Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Med Syst ; 45(3): 27, 2021 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-33469726

RESUMEN

The feasibility of rendering three dimensional (3D) pelvic models of vaginal, urethral and paraurethral lesions from 2D MRI has been demonstrated previously. To quantitatively compare 3D models using two different image processing applications: 3D Slicer and OsiriX. Secondary analysis and processing of five MRI scan based image sets from female patients aged 29-43 years old with vaginal or paraurethral lesions. Cross sectional image sets were used to create 3D models of the pelvic structures with 3D Slicer and OsiriX image processing applications. The linear dimensions of the models created using the two different methods were compared using Bland-Altman plots. The comparisons demonstrated good agreement between measurements from the two applications. The two data sets obtained from different image processing methods demonstrated good agreement. Both 3D Slicer and OsiriX can be used interchangeably and produce almost similar results. The clinical role of this investigation modality remains to be further evaluated.


Asunto(s)
Imagen por Resonancia Magnética , Pelvis , Abdomen , Estudios Transversales , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Pelvis/diagnóstico por imagen
2.
Cardiovasc Intervent Radiol ; 36(1): 35-45, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22833173

RESUMEN

Major concerns after aortic aneurysm repair are caused by the presence of endoleaks, which are defined as persistent perigraft flow within the aortic aneurysm sac. Diagnosis of endoleaks can be performed with various imaging modalities, and indications for treatment are based on further subclassifications. Early detection and correct classification of endoleaks are crucial for planning patient management. The vast majority of endoleaks can be treated successfully by interventional means. Guidelines for Imaging Detection and Treatment of endoleaks are described in this article.


Asunto(s)
Aneurisma de la Aorta/cirugía , Diagnóstico por Imagen/métodos , Endofuga/diagnóstico , Procedimientos Endovasculares/efectos adversos , Guías de Práctica Clínica como Asunto , Intensificación de Imagen Radiográfica , Angiografía/métodos , Aneurisma de la Aorta/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Medios de Contraste , Diagnóstico por Imagen/normas , Diagnóstico Precoz , Endofuga/terapia , Procedimientos Endovasculares/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Medición de Riesgo , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía Doppler Dúplex/métodos
3.
Clin Radiol ; 67(10): 949-54, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22947210

RESUMEN

AIM: To analyse lower limb angioplasty results using the defined anatomical classification of the Trans-Atlantic Inter-Society Consensus (TASC) in a training environment and to compare the results with published data. MATERIALS AND METHODS: Retrospective, consecutive data were collected for a period of 1 year for all patients undergoing lower limb endovascular interventions. The radiology information system and notes were used to obtain clinical data, and angiograms were reviewed in all cases. All cases were performed or supervised by five vascular interventional consultants assisted by fellows or registrars. Patient demographics, the indication for treatment, the TASC classification of the treated lesion, calcification, use of stent, technical success (residual stenosis <20% on completion angiography), and complications were assessed. RESULTS: Two hundred and sixty-two lesions were treated. Of the aortoiliac lesions (83), the overall primary technical success rate was 91.6% (TASC A and B: 96.7%, TASC C and D: 77.3%). Sixty-one lesions were stented and no complications recorded. Of the femoropopliteal lesions (n = 123), the overall primary technical success rate was 91.9% (TASC A and B: 98.7%, TASC C and D: 80.9%). There were four major and five minor complications in this group (five groin haematomas, two vessel ruptures, one retroperitoneal haematoma, and one distal embolization). Five patients were stented. In the infrapopliteal group (n = 56), the overall primary technical success rate was 91.1% (TASC A and B: 96.3%, TASC C and D: 86.2%). There was one complication (small retroperitoneal hematoma) and two stents were used. CONCLUSION: The results of the present study showed good technical success and low complication rates in lower limb endovascular interventions with variable operator expertise. The results are comparable to published data. Use of the TASC classification system is encouraged as it allows an objective assessment of severity and enables standardized comparison.


Asunto(s)
Angioplastia/estadística & datos numéricos , Enfermedad Arterial Periférica/epidemiología , Enfermedad Arterial Periférica/cirugía , Complicaciones Posoperatorias/epidemiología , Humanos , Pierna/irrigación sanguínea , Pierna/cirugía , Enfermedad Arterial Periférica/diagnóstico por imagen , Prevalencia , Radiografía , Factores de Riesgo , Resultado del Tratamiento , Reino Unido/epidemiología
4.
Cardiovasc Intervent Radiol ; 35(2): 309-15, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21643866

RESUMEN

PURPOSE: Successful IVC filter retrieval rates fall with time. Serious complications have been reported following attempts to remove filters after 3-18 months. Failed retrieval may be associated with adverse clinical sequelae. This study explored whether retrieval rates are improved if interventional radiologists organize patient follow-up, rather than relying on the referring clinicians. METHODS: Proactive follow-up of patients who undergo filter placement was implemented in May 2008. At the time of filter placement, a report was issued to the referring consultant notifying them of the advised timeframe for filter retrieval. Clinicians were contacted to arrange retrieval within 30 days. We compared this with our practice for the preceding year. RESULTS: The numbers of filters inserted during the two time periods was similar, as were the numbers of retrieval attempts and the time scale at which they occurred. The rate of successful retrievals increased but not significantly. The major changes were better documentation of filter types and better clinical follow-up. After the change in practice, only one patient was lost to follow-up compared with six the preceding year. CONCLUSIONS: Although there was no significant improvement in retrieval rates, the proactive, radiology-led approach improved follow-up and documentation, ensuring that a clinical decision was made about how long the filter was required and whether retrieval should be attempted and ensuring that patients were not lost to follow-up.


Asunto(s)
Remoción de Dispositivos/estadística & datos numéricos , Pautas de la Práctica en Medicina/organización & administración , Radiografía Intervencional/métodos , Filtros de Vena Cava , Vena Cava Inferior/diagnóstico por imagen , Anticoagulantes , Contraindicaciones , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Derivación y Consulta/estadística & datos numéricos , Proyectos de Investigación/estadística & datos numéricos , Tomografía Computarizada por Rayos X , Tromboembolia Venosa/prevención & control
6.
Cardiovasc Intervent Radiol ; 31(3): 504-8, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18214596

RESUMEN

Patients who undergo endovascular repair of aorto-iliac aneurysms (EVAR) require internal iliac artery (IIA) embolization (IIAE) to prevent type II endoleaks after extending the endografts into the external iliac artery. However, IIAE may not be possible in some patients due to technical factors or adverse anatomy. The aim of this study was to assess retrospectively whether patients with aorto-iliac aneurysms who fail IIAE have an increase in type II endoleak after EVAR compared with similar patients who undergo successful embolization. We retrospectively analyzed the records of 148 patients who underwent EVAR from December 1997 to June 2005. Sixty-one patients had aorto-iliac aneurysms which required IIAE before EVAR. Fifty patients had successful IIAE and 11 patients had unsuccessful IIAE prior to EVAR. The clinical and imaging follow-up was reviewed before and after EVAR. The endoleak rate of the embolized group was compared with that of the group in whom embolization failed. After a mean follow-up of 19.7 months in the study group and 25 months in the control group, there were no statistically significant differences in outcome measures between the two groups. Specifically, there were no type II endoleaks related to the IIA in patients where IIAE had failed. We conclude that failure to embolize the IIA prior to EVAR should not necessarily preclude patients from treatment. In patients where there is difficulty in achieving coil embolization, it is recommended that EVAR should proceed, as clinical sequelae are unlikely.


Asunto(s)
Angioplastia/métodos , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/métodos , Embolización Terapéutica/métodos , Aneurisma Ilíaco/terapia , Arteria Ilíaca/diagnóstico por imagen , Anciano , Angiografía/métodos , Angioplastia/mortalidad , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Aneurisma Ilíaco/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/prevención & control , Cuidados Preoperatorios/métodos , Falla de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Stents , Tasa de Supervivencia , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
7.
Cardiovasc Intervent Radiol ; 31(2): 246-53, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-17957407

RESUMEN

PURPOSE: To assess the outcomes of patients after bilateral internal iliac artery (IIA) embolization prior to endovascular aneurysm repair (EVAR). METHODS: Thirty-nine patients (age range 55-88 years, mean 72.5 years; 2 women) underwent IIA embolization/occlusion before EVAR. There were 28 patients with aorto-biiliac aneurysms and 6 with bilateral common iliac artery (CIA) aneurysms. Five patients with unilateral CIA aneurysms had previous surgical ligation of the contralateral IIA or inadvertent covering by the stent-graft of the contralateral IIA origin. Outcomes were assessed by clinical follow-up. RESULTS: Severe ischemic complications were limited to spinal cord ischemia in 1 patient (3%) who developed paraparesis following EVAR. No other severe ischemic complications such as buttock necrosis, or bowel or bladder ischemia, occurred. Buttock and/or thigh claudication occurred in 12 patients (31%) and persisted beyond 1 year in 3 patients (9%). Sexual dysfunction occurred in 2 patients (5%). Patients who underwent simultaneous embolization had a 25% (3/12) ischemic complication rate versus 41% (11/27) in those with sequential embolization (p = 0.48). Embolization limited to the main trunk of the IIA resulted in a significantly reduced ischemic complication rate of 16% (3/19) versus 55% (11/20) of patients who had a more distal embolization of the IIA (p = 0.019, Fisher's exact test). CONCLUSION: Severe complications after bilateral IIA embolization are uncommon. Although buttock/thigh claudication occurs in around 30% of patients soon after the procedure, this resolves in the majority after 1 year. There is no obvious benefit for sequential versus simultaneous IIA embolization in our series. Occlusion of the proximal IIA trunk is associated with reduced complications compared with occlusion of the distal IIA.


Asunto(s)
Aneurisma de la Aorta Abdominal/terapia , Arteriopatías Oclusivas/terapia , Embolización Terapéutica/métodos , Aneurisma Ilíaco/terapia , Anciano , Anciano de 80 o más Años , Angiografía , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Arteriopatías Oclusivas/complicaciones , Arteriopatías Oclusivas/diagnóstico por imagen , Implantación de Prótesis Vascular , Femenino , Humanos , Aneurisma Ilíaco/complicaciones , Aneurisma Ilíaco/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Radiografía Intervencional , Stents , Resultado del Tratamiento
8.
Cardiovasc Intervent Radiol ; 30(6): 1139-43, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17874163

RESUMEN

The purpose of this study was to assess the effect of elective bilateral femoral arterial punctures for uterine artery embolization (UAE) of symptomatic fibroids on fluoroscopy and procedural time, patient dose, and ease of procedure. We conducted a prospective study of UAE with either the intention to catheterize both uterine arteries using a single femoral puncture (n = 12) or elective bilateral arterial punctures from the outset (n = 12). The same two operators undertook each case. Main outcome measures were total procedure time, fluoroscopy time, dose-area product (DAP), and total skin dose. A simulation was then performed on an anthropomorphic phantom using the mean in vivo fluoroscopy parameters to estimate the ovarian dose. Bilateral UAE was achieved in all patients. None of the patients with initial unilateral arterial puncture required further contralateral arterial puncture. The mean fluoroscopy time in the group with elective bilateral punctures was 12.8 min, compared with a mean of 16.6 min in patients with unilateral puncture (p = 0.046). There was no significant difference in overall procedure time (p = 0.68). No puncture-site complications were found. Additional catheters were required only following unilateral puncture. The simulated dose was 25% higher with unilateral puncture. Although there was no significant difference in measured in vivo patient dose between the two groups (DAP, p = 0.32), this is likely to reflect the wide variation in other patient characteristics. Allowing for the small study size, our results show that the use of elective bilateral arterial punctures reduces fluoroscopy time, requires less catheter manipulation, and, according to the simulation model, has the potential to reduce patient dose. The overall procedure time, however, is not significantly reduced.


Asunto(s)
Embolización Terapéutica , Arteria Femoral , Leiomioma/terapia , Punciones/métodos , Neoplasias Uterinas/terapia , Útero/irrigación sanguínea , Adulto , Femenino , Fluoroscopía , Humanos , Estudios Prospectivos , Dosis de Radiación , Radiografía Intervencional , Piel/efectos de la radiación , Estadísticas no Paramétricas , Resultado del Tratamiento , Útero/efectos de la radiación
9.
Eur J Vasc Endovasc Surg ; 34(2): 176-8, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17482483

RESUMEN

Endovascular access for aneurysm repair can be challenging in patients with iliofemoral occlusive disease. The carotid artery is an alternative access site, but may increase the risk of cerebral hypoperfusion during stent delivery. We describe a novel approach, where temporary extra-corporeal bypass was used to maintain cerebral perfusion during endovascular thoracic aneurysm repair via the carotid artery, in a patient with significant aorto-iliac and arch vessel disease.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/métodos , Arterias Carótidas/cirugía , Circulación Cerebrovascular , Circulación Extracorporea , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/fisiopatología , Aortografía , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Femenino , Humanos , Persona de Mediana Edad , Selección de Paciente , Stents , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
11.
Clin Radiol ; 61(2): 142-53, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16439219

RESUMEN

In contemporary practice, most prostate cancers are either invisible on ultrasound or indistinguishable from concurrent benign prostatic hyperplasia. Diagnosis therefore rests on prostate biopsy. Biopsies are not simply directed at ultrasonically visible lesions, as these would miss many cancers; rather the whole gland is sampled. The sampling itself is systematic, using patterns based on prostate zonal anatomy and the geographical distribution and frequency of cancer. This review explains the evolution of the prostate biopsy technique, from the classical sextant biopsy method to the more recent extended biopsy protocols (8, 10, 12, >12 and saturation biopsy protocols). Extended protocols are increasingly being used to improve diagnostic accuracy, especially in those patients who require repeat biopsy. This trend has been facilitated by the ongoing improvement in safety and acceptability of the procedure, particularly with the use of antibiotic prophylaxis and local anaesthesia. The technical details of these extended protocols are discussed, as are the current data regarding procedure-related morbidity and how this may be minimized.


Asunto(s)
Biopsia con Aguja/métodos , Próstata/patología , Neoplasia Intraepitelial Prostática/patología , Neoplasias de la Próstata/patología , Ultrasonografía Intervencional/métodos , Factores de Edad , Anciano , Biopsia con Aguja/efectos adversos , Protocolos Clínicos , Humanos , Masculino , Persona de Mediana Edad , Dolor/etiología , Retratamiento , Medición de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...