Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 210
Filtrar
1.
Heart ; 110(19): 1164-1196, 2024 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-39284618
2.
Ann Pediatr Cardiol ; 17(2): 97-100, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39184110

RESUMEN

Introduction: Permanent pacemaker implantation (PPI) in neonates is challenging with respect to indications, device selection, implantation technique, and long-term outcomes. Complex anatomy, the need for long-term pacing with high rates, and a problematic postoperative period are the major problems. Methods: We prospectively followed up 22 newborns who underwent PPI below 28 days of life at our institute. Results: The median age at implantation was 2 days (interquartile range 1-9 days), and 9% were born preterm. The average heart rate before implantation was 46.4 ± 7.2 bpm. Maternal lupus antibodies were positive in 8 (36.4%) neonates, whereas 11 (50.0%) had associated congenital heart disease. Nineteen neonates underwent single chamber (VVI) and three underwent dual chamber (DDD) pacemaker implantation. Over a median follow-up of 46 months (range 2-123 months), the average ventricular pacing percentage was 87.5 ± 24.9%, with a stable pacing threshold. Seven children underwent pulse generator replacement due to battery depletion at a median age of 47 months. Pacing-induced ventricular dysfunction was seen in five children at a median age of 23.6 months, and two underwent upgradation to cardiac resynchronization therapy. Overall mortality was 13.6%, all due to tissue hypoperfusion and lactic acidosis in the postimplantation period. Conclusions: PPI in neonates has a favorable outcome with excellent lead survival. Overall mortality is 13.6%, which is predominantly in the postimplantation period and related to myocardial dysfunction.

4.
Egypt Heart J ; 76(1): 100, 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39120759

RESUMEN

BACKGROUND: Takayasu arteritis (TA) is a chronic inflammatory disease of unknown etiology characterized by a large vessel vasculitis involving the aorta and its branches. Myocardial involvement is extremely unusual in TA and is mostly in the form of myocarditis, ventricular hypertrophy, and ventricular dysfunction secondary to coronary ischemia. Submitral aneurysms have been reported in TA and has been attributed to the chronic inflammatory process in TA. CASE PRESENTATION: We report a novel instance of left ventricular apical aneurysm in a 37-year-old lady with TA and normal epicardial coronaries. She was diagnosed with a left ventricular apical aneurysm, moderate aortic regurgitation, and moderate pericardial effusion. The coronary arteries were normal. The patient had concomitant chronic active Epstein-Barr virus infection complicating patient outcome. CONCLUSIONS: Left ventricular apical aneurysm with normal epicardial coronaries is a rare cause of heart failure in Takayasu arteritis. Concomitant chronic active Epstein-Barr virus infection can potentially accentuate the inflammatory process in Takayasu arteritis and complicate management and patient outcomes.

5.
Heart Rhythm ; 2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-39034018

RESUMEN

An electrocardiogram on the day after implantation of a dual-chamber pacemaker revealed 2 closely coupled pacing spikes at 100-ms intervals, with the latter being on the trailing edge of the paced QRS complex. Differential diagnoses of such closely coupled pacing pulses include atrial lead displacement, lead reversal on the pulse generator, ventricular premature complex in the post-atrial ventricular blanking period, and backup pacing pulse following a loss of capture. Critical analysis of the pacemaker timing intervals led to the mechanism and cause of the problem.

11.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38584423

RESUMEN

Electrical storm (ES) is a state of electrical instability, manifesting as recurrent ventricular arrhythmias (VAs) over a short period of time (three or more episodes of sustained VA within 24 h, separated by at least 5 min, requiring termination by an intervention). The clinical presentation can vary, but ES is usually a cardiac emergency. Electrical storm mainly affects patients with structural or primary electrical heart disease, often with an implantable cardioverter-defibrillator (ICD). Management of ES requires a multi-faceted approach and the involvement of multi-disciplinary teams, but despite advanced treatment and often invasive procedures, it is associated with high morbidity and mortality. With an ageing population, longer survival of heart failure patients, and an increasing number of patients with ICD, the incidence of ES is expected to increase. This European Heart Rhythm Association clinical consensus statement focuses on pathophysiology, clinical presentation, diagnostic evaluation, and acute and long-term management of patients presenting with ES or clustered VA.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Taquicardia Ventricular , Humanos , Factores de Riesgo , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Incidencia , Insuficiencia Cardíaca/complicaciones , Asia/epidemiología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/complicaciones
12.
J Arrhythm ; 40(2): 385-389, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38586858

RESUMEN

Background: Diagnosing myocarditis in children presenting with complete AV block (CAVB) is challenging. Temporary permanent pacing support using standard transvenous active fixation lead can be inserted percutaneously until recovery. However, access to cardiac magnetic resonance (CMR) imaging may be limited due to safety concerns. Cases: We report three cases where CMR was performed using temporary permanent pacemaker in situ. We evaluated the effect of device artefacts on image quality and examined any instances of device malfunction. Conclusion: In children with CAVB and myocarditis, a temporary permanent pacemaker can provide reliable pacing until recovery, and CMR can be safely performed with the implanted pacemaker without compromising image quality.

13.
J Arrhythm ; 40(1): 154-155, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38333382

RESUMEN

This electrophysiological tracing localizes the level of block distal to the recorded Mahaim potential during bump termination mapping of an atriofascicular pathway at the tricuspid annulus.

14.
J Arrhythm ; 40(1): 148-149, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38333393

RESUMEN

This electrophysiology tracing demonstrates a graded postexcitation response of the retrograde limb of an orthodromic reentrant tachycardia circuit with varying His refractory VPB coupling intervals, which reiterates the decrementally conducting retrograde limb of the tachycardia circuit.

15.
Curr Probl Cardiol ; 49(4): 102456, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38346609

RESUMEN

Atrial fibrillation (AF) is a significant risk factor for stroke. Based on the higher stroke associated with AF in the South Asian population, we constructed a one-year stroke prediction model using machine learning (ML) methods in KERALA-AF South Asian cohort. External validation was performed in the prospective APHRS-AF registry. We studied 2101 patients and 83 were to patients with stroke in KERALA-AF registry. The random forest showed the best predictive performance in the internal validation with receiver operator characteristic curve (AUC) and G-mean of 0.821 and 0.427, respectively. In the external validation, the light gradient boosting machine showed the best predictive performance with AUC and G-mean of 0.670 and 0.083, respectively. We report the first demonstration of ML's applicability in an Indian prospective cohort, although the more modest prediction on external validation in a separate multinational Asian registry suggests the need for ethnic-specific ML models.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Estudios Prospectivos , Aprendizaje Automático , Sistema de Registros , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control
16.
Pacing Clin Electrophysiol ; 46(10): 1197-1202, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37728293

RESUMEN

INTRODUCTION: Long QT syndrome is an inherited malignant channelopathy which leads to life-threatening arrhythmia, with multiple genotypes. Jervell and Lange-Nielsen syndrome (JLNS) is an autosomal recessive subtype of this disease, characterized by congenital sensorineural deafness and a high incidence of sudden cardiac death (SCD). METHODOLOGY: We prospectively followed up six children who underwent left cardiac sympathetic denervation (LCSD) for JLNS in view of high-risk features despite being on maximally tolerated doses of oral propranolol. RESULTS: Mean age at diagnosis was 2.75 ± 0.39 years, with a significant delay between onset of symptoms and diagnosis (mean 7.2 ± 3.5 months). All had sensorineural hearing loss, conforming to the JLNS phenotype. Mean QTc interval was 603 ± 93 ms, with T wave alternans (TWA) seen in all cases. All were started on propranolol and subsequently subjected to LCSD, and 3 underwent AAI permanent pacemaker implantation. Over a mean follow-up of 20 months, there was a significant reduction in QTc (603 ± 93 ms to 501 ± 33 ms, p = .04), which was persistent on follow-up (525 ± 41 ms) and only two out of six had persistent T wave alternans on ECG (p < .01). None of these children had presyncope, syncope, seizures, torsades de pointes, cardiac arrest or death on follow up following LCSD. CONCLUSION: Jervell Lange-Nielsen syndrome is a subtype of LQTS with high-risk features. LCSD, an effective therapeutic option for those having symptoms despite being on propranolol, results in significant reduction of QTc interval and amelioration of symptoms.


Asunto(s)
Síndrome de Jervell-Lange Nielsen , Síndrome de QT Prolongado , Niño , Humanos , Lactante , Síndrome de Jervell-Lange Nielsen/diagnóstico , Propranolol , Corazón , Síndrome de QT Prolongado/diagnóstico , Simpatectomía/métodos , Arritmias Cardíacas , Síncope
17.
Indian Heart J ; 75(5): 383-385, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37567444

RESUMEN

This prospective observational study sought to correlate segmental late gadolinium enhancement (LGE) seen in cardiac magnetic resonance imaging with occurrence of ventricular arrhythmias (VAs) in patients with hypertrophic cardiomyopathy. LGE was assessed in a 17-segmental model of heart. Of 57 patients, VAs were present in 26.3% of patients and 10.5% had sustained ventricular tachycardia. LGE was present in 43.9% of patients. Presence of LGE in 4 or more segments was associated with VAs with a sensitivity of 73% and specificity of 76% with area under curve of 0.733 in C-statistics.

18.
Arch Med Sci ; 19(1): 25-34, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36817671

RESUMEN

Introduction: Obesity has emerged as one of the major risk factors of severe morbidity and cause-specific mortality among severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infected individuals. Patients with obesity also have overlapping cardiovascular diseases and diabetes, which make them increasingly vulnerable. This novel ecological study examines the impact of obesity and/or body mass index (BMI) on rates of population-adjusted cases and deaths due to coronavirus disease 2019 (COVID-19). Material and methods: Publicly available datasets were used to obtain relevant data on COVID-19, obesity and ecological variables. Group-wise comparisons and multivariate logistic regression analyses were performed. The receiver operating characteristic curve (ROC) was plotted to compute the area under the curve. Results: We found that male BMI is an independent predictor of cause-specific (COVID-19) mortality, and not of the caseload per million population. Countries with obesity rates of 20-30% had a significantly higher (approximately double) number of deaths per million population to both those in < 20% and > 30% slabs. We postulate that there may be a U-shaped paradoxical relationship between obesity and COVID-19 with the cause-specific mortality burden more pronounced in the countries with 20-30% obesity rates. These findings are novel along with the methodological approach of doing ecological analyses on country-wide data from publicly available sources. Conclusions: We anticipate, in light of our findings, that appropriate targeted public health approaches or campaigns could be developed to minimize the risk and cause-specific morbidity burden due to COVID-19 in countries with nationwide obesity rates of 20-30%.

19.
J Interv Card Electrophysiol ; 66(7): 1589-1600, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36607529

RESUMEN

BACKGROUND: Adoption and outcomes for conduction system pacing (CSP), which includes His bundle pacing (HBP) or left bundle branch area pacing (LBBAP), in real-world settings are incompletely understood. We sought to describe real-world adoption of CSP lead implantation and subsequent outcomes. METHODS: We performed an online cross-sectional survey on the implantation and outcomes associated with CSP, between November 15, 2020, and February 15, 2021. We described survey responses and reported HBP and LBBAP outcomes for bradycardia pacing and cardiac resynchronization CRT indications, separately. RESULTS: The analysis cohort included 140 institutions, located on 5 continents, who contributed data to the worldwide survey on CSP. Of these, 127 institutions (90.7%) reported experience implanting CSP leads. CSP and overall device implantation volumes were reported by 84 institutions. In 2019, the median proportion of device implants with CSP, HBP, and/or LBBAP leads attempted were 4.4% (interquartile range [IQR], 1.9-12.5%; range, 0.4-100%), 3.3% (IQR, 1.3-7.1%; range, 0.2-87.0%), and 2.5% (IQR, 0.5-24.0%; range, 0.1-55.6%), respectively. For bradycardia pacing indications, HBP leads, as compared to LBBAP leads, had higher reported implant threshold (median [IQR]: 1.5 V [1.3-2.0 V] vs 0.8 V [0.6-1.0 V], p = 0.0008) and lower ventricular sensing (median [IQR]: 4.0 mV [3.0-5.0 mV] vs. 10.0 mV [7.0-12.0 mV], p < 0.0001). CONCLUSION: In conclusion, CSP lead implantation has been broadly adopted but has yet to become the default approach at most surveyed institutions. As the indications and data for CSP continue to evolve, strategies to educate and promote CSP lead implantation at institutions without CSP lead implantation experience would be necessary.


Asunto(s)
Bradicardia , Fascículo Atrioventricular , Humanos , Bradicardia/terapia , Estudios Transversales , Sistema de Conducción Cardíaco , Trastorno del Sistema de Conducción Cardíaco , Electrocardiografía , Estimulación Cardíaca Artificial , Resultado del Tratamiento
20.
Indian Pacing Electrophysiol J ; 23(1): 17-20, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36372273

RESUMEN

BACKGROUND: Semi-permanent pacing (SPP) includes the placement of a permanent lead through the internal jugular vein and connection to a pulse generator on the skin outside the venous access site. AIM: To evaluate the clinical profile and outcomes of semi-permanent pacing in a tertiary care institute in Southern India. METHODS: This is a retrospective observational study. All patients admitted and requiring management with semi-permanent pacing from January 2017 to June 2020 were included. RESULTS: From January 2017 to June 2020, 20 patients underwent semi-permanent pacing (SPP) with a median age of 54 (21-74) years. Males comprised a majority of the patients (55%). Hypertension was noted in 50% of patients and 30% were diabetic. The right internal jugular vein was the most common access in 95% of patients. The most common indication for semi-permanent pacing was pocket site infection in 30% of patients. There were no procedural complications. The median duration on SPP was 7 (5-14) days and the median duration of hospital stay was 13 (8-21) days. Permanent pacemaker implantation was done in 55% of patients. Mortality in our study group was 15% with 10% dying due to cardiogenic shock (post resuscitated cardiac arrest) and 5% dying due to non-cardiac cause (Epidural hematoma). CONCLUSION: In our study, semi-permanent pacing was noted to be a safe procedure and was more commonly indicated in emergent conditions with complete heart block secondary to underlying reversible causes and in the management of pocket site infection.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...