Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
1.
Bone Joint J ; 106-B(3 Supple A): 104-109, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38425294

RESUMEN

Aims: Femoral component anteversion is an important factor in the success of total hip arthroplasty (THA). This retrospective study aimed to investigate the accuracy of femoral component anteversion with the Mako THA system and software using the Exeter cemented femoral component, compared to the Accolade II cementless femoral component. Methods: We reviewed the data of 30 hips from 24 patients who underwent THA using the posterior approach with Exeter femoral components, and 30 hips from 24 patients with Accolade II components. Both groups did not differ significantly in age, sex, BMI, bone quality, or disease. Two weeks postoperatively, CT images were obtained to measure acetabular and femoral component anteversion. Results: The mean difference in femoral component anteversion between intraoperative and postoperative CT measurements (system accuracy of component anteversion) was 0.8° (SD 1.8°) in the Exeter group and 2.1° (SD 2.3°) in the Accolade II group, respectively (p = 0.020). The mean difference in anteversion between the plan and the postoperative CT measurements (clinical accuracy of femoral component anteversion) was 1.2° (SD 3.6°) in the Exeter group, and 4.2° (SD 3.9°) in the Accolade II group (p = 0.003). No significant differences were found in acetabular component inclination and anteversion; however, the clinical accuracy of combined anteversion was significantly better in the Exeter group (0.6° (SD 3.9°)) than the Accolade II group (3.6° (SD 4.1°)). Conclusion: The Mako THA system and software helps surgeons control the femoral component anteversion to achieve the target angle of insertion. The Exeter femoral component, inserted using Mako THA system, showed greater precision for femoral component and combined component anteversion than the Accolade II component.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Procedimientos Quirúrgicos Robotizados , Humanos , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Masculino , Femenino
2.
J Artif Organs ; 2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-38195733

RESUMEN

Research is lacking on the effect of intraoperative pelvic tracker displacement relative to the pelvis on cup orientation accuracy in computed tomography (CT)-based navigation (CTN) or multivariable analysis to detect factors associated with CTN accuracy. Here, we asked: (1) how pelvic tracker displacement influences the CTN accuracy of cup orientation in total hip arthroplasty (THA)? and (2) what factors are associated with CTN accuracy on multivariable analysis? Regarding cup orientation in 446 THA procedures using CTN, we evaluated clinical error defined as the difference between postoperative measurement and preoperative planning and measurement error defined as the difference between postoperative and intraoperative measurements. Multivariable regression analyses detected the associated factors. Subjects with an intraoperative tracker displacement of < 2 mm were classified in the verified group. Mean absolute clinical and measurement errors were < 1.5° in the verified group, whereas the measurement error of 2.6° for cup inclination and 1.3° for anteversion was larger in the non-verified versus verified group. Tracker displacement and screw fixation were associated with larger clinical errors, while tracker displacement and surgeon inexperience were associated with larger measurement errors. Clinical and measurement accuracies were high for CTN cup placement with rigid pelvic tracker fixation.

3.
J Orthop Sci ; 28(6): 1392-1399, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36163118

RESUMEN

BACKGROUND: The Japanese Orthopaedic Association National Registry (JOANR) was recently launched in Japan and is expected to improve the quality of medical care. However, surgeons must register ten detailed features for total hip arthroplasty, which is labor intensive. One possible solution is to use a system that automatically extracts information about the surgeries. Although it is not easy to extract features from an operative record consisting of free-text data, natural language processing has been used to extract features from operative records. This study aimed to evaluate the best natural language processing method for building a system that automatically detects some elements in the JOANR from the operative records of total hip arthroplasty. METHODS: We obtained operative records of total hip arthroplasty (n = 2574) in three hospitals and targeted two items: surgical approach and fixation technique. We compared the accuracy of three natural language processing methods: rule-based algorithms, machine learning, and bidirectional encoder representations from transformers (BERT). RESULTS: In the surgical approach task, the accuracy of BERT was superior to that of the rule-based algorithm (99.6% vs. 93.6%, p < 0.001), comparable to machine learning. In the fixation technique task, the accuracy of BERT was superior to the rule-based algorithm and machine learning (96% vs. 74%, p < 0.0001 and 94%, p = 0.0004). CONCLUSIONS: BERT is the most appropriate method for building a system that automatically detects the surgical approach and fixation technique.


Asunto(s)
Inteligencia Artificial , Ortopedia , Humanos , Algoritmos , Sistema de Registros , Japón , Procedimientos Quirúrgicos Operativos , Registros Médicos , Aprendizaje Automático
4.
J Artif Organs ; 23(3): 247-254, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32072330

RESUMEN

This study aimed to investigate whether use of a computed tomography (CT)-based navigation system reduce the risk of dislocation after total hip arthroplasty (THA) in patients with osteonecrosis of the femoral head (ONFH). A total of 271 hips from 192 consecutive patients that underwent primary THA for ONFH were included. There were 110 hips in non-navigation group, and 161 hips in navigation group. After applying exclusion criteria, 209 hips from 149 patients were selected for analysis. Clinical outcomes and complication rates were evaluated, and implant alignments were also calculated. To identify whether the navigation system was useful to prevent dislocation, the inverse probability of treatment-weighted Cox regression analysis using a propensity score in relationship to sex, age at surgery, body mass index, and femoral head size was performed. No significant difference was observed in clinical scores between both groups. Dislocation was significantly lower in the navigation group (3 hips, 2.7%) than in the non-navigation group (11 hips, 11.2%; p = 0.012), whereas periprosthetic joint infection and aseptic loosening did not differ between the groups. Variance of cup inclination and anteversion angles was smaller in the navigation group than in the non-navigation group (p < 0.001). Use of the CT-based navigation system (hazard ratio; 0.26, 95% confidence interval, 0.07-0.98; p = 0.047) turned out to be the predictor for preventing dislocation. In conclusion, use of the CT-based navigation system provided a precise placement of components, and thus helps to prevent dislocation in patients with ONFH in the propensity score analysis.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Necrosis de la Cabeza Femoral/diagnóstico por imagen , Necrosis de la Cabeza Femoral/cirugía , Luxaciones Articulares/prevención & control , Cirugía Asistida por Computador/efectos adversos , Tomografía Computarizada por Rayos X , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Necrosis de la Cabeza Femoral/complicaciones , Articulación de la Cadera/cirugía , Prótesis de Cadera , Humanos , Luxaciones Articulares/etiología , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Estudios Retrospectivos , Cirugía Asistida por Computador/métodos
5.
J Arthroplasty ; 35(2): 563-568, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31551160

RESUMEN

BACKGROUND: It is not clear how to treat asymptomatic deep venous thromboses (DVTs) following elective hip arthroplasty because the natural course of DVTs is unclear. It is therefore valuable to understand the natural course of DVTs and their relation to thromboprophylactic methods. METHODS: We followed 742 consecutive patients who underwent elective hip arthroplasty followed by mechanical or chemical prophylaxis of a DVT. All patients underwent preoperative and postoperative duplex ultrasonography of both limbs. Patients who developed postoperative DVT in the popliteal or calf vein were followed without thromboprophylaxis. DVT-positive patients were prospectively followed up with duplex ultrasonography at 3, 6, 12, and 24 months postoperatively. RESULTS: Incidences of preoperative and postoperative DVTs were 3.9% and 33.0%, respectively. Nonfatal pulmonary embolism (PE) occurred in 1 patient after negative echography. All DVTs that developed in the calf vein postoperatively and without anticoagulation remained benign, and 93% of the DVTs ultimately disappeared. CONCLUSION: These results confirmed that the natural course of asymptomatic distal DVTs is benign, with no risk of leading to PE. Thus, distal DVTs could be allowed to remain untreated without chemical prophylaxis to prevent PE in Asian populations.


Asunto(s)
Embolia Pulmonar , Tromboembolia Venosa , Trombosis de la Vena , Anticoagulantes/uso terapéutico , Procedimientos Quirúrgicos Electivos , Estudios de Seguimiento , Humanos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control , Factores de Riesgo , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/epidemiología
6.
J Artif Organs ; 22(4): 324-329, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31278428

RESUMEN

We evaluated the course of the femoral blood vessels of patients with acetabular dysplasia. Patients were divided into five groups: those with Crowe type I, II, III, and IV dysplastic hips and those with normal hips. A computed tomography-based hip navigation software was used to measure the distance between the femoral blood vessels and the anterior pelvic wall in four axial planes located 10-40 mm proximal to the pelvic teardrop. In Crowe Groups I through IV, the distance was shortest at a point 20 mm proximal to the pelvic teardrop. Furthermore, the distance decreased as the Crowe classification grade increased. Because the femoral blood vessels pass close to the pelvis in many patients in Crowe III and IV hips, caution is required during surgery in these patients.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Arteria Femoral/lesiones , Vena Femoral/lesiones , Luxación de la Cadera/cirugía , Complicaciones Intraoperatorias/etiología , Lesiones del Sistema Vascular/etiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Arteria Femoral/diagnóstico por imagen , Vena Femoral/diagnóstico por imagen , Luxación de la Cadera/diagnóstico , Humanos , Incidencia , Complicaciones Intraoperatorias/diagnóstico , Complicaciones Intraoperatorias/epidemiología , Japón/epidemiología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico , Lesiones del Sistema Vascular/epidemiología
7.
J Exp Orthop ; 6(1): 15, 2019 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-30937670

RESUMEN

BACKGROUND: The control of diabetes mellitus (DM) should help reduce the incidence of periprosthetic joint infection (PJI). Self-monitoring of blood glucose (SMBG) concentration is usually undertaken at fixed time-points. Therefore, the extent of postoperative blood glucose fluctuation might be underestimated. To provide a more comprehensive assessment, continuous glucose monitoring (CGM) is beginning to be used. However, no previous studies have evaluated blood glucose concentrations using CGM following orthopedic surgery. Therefore, the differences between the maximum blood glucose concentrations measured using SMBG and CGM, and the mean amplitude of the glycemic fluctuation in patients with frank diabetes mellitus (DM) or pre-diabetes were evaluated. Blood glucose was measured in 20 patients who had undergone total hip or total knee arthroplasty (12 patients with DM and eight with pre-diabetes). Patients were fitted with a CGM device in the operating room, which was worn for 6 days postoperatively, and used to evaluate blood glucose concentration continuously. SMBG was performed simultaneously for the same period. RESULTS: The mean difference between the maximum blood glucose concentrations measured using SMBG and CGM was 25.0 ± 20.3 mg/dl (range, - 17 to 81 mg/dl), with the concentrations measured using CGM tending to be higher than those measured using SMBG (P = 0.04). Blood glucose concentrations measured using CGM tended to be higher than those measured using SMBG until postoperative day 2, and to decrease gradually after postoperative day 4. There were no significant differences in the standard deviation of the blood glucose concentrations between the two groups. CONCLUSIONS: Blood glucose concentrations > 200 mg/dl and larger fluctuations were more frequently recorded using CGM than SMBG, especially until postoperative day 2. Thus, CGM is more useful for the identification of high blood glucose concentrations and larger fluctuations. However, this information was not provided in real time.

8.
J Artif Organs ; 22(1): 84-90, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30251057

RESUMEN

The aim was to elucidate the differences in activities of daily living (ADL) after hip arthroplasty among hip resurfacing (HRA), anterolateral total hip arthroplasty (AL-THA), and posterolateral THA (PL-THA) patients after age, sex, body mass index, bilateral/unilateral hip arthroplasty, and postoperative duration were matched using propensity scores. A total of 673 hips from 540 consecutive patients who underwent hip arthroplasty were included. A self-completed questionnaire on preoperative and postoperative ADLs was administered during postsurgical visits at least ≥ 4 years postoperatively. Between HRA and PL-THA patients, the numbers of patients who performed heels-down squatting was significantly more in HRA than in PL-THA. Between AL-THA and PL-THA patients, there were significant differences in postoperative ADLs including bathing in a bathtub, riding on a train/bus, cutting toenails, bowing while straight sitting, heels-up/down squatting, riding on a bicycle, driving a car, and domestic travel. There were no significant differences in postoperative ADLs between ≥ 36 mm head and ≤ 32 mm head PL-THA patients, and between AL-THA and HRA patients. This propensity score matched study indicated that AL-THA and HRA patients were more active postoperatively than PL-THA patients.


Asunto(s)
Actividades Cotidianas , Artroplastia de Reemplazo de Cadera/rehabilitación , Complicaciones Posoperatorias/rehabilitación , Puntaje de Propensión , Encuestas y Cuestionarios , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reoperación , Resultado del Tratamiento
9.
Clin Orthop Relat Res ; 476(11): 2169-2173, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30179958

RESUMEN

BACKGROUND: Robotic-assisted THA has been promoted as potentially advantageous due to the precision it may afford when machining the proximal femur. However, few reports have compared the long-term clinical results of robotic techniques for femoral component insertion during THA regarding clinical outcomes scores or loosening. QUESTIONS/PURPOSES: The purpose of this study was to compare results from a randomized clinical trial (RCT) at a minimum followup of 10 years between robot-assisted and hand-rasped stem implantation techniques with regard to (1) Japanese Orthopaedic Association (JOA) clinical outcomes scores, and (2) aseptic loosening, revision surgery, and heterotopic ossification. METHODS: This is a concise followup of a previously reported RCT. In that trial, robot-assisted primary THA was performed on 75 hips (69 patients), and a hand-rasping technique was used on 71 hips (61 patients). Five experienced surgeons at two institutions participated in this trial; all THAs were performed through the posterolateral approach and the patients were treated similarly apart from the method used to prepare the femur. In all, 115 of 130 (88%) of patients initially randomized were available for followup at a minimum of 10 years (mean, 135 months; range, 120-152 months). There was no differential loss to followup between the study groups, and the final study groups here included 64 hips in 59 patients in the robotic group, and 64 hips in 56 patients in the hand-milling group. There were no differences between the study groups in terms of age, sex, diagnosis, body-mass index, or baseline JOA scores. The primary study endpoint was the JOA score, which is scored from 0 to 100, with higher scores representing better function and less pain. Secondary outcomes were revision surgery, and radiographic signs of aseptic loosening and heterotopic ossification as assessed using the four-grade Brooker scale by individuals other than the operating surgeon. RESULTS: At a minimum of 10 years postoperatively, there were no differences between patients treated with robot-assisted surgery or hand rasping in JOA scores (97 ± 5 versus 96 ± 7, mean difference 1.4; p = 0.159). No stems in either group developed aseptic loosening, and there were no revisions in either group. There was no difference between the groups in heterotopic ossification (19 of 64 [30%] in the robot-assisted group versus 12 of 64 [19%] in the hand-rasping group; p = 0.186), severe heterotopic ossification was uncommon in both groups, and no hips developed Grade 4 heterotopic ossification in either group. CONCLUSIONS: Clinically and radiographically, THAs performed with robotic milling for stem implantation did not result in better 10-year clinical outcomes scores, or a lower risk of loosening or revision, compared with hand-rasping. We recommend against widespread adoption of robotic milling for stem implantation in primary cementless THAs. LEVEL OF EVIDENCE: Level II, therapeutic study.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Articulación de la Cadera/cirugía , Prótesis de Cadera , Procedimientos Quirúrgicos Robotizados/instrumentación , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Fenómenos Biomecánicos , Femenino , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/fisiopatología , Humanos , Japón , Masculino , Persona de Mediana Edad , Osificación Heterotópica/etiología , Osificación Heterotópica/cirugía , Diseño de Prótesis , Falla de Prótesis/etiología , Rango del Movimiento Articular , Recuperación de la Función , Reoperación , Factores de Riesgo , Procedimientos Quirúrgicos Robotizados/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
10.
J Artif Organs ; 20(2): 152-157, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28243756

RESUMEN

The purpose of this study was to evaluate the outcome improvements after total hip arthroplasty (THA) using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) in patients who underwent THA with a navigation system in our institutions. The subjects were 219 patients. All patients had adequate data to allow complete scoring of the WOMAC for a 1-year postoperative follow-up. CT-based navigation was used in all THAs. Postoperatively, no restrictions were imposed on patients' ADL. One year after surgery, the average WOMAC pain subscale score was 1.8 ± 2.9, the stiffness subscale score was 1.1 ± 1.6, and the physical function subscale score was 7.5 ± 11.6 points. The number of patients whose score for the WOMAC physical function score was 0 points was 61 (27.9%). A lower WOMAC score usually represents a better status. In some of the most difficult functions, such as ascending stairs, bending to the floor, putting on socks/stockings, and heavy domestic duties, the scores tended to be higher than the other scores postoperatively. These results show that THA using navigation can improve patients' postoperative QOL.


Asunto(s)
Actividades Cotidianas , Artroplastia de Reemplazo de Cadera , Osteoartritis de la Cadera/diagnóstico por imagen , Osteoartritis de la Cadera/cirugía , Cirugía Asistida por Computador , Tomografía Computarizada por Rayos X , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/fisiopatología , Calidad de Vida , Recuperación de la Función , Estudios Retrospectivos , Resultado del Tratamiento
11.
J Bone Miner Metab ; 35(4): 412-418, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27550182

RESUMEN

The purpose of this study was to clarify bone turnover marker levels in rapidly destructive coxopathy (RDC). Twenty patients with RDC (mean age, 72 ± 11 years; 3 men, 17 postmenopausal women), 111 with osteoarthritis (OA) (age, 60 ± 10 years; 15 men, 13 premenopausal women, 83 postmenopausal women), and 18 with osteonecrosis of femoral head (ON) (55 ± 14 years; 11 men, 3 premenopausal women, 4 postmenopausal women), and 100 patients with femoral neck fracture (FNF) (81 ± 10 years; 27 men, 73 postmenopausal women) were included. Serum tartrate-resistant acid phosphatase 5b (TRACP-5b), bone alkaline phosphatase (BAP), matrix metalloproteinase-3 (MMP-3) levels, and bone mineral density (BMD) of proximal femur and lumbar spine were investigated. TRACP-5b levels were significantly higher in RDC than in OA and ON, whereas BAP levels were higher in RDC than in OA (P < 0.05). MMP-3 levels were higher in RDC and ON than in OA (P < 0.05). TRACP-5b were higher in RDC than OA (P < 0.05) and FNF (P < 0.05) in performing propensity score matching; there were no differences in BMD between RDC and OA. TRACP-5b showed the largest area under the curve (AUC, 0.82) according to receiver operating characteristic (ROC) curve analysis for diagnosing RDC against OA and ON. AUCs of BAP and MMP-3 were 0.78 and 0.74. The respective sensitivities and specificities were 70.0 % and 85.3 % for TRACP-5b (cutoff, 623 mU/dl), 95.0 % and 57.1 % for BAP (13.8 U/l), and 70.0 % and 76.4 % for MMP-3 (52.7 ng/ml). The lack of differences in BMD suggested that high bone turnover marker levels may reflect osteoclast cell activation in RDC hips. Serum TRACP-5b and BAP could be RDC markers.


Asunto(s)
Biomarcadores/sangre , Enfermedades Óseas/sangre , Remodelación Ósea , Adulto , Anciano , Fosfatasa Alcalina/sangre , Densidad Ósea , Enfermedades Óseas/enzimología , Estudios de Cohortes , Femenino , Fracturas del Cuello Femoral/sangre , Fracturas del Cuello Femoral/enzimología , Humanos , Masculino , Metaloproteinasa 3 de la Matriz/sangre , Persona de Mediana Edad , Osteoartritis/sangre , Osteoartritis/enzimología , Puntaje de Propensión , Curva ROC , Fosfatasa Ácida Tartratorresistente/sangre
12.
Comput Assist Surg (Abingdon) ; 21(1): 132-136, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27973946

RESUMEN

PURPOSE: While implant impingement and bony impingement have been recognized as causes of poor outcomes in total hip arthroplasty (THA), reports of soft-tissue impingement are rare. To clarify the issue, the effect of anterior capsule resection on hip range of motion (ROM) was quantitatively measured in vivo during posterior approach THA using a CT-based hip navigation system. MATERIALS AND METHODS: For 47 patients (51 hips), hip ROM was measured intraoperatively before and after resection of the anterior hip capsule, and the difference was compared. RESULTS: Resection of the anterior hip capsule brought about an average 6° increase of ROM in the direction of flexion with internal rotation and did not markedly change ROM in other directions. CONCLUSIONS: During THA through a posterior approach, soft-tissue impingement by the anterior hip capsule can occur. Clinically, we expect that resection of the anterior hip capsule can reduce the risk of posterior instability without increasing the risk of anterior instability.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Pinzamiento Femoroacetabular/prevención & control , Cápsula Articular/cirugía , Osteoartritis de la Cadera/cirugía , Complicaciones Posoperatorias/prevención & control , Rango del Movimiento Articular/fisiología , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios de Cohortes , Estudios Controlados Antes y Después , Femenino , Pinzamiento Femoroacetabular/etiología , Humanos , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Osteoartritis de la Cadera/fisiopatología , Complicaciones Posoperatorias/etiología , Tomografía Computarizada por Rayos X
14.
J Thromb Thrombolysis ; 41(3): 413-21, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26184606

RESUMEN

Some studies have cautioned about the possibility of bleeding complications with routine use of anticoagulants like fondaparinux (FPX) for thrombophylaxis after elective hip surgery. Overdosing or prolonged periods of anticoagulant use should be avoided. We trialed a new regimen using FPX and tranexamic acid (TA) to reduce the risk of bleeding complications while maintaining efficacy in preventing deep vein thrombosis (DVT). The present study evaluated the effectiveness and safety of this regimen in 391 consecutive patients. Each patient was assigned either the FPX group, administered a once-daily subcutaneous injection of 1.5 mg of FPX on postoperative days 2, 3, and 4; or the intermittent pneumatic compression (IPC) group, which used an IPC device continuously for 1-2 days with no administration of any anticoagulant drugs. Ultrasonography was performed to diagnose DVT in all patients. No cases of fatal or symptomatic pulmonary embolism were encountered in either group, but six patients (3.1 %) in the FPX group and nine patients (6.0 %) in the IPC group showed asymptomatic distal DVT. The incidence of DVT tended to be lower (p = 0.19), volumes of intraoperative (p < 0.01) and postoperative (p < 0.01) blood loss were significantly smaller, and hemoglobin level was significantly higher in the FPX group than in the IPC group (p < 0.01). Our new thrombophylactic regimen using FPX and TA appears effective and safe for use after elective hip surgery.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Procedimientos Quirúrgicos Electivos/efectos adversos , Polisacáridos/administración & dosificación , Complicaciones Posoperatorias/prevención & control , Trombosis de la Vena/prevención & control , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Fondaparinux , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Trombosis de la Vena/etiología
15.
J Arthroplasty ; 30(10): 1761-6, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25956522

RESUMEN

The purpose of this study was to investigate the effects of different surgical approaches, the posterolateral approach (PLA) and the direct anterior approach (DAA), on postoperative femoral anteversion and stem coronal and sagittal alignment in total hip arthroplasty (THA), and to identify the factors related to postoperative femoral anteversion and stem alignment. A total of 209 hips of 181 patients were evaluated. THA was performed through the PLA in 80 hips and through the DAA in 129 hips. Femoral anteversion and stem alignment were measured on postoperative computed tomography images. The factor related to postoperative anteversion change was preoperative femoral anteversion, and the surgical approaches did not affect the postoperative anteversion change, while surgical approach did have an effect on stem sagittal alignment.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Articulación de la Cadera/fisiología , Prótesis de Cadera , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fémur/diagnóstico por imagen , Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Adulto Joven
16.
J Arthroplasty ; 30(9): 1561-4, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25913560

RESUMEN

The purpose of this study was to compare the accuracy of a mechanical cup alignment guide using CT-based navigation between a direct anterior approach (DAA) in both supine and lateral positions and a posterior approach (PA) in the lateral position. A trial cup was placed with a mechanical guide that aimed at 47° of radiographic inclination and 14° of anteversion. The average cup inclination and anteversion were measured using CT-based navigation. The average radiographic anteversion in the DAA supine and lateral group was larger, and that in the PA group was smaller than the target angle. In conclusion, there are no differences in the accuracy or precision of cup angles among the DAA supine, DAA lateral position, and PA groups using a mechanical guide.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Posicionamiento del Paciente , Reproducibilidad de los Resultados , Cirugía Asistida por Computador , Tomografía Computarizada por Rayos X
17.
Am J Sports Med ; 42(1): 131-7, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24114754

RESUMEN

BACKGROUND: Jogging has been classified as a high-impact sport, and jogging after total hip arthroplasty (THA) has not been well documented. PURPOSE: To investigate the participation rate for postoperative jogging as well as jogging parameters and the influence of jogging on implant stability and bearing wear. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: Included in this study were 804 hips in 608 patients (85 men, 523 women) who underwent THA between 2005 and 2011 with follow-up longer than 1 year. The mean patient age was 62 years (range, 26-98 years), and mean follow-up duration was 4.8 years (range, 2.3-7.8 years). Hip resurfacing arthroplasty (HRA) was performed in 81 patients and conventional THA in 527 patients. During routine postsurgical visits, patients were given a questionnaire concerning preoperative and postoperative jogging routines. For joggers, frequency, distance, duration, and velocity of jogging were recorded. Patients who did not jog postoperatively were asked to provide reasons for not jogging. Radiographs concerning implant migration and polyethylene wear were evaluated with specialized software, and serum cobalt and chromium ion concentrations were investigated for patients with metal-on-metal articulation. RESULTS: A total of 33 patients (5.4%) performed jogging preoperatively, and 23 patients (3.8%) performed jogging postoperatively. Of the 23 who jogged postoperatively, conventional THA was performed in 13 patients and HRA in 10 patients. Postoperatively, joggers trained a mean of 4 times (range, 1-7 times) per week, covering a mean distance of 3.6 km (range, 0.5-15 km) in a mean time of 29 minutes (range, 5-90 minutes) per session and at a mean speed of 7.7 km/h (range, 3-18 km/h). No patient complained of pain or showed serum cobalt and chromium ion elevation greater than 7 ppb. No hip showed loosening, abnormal component migration, or excessive wear at a mean 5-year follow-up. There were 74 postoperative non-joggers with an interest in jogging. The reasons given for avoiding jogging included anxiety (45 patients; 61%); impossible because of several reasons, including pain, decreased range of motion, and muscle weakness (18 patients; 24%); and lumbar or knee pain (11 patients; 15%). Multivariate analysis revealed that male sex and a history of preoperative jogging demonstrated significant relationships with postoperative jogging. CONCLUSION: A total of 3.8% of THA patients participated in postoperative jogging. Short-term postoperative follow-up did not identify any negative influence of jogging on implant survival.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Cromo/sangre , Cobalto/sangre , Femenino , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Trote/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Radiografía , Recuperación de la Función , Encuestas y Cuestionarios
18.
Rheumatology (Oxford) ; 53(1): 165-72, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24136066

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate cytokine level characteristics in the hip joint fluid, including rapidly destructive coxopathy (RDC), OA, osteonecrosis (ON) of the femoral head and RA. METHODS: Thirty-three hips with RDC, 57 with OA, 36 with ON and 10 with RA were included in the study. OA hips were divided into two groups: 20 hips with early OA without joint space narrowing and 37 hips with terminal OA. ON hips were divided into three groups: 13 hips with <3 mm collapse, 14 hips with >3 mm collapse and 9 hips with terminal ON. Joint fluid was collected during surgery. Cytokine levels including IL-1ß, IL-6, IL-8 and TNF-α were measured using homogeneous time-resolved fluorescence. RESULTS: All measured cytokine levels in RDC were significantly higher than those in OA (P < 0.05). Terminal OA showed higher cytokine levels than those in early OA (P < 0.05). IL-6 and TNF-α levels in the ON group with >3 mm collapse were higher than those found in the ON group with <3 mm collapse. In comparing cytokine levels between RDC, terminal OA, RA and terminal ON, RDC showed significantly higher IL-8 levels than terminal OA and RA (P < 0.05). CONCLUSION: IL-8 levels in RDC were higher than in the other hip diseases. The IL-8 level may reflect the aggressiveness of joint destruction in RDC, and IL-6 and TNF-α levels may also reflect ongoing destruction in OA and ON.


Asunto(s)
Citocinas/metabolismo , Osteoartritis de la Cadera/metabolismo , Líquido Sinovial/química , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/metabolismo , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Adulto Joven
19.
J Cataract Refract Surg ; 40(2): 251-8, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24345530

RESUMEN

PURPOSE: To evaluate the clinical outcomes of laser in situ keratomileusis (LASIK) to correct myopia or myopic astigmatism using the Amaris 750S 750 Hz excimer laser. SETTING: Private LASIK center, Tokyo, Japan. DESIGN: Case series. METHODS: Patients with myopia or myopic astigmatism (spherical equivalent -0.50 to -11.63 diopters [D]), a corrected distance visual acuity (CDVA) of 20/20 or better, and an estimated residual bed thickness of 300 µm or more had LASIK using the aspheric aberration-free ablation profile of the 750 Hz scanning-spot laser and the Femto LDV Crystal Line femtosecond laser for flap creation. Study parameters included uncorrected distance visual acuity (UDVA), CDVA, manifest refraction, astigmatism, and higher-order aberrations (HOAs). RESULTS: The study included 1280 eyes (685 patients). At 3 months, 96.6% of eyes had a UDVA of 20/20 or better and 99.1% had 20/32 or better; 94.1% of eyes were within ± 0.50 D of the intended correction and 98.9% were within ± 1.00 D; 89.7% of eyes had no residual cylinder and 96.0% had a postoperative astigmatism of less than 0.50 D. All eyes had a postoperative CDVA of 20/20 or better. The HOAs increased postoperatively (P<.001), with mean total postoperative corneal and ocular HOAs of 0.66 µm ± 0.20 (SD) and 0.56 ± 0.23 µm, respectively. The efficacy index and safety index were 1.02 and 1.06, respectively. CONCLUSION: Laser in situ keratomileusis with the 750 Hz scanning-spot laser was safe, effective, and predictable. No specific clinical side effects that might be associated with a high repetition rate occurred. FINANCIAL DISCLOSURE: Mr. Magnago is an employee of Schwind eye-tech-solutions GmbH. No other author has a financial or proprietary interest in any material or method mentioned.


Asunto(s)
Astigmatismo/cirugía , Queratomileusis por Láser In Situ/métodos , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Adolescente , Adulto , Anciano , Astigmatismo/fisiopatología , Córnea/fisiopatología , Aberración de Frente de Onda Corneal/fisiopatología , Femenino , Humanos , Queratomileusis por Láser In Situ/efectos adversos , Láseres de Excímeros/efectos adversos , Masculino , Persona de Mediana Edad , Miopía/fisiopatología , Refracción Ocular/fisiología , Estudios Retrospectivos , Colgajos Quirúrgicos , Resultado del Tratamiento , Agudeza Visual/fisiología , Adulto Joven
20.
J Am Soc Echocardiogr ; 27(2): 200-7, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24345631

RESUMEN

BACKGROUND: The aim of this study was to test whether acceleration time of systolic coronary flow velocity could contribute to the diagnosis of coronary stenosis in patients with microvascular dysfunction, on the basis of the hypothesis that systolic coronary flow is less influenced by microvascular function because of compressed myocardium. METHODS: Coronary flow velocity was assessed in the left anterior descending coronary artery during hyperemia with intravenous adenosine by echocardiography in 502 patients who were scheduled for coronary angiography because of coronary artery disease and significant valvular disease. Coronary flow velocity reserve (CFVR) and the percentage acceleration time (%AT), as the percentage of the time from the beginning to the peak of systolic coronary flow over systolic time during hyperemia, were calculated. The diagnostic ability of CFVR and %AT for angiographic coronary artery stenosis was then analyzed. As invasive substudies, fractional flow reserve and %AT by a dual-sensor (pressure and Doppler velocity) guidewire were measured simultaneously with %AT on transthoracic echocardiography (n = 14). RESULTS: Patients with coronary stenosis had significantly lower CFVR (1.7 ± 0.4) and greater %AT (65 ± 9%) compared with those without stenosis (2.6 ± 0.6 and 50 ± 13%, respectively). Percentage acceleration time by Doppler echocardiography was in good agreement with %AT (r = 0.98) and fractional flow reserve (r = 0.74) invasively measured by dual-sensor guidewire. Cutoff values of CFVR and %AT were determined as 2.0 and 60% in receiver operating characteristic curve analysis. The sensitivity, specificity, and accuracy of CFVR to detect coronary stenosis were 71.1%, 77.3%, and 75.4%, while those of %AT were 83.4%, 71.8%, and 75.4%, respectively. In addition, %AT provided high accuracy to detect coronary stenosis, especially in patients with previous myocardial infarctions, valvular disease, and left ventricular hypertrophy (81.1%, 84.1%, and 73.4%, respectively). CONCLUSIONS: The %AT of systolic coronary flow velocity is a promising marker to diagnose coronary stenosis in patients with microvascular dysfunction.


Asunto(s)
Circulación Coronaria , Estenosis Coronaria/complicaciones , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Enfermedades de las Válvulas Cardíacas/complicaciones , Adenosina Trifosfato , Adulto , Anciano , Área Bajo la Curva , Velocidad del Flujo Sanguíneo , Angiografía Coronaria , Estenosis Coronaria/fisiopatología , Ecocardiografía , Femenino , Humanos , Hiperemia/inducido químicamente , Hiperemia/complicaciones , Hipertrofia Ventricular Izquierda/complicaciones , Masculino , Curva ROC , Volumen Sistólico , Sístole
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...