Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
IEEE Trans Med Imaging ; PP2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38717879

RESUMEN

Fluorescence molecular endoscopy (FME) is emerging as a "red-flag" technique with potential to deliver earlier, faster, and more personalized detection of disease in the gastrointestinal tract, including cancer, and to gain insights into novel drug distribution, dose finding, and response prediction. However, to date, the performance of FME systems is assessed mainly by endoscopists during a procedure, leading to arbitrary, potentially biased, and heavily subjective assessment. This approach significantly affects the repeatability of the procedures and the interpretation or comparison of the acquired data, representing a major bottleneck towards the clinical translation of the technology. Herein, we propose a robust methodology for FME performance assessment and quality control that is based on a novel multi-parametric rigid standard. This standard enables the characterization of an FME system's sensitivity through a single acquisition, performance comparison of multiple systems, and, for the first time, quality control of a system as a function of time and number of usages. We show the photostability of the standard experimentally and demonstrate how it can be used to characterize the performance of an FME system. Moreover, we showcase how the standard can be employed for quality control of a system. In this study, we find that the use of composite fluorescence standards before endoscopic procedures can ensure that an FME system meets the performance criteria and that components prone to performance degradation are replaced in time, avoiding disruption of clinical endoscopy logistics. This will help overcome a major barrier for the translation of FME into the clinics.

2.
Gastrointest Endosc ; 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38636819

RESUMEN

BACKGROUND & AIMS: Characterization of visible abnormalities in Barrett esophagus (BE) patients can be challenging, especially for unexperienced endoscopists. This results in suboptimal diagnostic accuracy and poor inter-observer agreement. Computer-aided diagnosis (CADx) systems may assist endoscopists. We aimed to develop, validate and benchmark a CADx system for BE neoplasia. METHODS: The CADx system received pretraining with ImageNet with consecutive domain-specific pretraining with GastroNet which includes 5 million endoscopic images. It was subsequently trained and internally validated using 1,758 narrow-band imaging (NBI) images of early BE neoplasia (352 patients) and 1,838 NBI images of non-dysplastic BE (173 patients) from 8 international centers. CADx was tested prospectively on corresponding image and video test sets with 30 cases (20 patients) of BE neoplasia and 60 cases (31 patients) of non-dysplastic BE. The test set was benchmarked by 44 general endoscopists in two phases (phase 1: no CADx assistance; phase 2: with CADx assistance). Ten international BE experts provided additional benchmark performance. RESULTS: Stand-alone sensitivity and specificity of the CADx system were 100% and 98% for images and 93% and 96% for videos, respectively. CADx outperformed general endoscopists without CADx assistance in terms of sensitivity (p=0.04). Sensitivity and specificity of general endoscopist increased from 84% to 96% and 90 to 98% with CAD assistance (p<0.001), respectively. CADx assistance increased endoscopists' confidence in characterization (p<0.001). CADx performance was similar to Barrett experts. CONCLUSION: CADx assistance significantly increased characterization performance of BE neoplasia by general endoscopists to the level of expert endoscopists. The use of this CADx system may thereby improve daily Barrett surveillance.

3.
Gut ; 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38580386

RESUMEN

OBJECTIVE: Improving patient selection and development of biological therapies such as vedolizumab in IBD requires a thorough understanding of the mechanism of action and target binding, thereby providing individualised treatment strategies. We aimed to visualise the macroscopic and microscopic distribution of intravenous injected fluorescently labelled vedolizumab, vedo-800CW, and identify its target cells using fluorescence molecular imaging (FMI). DESIGN: Forty three FMI procedures were performed, which consisted of macroscopic in vivo assessment during endoscopy, followed by macroscopic and microscopic ex vivo imaging. In phase A, patients received an intravenous dose of 4.5 mg, 15 mg vedo-800CW or no tracer prior to endoscopy. In phase B, patients received 15 mg vedo-800CW preceded by an unlabelled (sub)therapeutic dose of vedolizumab. RESULTS: FMI quantification showed a dose-dependent increase in vedo-800CW fluorescence intensity in inflamed tissues, with 15 mg (153.7 au (132.3-163.7)) as the most suitable tracer dose compared with 4.5 mg (55.3 au (33.6-78.2)) (p=0.0002). Moreover, the fluorescence signal decreased by 61% when vedo-800CW was administered after a therapeutic dose of unlabelled vedolizumab, suggesting target saturation in the inflamed tissue. Fluorescence microscopy and immunostaining showed that vedolizumab penetrated the inflamed mucosa and was associated with several immune cell types, most prominently with plasma cells. CONCLUSION: These results indicate the potential of FMI to determine the local distribution of drugs in the inflamed target tissue and identify drug target cells, providing new insights into targeted agents for their use in IBD. TRIAL REGISTRATION NUMBER: NCT04112212.

4.
Gastroenterology ; 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38447738

RESUMEN

BACKGROUND & AIMS: Follow-up (FU) strategies after endoscopic eradication therapy (EET) for Barrett's neoplasia do not consider the risk of mortality from causes other than esophageal adenocarcinoma (EAC). We aimed to evaluate this risk during long-term FU, and to assess whether the Charlson Comorbidity Index (CCI) can predict mortality. METHODS: We included all patients with successful EET from the nationwide Barrett registry in the Netherlands. Data were merged with National Statistics for accurate mortality data. We evaluated annual mortality rates (AMRs, per 1000 person-years) and standardized mortality ratio for other-cause mortality. Performance of the CCI was evaluated by discrimination and calibration. RESULTS: We included 1154 patients with a mean age of 64 years (±9). During median 59 months (p25-p75 37-91; total 6375 person-years), 154 patients (13%) died from other causes than EAC (AMR, 24.1; 95% CI, 20.5-28.2), most commonly non-EAC cancers (n = 58), cardiovascular (n = 31), or pulmonary diseases (n = 26). Four patients died from recurrent EAC (AMR, 0.5; 95% CI, 0.1-1.4). Compared with the general Dutch population, mortality was significantly increased for patients in the lowest 3 age quartiles (ie, age <71 years). Validation of CCI in our population showed good discrimination (Concordance statistic, 0.78; 95% CI, 0.72-0.84) and fair calibration. CONCLUSION: The other-cause mortality risk after successful EET was more than 40 times higher (48; 95% CI, 15-99) than the risk of EAC-related mortality. Our findings reveal that younger post-EET patients exhibit a significantly reduced life expectancy when compared with the general population. Furthermore, they emphasize the strong predictive ability of CCI for long-term mortality after EET. This straightforward scoring system can inform decisions regarding personalized FU, including appropriate cessation timing. (NL7039).

5.
Antimicrob Resist Infect Control ; 13(1): 31, 2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38459544

RESUMEN

Contamination of duodenoscopes is a significant concern due to the transmission of multidrug-resistant organisms (MDROs) among patients who undergo endoscopic retrograde cholangiopancreatography (ERCP), resulting in outbreaks worldwide. In July 2020, it was determined that three different patients, all had undergone ERCP with the same duodenoscope, were infected. Two patients were infected with blaCTX-M-15 encoding Citrobacter freundii, one experiencing a bloodstream infection and the other a urinary tract infection, while another patient had a bloodstream infection caused by blaSHV-12 encoding Klebsiella pneumoniae. Molecular characterization of isolates was available as every ESBL-producing isolate undergoes Next-Generation Sequencing (NGS) for comprehensive genomic analysis in our center. After withdrawing the suspected duodenoscope, we initiated comprehensive epidemiological research, encompassing case investigations, along with a thorough duodenoscope investigation. Screening of patients who had undergone ERCP with the implicated duodenoscope, as well as a selection of hospitalized patients who had ERCP with a different duodenoscope during the outbreak period, led to the discovery of three additional cases of colonization in addition to the three infections initially detected. No microorganisms were detected in eight routine culture samples retrieved from the suspected duodenoscope. Only after destructive dismantling of the duodenoscope, the forceps elevator was found to be positive for blaSHV-12 encoding K. pneumoniae which was identical to the isolates detected in three patients. This study highlights the importance of using NGS to monitor the transmission of MDROs and demonstrates that standard cultures may fail to detect contaminated medical equipment such as duodenoscopes.


Asunto(s)
Duodenoscopios , Sepsis , Humanos , Bacterias/genética , beta-Lactamasas/genética , Klebsiella pneumoniae/genética , Secuenciación de Nucleótidos de Alto Rendimiento
6.
Endoscopy ; 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38378018

RESUMEN

BACKGROUND: This study evaluated the proportion of patients with residual neoplasia after endoscopic resection (ER) for Barrett's neoplasia with confirmed tumor-positive vertical resection margin (R1v). METHODS: This retrospective cohort study included patients undergoing ER for Barrett's neoplasia with histologically documented R1v since 2008 in the Dutch Barrett Expert Centers. We defined R1v as cancer cells touching vertical resection margins and Rx as nonassessable margins. Reassessment of R1v specimens was performed by experienced pathologists until consensus was reached regarding vertical margins. RESULTS: 101/110 included patients had macroscopically complete resections (17 T1a, 84 T1b), and 99/101 (98%) ER specimens were histologically reassessed, with R1v confirmed in 74 patients (75%), Rx in 16%, and R0 in 9%. Presence/absence of residual neoplasia could be assessed in 66/74 patients during endoscopic reassessment (52) and/or in the surgical resection specimen (14), and 33/66 (50%) had residual neoplasia. Residual neoplasia detected during endoscopy was always endoscopically visible and biopsies from a normal-appearing ER scar did not detect additional neoplasia. Of 25 patients who underwent endoscopic follow-up (median 37 months [interquartile range 12-50]), 4 developed local recurrence (16.0%), all detected as visible abnormalities. CONCLUSIONS: After ER with R1v, 50% of patients had no residual neoplasia. Histological evaluation of ER margins appears challenging, as in this study 75% of documented R1v cases were confirmed during reassessment. Endoscopic reassessment 8-12 weeks after ER seems to accurately detect residual neoplasia and can help to determine the most appropriate strategy for patients with R1v.

7.
Gastroenterology ; 166(4): 690-703, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38158089

RESUMEN

BACKGROUND & AIMS: Gastrointestinal angiodysplasias are vascular anomalies that may result in transfusion-dependent anemia despite endoscopic therapy. An individual patient data meta-analysis of cohort studies suggests that octreotide decreases rebleeding rates, but component studies possessed a high risk of bias. We investigated the efficacy of octreotide in reducing the transfusion requirements of patients with angiodysplasia-related anemia in a clinical trial setting. METHODS: The study was designed as a multicenter, open-label, randomized controlled trial. Patients with angiodysplasia bleeding were required to have had at least 4 red blood cell (RBC) units or parental iron infusions, or both, in the year preceding randomization. Patients were allocated (1:1) to 40-mg octreotide long-acting release intramuscular every 28 days or standard of care, including endoscopic therapy. The treatment duration was 1 year. The primary outcome was the mean difference in the number of transfusion units (RBC + parental iron) between the octreotide and standard of care groups. Patients who received at least 1 octreotide injection or followed standard of care for at least 1 month were included in the intention-to-treat analyses. Analyses of covariance were used to adjust for baseline transfusion requirements and incomplete follow-up. RESULTS: We enrolled 62 patients (mean age, 72 years; 32 men) from 17 Dutch hospitals in the octreotide (n = 31) and standard of care (n = 31) groups. Patients required a mean number of 20.3 (standard deviation, 15.6) transfusion units and 2.4 (standard deviation, 2.0) endoscopic procedures in the year before enrollment. The total number of transfusions was lower with octreotide (11.0; 95% confidence interval [CI], 5.5-16.5) compared with standard of care (21.2; 95% CI, 15.7-26.7). Octreotide reduced the mean number of transfusion units by 10.2 (95% CI, 2.4-18.1; P = .012). Octreotide reduced the annual volume of endoscopic procedures by 0.9 (95% CI, 0.3-1.5). CONCLUSIONS: Octreotide effectively reduces transfusion requirements and the need for endoscopic therapy in patients with angiodysplasia-related anemia. CLINICALTRIALS: gov, NCT02384122.


Asunto(s)
Anemia , Angiodisplasia , Enfermedades del Colon , Anciano , Humanos , Masculino , Anemia/tratamiento farmacológico , Anemia/etiología , Angiodisplasia/complicaciones , Angiodisplasia/diagnóstico , Angiodisplasia/terapia , Enfermedades del Colon/tratamiento farmacológico , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/tratamiento farmacológico , Hemorragia Gastrointestinal/etiología , Hierro , Estudios Multicéntricos como Asunto , Octreótido/uso terapéutico , Ensayos Clínicos Controlados Aleatorios como Asunto , Nivel de Atención , Femenino
8.
Surg Endosc ; 37(11): 8394-8403, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37721591

RESUMEN

BACKGROUND: Patients with cT1-2 colon cancer (CC) have a 10-20% risk of lymph node metastases. Sentinel lymph node identification (SLNi) could improve staging and reduce morbidity in future organ-preserving CC surgery. This pilot study aimed to assess safety and feasibility of robot-assisted fluorescence-guided SLNi using submucosally injected indocyanine green (ICG) in patients with cT1-2N0M0 CC. METHODS: Ten consecutive patients with cT1-2N0M0 CC were included in this prospective feasibility study. Intraoperative submucosal, peritumoral injection of ICG was performed during a colonoscopy. Subsequently, the near-infrared fluorescence 'Firefly' mode of the da Vinci Xi robotic surgical system was used for SLNi. SLNs were marked with a suture, after which a segmental colectomy was performed. The SLN was postoperatively ultrastaged using serial slicing and immunohistochemistry, in addition to the standard pathological examination of the specimen. Colonoscopy time, detection time (time from ICG injection to first SLNi), and total SLNi time were measured (time from the start of colonoscopy to start of segmental resection). Intraoperative, postoperative, and pathological outcomes were registered. RESULTS: In all patients, at least one SLN was identified (mean 2.3 SLNs, SLN diameter range 1-13 mm). No tracer-related adverse events were noted. Median colonoscopy time was 12 min, detection time was 6 min, and total SLNi time was 30.5 min. Two patients had lymph node metastases present in the SLN, and there were no patients with false negative SLNs. No patient was upstaged due to ultrastaging of the SLN after an initial negative standard pathological examination. Half of the patients unexpectedly had pT3 tumours. CONCLUSIONS: Robot-assisted fluorescence-guided SLNi using submucosally injected ICG in ten patients with cT1-2N0M0 CC was safe and feasible. SLNi was performed in an acceptable timespan and SLNs down to 1 mm were detected. All lymph node metastases would have been detected if SLN biopsy had been performed.


Asunto(s)
Neoplasias del Colon , Linfadenopatía , Robótica , Ganglio Linfático Centinela , Humanos , Ganglio Linfático Centinela/cirugía , Ganglio Linfático Centinela/patología , Metástasis Linfática/patología , Biopsia del Ganglio Linfático Centinela , Estudios Prospectivos , Proyectos Piloto , Estadificación de Neoplasias , Colorantes , Verde de Indocianina , Neoplasias del Colon/cirugía , Neoplasias del Colon/patología , Linfadenopatía/patología , Ganglios Linfáticos/patología
9.
Nat Commun ; 14(1): 4952, 2023 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-37587149

RESUMEN

Inadequate surgical margins occur frequently in oral squamous cell carcinoma surgery. Fluorescence molecular imaging (FMI) has been explored for intraoperative margin assessment, but data are limited to phase-I studies. In this single-arm phase-II study (NCT03134846), our primary endpoints were to determine the sensitivity, specificity and positive predictive value of cetuximab-800CW for tumor-positive margins detection. Secondary endpoints were safety, close margin detection rate and intrinsic cetuximab-800CW fluorescence. In 65 patients with 66 tumors, cetuximab-800CW was well-tolerated. Fluorescent spots identified in the surgical margin with signal-to-background ratios (SBR) of ≥2 identify tumor-positive margins with 100% sensitivity, 85.9% specificity, 58.3% positive predictive value, and 100% negative predictive value. An SBR of ≥1.5 identifies close margins with 70.3% sensitivity, 76.1% specificity, 60.5% positive predictive value, and 83.1% negative predictive value. Performing frozen section analysis aimed at the fluorescent spots with an SBR of ≥1.5 enables safe, intraoperative adjustment of surgical margins.


Asunto(s)
Carcinoma de Células Escamosas , Neoplasias de la Boca , Humanos , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/cirugía , Cetuximab , Colorantes , Receptores ErbB , Márgenes de Escisión , Imagen Molecular , Neoplasias de la Boca/diagnóstico por imagen , Neoplasias de la Boca/cirugía , Radiofármacos
10.
Eur J Surg Oncol ; 49(10): 106941, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37442716

RESUMEN

INTRODUCTION: In an era of exploring patient-tailored treatment options for colon cancer, preoperative staging is increasingly important. This study aimed to evaluate completeness and reliability of CT-based preoperative locoregional colon cancer staging in Dutch hospitals. MATERIALS AND METHODS: Patients who underwent elective oncological resection of colon cancer without neoadjuvant treatment in 77 Dutch hospitals were evaluated between 2011 and 2021. Completeness of T-stage was calculated for individual hospitals and stratified based on a 60% cut-off. Concordance between routine CT-based preoperative locoregional staging (cTN) and definitive pathological staging (pTN) was examined. RESULTS: A total of 59,558 patients were included with an average completeness of 43.4% and 53.4% for T and N-stage, respectively. Completeness of T-stage improved from 4.9% in 2011-2014 to 74.4% in 2019-2021. Median completeness for individual hospitals was 53.9% (IQR 27.3-80.5%) and were not significantly different between low and high-volume hospitals. Sensitivity and specificity for T3-4 tumours were relatively low: 75.1% and 76.0%, respectively. cT1-2 tumours were frequently understaged based on a low negative predictive value of 56.8%. Distinction of cT4 and cN2 disease had a high specificity (>95%), but a very low sensitivity (<50%). Positive predictive values of <60% indicated that cT4 and cN1-2 were often overstaged. Completeness and time period did not influence reliability of staging. CONCLUSION: Completeness of locoregional staging of colon cancer improved during recent years and varied between hospitals independently from case volume. Discriminating cT1-2 from cT3-4 tumours resulted in substantial understaging and overstaging, additionally cT4 and cN1-2 were overstaged in >40% of cases.


Asunto(s)
Neoplasias del Colon , Humanos , Reproducibilidad de los Resultados , Estadificación de Neoplasias , Neoplasias del Colon/diagnóstico por imagen , Neoplasias del Colon/cirugía , Neoplasias del Colon/patología , Terapia Neoadyuvante , Tomografía Computarizada por Rayos X/métodos
11.
Diagnostics (Basel) ; 13(9)2023 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-37174982

RESUMEN

(1) Introduction: Near-infrared fluorescence (NIRF) combined with tumour-targeted tracers, such as bevacizumab-800CW, could aid surgical decision-making. This study explored the use of IRDye800CW, conjugated to bevacizumab, with four commercially available NIRF laparoscopes optimised for indocyanine green (ICG). (2) Methods: A (lymph node) phantom was made from a calibration device for NIRF and tissue-mimicking material. Serial dilutions of bevacizumab-800CW were made and ICG functioned as a reference. System settings, working distance, and thickness of tissue-mimicking material were varied to assess visibility of the fluorescence signal and tissue penetration. Tests were performed with four laparoscopes: VISERA ELITE II, Olympus; IMAGE1 S™ 4U Rubina, KARL STORZ; ENDOCAM Logic 4K platform, Richard Wolf; da Vinci Xi, Intuitive Surgical. (3) Results: The lowest visible bevacizumab-800CW concentration ranged between 13-850 nM (8-512 times diluted stock solution) for all laparoscopes, but the tracer was not visible through 0.8 cm of tissue in all systems. In contrast, ICG was still visible at a concentration of 0.4 nM (16,384 times diluted) and through 1.6-2.4 cm of tissue. Visibility and tissue penetration generally improved with a reduced working distance and manually adjusted system settings. (4) Conclusion: Depending on the application, bevacizumab-800CW might be sufficiently visible with current laparoscopes, but optimisation would widen applicability of tumour-targeted IRDye800CW tracers.

12.
United European Gastroenterol J ; 11(4): 324-336, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37095718

RESUMEN

INTRODUCTION: Endoscopic detection of early neoplasia in Barrett's esophagus is difficult. Computer Aided Detection (CADe) systems may assist in neoplasia detection. The aim of this study was to report the first steps in the development of a CADe system for Barrett's neoplasia and to evaluate its performance when compared with endoscopists. METHODS: This CADe system was developed by a consortium, consisting of the Amsterdam University Medical Center, Eindhoven University of Technology, and 15 international hospitals. After pretraining, the system was trained and validated using 1.713 neoplastic (564 patients) and 2.707 non-dysplastic Barrett's esophagus (NDBE; 665 patients) images. Neoplastic lesions were delineated by 14 experts. The performance of the CADe system was tested on three independent test sets. Test set 1 (50 neoplastic and 150 NDBE images) contained subtle neoplastic lesions representing challenging cases and was benchmarked by 52 general endoscopists. Test set 2 (50 neoplastic and 50 NDBE images) contained a heterogeneous case-mix of neoplastic lesions, representing distribution in clinical practice. Test set 3 (50 neoplastic and 150 NDBE images) contained prospectively collected imagery. The main outcome was correct classification of the images in terms of sensitivity. RESULTS: The sensitivity of the CADe system on test set 1 was 84%. For general endoscopists, sensitivity was 63%, corresponding to a neoplasia miss-rate of one-third of neoplastic lesions and a potential relative increase in neoplasia detection of 33% for CADe-assisted detection. The sensitivity of the CADe system on test sets 2 and 3 was 100% and 88%, respectively. The specificity of the CADe system varied for the three test sets between 64% and 66%. CONCLUSION: This study describes the first steps towards the establishment of an unprecedented data infrastructure for using machine learning to improve the endoscopic detection of Barrett's neoplasia. The CADe system detected neoplasia reliably and outperformed a large group of endoscopists in terms of sensitivity.


Asunto(s)
Esófago de Barrett , Aprendizaje Profundo , Neoplasias Esofágicas , Humanos , Esófago de Barrett/diagnóstico , Esófago de Barrett/patología , Neoplasias Esofágicas/diagnóstico , Neoplasias Esofágicas/patología , Esofagoscopía/métodos , Estudios Retrospectivos , Sensibilidad y Especificidad
13.
Cancers (Basel) ; 15(7)2023 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-37046611

RESUMEN

Optical biopsy in Barrett's oesophagus (BE) using endocytoscopy (EC) could optimize endoscopic screening. However, the identification of dysplasia is challenging due to the complex interpretation of the highly detailed images. Therefore, we assessed whether using artificial intelligence (AI) as second assessor could help gastroenterologists in interpreting endocytoscopic BE images. First, we prospectively videotaped 52 BE patients with EC. Then we trained and tested the AI pm distinct datasets drawn from 83,277 frames, developed an endocytoscopic BE classification system, and designed online training and testing modules. We invited two successive cohorts for these online modules: 10 endoscopists to validate the classification system and 12 gastroenterologists to evaluate AI as second assessor by providing six of them with the option to request AI assistance. Training the endoscopists in the classification system established an improved sensitivity of 90.0% (+32.67%, p < 0.001) and an accuracy of 77.67% (+13.0%, p = 0.020) compared with the baseline. However, these values deteriorated at follow-up (-16.67%, p < 0.001 and -8.0%, p = 0.009). Contrastingly, AI-assisted gastroenterologists maintained high sensitivity and accuracy at follow-up, subsequently outperforming the unassisted gastroenterologists (+20.0%, p = 0.025 and +12.22%, p = 0.05). Thus, best diagnostic scores for the identification of dysplasia emerged through human-machine collaboration between trained gastroenterologists with AI as the second assessor. Therefore, AI could support clinical implementation of optical biopsies through EC.

14.
J Nucl Med ; 64(5): 803-808, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36604181

RESUMEN

Esophageal adenocarcinoma causes 6% of cancer-related deaths worldwide. Near-infrared fluorescence molecular endoscopy (NIR-FME) uses a tracer that targets overexpressed proteins. In this study, we aimed to investigate the feasibility of an epidermal growth factor receptor (EGFR)-targeted tracer, cetuximab-800CW, to improve detection of early-stage esophageal adenocarcinoma. Methods: We validated EGFR expression in 73 esophageal tissue sections. Subsequently, we topically administered cetuximab-800CW and performed high-definition white-light endoscopy (HD-WLE), narrow-band imaging, and NIR-FME in 15 patients with Barrett esophagus (BE). Intrinsic fluorescence values were quantified using multidiameter single-fiber reflectance and single-fiber fluorescence spectroscopy. Back-table imaging, histopathologic examination, and EGFR immunohistochemistry on biopsy samples collected during NIR-FME procedures were performed and compared with in vivo imaging results. Results: Immunohistochemical preanalysis showed high EGFR expression in 67% of dysplastic tissue sections. NIR-FME visualized all 12 HD-WLE-visible lesions and 5 HD-WLE-invisible dysplastic lesions, with increased fluorescence signal in visible dysplastic BE lesions compared with nondysplastic BE as shown by multidiameter single-fiber reflectance/single-fiber fluorescence, reflecting a target-to-background ratio of 1.5. Invisible dysplastic lesions also showed increased fluorescence, with a target-to-background ratio of 1.67. Immunohistochemistry analysis showed EGFR overexpression in 16 of 17 (94%) dysplastic BE lesions, which all showed fluorescence signal. Conclusion: This study has shown that NIR-FME using cetuximab-800CW can improve detection of dysplastic lesions missed by HD-WLE and narrow-band imaging.


Asunto(s)
Adenocarcinoma , Esófago de Barrett , Neoplasias Esofágicas , Humanos , Cetuximab , Fluorescencia , Neoplasias Esofágicas/diagnóstico por imagen , Neoplasias Esofágicas/patología , Esófago de Barrett/diagnóstico por imagen , Esófago de Barrett/patología , Endoscopía , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/patología , Receptores ErbB/metabolismo
15.
Clin Gastroenterol Hepatol ; 21(9): 2260-2269.e9, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36423874

RESUMEN

BACKGROUND & AIMS: Although random histological sampling from the esophagogastric junction (EGJ) after complete eradication of Barrett's esophagus (BE) is recommended, its clinical relevance is questionable. This study aimed to assess the incidence and long-term outcomes of findings from random EGJ biopsies in a nationwide cohort with long-term follow-up. METHODS: We included all patients with successful endoscopic eradication therapy (EET), defined as complete endoscopic eradication of all visible BE (CE-BE), for early BE neoplasia from the Dutch registry. Patients were treated and followed-up in 9 expert centers according to a joint protocol. Outcomes included the incidence of intestinal metaplasia (IM) at the EGJ (EGJ-IM) and the association between IM and visible (dysplastic) BE recurrence. RESULTS: A total of 1154 patients were included with a median follow-up of 43 months (interquartile range, 22-69 months). At the time of CE-BE, persisting EGJ-IM was found in 7% of patients (78/1154), which was reproduced during further follow-up in 46% of patients (42/78). No significant association existed between persisting EGJ-IM at CE-BE and recurrent non-dysplastic or dysplastic BE (hazard ratio [HR], 1.15; 95% confidence interval [CI], 0.63-2.13 and HR, 0.73; 95% CI, 0.17-3.06, respectively). Among patients with no EGJ-IM at the time of CE-BE (1043/1154; 90%), EGJ-IM recurred in 7% (72/1043) after a median of 21 months (interquartile range, 15-36 months), and was reproduced during further follow-up in 26% of patients (19/72). No association was found between recurrent EGJ-IM and non-dysplastic or dysplastic recurrence (HR, 1.18; 95% CI, 0.67-2.06 and HR, 0.27; 95% CI, 0.04-1.96, respectively). CONCLUSION: Because EGJ-IM was not associated with a higher risk for recurrent disease, we recommend to consider abandoning random EGJ sampling after successful EET, under the condition that care is provided in expert centers, and the esophagus, including the EGJ, is carefully inspected (Netherlands Trial Register, NL7309).


Asunto(s)
Esófago de Barrett , Ablación por Catéter , Neoplasias Esofágicas , Humanos , Esófago de Barrett/cirugía , Esófago de Barrett/patología , Relevancia Clínica , Recurrencia Local de Neoplasia/epidemiología , Unión Esofagogástrica/patología , Biopsia , Metaplasia/patología , Esofagoscopía , Neoplasias Esofágicas/patología , Resultado del Tratamiento
16.
Mol Imaging Biol ; 25(1): 18-35, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-35764908

RESUMEN

Flexible high-definition white-light endoscopy is the current gold standard in screening for cancer and its precursor lesions in the gastrointestinal tract. However, miss rates are high, especially in populations at high risk for developing gastrointestinal cancer (e.g., inflammatory bowel disease, Lynch syndrome, or Barrett's esophagus) where lesions tend to be flat and subtle. Fluorescence molecular endoscopy (FME) enables intraluminal visualization of (pre)malignant lesions based on specific biomolecular features rather than morphology by using fluorescently labeled molecular probes that bind to specific molecular targets. This strategy has the potential to serve as a valuable tool for the clinician to improve endoscopic lesion detection and real-time clinical decision-making. This narrative review presents an overview of recent advances in FME, focusing on probe development, techniques, and clinical evidence. Future perspectives will also be addressed, such as the use of FME in patient stratification for targeted therapies and potential alliances with artificial intelligence. KEY MESSAGES: • Fluorescence molecular endoscopy is a relatively new technology that enables safe and real-time endoscopic lesion visualization based on specific molecular features rather than on morphology, thereby adding a layer of information to endoscopy, like in PET-CT imaging. • Recently the transition from preclinical to clinical studies has been made, with promising results regarding enhancing detection of flat and subtle lesions in the colon and esophagus. However, clinical evidence needs to be strengthened by larger patient studies with stratified study designs. • In the future fluorescence molecular endoscopy could serve as a valuable tool in clinical workflows to improve detection in high-risk populations like patients with Barrett's esophagus, Lynch syndrome, and inflammatory bowel syndrome, where flat and subtle lesions tend to be malignant up to five times more often. • Fluorescence molecular endoscopy has the potential to assess therapy responsiveness in vivo for targeted therapies, thereby playing a role in personalizing medicine. • To further reduce high miss rates due to human and technical factors, joint application of artificial intelligence and fluorescence molecular endoscopy are likely to generate added value.


Asunto(s)
Esófago de Barrett , Neoplasias Colorrectales Hereditarias sin Poliposis , Humanos , Esófago de Barrett/diagnóstico por imagen , Esófago de Barrett/patología , Inteligencia Artificial , Tomografía Computarizada por Tomografía de Emisión de Positrones , Endoscopía Gastrointestinal/métodos , Endoscopía/métodos , Imagen Molecular/métodos
17.
Eur J Surg Oncol ; 49(1): 106-112, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35963750

RESUMEN

INTRODUCTION: Despite evidence-based guidelines, variation in esophageal cancer care exists in daily practice. Many oncology networks deployed regional agreements to standardize the patient care pathway and reduce unwarranted clinical variation. The aim of this study was to explore the trends in variation of esophageal cancer care between participating hospitals of the Managed Clinical Network (MCN) in the Netherlands. MATERIALS AND METHODS: Patients with esophageal cancer diagnosed from 2012 to 2016 were selected from the Netherlands Cancer Registry. Variation on treatment strategies, lead time to start of treatment, and 2-year survival, were calculated and compared between five clusters of hospitals within the network. RESULTS: A total of 1763 patients, diagnosed in 17 hospitals, were included. 71% of all patients received treatment with a curative intent, which ranged from 69% to 77% between the clusters of hospitals in 2015-2016. Although variation in treatment modalities between the clusters was observed in 2012-2014, no significant variation existed in 2015-2016, except for patients receiving no treatment at all. The 2-year overall survival of patients receiving treatment with a curative intent did not vary significantly between the clusters of hospitals (range: 56%-63%). Nevertheless, the median lead time before patients started treatment with a curative intent varied between clusters of hospitals in 2015-2016 (range: 34-47 days; p < 0.001). CONCLUSION: Limited variation in esophageal cancer treatment between clusters of hospitals in the MCN existed. This study shows that oncology networks can promote standardization of cancer care and reduce variation between hospitals through insight into variation.


Asunto(s)
Neoplasias Esofágicas , Humanos , Resultado del Tratamiento , Terapia Combinada , Hospitales , Países Bajos/epidemiología
19.
Visc Med ; 38(3): 182-188, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35814977

RESUMEN

Background: Esophageal adenocarcinoma (EAC) is one of the main causes of cancer-related deaths worldwide and its incidence is rising. Barrett's esophagus (BE) can develop low- and high-grade dysplasia which can progress to EAC overtime. The golden standard to detect dysplastic BE (DBE) or EAC is surveillance with high-definition white-light endoscopy (HD-WLE) and random biopsies according to the Seattle protocol. However, this method is time-consuming and associated with a remarkable miss rate. Therefore, there is great need for the development of novel reliable techniques to optimize surveillance strategies and improve detection rates. Summary: Optical chromoendoscopy (OC) techniques like narrow-band imaging have shown improved detection of DBE and EAC compared to HD-WLE and random biopsies. Most recent OC techniques, including the iSCAN optical enhancement system and linked color imaging, showed improved characterization of DBE and EAC retrospectively. Fluorescence molecular endoscopy (FME) presented promising results to highlight DBE and EAC. Moreover, with the establishment of well-performing delineation computer-aided detection (CAD) algorithms and the first real-time CAD system for EAC, we expect clinical application of CAD in the near future. Key Messages: Despite impressive progress made in the development of advanced endoscopic techniques, combined HD-WLE/OC followed by random biopsies remains the golden standard for BE surveillance. Surveillance depends on appropriate mucosal cleansing, sufficient inspection time, and competence of the performing gastroenterologist to improve detection of EAC. In addition, to facilitate the clinical implementation of advanced endoscopic techniques, multicenter prospective clinical studies are demanded for OC and FME. Meanwhile, further optimization of CAD algorithms, the education of gastroenterologists, and analysis of the interaction between the clinician and the computer should be performed.

20.
Cancers (Basel) ; 14(13)2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35805012

RESUMEN

Recommendations in Barrett's esophagus (BE) guidelines are mainly based on male patients. We aimed to evaluate sex differences in BE patients in (1) probability of and (2) time to neoplastic progression, and (3) differences in the stage distribution of neoplasia. We conducted a multicenter prospective cohort study including 868 BE patients. Cox regression modeling and accelerated failure time modeling were used to estimate the sex differences. Neoplastic progression was defined as high-grade dysplasia (HGD) and/or esophageal adenocarcinoma (EAC). Among the 639 (74%) males and 229 females that were included (median follow-up 7.1 years), 61 (7.0%) developed HGD/EAC. Neoplastic progression risk was estimated to be twice as high among males (HR 2.26, 95% CI 1.11-4.62) than females. The risk of HGD was found to be higher in males (HR 3.76, 95% CI 1.33-10.6). Time to HGD/EAC (AR 0.52, 95% CI 0.29-0.95) and HGD (AR 0.40, 95% CI 0.19-0.86) was shorter in males. Females had proportionally more EAC than HGD and tended to have higher stages of neoplasia at diagnosis. In conclusion, both the risk of and time to neoplastic progression were higher in males. However, females were proportionally more often diagnosed with (advanced) EAC. We should strive for improved neoplastic risk stratification per individual BE patient, incorporating sex disparities into new prediction models.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA