Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Anal Sci ; 22(12): 1525-9, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17159310

RESUMEN

Porous zirconia particles are very robust material and have received considerable attention as a stationary phase support for HPLC. We prepared cellulose dimethylphenylcarbamate-bonded carbon-clad zirconia (CDMPCCZ) as a chiral stationary phase (CSP) for separation of enantiomers of a set of 14 racemic compounds in normal phase (NP) and reversed-phase (RP) liquid chromatography. Retention and enantioselectivity on CDMPCCZ were compared to those on CDMPC-coated zirconia (CDMPCZ) to see how the change in immobilization method of the chiral selector affects the retention and chiral selectivity. In NPLC, retention was longer and the number of resolved racemates was smaller on CDMPCCZ than on CDMPCZ. However, chiral selectivity factors for some resolved racemates were better on CDMPCCZ than on CDMPCZ. The longer retention on CDMPCCZ is likely due to strong, non-chiral discriminating interactions with the carbon layer on CDMPCZ. In RPLC only two racemates were resolved on CDMPCCZ, but retention times were shorter than, and resolutions were comparable to, those in NPLC, indicating a potential for improving chromatographic performance of the CDMPCCZ column in RPLC with optimized column preparation and separation conditions.

2.
Ann Chim ; 96(5-6): 253-7, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16856754

RESUMEN

Low-impact ionization sources like electrospray ionization (ESI) and matrix-assisted, laser desorption/ionization (MALDI) equipped with time-of-flight (TOF) mass analyzers provide intact protein analysis over a very wide molar mass range. ESI/TOFMS provides also indications on the higher-order structure of intact proteins and non-covalent protein complexes. However, direct analysis of intact proteins mixtures in real samples shows limited success, mainly because spectra become very complex to interpret. This is also due to sample contaminants, and to the mechanism of competitive ionization in ESI or MALDI. Rapid and efficient sample clean-up and separation methods can significantly enhance the power of TOFMS for intact protein analysis. However, if protein native conditions want to be maintained, the methods should affect neither the three-dimensional structure nor the non-covalent chemistry of the proteins. Reversed-phase (RP) HPLC, size-exclusion chromatography (SEC), and capillary zone electrophoresis (CZE) are on-line or off-line coupled to ESI/TOFMS or MALDI/TOFMS. In fact, these separation methods often show limitations when applied to the analysis of native proteins. Organic modifiers and saline buffers are required in the case of RP HPLC or CZE. They can induce protein degradation or affect ionization when MS is performed after separation. High voltages used in CZE can contribute to alter proteins from their native form. In the case of high molar mass proteins, SEC is scarcely selective, and barely able to detect protein aggregates. Sample entanglement/adsorption on the stationary phase can also occur.


Asunto(s)
Fraccionamiento de Campo-Flujo/métodos , Proteínas/aislamiento & purificación , Cromatografía en Gel/instrumentación , Cromatografía en Gel/métodos , Cromatografía Líquida de Alta Presión/instrumentación , Cromatografía Líquida de Alta Presión/métodos , Electroforesis Capilar/instrumentación , Electroforesis Capilar/métodos , Fraccionamiento de Campo-Flujo/instrumentación , Proteínas/química , Espectrometría de Masa por Ionización de Electrospray/instrumentación , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/instrumentación , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...