1.
Cureus ; 13(9): e18034, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34671522

RESUMEN

Background/Aim The aim of this study was to compare volumetric-modulated arc therapy (VMAT) radiation plans between conventional VMAT with flattening filter (cFF-VMAT) and flattening filter-free VMAT (FFF-VMAT) for localized prostate cancer. Materials and methods Ten patients with localized prostate cancer who underwent cFF-VMAT at Yokosuka General Hospital Uwamachi, Yokosuka, Japan, from July 2020 to October 2020 were enrolled. Dose-volume histogram (DVH) parameters of the target volume, normal organs, monitor units (MU), and beam-on time (BOT) were compared between cFF-VMAT and FFF-VMAT plans. Results No significant difference was observed for DVH parameters for the target volume. No significant difference was observed in all parameters for the bladder and rectum between the cFF-VMAT and FFF-VMAT groups. The mean values of MU were 686 ± 52 and 784 ± 80 in cFF-VMAT and FFF-VMAT, respectively (p < 0.001). The mean BOT was 97.0 ± 6.6 s and 72.9 ± 1.4 s for cFF-VMAT and FFF-VMAT, respectively (p < 0.001). Conclusion DVH parameters of the target volume and normal organs were not significantly different between the cFF-VMAT and FFF-VMAT plans. In FFF-VMAT, MU was significantly higher, and the BOT was significantly shorter than those in cFF-VMAT.