Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
EuroIntervention ; 18(13): e1090-e1098, 2023 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-36147027

RESUMEN

BACKGROUND: Cardiac stress tests remain the cornerstone for evaluating patients suspected of having obstructive coronary artery disease (CAD). Coronary microvascular dysfunction (CMD) can lead to abnormal non-invasive tests. AIMS: We sought to assess the diagnostic performance of exercise stress tests with indexes of epicardial and microvascular resistance as reference. METHODS: This was a prospective, single-arm, multicentre study of patients with an intermediate pretest probability of CAD and positive exercise stress tests who were referred for invasive angiography. Patients underwent an invasive diagnostic procedure (IDP) with measurement of fractional flow reserve (FFR) and index of microvascular resistance (IMR) in at least one coronary vessel. Obstructive CAD was defined as diameter stenosis (DS) >50% by quantitative coronary angiography (QCA). The objective was to determine the false discovery rate (FDR) of cardiac exercise stress tests with both FFR and IMR as references. RESULTS: One hundred and seven patients (137 vessels) were studied. The mean age was 62.1±8.7, and 27.1% were female. The mean diameter stenosis was 37.2±27.5%, FFR was 0.84±0.10, coronary flow reserve was 2.74±2.07, and IMR 20.3±11.9. Obstructive CAD was present in 39.3%, whereas CMD was detected in 20.6%. The FDR was 60.7% and 62.6% with QCA and FFR as references (p-value=0.803). The combination of FFR and IMR as clinical reference reduced the FDR by 25% compared to QCA (45.8% vs 60.7%; p-value=0.006). CONCLUSIONS: In patients with evidence of ischaemia, an invasive functional assessment accounting for the epicardial and microvascular compartments led to an improvement in the diagnostic performance of exercise tests, driven by a significant FDR reduction.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Femenino , Masculino , Enfermedad de la Arteria Coronaria/diagnóstico , Prueba de Esfuerzo , Estenosis Coronaria/diagnóstico , Constricción Patológica , Estudios Prospectivos , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad
3.
Cardiovasc Revasc Med ; 21(11S): 158-161, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32029391

RESUMEN

BACKGROUND: Bioresorbable scaffold (BRS) have the aim to combine short-term radial force by vessel scaffold (which should dissolve after few months), with drug eluting capability. It has been hypothesized that complete resorption would result in restoration of vasomotion, reduction in angina and reduction of restenosis. CASE PRESENTATION: We report a case of 7 years angiographic follow up after DESolve Novolimus eluting Bioresorbable Coronary Scaffold System implantation. CONCLUSION: The invasive control showed persistence of scaffold patency and evidence of restored vascular motility by the growing in vessel diameter at QCA control after nitrates administration.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Estudios de Seguimiento , Humanos , Intervención Coronaria Percutánea , Diseño de Prótesis , Resultado del Tratamiento
4.
Acta Cardiol ; 74(1): 38-44, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29457955

RESUMEN

The radiation exposure in the cath lab of patients, cardiologists, and nurses was measured during three consecutive periods of 8 weeks. The first 8 weeks the baseline radiation exposure was obtained. In the second period standard incidences for coronarography and frame rate were changed, without compromising the image quality of the examination. In the third period, a pelvic shield covered the lower part of the patient. This pilot quality project demonstrates that further significant reduction in radiation exposure of 37% is possible for patients. A significant reduction in radiation exposure of 53 and 62% was obtained among cardiologists and nurses working in the cath lab, even with the already diminished radiation exposure over the last years by better equipment and general radioprotection measures.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Exposición Profesional/prevención & control , Salud Laboral , Exposición a la Radiación/prevención & control , Traumatismos por Radiación/prevención & control , Protección Radiológica/normas , Medición de Riesgo , Cardiólogos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Exposición Profesional/efectos adversos , Proyectos Piloto , Dosis de Radiación , Exposición a la Radiación/efectos adversos , Factores de Riesgo , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...