Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
2.
J Integr Neurosci ; 18(3): 217-229, 2019 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-31601069

RESUMEN

In the electroencephalogram recorded data are often confounded with artifacts, especially in the case of eye blinks. Different methods for artifact detection and removal are discussed in the literature, including automatic detection and removal. Here, an automatic method of eye blink detection and correction is proposed where sparse coding is used for an electroencephalogram dataset. In this method, a hybrid dictionary based on a ridgelet transformation is used to capture prominent features by analyzing independent components extracted from a different number of electroencephalogram channels. In this study, the proposed method has been tested and validated with five different datasets for artifact detection and correction. Results show that the proposed technique is promising as it successfully extracted the exact locations of eye blinking artifacts. The accuracy of the method (automatic detection) is 89.6% which represents a better estimate than that obtained by an extreme machine learning classifier.


Asunto(s)
Artefactos , Parpadeo , Electroencefalografía/métodos , Procesamiento de Señales Asistido por Computador , Adulto , Algoritmos , Trastorno Depresivo Mayor/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad
3.
Int J Med Inform ; 132: 103983, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31586827

RESUMEN

BACKGROUND AND PURPOSE: In recent years, the development of machine learning (ML) frameworks for automatic diagnosis of unipolar depression has escalated to a next level of deep learning frameworks. However, this idea needs further validation. Therefore, this paper has proposed an electroencephalographic (EEG)-based deep learning framework that automatically discriminated depressed and healthy controls and provided the diagnosis. BASIC PROCEDURES: In this paper, two different deep learning architectures were proposed that utilized one dimensional convolutional neural network (1DCNN) and 1DCNN with long short-term memory (LSTM) architecture. The proposed deep learning architectures automatically learn patterns in the EEG data that were useful for classifying the depressed and healthy controls. In addition, the proposed models were validated with resting-state EEG data obtained from 33 depressed patients and 30 healthy controls. MAIN FINDINGS: As results, significant differences were observed between the two groups. The classification results involving the CNN model were accuracy = 98.32%, precision = 99.78%, recall = 98.34%, and f-score = 97.65%. In addition, the study has reported LSTM with 1DCNN classification accuracy = 95.97%, precision = 99.23%, recall = 93.67%, and f-score = 95.14%. CONCLUSIONS: Deep learning frameworks could revolutionize the clinical applications for EEG-based diagnosis for depression. Based on the results, it may be concluded that the deep learning framework could be used as an automatic method for diagnosing the depression.


Asunto(s)
Aprendizaje Profundo , Trastorno Depresivo/diagnóstico , Redes Neurales de la Computación , Adulto , Automatización , Estudios de Casos y Controles , Electroencefalografía , Femenino , Humanos , Masculino
4.
Brain Topogr ; 31(5): 875-885, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29860588

RESUMEN

The choice of an electroencephalogram (EEG) reference has fundamental importance and could be critical during clinical decision-making because an impure EEG reference could falsify the clinical measurements and subsequent inferences. In this research, the suitability of three EEG references was compared while classifying depressed and healthy brains using a machine-learning (ML)-based validation method. In this research, the EEG data of 30 unipolar depressed subjects and 30 age-matched healthy controls were recorded. The EEG data were analyzed in three different EEG references, the link-ear reference (LE), average reference (AR), and reference electrode standardization technique (REST). The EEG-based functional connectivity (FC) was computed. Also, the graph-based measures, such as the distances between nodes, minimum spanning tree, and maximum flow between the nodes for each channel pair, were calculated. An ML scheme provided a mechanism to compare the performances of the extracted features that involved a general framework such as the feature extraction (graph-based theoretic measures), feature selection, classification, and validation. For comparison purposes, the performance metrics such as the classification accuracies, sensitivities, specificities, and F scores were computed. When comparing the three references, the diagnostic accuracy showed better performances during the REST, while the LE and AR showed less discrimination between the two groups. Based on the results, it can be concluded that the choice of appropriate reference is critical during the clinical scenario. The REST reference is recommended for future applications of EEG-based diagnosis of mental illnesses.


Asunto(s)
Depresión/diagnóstico , Electroencefalografía/métodos , Adulto , Anciano , Algoritmos , Depresión/clasificación , Depresión/psicología , Electroencefalografía/clasificación , Electroencefalografía/estadística & datos numéricos , Femenino , Humanos , Aprendizaje Automático , Masculino , Persona de Mediana Edad , Vías Nerviosas/fisiopatología , Valores de Referencia , Reproducibilidad de los Resultados
5.
Cogn Neurodyn ; 12(2): 141-156, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29564024

RESUMEN

The screening test for alcohol use disorder (AUD) patients has been of subjective nature and could be misleading in particular cases such as a misreporting the actual quantity of alcohol intake. Although the neuroimaging modality such as electroencephalography (EEG) has shown promising research results in achieving objectivity during the screening and diagnosis of AUD patients. However, the translation of these findings for clinical applications has been largely understudied and hence less clear. This study advocates the use of EEG as a diagnostic and screening tool for AUD patients that may help the clinicians during clinical decision making. In this context, a comprehensive review on EEG-based methods is provided including related electrophysiological techniques reported in the literature. More specifically, the EEG abnormalities associated with the conditions of AUD patients are summarized. The aim is to explore the potentials of objective techniques involving quantities/features derived from resting EEG, event-related potentials or event-related oscillations data.

6.
Artif Intell Med ; 84: 79-89, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29169647

RESUMEN

BACKGROUND: The abnormal alcohol consumption could cause toxicity and could alter the human brain's structure and function, termed as alcohol used disorder (AUD). Unfortunately, the conventional screening methods for AUD patients are subjective and manual. Hence, to perform automatic screening of AUD patients, objective methods are needed. The electroencephalographic (EEG) data have been utilized to study the differences of brain signals between alcoholics and healthy controls that could further developed as an automatic screening tool for alcoholics. METHOD: In this work, resting-state EEG-derived features were utilized as input data to the proposed feature selection and classification method. The aim was to perform automatic classification of AUD patients and healthy controls. The validation of the proposed method involved real-EEG data acquired from 30 AUD patients and 30 age-matched healthy controls. The resting-state EEG-derived features such as synchronization likelihood (SL) were computed involving 19 scalp locations resulted into 513 features. Furthermore, the features were rank-ordered to select the most discriminant features involving a rank-based feature selection method according to a criterion, i.e., receiver operating characteristics (ROC). Consequently, a reduced set of most discriminant features was identified and utilized further during classification of AUD patients and healthy controls. In this study, three different classification models such as Support Vector Machine (SVM), Naïve Bayesian (NB), and Logistic Regression (LR) were used. RESULTS: The study resulted into SVM classification accuracy=98%, sensitivity=99.9%, specificity=95%, and f-measure=0.97; LR classification accuracy=91.7%, sensitivity=86.66%, specificity=96.6%, and f-measure=0.90; NB classification accuracy=93.6%, sensitivity=100%, specificity=87.9%, and f-measure=0.95. CONCLUSION: The SL features could be utilized as objective markers to screen the AUD patients and healthy controls.


Asunto(s)
Alcoholismo/diagnóstico , Ondas Encefálicas , Encéfalo/fisiopatología , Diagnóstico por Computador/métodos , Electroencefalografía/métodos , Procesamiento de Señales Asistido por Computador , Máquina de Vectores de Soporte , Adulto , Anciano , Alcoholismo/fisiopatología , Área Bajo la Curva , Automatización , Teorema de Bayes , Estudios de Casos y Controles , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Reproducibilidad de los Resultados
7.
Med Biol Eng Comput ; 56(2): 233-246, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28702811

RESUMEN

Major depressive disorder (MDD), a debilitating mental illness, could cause functional disabilities and could become a social problem. An accurate and early diagnosis for depression could become challenging. This paper proposed a machine learning framework involving EEG-derived synchronization likelihood (SL) features as input data for automatic diagnosis of MDD. It was hypothesized that EEG-based SL features could discriminate MDD patients and healthy controls with an acceptable accuracy better than measures such as interhemispheric coherence and mutual information. In this work, classification models such as support vector machine (SVM), logistic regression (LR) and Naïve Bayesian (NB) were employed to model relationship between the EEG features and the study groups (MDD patient and healthy controls) and ultimately achieved discrimination of study participants. The results indicated that the classification rates were better than chance. More specifically, the study resulted into SVM classification accuracy = 98%, sensitivity = 99.9%, specificity = 95% and f-measure = 0.97; LR classification accuracy = 91.7%, sensitivity = 86.66%, specificity = 96.6% and f-measure = 0.90; NB classification accuracy = 93.6%, sensitivity = 100%, specificity = 87.9% and f-measure = 0.95. In conclusion, SL could be a promising method for diagnosing depression. The findings could be generalized to develop a robust CAD-based tool that may help for clinical purposes.


Asunto(s)
Trastorno Depresivo Mayor/diagnóstico , Electroencefalografía , Máquina de Vectores de Soporte , Adulto , Teorema de Bayes , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Modelos Teóricos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Encuestas y Cuestionarios , Adulto Joven
8.
Front Comput Neurosci ; 11: 103, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29209190

RESUMEN

Feature extraction is an important step in the process of electroencephalogram (EEG) signal classification. The authors propose a "pattern recognition" approach that discriminates EEG signals recorded during different cognitive conditions. Wavelet based feature extraction such as, multi-resolution decompositions into detailed and approximate coefficients as well as relative wavelet energy were computed. Extracted relative wavelet energy features were normalized to zero mean and unit variance and then optimized using Fisher's discriminant ratio (FDR) and principal component analysis (PCA). A high density EEG dataset validated the proposed method (128-channels) by identifying two classifications: (1) EEG signals recorded during complex cognitive tasks using Raven's Advance Progressive Metric (RAPM) test; (2) EEG signals recorded during a baseline task (eyes open). Classifiers such as, K-nearest neighbors (KNN), Support Vector Machine (SVM), Multi-layer Perceptron (MLP), and Naïve Bayes (NB) were then employed. Outcomes yielded 99.11% accuracy via SVM classifier for coefficient approximations (A5) of low frequencies ranging from 0 to 3.90 Hz. Accuracy rates for detailed coefficients were 98.57 and 98.39% for SVM and KNN, respectively; and for detailed coefficients (D5) deriving from the sub-band range (3.90-7.81 Hz). Accuracy rates for MLP and NB classifiers were comparable at 97.11-89.63% and 91.60-81.07% for A5 and D5 coefficients, respectively. In addition, the proposed approach was also applied on public dataset for classification of two cognitive tasks and achieved comparable classification results, i.e., 93.33% accuracy with KNN. The proposed scheme yielded significantly higher classification performances using machine learning classifiers compared to extant quantitative feature extraction. These results suggest the proposed feature extraction method reliably classifies EEG signals recorded during cognitive tasks with a higher degree of accuracy.

9.
Cogn Neurodyn ; 11(2): 161-171, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28348647

RESUMEN

Screening alcohol use disorder (AUD) patients has been challenging due to the subjectivity involved in the process. Hence, robust and objective methods are needed to automate the screening of AUD patients. In this paper, a machine learning method is proposed that utilized resting-state electroencephalography (EEG)-derived features as input data to classify the AUD patients and healthy controls and to perform automatic screening of AUD patients. In this context, the EEG data were recorded during 5 min of eyes closed and 5 min of eyes open conditions. For this purpose, 30 AUD patients and 15 aged-matched healthy controls were recruited. After preprocessing the EEG data, EEG features such as inter-hemispheric coherences and spectral power for EEG delta, theta, alpha, beta and gamma bands were computed involving 19 scalp locations. The selection of most discriminant features was performed with a rank-based feature selection method assigning a weight value to each feature according to a criterion, i.e., receiver operating characteristics curve. For example, a feature with large weight was considered more relevant to the target labels than a feature with less weight. Therefore, a reduced set of most discriminant features was identified and further be utilized during classification of AUD patients and healthy controls. As results, the inter-hemispheric coherences between the brain regions were found significantly different between the study groups and provided high classification efficiency (Accuracy = 80.8, sensitivity = 82.5, and specificity = 80, F-Measure = 0.78). In addition, the power computed in different EEG bands were found significant and provided an overall classification efficiency as (Accuracy = 86.6, sensitivity = 95, specificity = 82.5, and F-Measure = 0.88). Further, the integration of these EEG feature resulted into even higher results (Accuracy = 89.3 %, sensitivity = 88.5 %, specificity = 91 %, and F-Measure = 0.90). Based on the results, it is concluded that the EEG data (integration of the theta, beta, and gamma power and inter-hemispheric coherence) could be utilized as objective markers to screen the AUD patients and healthy controls.

10.
PLoS One ; 12(2): e0171409, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28152063

RESUMEN

Treatment management for Major Depressive Disorder (MDD) has been challenging. However, electroencephalogram (EEG)-based predictions of antidepressant's treatment outcome may help during antidepressant's selection and ultimately improve the quality of life for MDD patients. In this study, a machine learning (ML) method involving pretreatment EEG data was proposed to perform such predictions for Selective Serotonin Reuptake Inhibitor (SSRIs). For this purpose, the acquisition of experimental data involved 34 MDD patients and 30 healthy controls. Consequently, a feature matrix was constructed involving time-frequency decomposition of EEG data based on wavelet transform (WT) analysis, termed as EEG data matrix. However, the resultant EEG data matrix had high dimensionality. Therefore, dimension reduction was performed based on a rank-based feature selection method according to a criterion, i.e., receiver operating characteristic (ROC). As a result, the most significant features were identified and further be utilized during the training and testing of a classification model, i.e., the logistic regression (LR) classifier. Finally, the LR model was validated with 100 iterations of 10-fold cross-validation (10-CV). The classification results were compared with short-time Fourier transform (STFT) analysis, and empirical mode decompositions (EMD). The wavelet features extracted from frontal and temporal EEG data were found statistically significant. In comparison with other time-frequency approaches such as the STFT and EMD, the WT analysis has shown highest classification accuracy, i.e., accuracy = 87.5%, sensitivity = 95%, and specificity = 80%. In conclusion, significant wavelet coefficients extracted from frontal and temporal pre-treatment EEG data involving delta and theta frequency bands may predict antidepressant's treatment outcome for the MDD patients.


Asunto(s)
Trastorno Depresivo Mayor/tratamiento farmacológico , Electroencefalografía , Adulto , Antidepresivos/uso terapéutico , Encéfalo/fisiopatología , Trastorno Depresivo Mayor/fisiopatología , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Inhibidores Selectivos de la Recaptación de Serotonina/uso terapéutico , Resultado del Tratamiento
11.
Artículo en Inglés | MEDLINE | ID: mdl-26737211

RESUMEN

Clinical utility of Electroencephalography (EEG) based diagnostic studies is less clear for major depressive disorder (MDD). In this paper, a novel machine learning (ML) scheme was presented to discriminate the MDD patients and healthy controls. The proposed method inherently involved feature extraction, selection, classification and validation. The EEG data acquisition involved eyes closed (EC) and eyes open (EO) conditions. At feature extraction stage, the de-trended fluctuation analysis (DFA) was performed, based on the EEG data, to achieve scaling exponents. The DFA was performed to analyzes the presence or absence of long-range temporal correlations (LRTC) in the recorded EEG data. The scaling exponents were used as input features to our proposed system. At feature selection stage, 3 different techniques were used for comparison purposes. Logistic regression (LR) classifier was employed. The method was validated by a 10-fold cross-validation. As results, we have observed that the effect of 3 different reference montages on the computed features. The proposed method employed 3 different types of feature selection techniques for comparison purposes as well. The results show that the DFA analysis performed better in LE data compared with the IR and AR data. In addition, during Wilcoxon ranking, the AR performed better than LE and IR. Based on the results, it was concluded that the DFA provided useful information to discriminate the MDD patients and with further validation can be employed in clinics for diagnosis of MDD.


Asunto(s)
Trastorno Depresivo Mayor/diagnóstico , Electroencefalografía/métodos , Procesamiento de Señales Asistido por Computador , Adulto , Estudios de Casos y Controles , Trastorno Depresivo Mayor/fisiopatología , Ojo , Femenino , Humanos , Modelos Logísticos , Aprendizaje Automático , Persona de Mediana Edad , Reproducibilidad de los Resultados
12.
Artículo en Inglés | MEDLINE | ID: mdl-26738049

RESUMEN

Visual and mental fatigues induced by active shutter stereoscopic 3D (S3D) display have been reported using event-related brain potentials (ERP). An important question, that is whether such effects (visual & mental fatigues) can be found in passive polarized S3D display, is answered here. Sixty-eight healthy participants are divided into 2D and S3D groups and subjected to an oddball paradigm after being exposed to S3D videos with passive polarized display or 2D display. The age and fluid intelligence ability of the participants are controlled between the groups. ERP results do not show any significant differences between S3D and 2D groups to find the aftereffects of S3D in terms of visual and mental fatigues. Hence, we conclude that passive polarized S3D display technology may not induce visual and/or mental fatigue which may increase the cognitive load and suppress the ERP components.


Asunto(s)
Astenopía/diagnóstico , Percepción de Profundidad , Imagenología Tridimensional/métodos , Fatiga Mental/diagnóstico , Adolescente , Adulto , Potenciales Evocados , Femenino , Humanos , Masculino , Estimulación Luminosa , Tiempo de Reacción , Análisis y Desempeño de Tareas , Factores de Tiempo , Adulto Joven
13.
Artículo en Inglés | MEDLINE | ID: mdl-24110125

RESUMEN

Video games have long been part of the entertainment industry. Nonetheless, it is not well known how video games can affect us with the advancement of 3D technology. The purpose of this study is to investigate the EEG signals regularity when playing video games in 2D and 3D modes. A total of 29 healthy subjects (24 male, 5 female) with mean age of 21.79 (1.63) years participated. Subjects were asked to play a car racing video game in three different modes (2D, 3D passive and 3D active). In 3D passive mode, subjects needed to wear a passive polarized glasses (cinema type) while for 3D active, an active shutter glasses was used. Scalp EEG data was recorded during game play using 19-channel EEG machine and linked ear was used as reference. After data were pre-processed, the signal irregularity for all conditions was computed. Two parameters were used to measure signal complexity for time series data: i) Hjorth-Complexity and ii) Composite Permutation Entropy Index (CPEI). Based on these two parameters, our results showed that the complexity level increased from eyes closed to eyes open condition; and further increased in the case of 3D as compared to 2D game play.


Asunto(s)
Encéfalo/fisiología , Electroencefalografía/métodos , Juegos de Video , Adulto , Entropía , Femenino , Voluntarios Sanos , Humanos , Masculino , Procesamiento de Señales Asistido por Computador , Adulto Joven
14.
Artículo en Inglés | MEDLINE | ID: mdl-24110667

RESUMEN

Higher classification accuracy is more desirable for brain computer interface (BCI) applications. The accuracy can be achieved by appropriate selection of relevant features. In this paper a new scheme is proposed based on six different nonlinear features. These features include Sample entropy (SampEn), Composite permutation entropy index (CPEI), Approximate entropy (ApEn), Fractal dimension (FD), Hurst exponent (H) and Hjorth parameters (complexity and mobility). These features are decision variables for classification of physiological conditions: Eyes Open (EO), Eyes Closed (EC), Game Playing 2D (GP2D), Game playing 3D active (GP3DA) and Game playing 3D passive (GP3DP). Results show that the scheme can successfully classify the conditions with an accuracy of 88.9%.


Asunto(s)
Electroencefalografía , Redes Neurales de la Computación , Procesamiento de Señales Asistido por Computador , Interfaces Cerebro-Computador , Entropía , Ambiente , Fractales , Humanos , Lenguaje , Juegos de Video
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...