional risk index (GNRI) is also strongly associated with clinical outcomes after interventional procedures in elderly patients. OBJECTIVES: We assessed clinical outcomes after PCI for ULMD and the impact of GNRI in elderly patients. METHODS: We identified 669 non dialysis patients treated with current generation drug-eluting stent for ULMD from MITO registry. We divided the patients to the following 2 groups; elderly group (n = 240, age ≥75) and young group (n = 429, age <75). Additionally, we could calculate GNRI and divided elderly group into 2 group based on the median value of the GNRI. The primary endpoint was all-cause mortality. RESULTS: All-cause mortality was significantly higher in elderly group [adjusted hazard ratio (HR) 2.37; 95% confidence interval (CI), 1.40-4.02; p = 0.001]. All-cause mortality was significantly higher in low GNRI elderly group compared to other 2 groups (Adjusted HR of elderly with low GNRI: 3.56, 95%CI (1.77-7.14), p < 0.001). Cardiovascular mortality was comparable between two groups. TLR rate was significantly lower in elderly group (adjusted HR 0.57; 95% CI, 0.34-0.97; p = 0.035). CONCLUSIONS: The elderly had higher all-cause mortality after PCI for ULMD compared to young people. Especially, the elderly with low GNRI were extremely associated with poorer outcomes.

3.
J Am Heart Assoc ; 13(14): e033125, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-38979804

RESUMEN

BACKGROUND: Mitral regurgitation (MR) is frequent in patients with aortic stenosis (AS). Although primary MR is an established negative prognostic factor, whether different mechanisms of MR have different effects on outcome is currently unknown. The aim of this study was to evaluate the impact of the MR mechanism in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: This is a retrospective observational study of patients who underwent TAVR for severe aortic stenosis in a high-volume tertiary care center. Echocardiographic comprehensive MR assessment was performed at baseline and within 3 months post TAVR. The study population was divided into 4 groups according to MR mechanism: Group I: fibro-calcific leaflet degeneration; Group II: prolapse/flail; Group III: ventricular secondary MR (functional MR); and Group IV: atrial functional MR. The study end point was a combination of death from cardiovascular cause and heart failure-related hospitalization. The study population included 427 patients (mean age 81.7±6.5 years; 71% primary MR; 62% ≥moderate MR). At 3-year follow-up, survival free from the composite end point significantly differs according to MR mechanism: it was higher in group IV (atrial functional MR, 96.6%) compared with group I (80.4%, P=0.002) and group II patients (60.7%, P=0.001), and group III (84.8%, P=0.037); patients with MR due to leaflet prolapse showed poorer prognosis compared with patients with functional MR (group III, P=0.023 and group IV, P=0.001) and with group I (P=0.040). Overall, severe MR after TAVR identified patients with poorer prognosis and was significantly more frequent in group II (46.4%, P=0.001). CONCLUSIONS: In patients undergoing TAVR, preprocedural identification of MR mechanism and mechanism provides prognostic insights.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia de la Válvula Mitral , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Estudios Retrospectivos , Anciano de 80 o más Años , Anciano , Resultado del Tratamiento , Ecocardiografía , Factores de Riesgo , Factores de Tiempo , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología
4.
Can J Cardiol ; 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38969097

RESUMEN

Mitral valve-in-ring procedure can be an alternative to surgical valve replacement. Malposition or residual mitral regurgitation and need for a second transcatheter valve is more common in mitral valve-in-ring than in valve-in-valve procedure. This case reveals how the implantation of a second prosthesis was able to fix a significant residual mitral regurgitation due to mitral ring detachment, "closing" the free flow cage of the first prosthesis and avoiding mitral regurgitation through the ring detachment.

5.
Am Heart J ; 275: 128-137, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38838970

RESUMEN

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, P = .33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 P = .46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, P = .04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, P = .02), reduced SVi (34.2 vs 38 mL/m2, P < .01) and transaortic flow rate (190.6 vs 211 mL/s, P < .01). At predischarge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, P < .01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, P = .03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs 44 IQR 35-59 in those without, P = .02)). No evidence of a significant impact of PPM on overall (P = .71) and CV (P = .70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, P = .03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, P < .001) and LVOT diameter (OR 0.79, 0.65-0.95, P = .01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.

6.
Eur Heart J ; 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38888906

RESUMEN

Ventricular septal defects are a rare complication after acute myocardial infarction with a mortality close to 100% if left untreated. However, even surgical or interventional closure is associated with a very high mortality and currently no randomized controlled trials are available addressing the optimal treatment strategy of this disease. This state-of-the-art review and clinical consensus statement will outline the diagnosis, hemodynamic consequences and treatment strategies of ventricular septal defects complicating acute myocardial infarction with a focus on current available evidence and a focus on major research questions to fill the gap in evidence.

7.
Lancet ; 403(10445): 2695-2708, 2024 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-38795719

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
8.
J Am Heart Assoc ; 13(10): e033605, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38742523

RESUMEN

BACKGROUND: Minimally invasive mitral valve repair has a favorable risk-benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge-to-edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). METHODS AND RESULTS: We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long-term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P=0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P=0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no (P=0.558) patients. Clinical follow-up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P>0.05). Propensity score-adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09-0.81]; P=0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P>0.05). CONCLUSIONS: In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Sistema de Registros , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Masculino , Femenino , Anciano , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Italia/epidemiología , Anciano de 80 o más Años , Readmisión del Paciente/estadística & datos numéricos , Insuficiencia del Tratamiento , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral/instrumentación , Anuloplastia de la Válvula Mitral/efectos adversos , Resultado del Tratamiento , Factores de Tiempo , Factores de Riesgo , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía
9.
J Cardiovasc Dev Dis ; 11(5)2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38786975

RESUMEN

Mitral stenosis (MS) poses significant challenges in diagnosis and management due to its varied etiologies, such as rheumatic mitral stenosis (RMS) and degenerative mitral stenosis (DMS). While rheumatic fever-induced RMS has declined in prevalence, DMS is rising with aging populations and comorbidities. Starting from a complex clinical case of DMS, the aim of this paper is to review the literature on mitral stenosis by analyzing the available tools and the differences in terms of diagnosis and treatment for rheumatic and degenerative stenosis. Emerging transcatheter techniques, such as transcatheter mitral valve replacement (TMVR) and lithotripsy-facilitated percutaneous mitral commissurotomy (PMC), represent promising alternatives for DMS patients deemed unfit for surgery. In particular, intravascular lithotripsy (IVL) has shown potential in facilitating percutaneous interventions by fracturing calcific deposits and enabling subsequent interventions. However, larger prospective studies are warranted to validate these findings and establish IVL's role in DMS management. To further enhance this technique, research could focus on investigating the long-term outcomes and durability of mitral lithotripsy, as well as exploring its potential in combination with PMC or TMVR.

10.
Artículo en Inglés | MEDLINE | ID: mdl-38749449

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: To identify the incidence, predictors, and clinical outcomes of PVR following TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with severe Sievers type 1 BAV stenosis undergoing TAVR with current generation transcatheter heart valves (THVs) in 24 international centres were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAE), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%): mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were larger virtual raphe ring (VRR) perimeter (ORadj 1.07, 95% CI 1.02-1.13), severe annular or left ventricular outflow tract (LVOT) calcification (ORadj 5.21, 95% CI 1.45-18.77), self-expanding valve (ORadj 9.01, 95% CI 2.09-38.86), and intentional supra-annular THV positioning (ORadj 3.31, 95% CI 1.04-10.54). At a median follow-up of 1.3 [IQR 0.5-2.4] years, moderate or severe PVR was associated with an increased risk of MAE (HRadj 2.52, 95% CI 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAE during follow-up.

11.
G Ital Cardiol (Rome) ; 25(5): 295-299, 2024 May.
Artículo en Italiano | MEDLINE | ID: mdl-38639118

RESUMEN

Patent foramen ovale (PFO) is a remnant of normal fetal anatomy which may persist into adulthood, mostly asymptomatic. In some adults, PFO may result in a potential for shunting venous thromboembolism to the arterial circulation; less frequently it can cause interatrial, right-to-left shunting of deoxygenated blood. The pathogenesis of several medical conditions is related to the presence of PFO. Some randomized clinical trials have shown evidence of benefit for device closure as compared with medical therapy in patients with cryptogenic stroke. The literature reported several cases of carbon dioxide embolism during general laparoscopic surgery and sometimes stroke after laparoscopic or neurosurgery but there are neither prospective studies addressing these issues, nor randomized clinical trials assessing the effectiveness of pharmacotherapy or interventional procedures at decreasing risk. The European position paper suggests routine monitoring in non-cardiac surgery of patients with a PFO and no actual indications for closure. This article aims to further stratify the risk of periprocedural stroke and paradoxical embolism in this category of patients.


Asunto(s)
Embolia Paradójica , Foramen Oval Permeable , Accidente Cerebrovascular , Adulto , Humanos , Embolia Paradójica/etiología , Embolia Paradójica/prevención & control , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/cirugía , Estudios Prospectivos , Prevención Secundaria/métodos , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/complicaciones , Resultado del Tratamiento
12.
J Invasive Cardiol ; 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38598251

RESUMEN

OBJECTIVES: Transcatheter edge-to-edge repair (TEER) has become an established minimally invasive treatment for significant mitral regurgitation. Ongoing refinements and the availability of different clipping devices have expanded the indications for and effectiveness of TEER, but comprehensive comparative data on this issue are lacking. In this study, we compared NT, NTr, and XTr MitraClip devices (Abbot) for TEER. METHODS: Details on patient, imaging, and procedural details, as well as short- and long-term outcomes, were sought from a national prospective clinical registry on TEER with MitraClip. The primary outcome of interest was discharge after procedural success without major clinical complications. RESULTS: A total of 2236 patients were included, 1228 (54.9%) in whom NT implantation only was attempted, 233 (10.4%) in whom NTr but not XTr implantation was attempted, and 775 (34.7%) in whom XTr implantation was attempted. Clinical and imaging features differed substantially across the groups, reflecting expanding indications with NTr and XTr devices. In-hospital outcomes were largely similar among the 3 groups, including death. Long-term unadjusted estimates of effect showed significant differences in several outcomes, including death, rehospitalization, and their composite, which demonstrated that NT was associated with more unfavorable outcomes compared with the other devices (all P less than .05). However, most differences depended on baseline features, as adjusted analysis showed no significant differences for early as well as long-term outcomes, including long-term death, rehospitalization, and their composite (all P greater than .05). CONCLUSIONS: New-generation MitraClip devices are associated with favorable procedural and clinical outcomes, despite being used in patients with more adverse features, when compared with patients treated with previous devices.

13.
Can J Cardiol ; 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38492735

RESUMEN

BACKGROUND: In patients with atrial fibrillation (AF) on vitamin K antagonist (VKA) therapy and therapeutic international normalized ratio (INR) range, the incidence of cardiac thromboembolism is not negligible, and the subgroup of patients who have a mechanical prosthetic mitral valve (PMV) has the highest risk. We aimed to assess the long-term effects of left atrial appendage closure (LAAC) in AF patients with a mechanical PMV who experienced a failure of VKA therapy. METHODS: In this retrospective, multicentre study, patients underwent LAAC because of thrombotic events including transient ischemic attack and/or stroke, systemic embolism, and evidence of left atrial appendage thrombosis and/or sludge, despite VKA therapy, were enrolled. Patients with a mechanical PMV were included and compared with those affected by nonvalvular AF. The primary endpoint was the composite of all-cause death, major cardiovascular events, and major bleedings at follow-up. The feasibility and safety of LAAC also were assessed. RESULTS: A total of 55 patients (42% female; mean age, 70 ± 9 years), including 12 with a mechanical PMV, were enrolled. The most-frequent indication to LAAC (71%) was LAA thrombosis or sludge. Procedural success was achieved in 96% of overall cases, and in 100% of patients with a PMV. In 35 patients, a cerebral protection device was used. During a median follow-up of 6.1 ± 4.3 years, 4 patients with a PMV, and 20 patients without a PMV, reported adverse events (hazard ratio 0.73 [95% confidence interval 0.25-2.16, P = 0.564]). CONCLUSIONS: LAAC seems to be a valuable alternative in patients with AF who have a mechanical PMV, with failure of VKA therapy. This off-label, real-world clinical practice indication deserves validation in further studies.

14.
JACC Cardiovasc Interv ; 17(6): 742-752, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38538170

RESUMEN

BACKGROUND: Coronary obstruction (CO) is a potentially life-threatening complication of transcatheter aortic valve replacement (TAVR). Chimney stenting or leaflet laceration with transcatheter electrosurgery (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction [BASILICA]) are 2 techniques developed to prevent CO. OBJECTIVES: The aim of the present study was to compare periprocedural and 1-year outcomes of chimney and BASILICA in TAVR patients at high risk of CO. METHODS: This multicenter observational registry enrolled consecutive TAVR patients at high risk of CO, undergoing either preventive chimney stenting or BASILICA. Clinical success was defined as successful performance of the chimney or BASILICA technique without clinically relevant ostial CO. The primary endpoint was major adverse cardiovascular events, a composite of death, myocardial infarction, stroke, or unplanned target lesion coronary revascularization at 1 year. RESULTS: A total of 168 patients were included: 71 (42.3%) received chimney stenting, and 97 (57.7%) underwent BASILICA. Patients undergoing BASILICA had higher preprocedural risk of CO, as indicated by lower sinotubular junction height (18.2 ± 4.8 mm vs 14.8 ± 3.4 mm; P < 0.001) and diameter (28.2 ± 4.5 vs 26.8 ± 3.4; P = 0.029). Rates of periprocedural complications were similar between the 2 groups. Clinical success was 97.2% and 96.9% in chimney and BASILICA, respectively (P = 0.92). At 1-year follow-up, the cumulative incidence of major adverse cardiovascular events was 18.7% (95% CI: 11%-30.6%) in the chimney group and 19.9% (95% CI: 12.1%-31.5%) in the BASILICA group (log-rank P = 0.848), whereas chimney was associated with a numerically higher cardiovascular mortality than BASILICA (6.7% vs 1.3%; log-rank P = 0.168). CONCLUSIONS: Chimney stenting and BASILICA effectively prevent TAVR-induced acute CO. Both techniques seem to have comparable acceptable periprocedural and 1-year outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Oclusión Coronaria , Prótesis Valvulares Cardíacas , Laceraciones , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Laceraciones/complicaciones , Laceraciones/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Oclusión Coronaria/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Diseño de Prótesis
15.
Int J Cardiol ; 402: 131859, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38360100

RESUMEN

BACKGROUND: Ischemia with non-obstructive coronary artery (INOCA) disease is being progressively acknowledged as one of the pathophysiological mechanisms of chronic coronary syndrome (CCS) in an increasingly wide range of clinical pictures. Although the research has already begun to move towards a defined diagnostic pathway and a specific medical therapy for this disease, at present it remains a clinical challenge, especially if not thoroughly investigated. METHODS AND RESULTS: The INOCA IT Multicenter Registry RF-2019-12369486 is a prospective, multicentric, non-randomized, single-arm, open label clinical study which aims to evaluate the efficacy of a stratified diagnostic and therapeutic approach on adverse events prevention and symptom relief in Italian patients with INOCA disease. The study population includes patients with a clinical presentation of CCS for angina and/or positive stress test for myocardial ischemia and evidence of non-obstructive coronary artery disease (CAD) at coronary angiography. In these patients a complete invasive coronary physiology assessment is performed with the guidewire-based measurement of coronary flow reserve (CFR) and index of microvascular resistance (IMR), followed by acetylcholine (ACh) spasm provocation test. On the basis of the results of coronary function testing, patients are stratified into different INOCA endotypes (coronary microvascular disease, vasospastic angina, microvascular spasm, non-cardiac chest pain) and given a tailored medical therapy in accordance with the latest scientific evidence. At one year follow-up the impact of such a target therapy on angina class and quality of life, as well as on cardiovascular adverse events (hospitalization and coronary revascularization) is evaluated. CONCLUSIONS: The INOCA-IT Multicenter Registry will inform clinicians on sex-specific prevalence of INOCA in Italy and will show the impact of a stratified diagnostic and therapeutic approach on symptoms burden and prognosis of INOCA patients.


Asunto(s)
Enfermedad de la Arteria Coronaria , Angina Microvascular , Masculino , Femenino , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Calidad de Vida , Estudios Prospectivos , Isquemia , Sistema de Registros , Espasmo
16.
Struct Heart ; 8(1): 100226, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38283573

RESUMEN

Background: The CONtrolled delivery For ImproveD outcomEs with cliNiCal Evidence registry was initiated to characterize the clinical safety and device performance from experienced transcatheter aortic valve implantation (TAVI) centers in Europe and Australia that use the Portico valve to treat patients with severe aortic stenosis. We herein report for the first time the valve performance at 30-day across all implanted valve sizes and the 1-year survival from this registry. Methods: This was a prospective, multicenter, single-arm observational clinical investigation of patients clinically indicated for implantation of a Portico valve in experienced TAVI centers. Patients were treated with a commercially available valve (size 23, 25, 27, or 29 mm) using either the first-generation delivery system (DS) (n = 501) or the second-generation (FlexNav) DS (n = 500). Adverse events were adjudicated by an independent clinical events committee according to Valve Academic Research Consortium-2 criteria. Echocardiographic outcomes were assessed at 30 days by an independent core laboratory, and a survival check was performed at 1 year. Results: We enrolled 1001 patients (82.0 years, 62.5% female, 63.7% New York Heart Association functional class III/IV at baseline) from 27 clinical sites in 8 countries across Europe and one site in Australia. Implantation of a single valve was successful in 97.5% of subjects. Valve hemodynamics at 30 days were substantially improved relative to baseline, with large aortic valve areas and low mean gradients across all implanted valve sizes (aortic valve areas were 1.7 ± 0.4, 1.7 ± 0.5, 1.8 ± 0.5, and 2.0 ± 0.5 cm2, and mean gradients were 7.0 ± 2.7, 7.5 ± 4.7, 7.3 ± 3.3, and 6.4 ± 3.3 mmHg for 23, 25, 27, and 29 mm valve sizes, respectively). Across all implanted valve sizes, most patients (77.1%) had no patient-prosthesis mismatch. Death from any cause within 1 year occurred in 13.7% of the patients in the first-generation DS group as compared with 11.0% in the second-generation DS group (p = 0.2). Conclusions: The Portico valve demonstrated excellent hemodynamic performance across all valve sizes in a large cohort of subjects implanted in experienced TAVI centers. One-year survival rates were favorable when using both the first-generation and second-generation (FlexNav) DSs in this high-risk cohort. ClinicalTrialsgov Identifier: NCT03752866.

17.
J Cardiothorac Vasc Anesth ; 38(4): 911-917, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38281824

RESUMEN

OBJECTIVES: Caval valve implantation (CAVI) represents a minimally invasive strategy for managing severe tricuspid regurgitation in high-risk patients unsuitable for surgical or transcatheter tricuspid valve implantation. This case series aimed to assess the anesthesia management challenges and outcomes associated with this procedure, seeking to generate insights that can inform and refine anesthesia protocols. DESIGN: A case series. SETTING: At a cardiac catheterization laboratory of a teaching hospital. PARTICIPANTS: Eight patients undergoing CAVI with the Tricvalve system INTERVENTIONS: The anesthetic protocol included preprocedural planning, fast-track general anesthesia, and postprocedural debriefing. Intraoperative management involved anesthesia depth monitoring, real-time guidance via transesophageal echocardiography, and hemodynamic stability maintenance. Postoperative analgesia involved preemptive intravenous paracetamol and morphine as needed. MEASUREMENTS AND MAIN RESULTS: No anesthesia-related or implantation-related complications were observed, with a mean procedure duration of 112 ± 44 minutes. The median hospital stay was 4 days, and only 1 patient required brief intensive care unit monitoring. Postoperative right shoulder pain was reported by half of the patients, and was managed with morphine bolus administration (average dose 4.75 ± 3.6 mg). All patients had the device correctly positioned, as confirmed by postoperative transthoracic echocardiograms. None of the patients required outpatient analgesic therapy upon discharge. CONCLUSIONS: The authors' study demonstrated the potential of TricValve implantation in effectively managing severe tricuspid regurgitation with no procedure-related complications and a 100% survival rate. A collaborative, interdisciplinary approach and targeted anesthesia management proved crucial for this success. Postoperative shoulder pain emerged as a frequent complication, whose pathogenesis is still not clear, and successfully was managed using targeted analgesic therapy.


Asunto(s)
Anestésicos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Tricúspide/cirugía , Dolor de Hombro , Anestesia General/métodos , Analgésicos , Derivados de la Morfina , Resultado del Tratamiento , Cateterismo Cardíaco/métodos
18.
J Clin Med ; 13(2)2024 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-38276125

RESUMEN

Catheter-based revascularization procedures were developed as an alternative to systemic thrombolysis for patients with intermediate-high- and high-risk pulmonary embolisms. USAT IH-PE is a retrospective and prospective multicenter registry of such patients treated with ultrasound-facilitated, catheter-directed thrombolysis, whose preliminary results are presented in this study. The primary endpoint was the incidence of pulmonary hypertension (PH) at follow-up. Secondary endpoints were short- and mid-term changes in the echocardiographic parameters of right ventricle (RV) function, in-hospital and all-cause mortality, and procedure-related bleeding events. Between March 2018 and July 2023, 102 patients were included. The majority were at intermediate-high-risk PE (86%), were mostly female (57%), and had a mean age of 63.7 ± 14.5 years, and 28.4% had active cancer. Echocardiographic follow-up was available for 70 patients, and in only one, the diagnosis of PH was confirmed by right heart catheterization, resulting in an incidence of 1.43% (CI 95%, 0.036-7.7). RV echocardiographic parameters improved both at 24 h and at follow-up. In-hospital mortality was 3.9% (CI 95%, 1.08-9.74), while all-cause mortality was 11% (CI 95%, 5.4-19.2). Only 12% had bleeding complications, of whom 4.9% were BARC ≥ 3. Preliminary results from the USAT IH-PE registry showed a low incidence of PH, improvement in RV function, and a safe profile.

19.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37957842

RESUMEN

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Dilatación , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Diseño de Prótesis
20.
Heart ; 110(4): 271-280, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-37879880

RESUMEN

OBJECTIVES: To ascertain whether invasive assessment of coronary physiology soon after recanalisation of the culprit artery by primary percutaneous coronary intervention is associated with the development of microvascular obstruction by cardiac magnetic resonance in patients with ST-segment elevation myocardial infarction (STEMI). METHODS: Between November 2020 and December 2021, 102 consecutive patients were prospectively enrolled in five tertiary centres in Italy. Coronary flow reserve (CFR) and index of microvascular resistance (IMR) were measured in the culprit vessel soon after successful primary percutaneous coronary intervention. Optimal cut-off points of IMR and CFR to predict the presence of microvascular obstruction were estimated, stratifying the population accordingly in four groups. A comparison with previously proposed stratification models was carried out. RESULTS: IMR>31 units and CFR≤1.25 yielded the best accuracy. Patients with IMR>31 and CFR≤1.25 exhibited higher microvascular obstruction prevalence (83% vs 38%, p<0.001) and lower left ventricular ejection fraction (45±9% vs 52±9%, p=0.043) compared with those with IMR≤31 and CFR>1.25, and lower left ventricular ejection fraction compared with patients with CFR≤1.25 and IMR≤31 (45±9% vs 54±7%, p=0.025). Infarct size and area at risk were larger in the former, compared with other groups. CONCLUSIONS: IMR and CFR are associated with the presence of microvascular obstruction in STEMI. Patients with an IMR>31 units and a CFR≤1.25 have higher prevalence of microvascular obstruction, lower left ventricular ejection fraction, larger infarct size and area at risk. TRIAL REGISTRATION NUMBER: NCT04677257.


Asunto(s)
Infarto del Miocardio , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Circulación Coronaria , Imagen por Resonancia Magnética , Microcirculación/fisiología , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico , Volumen Sistólico , Resultado del Tratamiento , Resistencia Vascular , Función Ventricular Izquierda/fisiología , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...