Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
J Cardiovasc Magn Reson ; : 101100, 2024 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-39306195

RESUMEN

BACKGROUND: The diagnosis of myocarditis by CMR requires the use of T2 and T1 weighted imaging, ideally incorporating parametric mapping. Current 2D mapping sequences are acquired sequentially and involve multiple breath-holds resulting in prolonged scan times and anisotropic image resolution. We developed an isotropic free-breathing 3D whole-heart sequence which allows simultaneous T1 and T2 mapping and validated it in patients with suspected acute myocarditis. METHODS: Eighteen healthy volunteers and 28 patients with suspected myocarditis underwent conventional 2D T1 and T2 mapping with whole heart coverage and 3D joint T1/T2 mapping on a 1.5T scanner. Acquisition time, image quality, and diagnostic performance were compared. Qualitative analysis was performed using a 4-point Likert scale. Bland-Altman plots were used to assess the quantitative agreement between 2D and 3D sequences. RESULTS: The 3D T1/T2 sequence was acquired in 8mins 26s under free breathing, whereas 2D T1 and T2 sequences were acquired with breath holds in 11mins 44s (p=0.0001). All 2D images were diagnostic. For 3D images, 89% of T1 and 96% of T2 images were diagnostic with no significant difference in the proportion of diagnostic images for the 3D and 2D T1 (p=0.2482) and T2 maps (p=1.0000). Systematic bias in T1 was noted with biases of 102ms, 115ms, and 152ms for basal-apical segments, with a larger bias for higher T1 values. Good agreement between T2 values for 3D and 2D techniques was found (bias of 1.8ms, 3.9ms, and 3.6ms for basal-apical segments). The sensitivity and specificity of the 3D sequence for diagnosing acute myocarditis was 74% (95% confidence interval [CI] 49-91%) and 83% (36-100%) respectively, with an estimated c-statistic (95% CI) of 0.85 (0.79-0.91) and no statistically significant difference between the 2D and 3D sequences for the detection of acute myocarditis for T1 (p=0.2207) or T2 (p=1.0000). CONCLUSION: Free-breathing whole heart 3D joint T1/T2 mapping was comparable to 2D mapping sequences with respect to diagnostic performance, but with the added advantages of free-breathing, and shorter scan times. Further work is required to address the bias noted at high T1 values, but this did not significantly impact on diagnostic accuracy.

2.
Andes Pediatr ; 95(2): 190-195, 2024 Apr.
Artículo en Español | MEDLINE | ID: mdl-38801367

RESUMEN

Hypertriglyceridemia (HTG)-induced acute pancreatitis (AP) secondary to insulin deficiency following the onset of type 1 diabetes mellitus (T1DM) is a rare but serious complication in children. OBJECTIVE: To describe the diagnosis and treatment of severe HTG and to emphasize the need for timely diagnosis of T1DM. CLINICAL CASE: A 15-year-old female adolescent with a history of overweight presented with a two-weeks history of fever, anorexia, and diffuse abdominal pain. Laboratory tests revealed triglycerides of 17,580 mg/dL, lipase of 723 U/L, and blood glucose of 200 mg/dL. An abdominal CT scan showed an enlarged and edematous pancreas. She was hospitalized with a diagnosis of AP and severe HTG, which progressed to acute necro-hemorrhagic pancreatitis. Treatment included continuous intravenous insulin infusion until triglyceride levels decreased. Upon discontinuation of insulin, fasting hyperglycemia (206 mg/dL) and metabolic acidosis recurred, therefore DM was suspected. Upon targeted questioning, a history of polydipsia, polyuria, and weight loss during the last 3 months stood out. Glycated hemoglobin was markedly elevated (14.7%). Insulin therapy was optimized, achieving stabilization of laboratory parameters after 15 days of treatment and complete anatomical resolution of pancreatic involvement at one year of follow-up. CONCLUSIONS: The presence of severe HTG in pediatrics compels us to consider its secondary causes, such as the onset of T1DM. It is crucial to improve the ability to diagnose T1DM early, as it may present with infrequent and high-risk presentations for the patient.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipertrigliceridemia , Insulina , Pancreatitis , Humanos , Adolescente , Diabetes Mellitus Tipo 1/complicaciones , Femenino , Hipertrigliceridemia/complicaciones , Hipertrigliceridemia/diagnóstico , Pancreatitis/diagnóstico , Pancreatitis/etiología , Enfermedad Aguda , Insulina/uso terapéutico , Índice de Severidad de la Enfermedad , Hipoglucemiantes/uso terapéutico
3.
EJNMMI Phys ; 11(1): 36, 2024 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-38581561

RESUMEN

PURPOSE: A 2D image navigator (iNAV) based 3D whole-heart sequence has been used to perform MRI and PET non-rigid respiratory motion correction for hybrid PET/MRI. However, only the PET data acquired during the acquisition of the 3D whole-heart MRI is corrected for respiratory motion. This study introduces and evaluates an MRI-based respiratory motion correction method of the complete PET data. METHODS: Twelve oncology patients scheduled for an additional cardiac 18F-Fluorodeoxyglucose (18F-FDG) PET/MRI and 15 patients with coronary artery disease (CAD) scheduled for cardiac 18F-Choline (18F-FCH) PET/MRI were included. A 2D iNAV recorded the respiratory motion of the myocardium during the 3D whole-heart coronary MR angiography (CMRA) acquisition (~ 10 min). A respiratory belt was used to record the respiratory motion throughout the entire PET/MRI examination (~ 30-90 min). The simultaneously acquired iNAV and respiratory belt signal were used to divide the acquired PET data into 4 bins. The binning was then extended for the complete respiratory belt signal. Data acquired at each bin was reconstructed and combined using iNAV-based motion fields to create a respiratory motion-corrected PET image. Motion-corrected (MC) and non-motion-corrected (NMC) datasets were compared. Gating was also performed to correct cardiac motion. The SUVmax and TBRmax values were calculated for the myocardial wall or a vulnerable coronary plaque for the 18F-FDG and 18F-FCH datasets, respectively. RESULTS: A pair-wise comparison showed that the SUVmax and TBRmax values of the motion corrected (MC) datasets were significantly higher than those for the non-motion-corrected (NMC) datasets (8.2 ± 1.0 vs 7.5 ± 1.0, p < 0.01 and 1.9 ± 0.2 vs 1.2 ± 0.2, p < 0.01, respectively). In addition, the SUVmax and TBRmax of the motion corrected and gated (MC_G) reconstructions were also higher than that of the non-motion-corrected but gated (NMC_G) datasets, although for the TBRmax this difference was not statistically significant (9.6 ± 1.3 vs 9.1 ± 1.2, p = 0.02 and 2.6 ± 0.3 vs 2.4 ± 0.3, p = 0.16, respectively). The respiratory motion-correction did not lead to a change in the signal to noise ratio. CONCLUSION: The proposed respiratory motion correction method for hybrid PET/MRI improved the image quality of cardiovascular PET scans by increased SUVmax and TBRmax values while maintaining the signal-to-noise ratio. Trial registration METC162043 registered 01/03/2017.

4.
Front Microbiol ; 15: 1356966, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38389534

RESUMEN

Forages and concentrates have consistently distinct patterns of fermentation in the rumen, with forages producing more methane (CH4) per unit of digested organic matter (OM) and higher acetate to propionate ratio than concentrates. A mechanism based on the Monod function of microbial growth has been proposed to explain the distinct fermentation pattern of forages and concentrates, where greater dilution rates and lower pH associated with concentrate feeding increase dihydrogen (H2) concentration through increasing methanogens growth rate and decreasing methanogens theoretically maximal growth rate, respectively. Increased H2 concentration would in turn inhibit H2 production, decreasing methanogenesis, inhibit H2-producing pathways such as acetate production via pyruvate oxidative decarboxylation, and stimulate H2-incorporating pathways such as propionate production. We examined the hypothesis that equalizing dilution rates in serial rumen cultures would result in a similar fermentation profile of a high forage and a high concentrate substrate. Under a 2 × 3 factorial arrangement, a high forage and a high concentrate substrate were incubated at dilution rates of 0.14, 0.28, or 0.56 h-1 in eight transfers of serial rumen cultures. Each treatment was replicated thrice, and the experiment repeated in two different months. The high concentrate substrate accumulated considerably more H2 and formate and produced less CH4 than the high forage substrate. Methanogens were nearly washed-out with high concentrate and increased their initial numbers with high forage. The effect of dilution rate was minor in comparison to the effect of the type of substrate. Accumulation of H2 and formate with high concentrate inhibited acetate and probably H2 and formate production, and stimulated butyrate, rather than propionate, as an electron sink alternative to CH4. All three dilution rates are considered high and selected for rapidly growing bacteria. The archaeal community composition varied widely and inconsistently. Lactate accumulated with both substrates, likely favored by microbial growth kinetics rather than by H2 accumulation thermodynamically stimulating electron disposal from NADH into pyruvate reduction. In this study, the type of substrate had a major effect on rumen fermentation largely independent of dilution rate and pH.

5.
J Cardiovasc Magn Reson ; 26(1): 100008, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38194762

RESUMEN

BACKGROUND: Three dimensional, whole-heart (3DWH) MRI is an established non-invasive imaging modality in patients with congenital heart disease (CHD) for the diagnosis of cardiovascular morphology and for clinical decision making. Current techniques utilise diaphragmatic navigation (dNAV) for respiratory motion correction and gating and are frequently limited by long acquisition times. This study proposes and evaluates the diagnostic performance of a respiratory gating-free framework, which considers respiratory image-based navigation (iNAV), and highly accelerated variable density Cartesian sampling in concert with non-rigid motion correction and low-rank patch-based denoising (iNAV-3DWH-PROST). The method is compared to the clinical dNAV-3DWH sequence in adult patients with CHD. METHODS: In this prospective single center study, adult patients with CHD who underwent the clinical dNAV-3DWH MRI were also scanned with the iNAV-3DWH-PROST. Diagnostic confidence (4-point Likert scale) and diagnostic accuracy for common cardiovascular lesions was assessed by three readers. Scan times and diagnostic confidence were compared using the Wilcoxon-signed rank test. Co-axial vascular dimensions at three anatomic landmarks were measured, and agreement between the research and the corresponding clinical sequence was assessed with Bland-Altman analysis. RESULTS: The study included 60 participants (mean age ± [SD]: 33 ± 14 years; 36 men). The mean acquisition time of iNAV-3DWH-PROST was significantly lower compared with the conventional clinical sequence (3.1 ± 0.9 min vs 13.9 ± 3.9 min, p < 0.0001). Diagnostic confidence was higher for the iNAV-3DWH-PROST sequence compared with the clinical sequence (3.9 ± 0.2 vs 3.4 ± 0.8, p < 0.001), however there was no significant difference in diagnostic accuracy. Narrow limits of agreement and mean bias less than 0.08 cm were found between the research and the clinical vascular measurements. CONCLUSIONS: The iNAV-3DWH-PROST framework provides efficient, high quality and robust 3D whole-heart imaging in significantly shorter scan time compared to the standard clinical sequence.


Asunto(s)
Cardiopatías Congénitas , Imagenología Tridimensional , Valor Predictivo de las Pruebas , Humanos , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/fisiopatología , Masculino , Adulto , Estudios Prospectivos , Femenino , Reproducibilidad de los Resultados , Persona de Mediana Edad , Factores de Tiempo , Adulto Joven , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Respiración
6.
Magn Reson Med ; 91(5): 1951-1964, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38181169

RESUMEN

PURPOSE: Simultaneous PET-MRI improves inflammatory cardiac disease diagnosis. However, challenges persist in respiratory motion and mis-registration between free-breathing 3D PET and 2D breath-held MR images. We propose a free-breathing non-rigid motion-compensated 3D T2 -mapping sequence enabling whole-heart myocardial tissue characterization in a hybrid 3T PET-MR system and provides non-rigid respiratory motion fields to correct also simultaneously acquired PET data. METHODS: Free-breathing 3D whole-heart T2 -mapping was implemented on a hybrid 3T PET-MRI system. Three datasets were acquired with different T2 -preparation modules (0, 28, 55 ms) using 3-fold undersampled variable-density Cartesian trajectory. Respiratory motion was estimated via virtual 3D image navigators, enabling multi-contrast non-rigid motion-corrected MR reconstruction. T2 -maps were computed using dictionary-matching. Approach was tested in phantom, 8 healthy subjects, 14 MR only and 2 PET-MR patients with suspected cardiac disease and compared with spin echo reference (phantom) and clinical 2D T2 -mapping (in-vivo). RESULTS: Phantom results show a high correlation (R2 = 0.996) between proposed approach and gold standard 2D T2 mapping. In-vivo 3D T2 -mapping average values in healthy subjects (39.0 ± 1.4 ms) and patients (healthy tissue) (39.1 ± 1.4 ms) agree with conventional 2D T2 -mapping (healthy = 38.6 ± 1.2 ms, patients = 40.3 ± 1.7 ms). Bland-Altman analysis reveals bias of 1.8 ms and 95% limits of agreement (LOA) of -2.4-6 ms for healthy subjects, and bias of 1.3 ms and 95% LOA of -1.9 to 4.6 ms for patients. CONCLUSION: Validated efficient 3D whole-heart T2 -mapping at hybrid 3T PET-MRI provides myocardial inflammation characterization and non-rigid respiratory motion fields for simultaneous PET data correction. Comparable T2 values were achieved with both 3D and 2D methods. Improved image quality was observed in the PET images after MR-based motion correction.


Asunto(s)
Miocarditis , Miocardio , Humanos , Imagen por Resonancia Magnética , Movimiento (Física) , Imagenología Tridimensional/métodos , Tomografía de Emisión de Positrones , Corazón/diagnóstico por imagen , Fantasmas de Imagen
8.
Eur Respir J ; 62(5)2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37827576

RESUMEN

BACKGROUND: Longitudinal cohort data of patients with tuberculosis (TB) and coronavirus disease 2019 (COVID-19) are lacking. In our global study, we describe long-term outcomes of patients affected by TB and COVID-19. METHODS: We collected data from 174 centres in 31 countries on all patients affected by COVID-19 and TB between 1 March 2020 and 30 September 2022. Patients were followed-up until cure, death or end of cohort time. All patients had TB and COVID-19; for analysis purposes, deaths were attributed to TB, COVID-19 or both. Survival analysis was performed using Cox proportional risk-regression models, and the log-rank test was used to compare survival and mortality attributed to TB, COVID-19 or both. RESULTS: Overall, 788 patients with COVID-19 and TB (active or sequelae) were recruited from 31 countries, and 10.8% (n=85) died during the observation period. Survival was significantly lower among patients whose death was attributed to TB and COVID-19 versus those dying because of either TB or COVID-19 alone (p<0.001). Significant adjusted risk factors for TB mortality were higher age (hazard ratio (HR) 1.05, 95% CI 1.03-1.07), HIV infection (HR 2.29, 95% CI 1.02-5.16) and invasive ventilation (HR 4.28, 95% CI 2.34-7.83). For COVID-19 mortality, the adjusted risks were higher age (HR 1.03, 95% CI 1.02-1.04), male sex (HR 2.21, 95% CI 1.24-3.91), oxygen requirement (HR 7.93, 95% CI 3.44-18.26) and invasive ventilation (HR 2.19, 95% CI 1.36-3.53). CONCLUSIONS: In our global cohort, death was the outcome in >10% of patients with TB and COVID-19. A range of demographic and clinical predictors are associated with adverse outcomes.


Asunto(s)
COVID-19 , Coinfección , Infecciones por VIH , Tuberculosis Miliar , Humanos , Masculino , COVID-19/complicaciones , Infecciones por VIH/complicaciones , Factores de Riesgo , Estudios Retrospectivos
9.
J Otol ; 18(3): 111-117, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37497327

RESUMEN

Objective: Contribute to clarifying the existence of subclinical hearing deficits associated with aging. Design: In this work, we study and compare the auditory perceptual and electrophysiological performance of normal-hearing young and adult subjects (tonal audiometry, high-frequency tone threshold, a triplet of digits in noise, and click-evoked auditory brainstem response). Study sample: 45 normal hearing volunteers were evaluated and divided into two groups according to age. 27 subjects were included in the "young group" (mean 22.1 years), and 18 subjects (mean 42.22 years) were included in the "adult group." Results: In the perceptual tests, the adult group presented significantly worse tonal thresholds in the high frequencies (12 and 16 kHz) and worse performance in the digit triplet tests in noise. In the electrophysiological test using the auditory brainstem response technique, the adult group presented significantly lower I and V wave amplitudes and higher V wave latencies at the supra-threshold level. At the threshold level, we observed a significantly higher latency in wave V in the adult group. In addition, in the partial correlation analysis, controlling for the hearing level, we observed a relationship (negative) between age and speech in noise performance and high-frequency thresholds. No significant association was observed between age and the auditory brainstem response. Conclusion: The results are compatible with subclinical hearing loss associated with aging.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...