1.
BMJ Case Rep ; 14(1)2021 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-33509864

RESUMEN

We report the case of a 69-year-old man, who presented in the UK with a short history of deteriorating vision and clinical features of bilateral atypical retinochoroiditis, after travelling to South America. Vitreous samples demonstrated Toxoplasma gondii DNA by PCR. Serology tests demonstrated recent acquired Toxoplasma gondii infection with IgM antibodies. He responded well to treatment with trimethoprim-sulfamethoxazole, azithromycin and oral steroids.This case is a reminder of the global importance of Toxoplasma related eye disease, and its uncommon bilateral severe presentation in a returning traveller, where the risk factors were age and the route of infection likely to be a virulent parasite oocyst from vegetables or water rather than undercooked meat or direct contact with cats.


Asunto(s)
Toxoplasmosis Ocular/diagnóstico , Enfermedad Relacionada con los Viajes , Factores de Edad , Anciano , Antibacterianos/uso terapéutico , Azitromicina/uso terapéutico , Fondo de Ojo , Glucocorticoides/uso terapéutico , Humanos , Masculino , América del Sur , Tomografía de Coherencia Óptica , Toxoplasmosis Ocular/tratamiento farmacológico , Toxoplasmosis Ocular/patología , Toxoplasmosis Ocular/transmisión , Combinación Trimetoprim y Sulfametoxazol/uso terapéutico , Reino Unido
2.
J Med Microbiol ; 68(9): 1324-1329, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31355739

RESUMEN

Purpose. To investigate the use of a corneal impression membrane (CIM) for the detection of herpes simplex virus type 1 (HSV-1) in suspected herpes simplex keratitis (HSK).Methodology. In the laboratory study, swabs and CIMs made from polytetrafluoroethylene were spiked with different concentrations of HSV-1. DNA was extracted and real-time PCR undertaken using two sets of primers. In the clinical study, consecutive patients presenting with suspected HSK were included. For each patient, samples were collected from corneal lesions with a swab and a CIM in random order. Clinical details were collected using a standardized clinical form and patients were categorized into probable, presumed and possible HSK.Results. There was no difference in the performance of both primer sets for all HSV-1 dilutions (P=0.83) using a CIM or between a CIM and a swab (P=0.18). In total, 110 patients were included. Overall, 73 patients (66.4 %) had probable, 20 patients (18.2 %) presumed and 17 patients (15.5 %) possible HSV-1 keratitis. The HSV-1 detection rate was significantly higher using a CIM (40/110, 36.4 %) than a swab (28/110, 25.5 %) (P=0.004). In the probable HSV keratitis group, the detection rate using a CIM was 43.8 % compared to 27.4 % for a swab (P=0.004). The cycle threshold values obtained for the conjunctival swabs were higher than those obtained for the CIMs (P<0.001).Conclusions. In suspected HSK, a CIM is a useful alternative to a swab and more likely to detect the presence of HSV-1.


Asunto(s)
Córnea/virología , Herpes Simple/diagnóstico , Herpesvirus Humano 1/aislamiento & purificación , Técnicas de Diagnóstico Molecular/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Manejo de Especímenes/métodos , Adulto , Anciano , Anciano de 80 o más Años , Cartilla de ADN/genética , ADN Viral/genética , ADN Viral/aislamiento & purificación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
3.
Ophthalmologica ; 238(1-2): 68-73, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28419996

RESUMEN

PURPOSE: To report the efficacy and safety of polydimethyl siloxane (Siluron Xtra®) as an internal tamponade. DESIGN: Audit and adverse event screening of procedures (March 2014-2015). METHODS: Patients who had undergone vitreoretinal procedures with Siluron Xtra® tamponade were retrospectively analysed with respect to anatomical outcome, visual outcomes, and perioperative complications, in particular intraocular pressure. INCLUSION CRITERIA: all patients who had undergone Siluron Xtra® tamponade. EXCLUSION CRITERIA: No cases were excluded; however, there were no paediatric or pregnant patients within this cohort. All vitreoretinal cases were included, including retinal detachments, but also trauma, endophthalmitis, and intraocular foreign bodies. RESULTS: Twenty-eight patients had polydimethyl siloxane as an intraocular tamponade; 24 retinal detachments (83% complicated by proliferative vitreoretinopathy ≥grade C), 12 had previous failed surgery, and 4 had procedures for intraocular lymphoma, endophthalmitis, or trauma. Follow-up was 14-20 months, and mean duration of tamponade was 6.8 months (3-12 months). Anatomical success was 79% after polydimethyl siloxane injection, 58% 3 months following removal (14/24), 5 remain with long-term tamponade, and 5 with redetachment under tamponade required further intervention. Five required topical anti-glaucomatous agents, and 1 following trauma required glaucoma surgery. Cataract developed in 3/6 phakic patients, and visible emulsification occurred in a single patient. CONCLUSION: Polydimethyl siloxane seems to be an acceptable alternative tamponade agent for the management of complex retinal detachments with comparable anatomical success and comparable rates of raised intraocular pressure to other low-viscosity silicone oil agents, but more importantly, with a lower rate of emulsified oil-related complications, which is important particularly for cases requiring long-term tamponade.


Asunto(s)
Dimetilpolisiloxanos/administración & dosificación , Endotaponamiento/métodos , Oftalmopatías/cirugía , Complicaciones Posoperatorias/epidemiología , Cirugía Vitreorretiniana/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Reino Unido/epidemiología , Adulto Joven
4.
J Cataract Refract Surg ; 43(1): 12-15, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-28317665

RESUMEN

We present a technique to achieve ultrathin Descemet-stripping automated endothelial keratoplasty (DSAEK). Using a simple method of controlling artificial anterior chamber pressure and drying the corneal surface, it was possible to thin the donor cornea at a rate of 11 µm a minute. When the donor cornea was between 500 µm and 510 µm, a single pass was made using a 350 µm microkeratome head followed by a peripheral dissection. The resulting mean graft thickness was 83.2 µm ± 14.9 (SD) (range 50 to 98 µm) with a mean peripheral graft edge thickness of 106.8 ± 10.9 µm (range 90 to 120 µm). There were no surgical complications, and all grafts remained attached. This is a reliable method for preparing ultrathin donor corneal lenticules for DSAEK in the operating room or eye bank without using multiple microkeratome heads or risking double passes.


Asunto(s)
Queratoplastia Endotelial de la Lámina Limitante Posterior/métodos , Endotelio Corneal/trasplante , Recolección de Tejidos y Órganos/métodos , Anciano , Recuento de Células , Enfermedades de la Córnea/cirugía , Endotelio Corneal/diagnóstico por imagen , Humanos , Persona de Mediana Edad , Donantes de Tejidos , Tomografía de Coherencia Óptica
SELECCIÓN DE REFERENCIAS