Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Eur J Radiol ; 83(7): 1209-1215, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24840478

RESUMEN

OBJECTIVE: To compare performance of single-injection blood pool agent (gadofosveset trisodium, BPA) against dual-injection extracellular contrast (gadopentetate dimeglumine, ECA) for MRA/MRV in assessment of suspected vascular TOS. MATERIALS AND METHODS: Thirty-one patients referred for vascular TOS evaluation were assessed with BPA (n=18) or ECA (n=13) MRA/MRV in arm abduction and adduction. Images were retrospectively assessed for: image quality (1=non-diagnostic, 5=excellent), vessel contrast (1=same signal as muscle, 4=much brighter than muscle) and vascular pathology by two independent readers, with a separate experienced reader providing reference assessment of vascular pathology. RESULTS: Median image quality was diagnostic or better (score ≥ 3) for ECA and BPA at all time points, with BPA image quality superior at abduction late (BPA 4.5, ECA 4, p=0.042) and ECA image quality superior at adduction-early (BPA 4.5; ECA 4.0, p=0.018). High qualitative vessel contrast (mean score ≥ 3) was observed at all time points with both BPA and ECA, with superior BPA vessel contrast at abduction-late (BPA 3.97 ± 0.12; ECA 3.73 ± 0.26, p=0.007) and ECA at adduction-early (BPA 3.42 ± 0.52; ECA 3.96 ± 0.14, p<0.001). Readers readily identified arterial and venous pathology with BPA, similar to ECA examinations. CONCLUSION: Single-injection BPA MRA/MRV for TOS evaluation demonstrated diagnostic image quality and high vessel contrast, similar to dual-injection ECA imaging, enabling identification of fixed and functional arterial and venous pathology.


Asunto(s)
Gadolinio DTPA , Gadolinio , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Compuestos Organometálicos , Síndrome del Desfiladero Torácico/patología , Adolescente , Adulto , Anciano , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
2.
AJR Am J Roentgenol ; 200(6): 1378-86, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23701079

RESUMEN

OBJECTIVE: The purpose of this review is to illustrate various applications of gadofosveset trisodium in evaluating abdominal and peripheral vascular disease. The basic properties, technical considerations, and clinical and potential future applications of gadofosveset are described. CONCLUSION: Gadofosveset trisodium facilitates comprehensive high-resolution arterial and venous MR angiography. Because of its prolonged intravascular residence time, gadofosveset trisodium is particularly useful for evaluating venous, dynamic, and functional vascular disease with a single low-dose contrast injection.


Asunto(s)
Abdomen/irrigación sanguínea , Medios de Contraste , Gadolinio , Angiografía por Resonancia Magnética , Compuestos Organometálicos , Enfermedades Vasculares Periféricas/diagnóstico , Humanos
3.
Skeletal Radiol ; 42(3): 347-52, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22829026

RESUMEN

OBJECTIVE: To create 3DMR osseous models of the shoulder similar to 3DCT models using a gradient-echo-based two-point/Dixon sequence. MATERIALS AND METHODS: CT and 3TMR examinations of 7 cadaveric shoulders were obtained. Glenoid defects were created in 4 of the cadaveric shoulders. Each MR study included an axial Dixon 3D-dual-echo-time T1W-FLASH (acquisition time of 3 min/30 s). The water-only image data from the Dixon sequence and CT data were post-processed using 3D software. The following measurements were obtained on the shoulders: surface area (SA), height/width of the glenoid and humeral head, and width of the biceps groove. The glenoid defects were measured on imaging and compared with measurements made on en face digital photographs of the glenoid fossae (reference standard). Paired t tests/ANOVA were used to assess the differences between the imaging modalities. RESULTS: The differences between the glenoid and humeral measurements were not statistically significant (cm): glenoid SA 0.12 ± 0.04 (p = 0.45) and glenoid width 0.13 ± 0.06 (p = 0.06) with no difference in glenoid height measurement; humeral head SA 0.07 ± 0.12 (p = 0.42), humeral head height 0.03 ± 0.06 (p = 0.42), humeral head width 0.07 ± 0.06(p = 0.18), and biceps groove width 0.02 ± 0.01 (p = 0.07). The mean/standard deviation difference between the reference standard and 3DMR measurements was 0.25 ± 0.96 %/0.30 ± 0.14 mm; 3DCT 0.25 ± 0.96 /0.75 ± 0.39 mm. There was no statistical difference between the measurements obtained on 3DMR and 3DCT (percentage, p = 0.45; mm, p = 0.20). CONCLUSION: Accurate 3D osseous models of the shoulder can be produced using a 3D two-point/Dixon sequence and can be added to MR examinations with a minor increase in imaging time, used to quantify glenoid loss, and may eliminate the need for pre-surgical CT examinations.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Procedimientos de Cirugía Plástica/métodos , Articulación del Hombro/patología , Articulación del Hombro/cirugía , Cirugía Asistida por Computador/métodos , Algoritmos , Cadáver , Estudios de Factibilidad , Femenino , Humanos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Laryngoscope ; 122(4): 860-4, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22253090

RESUMEN

OBJECTIVES/HYPOTHESIS: In this article we describe a methodology for obtaining high-quality dynamic magnetic resonance imaging (MRI) sequences of the swallow sequence in healthy volunteers. The study includes comparison to previous work done in our lab using a 1.5 Tesla (T) magnet. STUDY DESIGN: Case series. METHODS: Three healthy volunteers underwent turbo-fast low angle shot MRI at 3T while swallowing liquid boluses delivered via intravenous tubing to the oral cavity. Imaging was performed in the sagittal and axial planes. RESULTS: Imaging provided by this sequence provided high temporal resolution, with the ability to depict deglutition in the axial and sagittal planes. Comparison with imaging at 1.5 T demonstrated benefits in temporal resolution and signal-to-noise. Anatomic information provided differed from comparative videofluoroscopy. CONCLUSIONS: MRI of swallowing using the described technique is reliable and provides a unique evaluation of the swallowing sequence.


Asunto(s)
Deglución/fisiología , Imagen por Resonancia Magnética/métodos , Faringe/fisiología , Adulto , Femenino , Humanos , Masculino , Valores de Referencia , Reproducibilidad de los Resultados
6.
Int J Psychophysiol ; 56(2): 143-55, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15804449

RESUMEN

EEG feedback methods, which link the occurrence of alpha to the presentation of repeated visual stimuli, reduce the relative variability of subsequent, alpha-blocking event durations. The temporal association between electro-cortical field activation and regional cerebral blood flow (rCBF) led us to investigate whether the reduced variability of alpha-blocking durations with feedback is associated with a reduction in rCBF variability. Reduced variability in the rCBF response domain under EEG feedback control might have methodological implications for future brain-imaging studies. Visual stimuli were randomly presented to seven subjects, contingent upon the occurrence of alpha (alpha-contingent stimulation (ACS)) or alpha-blocking (not-alpha-blocking-contingent stimulation (NACS)) events. We employed a within-subjects design. rCBF was measured from multiple, cortical and sub-cortical regions. The primary dependent variables were the Mean, Standard Deviation and the ratio of Mean/Standard Deviation of: 1) the alpha-blocking response durations and 2) the temporally summated rCBF responses within the Visual Associative regions of interest (ROIs). Additional within-subjects rCBF measures were derived to quantify the variance-reducing effects of ACS across multiple, distributed areas of the brain. Both EEG and rCBF measures demonstrated decreased variability under ACS. This improved control was seen for localized as well as anatomically distributed rCBF measures.


Asunto(s)
Ritmo alfa , Biorretroalimentación Psicológica , Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Circulación Cerebrovascular/fisiología , Electroencefalografía , Adulto , Calibración , Dióxido de Carbono/metabolismo , Femenino , Humanos , Masculino , Estimulación Luminosa , Tomografía Computarizada de Emisión de Fotón Único , Radioisótopos de Xenón
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...