Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Biosensors (Basel) ; 13(6)2023 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-37367032

RESUMEN

Highly active antiretroviral therapy (HAART) includes very potent drugs that are often characterized by high toxicity. Tenofovir (TFV) is a widely used drug prescribed mainly for pre-exposure prophylaxis (PreP) and the treatment of human immunodeficiency virus (HIV). The therapeutic range of TFV is narrow, and adverse effects occur with both underdose and overdose. The main factor contributing to therapeutic failure is the improper management of TFV, which may be caused by low compliance or patient variability. An important tool to prevent inappropriate administration is therapeutic drug monitoring (TDM) of compliance-relevant concentrations (ARCs) of TFV. TDM is performed routinely using time-consuming and expensive chromatographic methods coupled with mass spectrometry. Immunoassays, such as enzyme-linked immunosorbent assays (ELISAs) and lateral flow immunoassays (LFIAs), are based on antibody-antigen specific recognition and represent key tools for real-time quantitative and qualitative screening for point-of-care testing (POCT). Since saliva is a non-invasive and non-infectious biological sample, it is well-suited for TDM. However, saliva is expected to have a very low ARC for TFV, so tests with high sensitivity are required. Here, we have developed and validated a highly sensitive ELISA (IC50 1.2 ng/mL, dynamic range 0.4-10 ng/mL) that allows the quantification of TFV in saliva at ARCs and an extremely sensitive LFIA (visual LOD 0.5 ng/mL) that is able to distinguish between optimal and suboptimal ARCs of TFV in untreated saliva.


Asunto(s)
Fármacos Anti-VIH , Infecciones por VIH , Humanos , Tenofovir/uso terapéutico , Fármacos Anti-VIH/uso terapéutico , Infecciones por VIH/tratamiento farmacológico , Saliva , Ensayo de Inmunoadsorción Enzimática , Inmunoensayo
2.
Biosensors (Basel) ; 12(9)2022 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-36140124

RESUMEN

Lumpy skin disease (LSD) is an infectious disease affecting bovine with severe symptomatology. The implementation of effective control strategies to prevent infection outbreak requires rapid diagnostic tools. Two monoclonal antibodies (mAbs), targeting different epitopes of the LSDV structural protein p32, and gold nanoparticles (AuNPs) were used to set up a colorimetric sandwich-type lateral flow immunoassay (LFIA). Combinations including one or two mAbs, used either as the capture or detection reagent, were explored to investigate the hook effect due to antigen saturation by the detector antibody. The mAb-AuNP preparations were optimized by a full-factorial design of experiment to achieve maximum sensitivity. Opposite optimal conditions were selected when one Mab was used for capture and detection instead of two mAbs; thus, two rational routes for developing a highly sensitive LFIA according to Mab availability were outlined. The optimal LFIA for LSDV showed a low limit of detection (103.4 TCID50/mL), high inter- and intra-assay repeatability (CV% < 5.3%), and specificity (no cross-reaction towards 12 other viruses was observed), thus proving to be a good candidate as a useful tool for the point-of-need diagnosis of LSD.


Asunto(s)
Virus de la Dermatosis Nodular Contagiosa , Nanopartículas del Metal , Animales , Bovinos , Anticuerpos Monoclonales , Epítopos , Oro/química , Inmunoensayo , Nanopartículas del Metal/química
3.
Toxins (Basel) ; 12(4)2020 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-32326118

RESUMEN

The diffusion of the legalization of cannabis for recreational, medicinal and nutraceutical uses requires the development of adequate analytical methods to assure the safety and security of such products. In particular, aflatoxins are considered to pose a major risk for the health of cannabis consumers. Among analytical methods that allows for adequate monitoring of food safety, immunoassays play a major role thanks to their cost-effectiveness, high-throughput capacity, simplicity and limited requirement for equipment and skilled operators. Therefore, a rapid and sensitive enzyme immunoassay has been adapted to measure the most hazardous aflatoxin B1 in cannabis products. The assay was acceptably accurate (recovery rate: 78-136%), reproducible (intra- and inter-assay means coefficients of variation 11.8% and 13.8%, respectively), and sensitive (limit of detection and range of quantification: 0.35 ng mL-1 and 0.4-2 ng mL-1, respectively corresponding to 7 ng g-1 and 8-40 ng g-1 ng g-1 in the plant) and provided results which agreed with a HPLC-MS/MS method for the direct analysis of aflatoxin B1 in cannabis inflorescence and leaves. In addition, the carcinogenic aflatoxin B1 was detected in 50% of the cannabis products analyzed (14 samples collected from small retails) at levels exceeding those admitted by the European Union in commodities intended for direct human consumption, thus envisaging the need for effective surveillance of aflatoxin contamination in legal cannabis.


Asunto(s)
Aflatoxina B1/análisis , Cannabis/química , Cromatografía Líquida de Alta Presión , Contaminación de Medicamentos , Técnicas para Inmunoenzimas , Espectrometría de Masas en Tándem
4.
Polymers (Basel) ; 10(2)2018 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-30966228

RESUMEN

Molecularly imprinted thin layers were prepared in silica capillaries by using two different surface polymerization strategies, the first using 4,4'-azobis(4-cyanovaleric acid) as a surface-coupled radical initiator, and the second, S-carboxypropyl-S'-benzyltrithiocarbonate as a reversible addition-fragmentation chain transfer (RAFT) agent in combination with 2,2'-azobisisobutyronitrile as a free radical initiator. The ability to generate imprinted thin layers was tested on two different polymerization systems: (i) a 4-vinylpyridine/ethylene dimethacrylate (4VP-EDMA) in methanol-water solution with 2,4,5-trichlorophenoxyacetic acid (2,4,5-T) as a template; and (ii) methacrylic acid/ethylene dimethacrylate (MAA-EDMA) in a chloroform solution with warfarin as the template molecule. The binding properties of the imprinted capillaries were studied and compared with those of the corresponding non-imprinted polymer coated capillaries by injecting the template molecule and by measuring its migration times relative to a neutral and non-retained marker. The role of running buffer hydrophobicity on recognition was investigated by studying the influence of varying buffer acetonitrile concentration. The 2,4,5-T-imprinted capillary showed molecular recognition based on a reversed phase mechanism, with a decrease of the template recognition in the presence of higher acetonitrile content; whereas warfarin-imprinted capillaries showed a bell-shaped trend upon varying the acetonitrile percentage, illustrating different mechanisms underlying imprinted polymer-ligand recognition. Importantly, the results demonstrated the validity of affinity capillary electrochromatography (CEC) to screen the binding properties of imprinted layers.

5.
J Sep Sci ; 38(20): 3661-8, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26249317

RESUMEN

The aim of this study was the evaluation of the binding performances and selectivity of molecularly imprinted beads prepared toward several penicillins (i) by hierarchical bulk polymerization in the pores of template-grafted silica microbeads (hMIPs) and (ii) by Pickering emulsion polymerization in the presence of template-decorated silica nanobeads (pMIPs). 6-Aminopenicillanic acid was chosen as the common fragmental mimic template. Both approaches produced micron-sized polymeric beads with good recognition properties toward the target ligands whereas the selectivity pattern appeared quite different. The polymer prepared by the Pickering emulsion approach showed binding properties similar to imprinted beads prepared by hierarchical approach. Equilibrium binding constants changed their values from 0.1-0.2 × 10(6) (hMIPs) to 0.2-0.6 × 10(6) M(-1) (pMIPs), while the binding site densities changed from 3.7-4.8 (hMIPs) to 0.3-0.55 µmol/g (pMIPs). Compared to the hierarchical polymerization, Pickering emulsion polymerization represents a more practical approach when a template mimic needs to be used.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...