Dent J (Basel) ; 11(5)2023 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-37232767

RESUMEN

INTRODUCTION: An important and non-adapted delivered energy of Er:YAG laser can eliminate the total thickness of root cementum during root planing. Conversely, the preservation of a partial layer of cementum covering the roots is vital for any periodontal ligament regeneration. Thus, the assessment of the cementum ablation depth produced by each energy density of Er:YAG laser is essential before considering its use for the periodontal planing and treatment of the cementum and root surfaces. AIM OF THE STUDY: Assessment of the cementum ablation depth at different energy densities of the Er:YAG laser is the aim of this study. MATERIALS AND METHODS: A total of 48 human caries free molars were collected and used in this study. Areas to be irradiated were delimited by two longitudinal grooves (0.5 mm depth). Roots were divided randomly into four groups (4 × n = 12). An Er:YAG laser (2.94 µm) was used with a side-firing tip (R600T) with a 600 µm diameter and a frequency of 20 Hz combined with a cooling system of air 6 mL/min and water 4 mL/min. We used a super short pulse mode (SSP: pulse duration: 50 µs). We used a single irradiation passage backward from apex to cervical parts at 1 mm/s with a slight contact and at an angle of 15° to 30° between the tip and the root surface. Different energies were selected: 30 mJ, 40 mJ, 50 mJ, and 60 mJ. RESULTS: Microscopic observations showed that the average of the ablation depth increased with the increase of the delivered energy from 30 mJ to 60 mJ. Mean values of the ablation depths were respectively as follows: 43.75 ± 4.89 µm for the energy of 30 mJ, 50.05 ± 3.72 µm for 40 mJ, 65.56 ± 10.35 µm for 50 mJ, and 74.80 ± 15.23 µm for 60 mJ. A statistically significant difference existed between the ablation depth of all groups. CONCLUSION: Based on our results, the depth of cementum debridement is related to the level of the delivered energy. The lowest energy levels (30 mJ and 40 mJ) can ablate the root cementum surface for a variable depth from 43.75 ± 4.89 µm to 50.05 ± 3.72 µm.

2.
Biomater Investig Dent ; 8(1): 92-103, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34240061

RESUMEN

AIM: To compare the clinical performance of composite restorations placed with a universal adhesive, one-step and two-step self-etch adhesives in class I and II posterior cavities. MATERIALS AND METHODS: In this in vivo study, 46 volunteers presenting with at least three carious lesions were included. Each participant received the three restorative systems: universal adhesive/nanofilled composite (Scotchbond Universal/Filtek Z350 XT: SBU/FZXT), one-step self-etch adhesive/microhybrid composite (G-aenial bond/G-aenial Posterior: GB/GP) and the two-step self-etch adhesive/nanohybrid composite (OptiBond XTR/Herculite Ultra: OBX/HU). The adhesives were all placed in self-etch mode. In total, 138 restorations were evaluated at baseline and at 6,12 and 36 months using the modified United States Public Health Service criteria. Data were analysed using Kruskal-Wallis, Mann-Whitney U, Friedman and Wilcoxon non-parametric tests (p < .05). Ninety-one restorations were evaluated at 36 months. RESULTS: Seven restorations, three SBU/FZXT, three GB/GP and one OBX/HU failed during this study. The reasons for failure were marginal fracture and secondary caries. SBU/FZXT restorations showed significant marginal deterioration in all parameters. Overall success rates were: 93.5% (SBU/FZXT), 96.6% (GB/GP) and 96.8% (OBX/HU). CONCLUSIONS: After three years, the three restorative systems have comparable clinical effectiveness and success rates, except for the marginal integrity, that was suboptimal for both the SBU/FZXT and GB/GP restorations in comparison to the OBX/HU restorations.

3.
Dent J (Basel) ; 8(3)2020 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-32630313

RESUMEN

(1) Background: Bonding composite to tooth structure is still evolving with a substitute for phosphoric acid being the main challenge. Lately, a self-adhering composite (SAC) was developed, promising to simplify bonding to tooth structure. Unfortunately, retention especially to dentin, was not as good as the gold standard three steps bonding system. During the last 2 decades, lasers were used to enhance shear bond strength of composite to tooth structure. However, the literature provided limited information regarding laser efficiency in the immediate, as well as the long term, adhesion success of SACs to dentin. The purpose of our study was to define the optimal irradiation conditions to improve the adhesion of self-adhering flowable resin composite to dentin exposed to Er:YAG and Er,Cr:YSGG laser irradiation. (2) Methods: Seventy-two freshly extracted human third molars, prepared to have flat dentinal surfaces, were randomly divided into three groups (n = 24) including a control group (Group 1) in which dentin was left without laser irradiation. The other two groups (Group 2 and 3) received standardized irradiation at a speed of 1 mm/second with Er:YAG (60 mJ; SSP mode = 50 µs; 10 Hz; fluency of 9.4 J/cm2; beam diameter: 0.9 mm; air 6 mL/min; and water 4 mL/min), and Er,Cr:YSGG: 1.5 W; fluency of 17.8 J/cm2; turbo handpiece with MX5 short insert; 20 Hz under air/water spray (65% air, 55% water). Self-adhering flowable resin was applied to dentin in all groups. Half of the specimens were stored in water for 24 h while the other half underwent 3000 thermal cycles. Later, all specimens received a shear bond strength test. Fracture observation was done first under a stereomicroscope then by using a scanning electron microscope. (3) Results: The mean values of shear bond strength for both laser-treated dentin groups (Er:YAG laser: 13.10 ± 1.291, and Er,Cr:YSGG: 14.04 ± 5.233) were higher than in the control group 1 (8.355 ± 2.297) before thermocycling. After thermocycling, shear bond strength decreased in all groups as follows: 10.03 ± 1.503, 10.53 ± 2.631, and 02.75 ± 1.583 for Er:YAG, Er,Cr:YSGG, and nonirradiated dentin, respectively. Shear bond strength values showed a significant difference between the control group (Group 1) and both lasers groups (Group 2 and 3). Statistical analysis of stereomicroscope observation revealed no significant difference between laser irradiation and failure mode (p < 0.136). SEM observation of the dentin surface in both laser-irradiated groups showed opened tubules, absence of smear layer as well as an increase of resin infiltration into dentinal tubules. (4) Conclusion: Er:YAG and Er,Cr:YSGG lasers enhance self-adhering flowable resin shear bond strength values and improve its longevity by eliminating the smear layer, opening dentinal tubules and increasing resin infiltration into the microstructure.

4.
Med Sci Monit Basic Res ; 26: e923279, 2020 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-32536683

RESUMEN

BACKGROUND The purpose of this study is to evaluate and compare color stability of 3 resin based restorative materials when immersed into staining media at 0, 3, 30, 45, 60, and 75 days, and to assess the efficacy of surface polishing in reducing possible discoloration. MATERIAL AND METHODS Ninety composite discs were prepared in a custom-made mold (5 mm diameter and 2 mm thick) from 3 different light cured composites (Filtek™ Z250, Harmonize™, and G-aenial). Color differences of all specimens were measured by a spectrophotometer according to the CIE L*a*b* system. After baseline color measurements, 30 discs from each composite group were randomly divided into 3 subgroups of 10 specimens each. Subgroups (n=10) were immersed for 75 days into different staining solutions: coffee, tomato sauce, and distilled water (control). Solutions were changed every week and color measurements were repeated every 15 days. At day 75, color measurements of the specimens were performed before and after surface polishing with aluminum oxide discs. The experimental data were statistically evaluated using repeated measures one-way ANOVA test followed by Tukey's multiple pairwise comparison with a significance level of 5%. RESULTS Of the 3 composites, G-aenial reported the highest color change deviation when immersed into coffee (ΔE=8.674), and tomato sauce (ΔE=7.737) at day 75, followed by Harmonize that also exhibited a significant difference for coffee (ΔE=4.7) and tomato sauce (ΔE=3.8) when compared to distilled water. While Filtek™ Z250 did not show any significant difference between the 3 storage solutions (P>0.05). Only G-aenial had significant color change (P<0.05) after polishing with aluminum oxide discs for all tested samples, whereas Filtek™ Z250 and Harmonize presented no significant difference after surface polishing (P>0.05). CONCLUSIONS Under the tested experimental conditions, Filtek™ Z250, among the 3 resin-based composites, exhibited the highest color stability when subjected to coffee and tomato sauce as well. Whereas, G-aenial presented the highest color deviation when immersed in both staining media. Surface polishing effectively reduced coffee and tomato sauce discolorations for G-aenial's specimens and had no significant effect regarding Filtek™ Z250 and Harmonize.


Asunto(s)
Pulido Dental/métodos , Dentífricos/química , Resinas Sintéticas/química , Café/efectos adversos , Color , Colorantes/química , Resinas Compuestas/análisis , Resinas Compuestas/química , Humanos , Solanum lycopersicum/efectos adversos , Ensayo de Materiales/métodos , Resinas Sintéticas/análisis , Espectrofotometría/métodos
5.
J Prosthodont ; 28(2): e744-e751, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29968276

RESUMEN

PURPOSE: The effect of masticatory loads on the retention of overdenture attachments is poorly documented. The aim of this in vitro study is to assess the effect of simulated mastication on the retentive properties and dimensions of Locator inserts. MATERIALS AND METHODS: 30 specimens simulating nonanatomic edentulous flat ridges with two implant replicas each were fabricated. Overdenture units were connected to the implants with Locator attachments and 3 types of inserts: transparent (Group T; n = 10 pairs), pink (Group P; n = 10 pairs), and blue (Group B; n = 10 pairs). The overdenture units were subjected to simulated bi-axial masticatory loads of 68.6 N. Locator retention was assessed using axial dislodging forces at baseline (T0) and following 100,000 (T1) and 200,000 (T2) masticatory cycles. The inner diameter of the insert (XY) and the diameter of the central core (AB) were measured under stereomicroscope at T0 and T2. Retention changes and dimensional variations of the inserts were statistically analyzed. RESULTS: The 3 groups showed significantly different retentions with the highest values recorded for group T followed by group P, and finally group B at T0, T1, and T2. Groups T and P were not affected by loading while group B showed a significant mean retention loss from T0 to T1. XY and AB were significantly different between the 3 color-coded inserts at baseline and at T2. No correlation could be established between retention changes and dimensional variations of the 3 types of inserts. CONCLUSIONS: Within the limitations of this in vitro study, simulated mastication seems to significantly affect the extra-light blue Locator inserts but not the more-retentive ones. The transparent and pink inserts may require less frequent replacements and could therefore be recommended under clinical conditions.


Asunto(s)
Alisadura de la Restauración Dental , Retención de Dentadura , Prótesis de Recubrimiento , Proceso Alveolar , Prótesis Dental de Soporte Implantado , Análisis del Estrés Dental , Humanos , Técnicas In Vitro , Mandíbula , Masticación , Modelos Dentales
6.
Iran Endod J ; 12(4): 454-461, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29225641

RESUMEN

INTRODUCTION: The present in vitro study aimed to evaluate and compare the changes in shape and surface area of the major foramen following shaping of curved canals with three new generation NiTi engine-driven instruments naming ProTaper Next, BT RaCe and WaveOne Gold- with 3 different levels of protrusion beyond the major apical foramen. METHODS AND MATERIALS: A total of 45 extracted human molars with at least one curved canal were distributed in 3 comparable groups of 15 that were instrumented using either ProTaper Next (PTN), BT RaCe (BTR) or WaveOne Gold (WOG). The canals were instrumented to the major foramen and then over instrumented with the final file 0.5 mm, 1 mm and 1.5 mm beyond the foramen. Standardized pre- and post-instrumentation photographs of the foramen were obtained for all groups using a stereomicroscope. Foramen shape and surface area were evaluated using the AmScope software for measurements and compared between groups and levels of instrumentation applying binary conditional logistic regression and repeated measures ANOVA. The level of significance was set at 0.05. RESULTS: Foramen shape tended to gradually change from circular to oval as the level of instrumentation increased in all groups. The original foramen shape in WOG group remained better than other groups. Foramen surface areas increased in all groups with Group BTR demonstrating significantly greater values than the other 2 groups. CONCLUSION: Over instrumentation resulted in apical enlargement and ovalization in all 3 groups but with different patterns. These differences can be attributed to the final file size, design characteristics and kinematics of the 3 systems.

7.
Biomed Res Int ; 2016: 6507924, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27830151

RESUMEN

Objective. To investigate the shear bond strength of self-adhering flowable resin composite, to dentin, after exposing it to Er:YAG laser radiation, at different energy densities. Materials and Methods. Sixty freshly extracted human third molars were randomly divided into five groups (n = 12). In the control group, dentin was left unirradiated, whereas, in the other four groups, dentin was irradiated with Er:YAG laser in noncontact mode (MSP mode = 100 µs; 10 Hz; beam diameter: 1.3 mm; speed of 1 mm/second; air 6 mL/min; and water 4 mL/min), and respectively, with the following level of energy (50 mJ, 60 mJ, 80 mJ, and 100 mJ). Then, self-adhering flowable resin composite was bonded to all prepared dentin surfaces. Shear bond strength (SBS) was applied and fractured surfaces were examined using scanning electron microscopy. Results. SBS values showed significant differences in 60 mJ (P < 0.05) compared to other groups. Morphological evaluation revealed tags or plugs in dentinal tubules, especially when 60 mJ and 80 mJ were used. All four groups tended to leave more residues on the dentin surface, than the control group. Conclusion. Er:YAG dentin irradiation may enhance SBS of the self-adhering flowable resin composite when it is used at the appropriate low level of energy density.


Asunto(s)
Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Cementos Dentales/química , Dentina/química , Láseres de Estado Sólido , Diente Molar/química , Grabado Ácido Dental , Aire , Humanos , Microscopía Electrónica de Rastreo , Distribución Aleatoria , Cementos de Resina/química , Robótica , Resistencia al Corte , Resistencia a la Tracción , Agua/química