Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Phys Rev Lett ; 122(6): 066401, 2019 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-30822065

RESUMEN

Using the satellite structure of the Lγ_{1} line in nonresonant x-ray emission spectra, we probe the high-pressure evolution of the bare 4f signature of the early light lanthanides at ambient temperature. For Ce and Pr the satellite peak experiences a sudden reduction concurrent with their respective volume collapse (VC) transitions. These new experimental results are supported by calculations using state-of-the-art extended atomic structure codes for Ce and Pr, and also for Nd, which does not exhibit a VC. Our work suggests that changes to the 4f occupation are more consistently associated with evolution of the satellite than is the reduction of the 4f moment. Indeed, we show that in the case of Ce, mixing of a higher atomic angular momentum state, driven by the increased hybridization, acts to obscure the expected satellite reduction. These measurements emphasize the importance of a unified study of a full set of microscopic observables to obtain the most discerning test of the underlying, fundamental f-electron phenomena at high pressures.

2.
Rev Sci Instrum ; 85(11): 113906, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430123

RESUMEN

We report the development of a laboratory-based Rowland-circle monochromator that incorporates a low power x-ray (bremsstrahlung) tube source, a spherically bent crystal analyzer, and an energy-resolving solid-state detector. This relatively inexpensive, introductory level instrument achieves 1-eV energy resolution for photon energies of ∼5 keV to ∼10 keV while also demonstrating a net efficiency previously seen only in laboratory monochromators having much coarser energy resolution. Despite the use of only a compact, air-cooled 10 W x-ray tube, we find count rates for nonresonant x-ray emission spectroscopy comparable to those achieved at monochromatized spectroscopy beamlines at synchrotron light sources. For x-ray absorption near edge structure, the monochromatized flux is small (due to the use of a low-powered x-ray generator) but still useful for routine transmission-mode studies of concentrated samples. These results indicate that upgrading to a standard commercial high-power line-focused x-ray tube or rotating anode x-ray generator would result in monochromatized fluxes of order 10(6)-10(7) photons/s with no loss in energy resolution. This work establishes core technical capabilities for a rejuvenation of laboratory-based hard x-ray spectroscopies that could have special relevance for contemporary research on catalytic or electrical energy storage systems using transition-metal, lanthanide, or noble-metal active species.

3.
Rev Sci Instrum ; 84(8): 083908, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24007080

RESUMEN

We present design and performance details for a polycapillary-coupled x-ray spectrometer that provides very high collection efficiency at a moderate energy resolution suitable for many studies of nonresonant x-ray emission spectroscopy, especially for samples of heavy elements under high pressures. Using a single Bragg analyzer operating close to backscattering geometry so as to minimize the effect of the weak divergence of the quasicollimated exit beam from the polycapillary optic, this instrument can maintain a typical energy resolution of 5 eV over photon energies from 5 keV to 10 keV. We find dramatically improved count rates as compared to a traditional higher-resolution instrument based on a single spherically bent crystal analyzer.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA