Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Int J Hematol ; 119(4): 426-431, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38363480

RESUMEN

Silent inactivation of L-asparaginase (L-Asp) represents rapid clearance of L-Asp by anti-L-Asp IgG antibodies without clinical symptoms. Measurement of L-Asp activity is the gold standard for diagnosis of silent inactivation, but this test is not commercially available in Japan as of 2023. We evaluated ex vivo and in vivo ammonia production in relation to L-Asp activity. Blood samples from ten adult patients treated with L-Asp were collected to measure ammonia levels and L-Asp activity before the first dose and 24 h after the last dose of L-Asp, during each cycle of treatment. Plasma ammonia levels were analyzed immediately and 1 h after incubation at room temperature, and ex vivo ammonia production was defined as the increase in ammonia concentration. Ex vivo ammonia production correlated with L-Asp activity (R2 = 0.741), and ammonia levels measured immediately after blood collection were moderately correlated with L-Asp activity (R2 = 0.709). One patient with extranodal NK/T-cell lymphoma showed an increase in ammonia levels during the first cycle, but no increase in ammonia levels or L-Asp activity after L-Asp administration during the second cycle. Both ex vivo and in vivo ammonia production and surrogate markers are used for L-Asp biological activity.


Asunto(s)
Asparaginasa , Leucemia-Linfoma Linfoblástico de Células Precursoras , Adulto , Humanos , Asparaginasa/efectos adversos , Amoníaco/uso terapéutico , Leucemia-Linfoma Linfoblástico de Células Precursoras/tratamiento farmacológico , Anticuerpos , Biomarcadores
2.
PLoS One ; 16(10): e0258647, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34673803

RESUMEN

BACKGROUND: Bispectral index (BIS) monitoring is a widely used non-invasive method to monitor the depth of anesthesia. However, in the event of surgeries requiring a frontal approach, placement of the electrode may be impossible at the designated area to achieve a proper BIS measurement. METHODS: We developed an investigational interface device to connect needle-electrodes to BIS sensors. The safety and clinical performance were investigated in patients who underwent surgery. Direct BIS values from a disposable BIS electrode and indirect values via the interface device were simultaneously recorded from the same areas of electrode placement in a single patient. The agreement between the direct and indirect BIS values was statistically analyzed. RESULTS: The interface device with a silver electrode demonstrated sufficient electric conduction to transmit electroencephalogram signals. The overall BIS curves were similar to those of direct BIS monitoring. Direct and indirect BIS values from 18 patients were statistically analyzed using a linear mixed model and a significant concordance was confirmed (indirect BIS = 7.0405 + 0.8286 * direct BIS, p<0.0001). Most observed data (2582/2787 data points, 92.64%) had BIS unit differences of 10 or less. CONCLUSIONS: The interface device provides an opportunity for intraoperative BIS monitoring of patients, whose clinical situation does not permit the placement of conventional adhesive sensors at the standard location.


Asunto(s)
Anestesia General/métodos , Técnicas Biosensibles/métodos , Electrodos , Electroencefalografía/efectos de los fármacos , Electroencefalografía/instrumentación , Monitoreo Intraoperatorio/métodos , Procedimientos Neuroquirúrgicos/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...