Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Clin Transl Radiat Oncol ; 29: 20-26, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34027140

RESUMEN

BACKGROUND: For decades, Anterior-Posterior/Posterior-Anterior (AP/PA) photon beams were standard-of-care for flank irradiation in children with renal cancer. Recently, highly conformal flank target volumes were defined correcting for postoperative organ shift and intra-fraction motion.By radiotherapy treatment plan comparison, this study aims to estimate the clinical benefits and potential risks of combining highly conformal target volumes with Volumetric-Modulated Arc Therapy (VMAT) versus conventional target volumes with AP/PA beams for flank irradiation. MATERIALS AND METHODS: Twenty consecutive renal tumor cases (left/right-sided:10/10; median age:3.2 years) were selected. Highly conformal flank target volumes were generated for VMAT, while conventional target volumes were used for AP/PA. For each case, the dose to the organs at risk (OARs) and Total Body Volume (TBV) was calculated to compare VMAT with AP/PA treatment plans for a prescribed dose (PD) of 14.4/1.8 Gy. Dose constraint violation of the tail of the pancreas and spleen (Dmean < 10 Gy), heart (D50 < 5 Gy) or mammary buds (Dmean < 10 Gy) were prioritized as potentially beneficial for clinics. RESULTS: Highly conformal Planning Target Volumes (PTV) were smaller than conventional volumes (mean ΔPTVAP/PA-PTVVMAT: 555 mL, Δ60%, p=<0.01). A mean dose reduction favoring VMAT was observed for almost all OARs. Dose constraints to the tail of the pancreas, spleen, heart and mammary buds were fulfilled in 8/20, 12/20, 16/20 and 19/20 cases with AP/PA, versus 14/20, 17/20, 20/20 and 20/20 cases with VMAT, respectively. In 12/20 cases, VMAT prevented the dose constraint violation of one or more OARs otherwise exceeded by AP/PA. VMAT increased the TBV receiving 10% of the PD, but reduced the amount of irradiated TBV for all higher doses. CONCLUSION: Compared to 14.4 Gy flank irradiation using conventional AP/PA photon beams, an estimated clinical benefit by dose reduction to the OARs can be expected in 60% of the pediatric renal tumor cases using highly conformal flank target volumes combined with VMAT.

2.
Radiother Oncol ; 159: 249-254, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33845042

RESUMEN

BACKGROUND AND PURPOSE: In pediatric renal tumors, conventional two opposing photon beams have been used to cover the postoperative flank target volume for decades. This single center study describes the locoregional outcome using highly conformal flank target volumes adjusted for postoperative changes and intra-fraction motion combined with Volumetric-Modulated Arc Therapy (VMAT). MATERIALS AND METHODS: Between 01-2015 and 12-2019, 36/161 newly diagnosed patients with renal tumors underwent flank only irradiation (n = 30) or flank + whole lung irradiation (n = 6) using highly conformal target volumes in line with the SIOP-RTSG consensus statement. VMAT consisted of full-arc 10MV photon beams optimized for constraints of the organs at risk. In case of locoregional relapses, image co-registration and dose reconstruction was performed. Each relapse was classified as either 'infield' (V95%relapse: ≥99.0%), 'marginal' (V95%relapse: 20.0-98.9%) or 'outfield' (V95%relapse: 0-19.9%). RESULTS: At a median follow-up from diagnosis of 3.1 years (range:0.4-5.7), the estimated 2-year Locoregional Control Rate, Disease-Free Interval and Overall Survival were 94%, 91% and 94%, respectively. Locoregional relapse was observed in two patients. One patient had a combined tumor bed and regional recurrence, classified as infield (V95%relapse: 100%) and outfield (V95%relapse: 1.2%). The second patient had a regional relapse in the inferior vena cava classified as marginal recurrence (V95%relapse: 93%). Relapses would not have been adequately covered by conventional beams. CONCLUSIONS: This single center analysis provides encouraging evidence that excellent locoregional control can be obtained by using highly conformal flank target volumes with VMAT in pediatric renal tumors. The safety of this approach will be validated in a prospective multicenter study.


Asunto(s)
Neoplasias Renales , Radioterapia de Intensidad Modulada , Niño , Humanos , Neoplasias Renales/radioterapia , Recurrencia Local de Neoplasia/radioterapia , Estudios Prospectivos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
3.
Clin Transl Radiat Oncol ; 28: 39-47, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33796796

RESUMEN

BACKGROUND AND PURPOSE: Recently, the SIOP-RTSG developed a highly-conformal flank target volume definition for children with renal tumors. The aims of this study were to evaluate the inter-clinician delineation variation of this new target volume definition in an international multicenter setting and to explore the necessity of quality assurance. MATERIALS AND METHODS: Six pediatric renal cancer cases were transferred to ten radiation oncologists from seven European countries ('participants'). These participants delineated the pre- and postoperative Gross Tumor Volume (GTVpre/post), and Clinical Target Volume (CTV) during two test phases (case 1-2 and 3-4), followed by guideline refinement and a quality assurance phase (case 5-6). Reference target volumes (TVref) were established by three experienced radiation oncologists. The Dice Similarity Coefficient between the reference and participants (DSCref/part) was calculated per case. Delineations of case 5-6 were graded by four independent reviewers as 'per protocol' (0-4 mm), 'minor deviation' (5-9 mm) or 'major deviation' (≥10 mm) from the delineation guideline using 18 standardized criteria. Also, a major deviation resulting in underestimation of the CTVref was regarded as an unacceptable variation. RESULTS: A total of 57/60 delineation sets were completed. The median DSCref/part for the CTV was 0.55 without improvement after sequential cases (case 3-4 vs. case 5-6: p = 0.15). For case 5-6, a major deviation was found for 5/18, 12/17, 18/18 and 4/9 collected delineations of the GTVpre, GTVpost, CTV-T and CTV-N, respectively. An unacceptable variation from the CTVref was found for 7/9 participants for case 5 and 6/9 participants for case 6. CONCLUSION: This international multicenter delineation exercise demonstrates that the new consensus for highly-conformal postoperative flank target volume delineation leads to geometrical variation among participants. Moreover, standardized review showed an unacceptable delineation variation in the majority of the participants. These findings strongly suggest the need for additional training and centralized pre-treatment review when this target volume delineation approach is implemented on a larger scale.

4.
Radiother Oncol ; 156: 62-68, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33310005

RESUMEN

BACKGROUND AND AIMS: Two-opposing photon beams are considered standard of care for flank irradiation in pediatric patients with renal tumors. Nowadays, Image-Guided Radiotherapy (IGRT) techniques allow high-precision dose delivery to complex flank target volumes taking into account postoperative organ shifts and tumor bed motion. This study examines the contribution of a lateral and superior surgical clip on flank target volume delineation intended for IGRT. METHODS: Between 01-2015 and 09-2019, 30/162 newly-diagnosed pediatric patients with renal tumors, lateral/superior surgical clips (n = 30/30) and available 4D-CT-scans (n = 27/30), underwent postoperative flank irradiation. The lateral and superior clip, as respective markers for the lateral tumor extension and intrafraction motion, were analyzed. The positive and negative values depict the lateral/dorsal/cranial or the medial/ventral/caudal direction, respectively. Planning target volumes (PTV) were generated based on lateral clips (PTVlatclip), superior clips with 4D-CT technology (PTVsupclip), and both clips combined (PTVcombined), and compared to an approach without clips (PTVnoclip). RESULTS: Indicated by clips, the mean lateral tumor bed extension along the posterior wall was 74° (range: 50°-93°), while mean intrafraction motion was +1.2 mm (range: -1.8/+4.8 mm), +0.6 mm (range: +0.6/+4.9 mm), -0.3 mm (range: -3.8/+0.7 mm) in craniocaudal, ventrodorsal, mediolateral direction, respectively. The median PTVnoclip (556 mL) was statistically different from the median PTVlatclip (454 mL, p = <0.01), median PTVsupclip (373 mL, p = <0.01) and median PTVcombined (348 mL p = <0.01). CONCLUSION: In pediatric patients with renal tumors, surgical clips at the lateral and superior border of the tumor bed can optimize flank target volume delineation and, consequently, reduce the normal tissue volume receiving high-dose irradiation when IGRT techniques are applied.


Asunto(s)
Neoplasias de la Mama , Neoplasias Renales , Radioterapia Conformacional , Radioterapia Guiada por Imagen , Niño , Tomografía Computarizada Cuatridimensional , Humanos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/radioterapia , Neoplasias Renales/cirugía , Planificación de la Radioterapia Asistida por Computador , Instrumentos Quirúrgicos
5.
Lancet Child Adolesc Health ; 4(11): 846-852, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33068550

RESUMEN

For decades, radiotherapy with two opposing photon beams has been the standard technique used to cover the flank target volume in paediatric patients with renal tumours. Nowadays, many institutes are implementing advanced radiotherapy techniques that spare healthy tissue. To decrease the radiotherapy dose to healthy structures while preserving oncological efficacy, the conventional approach of flank irradiation has been adapted into a guideline for highly conformal flank target-volume delineation by paediatric radiation oncologists and representatives of the International Society of Paediatric Oncology's Renal Tumour Study Group (SIOP-RTSG) board during four live international consensus meetings. The consensus was refined by delineation exercises and videoconferences by ten collaborating paediatric radiation oncologists. The final guideline includes eight chronological steps to generate the tumour bed and clinical, internal, and planning target volumes, and it describes the optional use of surgical clips to optimise treatment planning. This guideline will be added into the radiotherapy guideline of the UMBRELLA SIOP-RTSG protocol for paediatric renal tumours to improve international consistency of highly conformal flank target-volume delineation.


Asunto(s)
Neoplasias Renales/radioterapia , Tratamientos Conservadores del Órgano/métodos , Radioterapia Conformacional , Niño , Consenso , Humanos , Neoplasias Renales/patología , Guías de Práctica Clínica como Asunto , Salud Radiológica , Radioterapia Conformacional/métodos , Radioterapia Conformacional/tendencias
6.
Pediatr Pulmonol ; 55(11): 3168-3179, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32841506

RESUMEN

INTRODUCTION: The simultaneously increased prevalence of atopic diseases and decreased prevalence of infectious diseases might point to a link between the two entities. Past work mainly focused on either atopic diseases or recurrent infections. We aim to investigate whether risk factors for atopic diseases (ie, asthma, allergic rhinitis, atopic dermatitis, and/or food allergy) differ from risk factors for recurrent respiratory tract infections (RRTIs) in children. METHODS: Cross-sectional data were used from 5517 children aged 1 to 18 years who participated in an Electronic Portal for children between 2011 and 2019. Univariable/multivariable logistic regression analyses were performed to determine risk factors for any atopic disease and RRTIs. RESULTS: Children aged ≥5 years were more likely to have any atopic disease (adjusted odds ratio [OR]: 1.50-2.77) and less likely to have RRTIs (OR: 0.68-0.84) compared to children aged less than 5 years. Female sex (OR: 0.72; 95% confidence interval [CI]: 0.63-0.81), low birth weight (OR: 0.74; 95% CI: 0.57-0.97) and dog ownership (OR: 0.79; 95% CI: 0.66-0.95) reduced the odds of any atopic disease, but not of RRTIs. Daycare attendance (OR: 1.22; 95% CI: 1.02-1.47) was associated with RRTIs, but not with atopic diseases. A family history of asthma, allergic rhinitis, atopic dermatitis, and RRTIs was significantly associated with the same entity in children, with OR varying from 1.58 (95% CI: 1.35-1.85) in allergic rhinitis to 2.20 (95% CI: 1.85-2.61) in asthma. CONCLUSION: Risk factors for atopic diseases are distinct from risk factors for RRTIs, suggesting that the changing prevalence of both entities is not related to shared risk factors.


Asunto(s)
Hipersensibilidad/epidemiología , Infecciones del Sistema Respiratorio/epidemiología , Adolescente , Animales , Niño , Preescolar , Centros de Día , Perros , Femenino , Humanos , Lactante , Masculino , Oportunidad Relativa , Mascotas , Prevalencia , Recurrencia , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...