RESUMEN
Background: The most common cause of preventable death after injury is haemorrhage. Resuscitative endovascular balloon occlusion of the aorta is intended to provide earlier, temporary haemorrhage control, to facilitate transfer to an operating theatre or interventional radiology suite for definitive haemostasis. Objective: To compare standard care plus resuscitative endovascular balloon occlusion of the aorta versus standard care in patients with exsanguinating haemorrhage in the emergency department. Design: Pragmatic, multicentre, Bayesian, group-sequential, registry-enabled, open-label, parallel-group randomised controlled trial to determine the clinical and cost-effectiveness of standard care plus resuscitative endovascular balloon occlusion of the aorta, compared to standard care alone. Setting: United Kingdom Major Trauma Centres. Participants: Trauma patients aged 16 years or older with confirmed or suspected life-threatening torso haemorrhage deemed amenable to adjunctive treatment with resuscitative endovascular balloon occlusion of the aorta. Interventions: Participants were randomly assigned 1 : 1 to: standard care, as expected in a major trauma centre standard care plus resuscitative endovascular balloon occlusion of the aorta. Main outcome measures: Primary: Mortality at 90 days. Secondary: Mortality at 6 months, while in hospital, and within 24, 6 and 3 hours; need for haemorrhage control procedures, time to commencement of haemorrhage procedure, complications, length of stay (hospital and intensive care unit-free days), blood product use. Health economic: Expected United Kingdom National Health Service perspective costs, life-years and quality-adjusted life-years, modelled over a lifetime horizon. Data sources: Case report forms, Trauma Audit and Research Network registry, NHS Digital (Hospital Episode Statistics and Office of National Statistics data). Results: Ninety patients were enrolled: 46 were randomised to standard care plus resuscitative endovascular balloon occlusion of the aorta and 44 to standard care. Mortality at 90 days was higher in the standard care plus resuscitative endovascular balloon occlusion of the aorta group (54%) compared to the standard care group (42%). The odds ratio was 1.58 (95% credible interval 0.72 to 3.52). The posterior probability of an odds ratio > 1 (indicating increased odds of death with resuscitative endovascular balloon occlusion of the aorta) was 86.9%. The overall effect did not change when an enthusiastic prior was used or when the estimate was adjusted for baseline characteristics. For the secondary outcomes (3, 6 and 24 hours mortality), the posterior probability that standard care plus resuscitative endovascular balloon occlusion of the aorta was harmful was higher than for the primary outcome. Additional analyses to account for intercurrent events did not change the direction of the estimate for mortality at any time point. Death due to haemorrhage was more common in the standard care plus resuscitative endovascular balloon occlusion of the aorta group than in the standard care group. There were no serious adverse device effects. Resuscitative endovascular balloon occlusion of the aorta is less costly (probability 99%), due to the competing mortality risk but also substantially less effective in terms of lifetime quality-adjusted life-years (probability 91%). Limitations: The size of the study reflects the relative infrequency of exsanguinating traumatic haemorrhage in the United Kingdom. There were some baseline imbalances between groups, but adjusted analyses had little effect on the estimates. Conclusions: This is the first randomised trial of the addition of resuscitative endovascular balloon occlusion of the aorta to standard care in the management of exsanguinating haemorrhage. All the analyses suggest that a strategy of standard care plus resuscitative endovascular balloon occlusion of the aorta is potentially harmful. Future work: The role (if any) of resuscitative endovascular balloon occlusion of the aorta in the pre-hospital setting remains unclear. Further research to clarify its potential (or not) may be required. Trial registration: This trial is registered as ISRCTN16184981. Funding: This award was funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme (NIHR award ref: 14/199/09) and is published in full in Health Technology Assessment; Vol. 28, No. 54. See the NIHR Funding and Awards website for further award information.
Trauma (physical injury) is a major cause of death and disability. The most common cause of preventable death after injury is uncontrolled bleeding. Resuscitative endovascular balloon occlusion of the aorta is a technique whereby a small balloon is inflated in the aorta (main blood vessel) which aims to limit blood loss until an operation can be done to stop the bleeding. In this study, which is the first randomised trial in the world of this technique, we investigated whether adding resuscitative endovascular balloon occlusion of the aorta to the standard care received in a major trauma centre reduced the risk of death in trauma patients who had life-threatening uncontrolled bleeding. The study took place in 16 major trauma centres in the United Kingdom. Ninety adult trauma patients with confirmed or suspected uncontrolled bleeding took part and were randomly divided into two groups: (1) those who received standard care and (2) those who received standard care plus resuscitative endovascular balloon occlusion of the aorta. We followed participants for 6 months using routinely collected data from the National Health Service and from the Trauma Audit Research Network registry. We also contacted surviving patients at 6 months to ask about their quality of life. In the standard care group, 42% of participants died within 90 days of their injury compared to 54% of participants in the standard care plus resuscitative endovascular balloon occlusion of the aorta group. Risk of death was also higher in the standard care plus resuscitative endovascular balloon occlusion of the aorta group at all other time points (3, 6 and 24 hours, in hospital and at 6 months). Overall, the study showed that the use of resuscitative endovascular balloon occlusion of the aorta in hospital increased the risk of death.
Asunto(s)
Oclusión con Balón , Análisis Costo-Beneficio , Procedimientos Endovasculares , Resucitación , Humanos , Oclusión con Balón/métodos , Femenino , Masculino , Reino Unido , Adulto , Persona de Mediana Edad , Resucitación/métodos , Procedimientos Endovasculares/métodos , Hemorragia/terapia , Aorta , Teorema de Bayes , Torso , Años de Vida Ajustados por Calidad de Vida , Heridas y Lesiones/terapia , Heridas y Lesiones/complicaciones , Anciano , Centros TraumatológicosRESUMEN
OBJECTIVE: The Human Acellular Vessel (HAV) is a novel, off-the-shelf biologic conduit being evaluated for arterial reconstructions. Regulatory studies in peripheral arterial disease (PAD) to date have consisted of single-arm cohorts with no comparator groups to contrast performance against established standards. This study aimed to compare outcomes of the HAV with autologous great saphenous vein (GSV) in patients with advanced PAD undergoing infrageniculate bypass. METHODS: Patients with advanced PAD and no autologous conduit who underwent bypass with the 6-mm diameter HAV (Group 1; n = 34) (March 2021-February 2024) were compared with a multicenter historical cohort who had bypass with single-segment GSV (group 2; n = 88) (January 2017-December 2022). The HAV was used under an Investigational New Drug protocol issued by the Food and Drug Administration (FDA) under the agency's Expanded Access Program. RESULTS: Demographics were comparable between groups (mean age 69 ± 10 years; 71% male). Group 1 had higher rates of tobacco use (37 pack-years vs 28 pack-years; P = .059), coronary artery disease (71% vs 43%; P = .007), and prior coronary artery bypass grafting (38% vs 14%; P = .003). Group 1 had more patients classified as wound, ischemia, and foot infection clinical stage 4 (56% vs 33%; P = .018) and with previous index leg revascularizations (97% vs 53%; P < .001). Both groups had a similar number of patients with chronic limb-threatening ischemia (Rutherford class 4-6) (88% vs 86%; P = .693) and Global Anatomic Staging System stage III (91% vs 96%; P = .346). Group 1 required a composite conduit (two HAV sewn together) in 85% of bypasses. The tibial vessels were the target in 79% of group 1 and 100% of group 2 (P < .001). Group 1 had a lower mean operative time (364 minutes vs 464 minutes; P < .001). At a median of 12 months, major amputation-free survival (73% vs 81%; P = .55) and overall survival (84% vs 88%; P = .20) were comparable. Group 1 had lower rates of primary patency (36% vs 50%; P = .044), primary-assisted patency (45% vs 72%; P = .002), and secondary patency (64% vs 72%; P = .003) compared with group 2. CONCLUSIONS: Implanted under Food and Drug Administration Expanded Access provisions, the HAV was more likely to be used in redo operations and cases with more advanced limb ischemia than GSV. Despite modest primary patency, the HAV demonstrated resilience in a complex cohort with no autologous conduit options, achieving good secondary patency and providing major amputation-free survival comparable with GSV at 12 months.
Asunto(s)
Amputación Quirúrgica , Isquemia Crónica que Amenaza las Extremidades , Enfermedad Arterial Periférica , Vena Safena , Grado de Desobstrucción Vascular , Humanos , Vena Safena/trasplante , Femenino , Masculino , Anciano , Persona de Mediana Edad , Enfermedad Arterial Periférica/cirugía , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Enfermedad Arterial Periférica/mortalidad , Factores de Tiempo , Estudios Retrospectivos , Resultado del Tratamiento , Isquemia Crónica que Amenaza las Extremidades/cirugía , Recuperación del Miembro , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Implantación de Prótesis Vascular/instrumentación , Factores de Riesgo , Complicaciones Posoperatorias/etiologíaRESUMEN
OBJECTIVE: Type B intramural hematoma (IMH) is often managed medically, yet may progress to dissection, aneurysmal dilation, or rupture. The aim of this study was to report the natural history of medically managed Type B IMH, and factors associated with progression. METHODS: We reviewed patients with medically managed Type B IMH between January 1995 to December 2022 at a single center. Any patients with immediate surgical or endovascular intervention were excluded. Demographic profiles, comorbidities, imaging, and follow-up details were reviewed. Patients were divided into two groups: Group 1 had isolated IMH, and Group 2 had IMH along with aneurysm or dissection at the time of presentation. On follow-up, progression was defined as degeneration to aneurysm/dissection or increase in the thickness of IMH in Group 1. In Group 2, progression was an increase in the size of aneurysm or development of new dissection. RESULTS: Of 104 patients with Type B IMH during the study period, 92 were medically managed. The median age was 77 years, and 45 (48.9%) were females. Comorbidities included hypertension (83.7%), hypercholesterolemia (44.6%), and active smoking (47.8%). Mean Society for Vascular Surger comorbidity score was 6.3. Mean IMH thickness and aortic diameter at presentation were 8.9 mm and 38.3 mm, respectively. Median follow-up was 55 months. Overall survival at 1 year and 5 years was 85.8% and 61.9%, respectively. During follow-up, 19 patients (20.7%) required intervention, more common in Group 2 (Group 1, 8/66; 12.3% vs Group 2, 11/26; 42.3%; P = .001). This resulted in higher freedom from intervention in Group 1 at 1 year (93.5% vs 62.7%) and 5 years (87.5% vs 51.1%; P < .001). Indication for intervention was dissection (n = 4), aneurysm (n = 12), and progression of IMH (n = 3). In Group 1, progression was seen in 25 (37.9%), three (4.5%) remained stable, 29 (43.9%) had complete resolution of IMH, and nine patients were lost to follow-up. In Group 2, 11 patients (42.3%) had progression, seven (26.9%) remained stable, and eight were lost to follow-up. IMH thickness at presentation >7.2 mm is associated with both increased odds of progression (odds ratio, 3.3; 95% confidence interval, 1.2-11.1; P = .03) and intervention (odds ratio, 5.5; 95% confidence interval, 1.3-36.9; P = .03) during the follow-up. CONCLUSIONS: Although many patients with Type B IMH managed medically stabilize or regress, progression or need for intervention can occur in up to 40% of cases. This is associated with the presence of aneurysm, dissection, and IMH thickness. Long-term follow-up is mandatory as late interventions occur, particularly for higher risk patients.
Asunto(s)
Disección Aórtica , Progresión de la Enfermedad , Hematoma , Humanos , Femenino , Masculino , Hematoma/diagnóstico por imagen , Hematoma/terapia , Hematoma/mortalidad , Anciano , Estudios Retrospectivos , Factores de Tiempo , Factores de Riesgo , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/terapia , Disección Aórtica/mortalidad , Anciano de 80 o más Años , Persona de Mediana Edad , Resultado del Tratamiento , Medición de Riesgo , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/mortalidad , Rotura de la Aorta/cirugía , Rotura de la Aorta/terapiaRESUMEN
OBJECTIVE: Type II endoleaks (T2ELs) are the most common cause of reintervention after endovascular aneurysm repair (EVAR). Although most resolve spontaneously, the long-term implications of T2ELs remain elusive. We aim to evaluate the impact of persistent and late T2ELs on clinical outcomes after EVAR. METHODS: This was a single-institution retrospective review of patients who underwent EVAR for degenerative infrarenal abdominal aortic aneurysm between January 2010 and June 2022 with no type I (T1EL) or III (T3EL) endoleak seen at EVAR completion. Patients were categorized based on T2EL status. Group 1 included patients with never detected or transient T2ELs (detected at EVAR completion but not after). Group 2 encompassed persistent T2ELs (seen at EVAR completion and again during follow-up) and late T2ELs (detected for the first time at any point during follow-up). Time-to-event analysis was conducted using a time-dependent approach to T2EL status. Primary outcomes included freedom from sac enlargement (SE), aneurysm-related reinterventions, and overall survival. RESULTS: A total of 803 patients met inclusion criteria. Group 1 included 418 patients (52%), of which 85% had no T2ELs and 15% had transient T2ELs. Group 2 had 385 patients; 23% had persistent T2ELs, and 77% developed a new T2EL. Patients in group 1 had a higher prevalence of smoking (88% vs 83%; P < .001), chronic obstructive pulmonary disease (33% vs 25%; P = .008), chronic kidney disease (13% vs 8%; P = .021), and a higher mean Society for Vascular Surgery score (7 vs 6 points; P = .049). No differences were found in aneurysm diameter or morphology. Mean follow-up was 5 years for the entire cohort. In Group 2, 58 patients (15%) underwent T2EL treatment, most commonly transarterial embolization. At 10 years after EVAR, Group 2 was associated with lower freedom from SE (P < .001) and abdominal aortic aneurysm-related reinterventions (P < .001) and comparable overall survival (P = .42). More T1ELs were detected during follow-up in Group 2 (6 [1%] vs 20 [5%]; P = .004), with 15 (75%) of these detected at a median of 3 years after the T2EL. No difference between groups was observed in explant (0.7% vs 2.1%; P = .130) or aneurysm rupture (0.5% vs 1.3%; P = .269) rates. CONCLUSIONS: One-half of patients treated with infrarenal EVAR developed persistent/late T2ELs, which are associated with a higher risk of SE and reinterventions. No difference in overall survival or aneurysm rupture risk was seen at 10 years, based on T2EL status or T2EL intervention. A conservative approach to T2ELs may be appropriate for most patients with absent T1ELs or T3ELs.
Asunto(s)
Aneurisma de la Aorta Abdominal , Endofuga , Reparación Endovascular de Aneurismas , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/mortalidad , Endofuga/etiología , Endofuga/mortalidad , Endofuga/terapia , Endofuga/diagnóstico por imagen , Reparación Endovascular de Aneurismas/efectos adversos , Reparación Endovascular de Aneurismas/mortalidad , Reoperación , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del TratamientoRESUMEN
Traumatic injury leading to arterial damage has traditionally been repaired using autologous vein graft from the contralateral limb. This often requires a secondary surgical site and the potential of prolonged operative time for patients. We sought to assess the use of ipsilateral vs contralateral vein grafts in patients who experienced traumatic extremity vascular injury. A multicenter database was queried to identify arterial injuries requiring operative intervention with vein grafting. The primary outcome of interest was need for operative reintervention. Secondary outcomes included risk of thrombosis, infection, and intensive care unit length of stay. 358 patients (320 contralateral and 38 ipsilateral) were included in the analysis. The ipsilateral vein cohort did not display a statistically significant decrease in need for reoperation when compared to the contralateral group (11% vs 23%; OR 0.41, 95% CI -0.07-1.3; P = .14). Contralateral repair was associated with longer median intensive care unit (ICU) LOS (4.3 vs 3.1 days; P < .01).
Asunto(s)
Lesiones del Sistema Vascular , Humanos , Lesiones del Sistema Vascular/cirugía , Masculino , Femenino , Adulto , Persona de Mediana Edad , Estudios Retrospectivos , Tiempo de Internación/estadística & datos numéricos , Venas/trasplante , Reoperación , Injerto Vascular/métodos , Resultado del TratamientoRESUMEN
Pressure-volume (PV) loop analysis is a sophisticated invasive approach to quantifying load-dependent and independent measures of cardiac function. Biventricular (BV) PV loops allow left and right ventricular function to be quantified simultaneously and independently, which is important for conditions and certain physiologic states, such as ventricular decoupling or acute physiologic changes. BV PV loops can be performed in an entirely endovascular, percutaneous, and closed-chest setting. This technique is helpful in a survival animal model, as a percutaneous monitoring system during endovascular device experiments, or in cases where chest wall compliance is being tested or may be a confounder. In this article, we describe the end-to-end implementation of a completely endovascular, totally percutaneous, and closed-chest large animal model to obtain contemporaneous BV PV loops in 40 to 70 kg swine. We describe the associated surgical and technical challenges and our solutions to obtaining endovascular BV PV loops, closed-chest cardiac output, and stroke volume (including validation of the correction factor necessary for thermodilution), as well as how to perform endovascular inferior vena cava occlusion in this swine model. We also include techniques for data acquisition and analysis that are required for this method.
RESUMEN
OBJECTIVE: Patients with chronic limb-threatening ischemia (CLTI) and no great saphenous vein to use as a conduit for arterial bypass have a high risk for amputation despite advances in medical and endovascular therapies. This report presents findings from a U.S. Food and Drug Administration (FDA) supported study of the Human Acellular Vessel (HAV) (Humacyte Inc.) used as a conduit for arterial bypass in patients with CLTI and inadequate or absent autologous conduit. METHODS: The HAV is a 6-mm, 40-cm vessel created from human vascular smooth muscle cells seeded onto a polyglycolic acid scaffold pulsed in a bioreactor for 8 weeks as cells proliferate and the scaffold dissolves. The resultant vessel is decellularized, creating a nonimmunogenic conduit composed of collagen, elastin, and extracellular matrix. The FDA issued an Investigational New Drug for an intermediate-sized, single-center study of the HAV under the agency's Expanded Access Program in patients with advanced CLTI and inadequate or absent autologous conduit. Technical results and clinical outcomes were analyzed and reported. RESULTS: Between March 2021 and July 2023, 29 patients (20 males; mean age, 71 ± 11 years) underwent limb salvage operation using the HAV as a bypass conduit. Most patients had advanced CLTI (Rutherford class 5/6 in 72%; wound, ischemia, and foot infection stage 3/4 in 83%), and 97% had previously failed revascularization(s) of the extremity. Two HAVs were sewn together to attain the needed bypass length in 24 patients (83%). Bypasses were to tibial arteries in 23 patients (79%) and to the popliteal artery in 6 (21%). Technical success was 100%, and the 30-day mortality rate was 7% (2 patients). With 100% follow-up (median, 9.3 months), the limb salvage rate was 86% (25/29 patients). There were 16 reinterventions to restore secondary patency, of which 15 (94%) were successful. Primary and secondary patency of the HAV at 9 months were 59% and 71%, respectively. CONCLUSIONS: The HAV has demonstrated short- to intermediate-term safety and efficacy as an arterial bypass conduit in a complex cohort of patients with limb-threatening ischemia and no autologous options. This experience using the FDA's Expanded Access Program provides real-world data to inform regulatory deliberations and future trials of the HAV, including the study of the vessel as a first-line bypass conduit in less severe cases of chronic limb ischemia.
Asunto(s)
Implantación de Prótesis Vascular , Enfermedad Arterial Periférica , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Isquemia Crónica que Amenaza las Extremidades , Implantación de Prótesis Vascular/efectos adversos , Grado de Desobstrucción Vascular , Resultado del Tratamiento , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/cirugía , Factores de Riesgo , Extremidad Inferior/irrigación sanguínea , Isquemia/diagnóstico por imagen , Isquemia/cirugía , Recuperación del Miembro/métodos , Estudios RetrospectivosRESUMEN
INTRODUCTION: Acute proximal superior mesenteric artery (SMA) occlusion is highly lethal, and adjuncts are needed to mitigate ischemic injury until definitive therapy. We hypothesized that raising mean arterial pressure (MAP) >90 mmHg with norepinephrine may delay irreversible bowel ischemia by increasing gastroduodenal artery (GDA) flow despite possible pressor-induced vasospasm. METHODS: 12 anesthetized swine underwent laparotomy, GDA flow probe placement, and proximal SMA exposure and clamping. Animals were randomized between conventional therapy (CT) versus targeted MAP >90 mmHg (MAP push; MP) where norepinephrine was titrated after 45 min of SMA occlusion. Animals were followed until bowel death or 4 h. Kaplan-Meier bowel survival, mean normalized GDA flow, and histology were compared. RESULTS: 12 swine (mean 57.8 ± 7.6 kgs) were included, six per group. Baseline weight, HR, MAP and GDA flows were not different. Within 5 min following SMA clamping, all 12 animals had an increase in MAP without other intervention from 81.7 to 105.5 mmHg (29.1%, P < 0.01) with a concomitant 74.9% increase in GDA flow as compared to baseline (P < 0.01). Beyond 45 min postclamp, MAP was greater in the MP group as intended, as were GDA flows. Median time to irreversibly ischemic bowel was 31% longer for MAP push animals (CT: 178 versus MP: 233 min, P = 0.006), Hazard Ratio of CT 8.85 (95% CI: 1.86-42.06); 3/6 MP animals versus 0/6 CT animals with bowel survived to predetermined end point. CONCLUSIONS: In this swine model of acute complete proximal SMA occlusion, increasing MAP >90 mmHg with norepinephrine was associated with an increase in macrovascular blood flow through the GDA and bowel survival. Norepinephrine was not associated with worse bowel survival and a MAP push may increase the time window where ischemic bowel can be salvaged.
Asunto(s)
Presión Arterial , Isquemia Mesentérica , Animales , Presión Sanguínea , Isquemia/patología , Arteria Mesentérica Superior/cirugía , Isquemia Mesentérica/etiología , Isquemia Mesentérica/cirugía , Norepinefrina , PorcinosRESUMEN
BACKGROUND: Calvarial defects are severe injuries that can result from a wide array of etiologies. Reconstructive modalities for these clinical challenges include autologous bone grafting or cranioplasty with biocompatible alloplastic materials. Unfortunately, both approaches are limited by factors such as donor site morbidly, tissue availability, and infection. Calvarial transplantation offers the potential opportunity to address skull defect form and functional needs by replacing "like-with-like" tissue but remains poorly investigated. METHODS: Three adult human cadavers underwent circumferential dissection and osteotomy to raise the entire scalp and skull en-bloc. The vascular pedicles of the scalp were assessed for patency and perfused with color dye, iohexol contrast agent for computed tomography (CT) angiography, and indocyanine green for SPY-Portable Handheld Imager assessment of perfusion to the skull. RESULTS: Gross changes were appreciated to the scalp with color dye, but not to bone. CT angiography and SPY-Portable Handheld Imager assessment confirmed perfusion from the vessels of the scalp to the skull beyond midline. CONCLUSION: Calvarial transplantation may be a technically viable option for skull defect reconstruction that requires vascularized composite tissues (bone and soft tissue) for optimal outcomes.
Asunto(s)
Procedimientos de Cirugía Plástica , Cuero Cabelludo , Adulto , Humanos , Cuero Cabelludo/cirugía , Cráneo/cirugía , Cráneo/lesiones , Materiales Biocompatibles , Trasplante Óseo/métodos , Perfusión , CadáverRESUMEN
Importance: Bleeding is the most common cause of preventable death after trauma. Objective: To determine the effectiveness of resuscitative endovascular balloon occlusion of the aorta (REBOA) when used in the emergency department along with standard care vs standard care alone on mortality in trauma patients with exsanguinating hemorrhage. Design, Setting, and Participants: Pragmatic, bayesian, randomized clinical trial conducted at 16 major trauma centers in the UK. Patients aged 16 years or older with exsanguinating hemorrhage were enrolled between October 2017 and March 2022 and followed up for 90 days. Intervention: Patients were randomly assigned (1:1 allocation) to a strategy that included REBOA and standard care (n = 46) or standard care alone (n = 44). Main Outcomes and Measures: The primary outcome was all-cause mortality at 90 days. Ten secondary outcomes included mortality at 6 months, while in the hospital, and within 24 hours, 6 hours, or 3 hours; the need for definitive hemorrhage control procedures; time to commencement of definitive hemorrhage control procedures; complications; length of stay; blood product use; and cause of death. Results: Of the 90 patients (median age, 41 years [IQR, 31-59 years]; 62 [69%] were male; and the median Injury Severity Score was 41 [IQR, 29-50]) randomized, 89 were included in the primary outcome analysis because 1 patient in the standard care alone group declined to provide consent for continued participation and data collection 4 days after enrollment. At 90 days, 25 of 46 patients (54%) had experienced all-cause mortality in the REBOA and standard care group vs 18 of 43 patients (42%) in the standard care alone group (odds ratio [OR], 1.58 [95% credible interval, 0.72-3.52]; posterior probability of an OR >1 [indicating increased odds of death with REBOA], 86.9%). Among the 10 secondary outcomes, the ORs for mortality and the posterior probabilities of an OR greater than 1 for 6-month, in-hospital, and 24-, 6-, or 3-hour mortality were all increased in the REBOA and standard care group, and the ORs were increased with earlier mortality end points. There were more deaths due to bleeding in the REBOA and standard care group (8 of 25 patients [32%]) than in standard care alone group (3 of 18 patients [17%]), and most occurred within 24 hours. Conclusions and Relevance: In trauma patients with exsanguinating hemorrhage, a strategy of REBOA and standard care in the emergency department does not reduce, and may increase, mortality compared with standard care alone. Trial Registration: isrctn.org Identifier: ISRCTN16184981.
Asunto(s)
Oclusión con Balón , Exsanguinación , Humanos , Masculino , Adulto , Femenino , Exsanguinación/complicaciones , Teorema de Bayes , Estudios Retrospectivos , Hemorragia/etiología , Hemorragia/terapia , Aorta , Oclusión con Balón/efectos adversos , Oclusión con Balón/métodos , Resucitación/métodos , Puntaje de Gravedad del Traumatismo , Servicio de Urgencia en Hospital , Reino UnidoRESUMEN
Prehospital resuscitation is a dynamic field now being energized by new technologies and a shift in thinking regarding intravascular resuscitation. Growing evidence discourages use of intravenous (IV) crystalloid and colloid solutions in trauma, whereas blood products, particularly whole blood, are becoming preferred. Although randomized clinical trials validating definitive resuscitative protocols are still lacking, most preclinical and clinical indicators support this approach. In addition, emerging technologies such as external and endovascular hemorrhage control devices and extracorporeal perfusion are now being used routinely, even in the prehospital setting in many countries, generating new lines of emerging investigations for trauma specialists.
Asunto(s)
Servicios Médicos de Urgencia , Heridas y Lesiones , Humanos , Hemorragia/terapia , Resucitación/métodos , Perfusión , Soluciones CristaloidesRESUMEN
OBJECTIVES: While methods of endovascular carotid artery stenting have improved over time, concerns surrounding the safety and efficacy of stenting for blunt carotid injury (BCI) remain. This study aims to present our approach to carotid artery stenting (CAS) by incorporating new technologies such as flow-diverting stents and circuits. METHODS: There is no robust evidence to support routine carotid artery stenting; however, there are several therapeutic options and approaches for treating BCI that currently require an individualized approach. Endovascular stenting and specific stent selection are largely dictated by the disease process the surgeon intends to treat. We will discuss patient selection, medical management, and the most common revascularization techniques, including transfemoral stenting, trans-carotid arterial revascularization using flow reversal, and stent-assisting coiling. RESULTS: It must be stressed that endovascular intervention is not an alternative to or preclusive of antithrombotic or anticoagulant therapy. In the setting of BCI, transfemoral CAS is most appropriate in patients who are symptomatic, have a rapidly progressing or large lesion, and do not have a soft thrombus present due to risk of embolism. Unlike transfemoral CAS, TCAR offers an elegant solution for embolic protection when patients have a soft thrombus present. In the case of a large pseudoaneurysm, we perform stent-assisted coiling. CONCLUSIONS: We practice selective endovascular intervention, stenting lesions that are flow-limiting or have large or rapidly expanding pseudoaneurysms, and only in patients for whom anticoagulation and antiplatelet agents are not contraindicated. As technology and investigation progress, the concerns regarding the safety and the role of endovascular intervention in the treatment of BCI will be more clearly defined.
RESUMEN
BACKGROUND: Calvarial defects are severe injuries that can result from a wide array of etiologies. Reconstructive modalities for these clinical challenges include autologous bone grafting or cranioplasty with biocompatible alloplastic materials. Unfortunately, both approaches are limited by factors such as donor site morbidly, tissue availability, and infection. Calvarial transplantation offers the potential opportunity to address skull defect form and functional needs by replacing "like-with-like" tissue but remains poorly investigated. METHODS: Three adult human cadavers underwent circumferential dissection and osteotomy to raise the entire scalp and skull en-bloc. The vascular pedicles of the scalp were assessed for patency and perfused with color dye, iohexol contrast agent for computed tomography (CT) angiography, and indocyanine green for SPY-Portable Handheld Imager assessment of perfusion to the skull. RESULTS: Gross changes were appreciated to the scalp with color dye, but not to bone. CT angiography and SPY-Portable Handheld Imager assessment confirmed perfusion from the vessels of the scalp to the skull beyond midline. DISCUSSION/CONCLUSION: Calvarial transplantation may be a technically viable option for skull defect reconstruction that requires vascularized composite tissues (bone and soft tissue) for optimal outcomes.
RESUMEN
BACKGROUND: Variations in admission patterns have been previously identified in non-elective surgical services, but minimal data on the subject exists with respect to burn admissions. Improved understanding of the temporal pattern of burn admissions could inform resource utilization and clinical staffing. We hypothesize that burn admissions have a predictable temporal distribution with regard to the time of day, day of week, and season of year in which they present. STUDY DESIGN: A retrospective, cohort observational study of a single burn center from 7/1/2016 to 3/31/2021 was performed on all admissions to the burn surgery service. Demographics, burn characteristics, and temporal data of burn admissions were collected. Bivariate absolute and relative frequency data was captured and plotted for all patients who met inclusion criteria. Heat-maps were created to visually represent the relative admission frequency by time of day and day of week. Frequency analysis grouped by total body surface area against time of day and relative encounters against day of year was performed. RESULTS: 2213 burn patient encounters were analyzed, averaging 1.28 burns per day. The nadir of burn admissions was from 07:00 and 08:00, with progressive increase in the rate of admissions over the day. Admissions peaked in the 15:00 hour and then plateaued until midnight (p<0.001). There was no association between day of week in the burn admission distribution (p>0.05), though weekend admissions skewed slightly later (p = 0.025). No annual, cyclical trend in burn admissions was identified, suggesting that there is no predictable seasonality to burn admissions, though individual holidays were not assessed. CONCLUSION: Temporal variations in burn admissions exist, including a peak admission window late in the day. Furthermore, we did not find a predictable annual pattern to use in guiding staffing and resource allocation. This differs from findings in trauma, which identified admission peaks on the weekends and an annual cycle that peaks in spring and summer.
Asunto(s)
Hospitalización , Admisión del Paciente , Humanos , Estudios Retrospectivos , Estudios de Cohortes , Unidades de Quemados , Tiempo de InternaciónRESUMEN
Acute mesenteric ischemia (AMI) constitutes a life-threatening problem that can result in death, multiorgan failure, and severe nutritional disability. Although AMI is a rare cause of acute abdominal emergencies, ranging between 1 and 2 individuals per 10,000, the morbidity and mortality rates are high. Arterial embolic etiology composes nearly one-half of AMIs, with a sudden onset of severe abdominal pain considered the most common symptom. Arterial thrombosis is the second most common cause of AMI, which presents similarly to arterial embolic AMI, although often more severe due to anatomic differences. Veno-occlusive causes of AMI are the third most common and are associated with an insidious onset of vague abdominal pain. Each patient is unique, and the treatment plan should be tailored to their individual needs. This may include considering the patient's age, comorbidities, and overall health, as well as their preferences and personal circumstances. A multidisciplinary approach involving specialists from different fields, such as surgeons, interventional radiologists, and intensivists, is recommended for the best possible outcome. Potential challenges in tailoring an optimal treatment plan for AMI may include delayed diagnosis, limited availability of specialized care, or patient factors that make some interventions less feasible. Addressing these challenges requires a proactive and collaborative approach, with regular review and adjustment of the treatment plan as needed to ensure the best possible outcome for each patient.
Asunto(s)
Embolia , Isquemia Mesentérica , Trombosis , Humanos , Urgencias Médicas , Mesenterio , Isquemia Mesentérica/diagnóstico por imagen , Isquemia Mesentérica/terapia , Embolia/complicaciones , Enfermedad Aguda , Resultado del Tratamiento , Estudios RetrospectivosRESUMEN
This cohort study quantifies the yearly trends and outcomes of transcarotid artery revascularization vs transfemoral carotid artery stenting among high-risk patients from 2015 to 2021.
Asunto(s)
Estenosis Carotídea , Procedimientos Endovasculares , Accidente Cerebrovascular , Humanos , Estenosis Carotídea/cirugía , Stents , Resultado del Tratamiento , Factores de Riesgo , Estudios Retrospectivos , Medición de RiesgoRESUMEN
BACKGROUND: Thoracic aortic stent grafts are thought to decrease aortic compliance and may contribute to hypertension and heart failure after thoracic endovascular aortic repair (TEVAR). Left ventricular (LV) biomechanics immediately after TEVAR, however, have not been quantified. Pressure-volume (PV) loop analysis provides gold-standard LV functional information. The aim of this study is to use an LV PV loop catheter and analysis to characterize the LV biomechanics before and acutely after TEVAR. METHODS: Anesthetized Yorkshire swine (N = 6) were percutaneously instrumented with an LV PV loop catheter. A 20 mm × 10 cm stent graft was deployed distal to the left subclavian via the femoral artery under fluoroscopy. Cardiac biomechanics were assessed before and after TEVAR. As a sensitivity analysis, inferior vena cava occlusion with PV loop assessment was performed pre and post-TEVAR in 1 animal to obtain preload and afterload-independent end-systolic and end-diastolic PV relationships (ESPVR and EDPVR). RESULTS: All animals underwent successful instrumentation and TEVAR. Post-TEVAR, all 6 animals had higher mean LV ESP (106 vs. 118 mm Hg, P = 0.04), with no change in the EDPVR. inferior vena cava occlusion also moved the ESPVR curve upward and leftward, indicating increased LV work per unit time. There was no augmentation of EDPVR following TEVAR (P > 0.05). Postmortem exams in all animals revealed appropriate stent placement and no technical complications. CONCLUSIONS: TEVAR was associated with an acute increase in LV end-systolic pressure and shift in the ESPVR, indicating increased ventricular work. This data provides potential mechanistic insights into the development of post-TEVAR hypertension and heart failure. Future stent graft innovation should focus on minimizing the changes in cardiac physiology.
Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Insuficiencia Cardíaca , Hipertensión , Porcinos , Animales , Aneurisma de la Aorta Torácica/cirugía , Fenómenos Biomecánicos , Resultado del Tratamiento , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Procedimientos Endovasculares/efectos adversos , Insuficiencia Cardíaca/etiología , Stents , Implantación de Prótesis Vascular/efectos adversos , Estudios Retrospectivos , Prótesis VascularRESUMEN
Introduction: Transcarotid artery revascularization (TCAR) with flow reversal has substantially changed the management of carotid artery stenosis, enabling an endovascular approach with a periprocedural stroke rate as low as or lower than that of open carotid surgery. The use of TCAR for blunt carotid artery injury has not yet been described. Methods: A review of the use of TCAR for blunt carotid artery injury was performed at a single center from October 2020 to August 2021. The patient demographics, mechanism of injury, and outcomes were collected and compared. Results: Ten carotid stents were placed via TCAR in eight patients for hemodynamically significant blunt carotid artery injuries. No periprocedural neurologic events occurred, and all stents remained patent during short-term follow-up. Conclusions: TCAR is feasible and safe in the management of significant blunt carotid artery injuries. More data are needed regarding the long-term outcomes and ideal surveillance intervals.
RESUMEN
OBJECTIVE: Thoracic Endovascular Aortic Repair (TEVAR) is well established in humans. Despite widespread use, additional research questions related to thoracic aortic stenting and endovascular innovation require large animal models. Translating human TEVAR devices and techniques into animal models, however, is a challenge even for experienced endovascular surgeons looking to develop a large animal TEVAR model.This article describes swine-specific strategies to deploy human TEVAR stent grafts, delineate how to select, size, prepare, and re-use human stents and deployment systems in swine, and how to translate human imaging modalities to large animal TEVAR. METHODS: We describe a selection of related TEVAR models and techniques in Yorkshire swine to support scientific inquiry. This includes an animal husbandry and pre-operative preparation and planning program. All imaged specimens in this paper are castrated male Yorkshire swine in the 60-80 kg range and underwent TEVAR with the Medtronic Navion stent and deployment system. RESULTS: To study human aortic stent grafts in swine, the animals generally must be at least 50 kgs to guarantee a 2 cm internal aortic diameter at the left subclavian, and for the iliac arteries to accommodate the human deployment system. Swine will have longer torsos and shorter iliofemoral segments than a human of the same weight which can make human deployment systems too short to reach the left subclavian from the femoral arteries in larger animals. We provide techniques to overcome this, including open iliac access or upside-down carotid TEVAR, which may be particularly useful if the scientific data would be confounded by iliofemoral access.Unlike humans that present clinically with axial imaging, swine will generally not have preoperative imaging, and many translational research laboratories do not have access to inexpensive preoperative CT, or any intraoperative CT scanning, which we are fortunate to have. We describe, therefore, several strategies for imaging in this setting including TEVAR via C-arm fluoroscopy and with or without in-laboratory CT scanning. Due to the low-resource setting of most large animal laboratories, as compared to a human hybrid room, we also describe several techniques to reduce cost and reuse materials, including the stent grafts, which at the end of non-survival experiments can be recovered during necropsy, cleaned, reinserted into the deployment device and reused on additional animals. CONCLUSIONS: This article describes a collection of related techniques and tips to translate human TEVAR imaging, sizing/selection, deployment, and anatomy to swine research. Using this framework alone, an experienced human vascular or endovascular surgeon may develop a complete aortic stenting animal model with strategies for scientific data acquisition.
RESUMEN
Intraoperative computed tomography (CT) imaging with endovascular delivery of intra-arterial (IA) contrast could potentially provide higher attenuation with lower contrast volumes than intravenous (IV) administration. We aimed to compare IA and IV contrast use for organ-specific CT abdominal imaging. Five anesthetized swine had external jugular and brachial artery access with ascending aortic pigtail placement. An IV protocol was 100 mL at 5 mL/sec over 20 sec vs 50 mL of IA contrast at 5 mL/sec over 10 sec. Region-of-interest markers were applied to anatomical regions to measure attenuation (HU) over time. IA and IV contrast protocols achieved adequate aortic opacification (IA, 455 ± 289 vs IV, 450 ± 114 HU). The IA contrast aortic attenuation curve reached peak attenuation compared with IV contrast (IA, 8 vs 23 sec; P < .001). Time to peak attenuation was similar between IA and IV contrast in the portal vein (IA, 38 vs IV, 42 sec, P = .25). IA administration achieved a superior contrast-to-noise ratio (CNR) in less time compared with IV (R2 = .94; P < .001). IA contrast achieved adequate opacification with less bolus broadening and a superior CNR compared with IV contrast while using a smaller contrast volume for directed organ-directed imaging.