Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-33799791

RESUMEN

A COVID-19 outbreak occurred among residents of a Roma settlement in Greece (8 April-4 June 2020). The aim of this study was to identify factors associated with an increased risk of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and to evaluate the effectiveness of control measures implemented. Data were analyzed from individuals that were tested for SARS-CoV-2 during contact tracing, population screening or hospital visits. RT-PCR was used for the detection of SARS-CoV-2 in oropharyngeal samples. Risk factors for household secondary attack rates (SAR) and hospitalization with COVID-19 were examined using chi-square tests, Fisher's exact tests and logistic regression analyses. During the outbreak, 142 cases, 20 hospitalizations and 1 death were recorded, with a total of 2273 individuals tested. The risk of hospitalization was associated with age (OR: 1.04, 95% CI: 1.02-1.07) and Cycle threshold (Ct) values (OR for a decrease in Ct values by 1: 1.18, 95% CI: 1.07-1.31). Household SAR was estimated at 38.62% (95% CI: 32.50-45.01%). After the designation of an isolation facility for cases, household SAR declined from 74.42% to 31.03%. Household size was associated with the risk of infection (OR: 2.65, 95% CI: 1.00-7.07). The presence of COVID-19 symptoms among index cases was correlated with higher transmission (OR: 23.68, 95% CI 2.21-253.74) in multivariate analysis, while age was found to be associated with SAR only in univariate analysis. Roma communities can be particularly vulnerable to the spread of SARS-CoV-2. In similar settings, symptomatic cases are more important transmitters of SARS-CoV-2. Within these communities, immediate measures should be implemented to mitigate disease spread.


Asunto(s)
COVID-19 , Romaní , Brotes de Enfermedades , Grecia/epidemiología , Humanos , SARS-CoV-2
2.
Artículo en Inglés | MEDLINE | ID: mdl-30513698

RESUMEN

This study aimed to assess the colonization of hotel water systems in central Greece and Corfu by Legionella, and to investigate the association between physicochemical parameters and Legionella colonization. Standardized hygiene inspection was conducted in 51 hotels, and 556 water samples were analyzed for Legionella spp. Free chlorine concentration, pH, hardness, conductivity, and trace metals were defined in cold water samples. The results of inspections and chemical analyses were associated with the microbiological results using univariate and logistic regression analysis. According to the score of the checklist used for the inspections, 17.6% of the hotels were classified as satisfactory, 15.7% as adequate, and 66.7% as unsatisfactory. Moreover, 74.5% of the hotels were colonized by Legionella spp. and 31.4% required remedial measures according to the European guidelines. Legionella spp. were isolated in 28% of the samples. Unsatisfactory results of inspections were associated with Legionella presence (relative risk (RR) = 7.67, p-value = 0.043). In hot-water systems, <50 °C temperatures increased the risk of Legionella colonization (RR = 5.36, p-value < 0.001). In cold-water systems, free chlorine concentration <0.375 mg/L (odds ratio (OR) = 9.76, p-value = 0.001), pH ≥ 7.45 (OR = 4.05, p-value = 0.007), and hardness ≥321 mgCaCO3/L (OR = 5.63, p-value = 0.003) increased the risk, whereas copper pipes demonstrated a protective role (OR = 0.29, p-value = 0.0024). The majority of the hotels inspected were colonized with Legionella. Supplementary monitoring of the risk factors that were identified should be considered.


Asunto(s)
Legionella/aislamiento & purificación , Enfermedad de los Legionarios/epidemiología , Instalaciones Públicas , Abastecimiento de Agua/normas , Recuento de Colonia Microbiana , Brotes de Enfermedades , Grecia , Humanos , Enfermedad de los Legionarios/microbiología , Enfermedad de los Legionarios/prevención & control , Instalaciones Públicas/normas , Factores de Riesgo , Temperatura , Microbiología del Agua
3.
Case Rep Infect Dis ; 2018: 2570758, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30186646

RESUMEN

Healthcare-associated Legionnaires' disease often leads to fatal respiratory tract infection among hospitalized patients. In this report, three cases of Legionnaires' disease among patients in two different hospitals (Hospital A and Hospital B) were investigated. After conducting an epidemiologic and environmental investigation, the water distribution systems (WDSs) were identified as the possible source of infection, as Legionella pneumophila serogroup 1 (Lp1) was isolated from both clinical and environmental samples. Patients received aerosol therapy with nebulizers during their hospitalization. Based on the results of the investigation, the hospitals' infection control committees reviewed their policies for Legionnaires' disease prevention and implemented control measures focusing on using sterile fluids for aerosol treatments.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...