Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Crit Care ; 18(6): 603, 2014 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-25407329

RESUMEN

INTRODUCTION: Electrical velocimetry (EV) is a type of impedance cardiography, and is a non-invasive and continuously applicable method of cardiac output monitoring. Transthoracic echocardiography (TTE) is non-invasive but discontinuous. METHODS: We compared EV with TTE in pediatric intensive care patients in a prospective single-center observational study. Simultaneous, coupled, left ventricular stroke volume measurements were performed by EV using an Aesculon® monitor and TTE (either via trans-aortic valve flow velocity time integral [EVVTI], or via M-mode [EVMM]). H0: bias was less than 10% and the mean percentage error (MPE) was less than 30% in Bland-Altman analysis between EV and TTE. If appropriate, data were logarithmically transformed prior to Bland-Altman analysis. RESULTS: A total of 72 patients (age: 2 days to 17 years; weight: 0.8 to 86 kg) were analyzed. Patients were divided into subgroups: organ transplantation (OTX, n = 28), sepsis or organ failure (SEPSIS, n = 16), neurological patients (NEURO, n = 9), and preterm infants (PREM, n = 26); Bias/MPE for EVVTI was 7.81%/26.16%. In the EVVTI subgroup analysis for OTX, NEURO, and SEPSIS, bias and MPE were within the limits of H0, whereas the PREM subgroup had a bias/MPE of 39.00%/46.27%. Bias/MPE for EVMM was 8.07%/37.26% where the OTX and NEURO subgroups were within the range of H0, but the PREM and SEPSIS subgroups were outside the range. Mechanical ventilation, non-invasive continuous positive airway pressure ventilation, body weight, and secondary abdominal closure were factors that significantly affected comparison of the methods. CONCLUSIONS: This study shows that EV is comparable with aortic flow-based TTE for pediatric patients.


Asunto(s)
Gasto Cardíaco/fisiología , Ecocardiografía/métodos , Unidades de Cuidado Intensivo Pediátrico , Monitoreo Fisiológico/métodos , Reología/métodos , Adolescente , Cardiografía de Impedancia/métodos , Cardiografía de Impedancia/normas , Niño , Preescolar , Ecocardiografía/normas , Femenino , Humanos , Lactante , Recién Nacido , Unidades de Cuidado Intensivo Pediátrico/normas , Masculino , Monitoreo Fisiológico/normas , Estudios Prospectivos , Reología/normas , Volumen Sistólico/fisiología
2.
Int J Pediatr ; 2012: 452909, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23213342

RESUMEN

Introduction. Anemia is prevalent in adult heart failure patients and appears to be an independent risk factor for morbidity and mortality. The purpose of this work is to determine the prevalence of anemia in children with heart failure from dilated cardiomyopathy (DCM) and to evaluate its influence on morbidity and mortality. Methods. A homogenous group of 58 children with congestive heart failure from DCM was evaluated for heart failure symptoms, appearance of anemia, hospitalization, age of first clinical appearance, necessity of transfusion, and death during medical attendance. Anemic and nonanemic patients were analyzed for differences in age distribution, morbidity, and mortality. Results. Anemia was present in 64% of DCM patients. Hospitalization secondary to heart failure was significantly elevated in heart failure patients with anemia (mean 35.1 ± 40.5 versus 9.97 ± 9.65 days per year, P < 0.05). However, mortality was not elevated. Significant relations of age and prevalence of anemia or age and severity of anemia did not appear. Conclusion. Anemia is prevalent in pediatric patients with congestive heart failure from DCM and appears in all age classes. Hospitalization as a surrogate of morbidity is elevated in heart failure patients developing anemia, but mortality risk did not increase.

3.
Cardiol Young ; 20(4): 455-8, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20519055

RESUMEN

Paclitaxel-eluting balloons are a new and innovative method in the treatment of in-stent stenosis and small vessel disease in adult cardiac pathology. The treatment of congenital pulmonary vein stenosis is difficult to manage, and results in a high mortality rate due to residual or recurrent stenosis. We report the first case of treatment for neonatal pulmonary vein restenosis with a paclitaxel-eluting balloon.


Asunto(s)
Cateterismo/instrumentación , Stents Liberadores de Fármacos , Estenosis de la Válvula Pulmonar/congénito , Estenosis de la Válvula Pulmonar/terapia , Factores de Edad , Humanos , Recién Nacido , Paclitaxel/efectos adversos , Estenosis de la Válvula Pulmonar/diagnóstico , Moduladores de Tubulina/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...