Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Commun Med (Lond) ; 4(1): 110, 2024 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-38851837

RESUMEN

BACKGROUND: Radiotherapy is a core treatment modality for oropharyngeal cancer (OPC), where the primary gross tumor volume (GTVp) is manually segmented with high interobserver variability. This calls for reliable and trustworthy automated tools in clinician workflow. Therefore, accurate uncertainty quantification and its downstream utilization is critical. METHODS: Here we propose uncertainty-aware deep learning for OPC GTVp segmentation, and illustrate the utility of uncertainty in multiple applications. We examine two Bayesian deep learning (BDL) models and eight uncertainty measures, and utilize a large multi-institute dataset of 292 PET/CT scans to systematically analyze our approach. RESULTS: We show that our uncertainty-based approach accurately predicts the quality of the deep learning segmentation in 86.6% of cases, identifies low performance cases for semi-automated correction, and visualizes regions of the scans where the segmentations likely fail. CONCLUSIONS: Our BDL-based analysis provides a first-step towards more widespread implementation of uncertainty quantification in OPC GTVp segmentation.


Radiotherapy is used as a treatment for people with oropharyngeal cancer. It is important to distinguish the areas where cancer is present so the radiotherapy treatment can be targeted at the cancer. Computational methods based on artificial intelligence can automate this task but need to be able to distinguish areas where it is unclear whether cancer is present. In this study we compare these computational methods that are able to highlight areas where it is unclear whether or not cancer is present. Our approach accurately predicts how well these areas are distinguished by the models. Our results could be applied to improve the computational methods used during radiotherapy treatment. This could enable more targeted treatment to be used in the future, which could result in better outcomes for people with oropharyngeal cancer.

2.
Sci Data ; 11(1): 487, 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38734679

RESUMEN

Radiation therapy (RT) is a crucial treatment for head and neck squamous cell carcinoma (HNSCC); however, it can have adverse effects on patients' long-term function and quality of life. Biomarkers that can predict tumor response to RT are being explored to personalize treatment and improve outcomes. While tissue and blood biomarkers have limitations, imaging biomarkers derived from magnetic resonance imaging (MRI) offer detailed information. The integration of MRI and a linear accelerator in the MR-Linac system allows for MR-guided radiation therapy (MRgRT), offering precise visualization and treatment delivery. This data descriptor offers a valuable repository for weekly intra-treatment diffusion-weighted imaging (DWI) data obtained from head and neck cancer patients. By analyzing the sequential DWI changes and their correlation with treatment response, as well as oncological and survival outcomes, the study provides valuable insights into the clinical implications of DWI in HNSCC.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Neoplasias de Cabeza y Cuello , Humanos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Radioterapia Guiada por Imagen , Carcinoma de Células Escamosas de Cabeza y Cuello/diagnóstico por imagen , Carcinoma de Células Escamosas de Cabeza y Cuello/radioterapia , Aceleradores de Partículas
3.
medRxiv ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38798581

RESUMEN

Background/purpose: The use of artificial intelligence (AI) in radiotherapy (RT) is expanding rapidly. However, there exists a notable lack of clinician trust in AI models, underscoring the need for effective uncertainty quantification (UQ) methods. The purpose of this study was to scope existing literature related to UQ in RT, identify areas of improvement, and determine future directions. Methods: We followed the PRISMA-ScR scoping review reporting guidelines. We utilized the population (human cancer patients), concept (utilization of AI UQ), context (radiotherapy applications) framework to structure our search and screening process. We conducted a systematic search spanning seven databases, supplemented by manual curation, up to January 2024. Our search yielded a total of 8980 articles for initial review. Manuscript screening and data extraction was performed in Covidence. Data extraction categories included general study characteristics, RT characteristics, AI characteristics, and UQ characteristics. Results: We identified 56 articles published from 2015-2024. 10 domains of RT applications were represented; most studies evaluated auto-contouring (50%), followed by image-synthesis (13%), and multiple applications simultaneously (11%). 12 disease sites were represented, with head and neck cancer being the most common disease site independent of application space (32%). Imaging data was used in 91% of studies, while only 13% incorporated RT dose information. Most studies focused on failure detection as the main application of UQ (60%), with Monte Carlo dropout being the most commonly implemented UQ method (32%) followed by ensembling (16%). 55% of studies did not share code or datasets. Conclusion: Our review revealed a lack of diversity in UQ for RT applications beyond auto-contouring. Moreover, there was a clear need to study additional UQ methods, such as conformal prediction. Our results may incentivize the development of guidelines for reporting and implementation of UQ in RT.

5.
medRxiv ; 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38798400

RESUMEN

Purpose: Radiation induced carotid artery disease (RICAD) is a major cause of morbidity and mortality among survivors of oropharyngeal cancer. This study leveraged standard-of-care CT scans to detect volumetric changes in the carotid arteries of patients receiving unilateral radiotherapy (RT) for early tonsillar cancer, and to determine dose-response relationship between RT and carotid volume changes, which could serve as an early imaging marker of RICAD. Methods and Materials: Disease-free cancer survivors (>3 months since therapy and age >18 years) treated with intensity modulated RT for early (T1-2, N0-2b) tonsillar cancer with pre- and post-therapy contrast-enhanced CT scans available were included. Patients treated with definitive surgery, bilateral RT, or additional RT before the post-RT CT scan were excluded. Pre- and post-treatment CTs were registered to the planning CT and dose grid. Isodose lines from treatment plans were projected onto both scans, facilitating the delineation of carotid artery subvolumes in 5 Gy increments (i.e. received 50-55 Gy, 55-60 Gy, etc.). The percent-change in sub-volumes across each dose range was statistically examined using the Wilcoxon rank-sum test. Results: Among 46 patients analyzed, 72% received RT alone, 24% induction chemotherapy followed by RT, and 4% concurrent chemoradiation. The median interval from RT completion to the latest, post-RT CT scan was 43 months (IQR 32-57). A decrease in the volume of the irradiated carotid artery was observed in 78% of patients, while there was a statistically significant difference in mean %-change (±SD) between the total irradiated and spared carotid volumes (7.0±9.0 vs. +3.5±7.2, respectively, p<.0001). However, no significant dose-response trend was observed in the carotid artery volume change withing 5 Gy ranges (mean %-changes (±SD) for the 50-55, 55-60, 60-65, and 65-70+ Gy ranges [irradiated minus spared]: -13.1±14.7, -9.8±14.9, -6.9±16.2, -11.7±11.1, respectively). Notably, two patients (4%) had a cerebrovascular accident (CVA), both occurring in patients with a greater decrease in carotid artery volume in the irradiated vs the spared side. Conclusions: Our data show that standard-of-care oncologic surveillance CT scans can effectively detect reductions in carotid volume following RT for oropharyngeal cancer. Changes were equivalent between studied dose ranges, denoting no further dose-response effect beyond 50 Gy. The clinical utility of carotid volume changes for risk stratification and CVA prediction warrants further evaluation.

6.
Sci Rep ; 14(1): 7912, 2024 04 04.
Artículo en Inglés | MEDLINE | ID: mdl-38575715

RESUMEN

Recent advancements in the field of biomedical engineering have underscored the pivotal role of biodegradable materials in addressing the challenges associated with tissue regeneration therapies. The spectrum of biodegradable materials presently encompasses ceramics, polymers, metals, and composites, each offering distinct advantages for the replacement or repair of compromised human tissues. Despite their utility, these biomaterials are not devoid of limitations, with issues such as suboptimal tissue integration, potential cytotoxicity, and mechanical mismatch (stress shielding) emerging as significant concerns. To mitigate these drawbacks, our research collective has embarked on the development of protein-based composite materials, showcasing enhanced biodegradability and biocompatibility. This study is dedicated to the elaboration and characterization of an innovative suture fabricated from human serum albumin through an extrusion methodology. Employing a suite of analytical techniques-namely tensile testing, scanning electron microscopy (SEM), and thermal gravimetric analysis (TGA)-we endeavored to elucidate the physicochemical attributes of the engineered suture. Additionally, the investigation extends to assessing the influence of integrating biodegradable organic modifiers on the suture's mechanical performance. Preliminary tensile testing has delineated the mechanical profile of the Filament Suture (FS), delineating tensile strengths spanning 1.3 to 9.616 MPa and elongation at break percentages ranging from 11.5 to 146.64%. These findings illuminate the mechanical versatility of the suture, hinting at its applicability across a broad spectrum of medical interventions. Subsequent analyses via SEM and TGA are anticipated to further delineate the suture's morphological features and thermal resilience, thereby enriching our comprehension of its overall performance characteristics. Moreover, the investigation delves into the ramifications of incorporating biodegradable organic constituents on the suture's mechanical integrity. Collectively, the study not only sheds light on the mechanical and thermal dynamics of a novel suture material derived from human serum albumin but also explores the prospective enhancements afforded by the amalgamation of biodegradable organic compounds, thereby broadening the horizon for future biomedical applications.


Asunto(s)
Materiales Biocompatibles , Ingeniería de Tejidos , Humanos , Estudios Prospectivos , Materiales Biocompatibles/química , Suturas , Albúminas , Albúmina Sérica Humana
7.
Radiother Oncol ; 195: 110220, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38467343

RESUMEN

INTRODUCTION: We prospectively evaluated morphologic and functional changes in the carotid arteries of patients treated with unilateral neck radiation therapy (RT) for head and neck cancer. METHODS: Bilateral carotid artery duplex studies were performed at 0, 3, 6, 12, 18 months and 2, 3, 4, and 5 years following RT. Intima media thickness (IMT); global and regional circumferential, as well as radial strain, arterial elasticity, stiffness, and distensibility were calculated. RESULTS: Thirty-eight patients were included. A significant difference in the IMT from baseline between irradiated and unirradiated carotid arteries was detected at 18 months (median, 0.073 mm vs -0.003 mm; P = 0.014), which increased at 3 and 4 years (0.128 mm vs 0.013 mm, P = 0.016, and 0.177 mm vs 0.023 mm, P = 0.0002, respectively). A significant transient change was noted in global circumferential strain between the irradiated and unirradiated arteries at 6 months (median difference, -0.89, P = 0.023), which did not persist. No significant differences were detected in the other measures of elasticity, stiffness, and distensibility. CONCLUSIONS: Functional and morphologic changes of the carotid arteries detected by carotid ultrasound, such as changes in global circumferential strain at 6 months and carotid IMT at 18 months, may be useful for the early detection of radiation-induced carotid artery injury, can guide future research aiming to mitigate carotid artery stenosis, and should be considered for clinical surveillance survivorship recommendations after head and neck RT.


Asunto(s)
Arterias Carótidas , Grosor Intima-Media Carotídeo , Neoplasias de Cabeza y Cuello , Humanos , Neoplasias de Cabeza y Cuello/radioterapia , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Masculino , Femenino , Estudios Prospectivos , Persona de Mediana Edad , Arterias Carótidas/diagnóstico por imagen , Arterias Carótidas/efectos de la radiación , Anciano , Adulto , Estudios Longitudinales
8.
medRxiv ; 2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38370746

RESUMEN

Background: Acute pain is a common and debilitating symptom experienced by oral cavity and oropharyngeal cancer (OC/OPC) patients undergoing radiation therapy (RT). Uncontrolled pain can result in opioid overuse and increased risks of long-term opioid dependence. The specific aim of this exploratory analysis was the prediction of severe acute pain and opioid use in the acute on-treatment setting, to develop risk-stratification models for pragmatic clinical trials. Materials and Methods: A retrospective study was conducted on 900 OC/OPC patients treated with RT during 2017 to 2023. Clinical data including demographics, tumor data, pain scores and medication data were extracted from patient records. On-treatment pain intensity scores were assessed using a numeric rating scale (0-none, 10-worst) and total opioid doses were calculated using morphine equivalent daily dose (MEDD) conversion factors. Analgesics efficacy was assessed based on the combined pain intensity and the total required MEDD. ML models, including Logistic Regression (LR), Support Vector Machine (SVM), Random Forest (RF), and Gradient Boosting Model (GBM) were developed and validated using ten-fold cross-validation. Performance of models were evaluated using discrimination and calibration metrics. Feature importance was investigated using bootstrap and permutation techniques. Results: For predicting acute pain intensity, the GBM demonstrated superior area under the receiver operating curve (AUC) (0.71), recall (0.39), and F1 score (0.48). For predicting the total MEDD, LR outperformed other models in the AUC (0.67). For predicting the analgesics efficacy, SVM achieved the highest specificity (0.97), and best calibration (ECE of 0.06), while RF and GBM achieved the same highest AUC, 0.68. RF model emerged as the best calibrated model with ECE of 0.02 for pain intensity prediction and 0.05 for MEDD prediction. Baseline pain scores and vital signs demonstrated the most contributed features for the different predictive models. Conclusion: These ML models are promising in predicting end-of-treatment acute pain and opioid requirements and analgesics efficacy in OC/OPC patients undergoing RT. Baseline pain score, vital sign changes were identified as crucial predictors. Implementation of these models in clinical practice could facilitate early risk stratification and personalized pain management. Prospective multicentric studies and external validation are essential for further refinement and generalizability.

10.
Med Phys ; 51(1): 278-291, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37475466

RESUMEN

BACKGROUND: In order to accurately accumulate delivered dose for head and neck cancer patients treated with the Adapt to Position workflow on the 1.5T magnetic resonance imaging (MRI)-linear accelerator (MR-linac), the low-resolution T2-weighted MRIs used for daily setup must be segmented to enable reconstruction of the delivered dose at each fraction. PURPOSE: In this pilot study, we evaluate various autosegmentation methods for head and neck organs at risk (OARs) on on-board setup MRIs from the MR-linac for off-line reconstruction of delivered dose. METHODS: Seven OARs (parotid glands, submandibular glands, mandible, spinal cord, and brainstem) were contoured on 43 images by seven observers each. Ground truth contours were generated using a simultaneous truth and performance level estimation (STAPLE) algorithm. Twenty total autosegmentation methods were evaluated in ADMIRE: 1-9) atlas-based autosegmentation using a population atlas library (PAL) of 5/10/15 patients with STAPLE, patch fusion (PF), random forest (RF) for label fusion; 10-19) autosegmentation using images from a patient's 1-4 prior fractions (individualized patient prior [IPP]) using STAPLE/PF/RF; 20) deep learning (DL) (3D ResUNet trained on 43 ground truth structure sets plus 45 contoured by one observer). Execution time was measured for each method. Autosegmented structures were compared to ground truth structures using the Dice similarity coefficient, mean surface distance (MSD), Hausdorff distance (HD), and Jaccard index (JI). For each metric and OAR, performance was compared to the inter-observer variability using Dunn's test with control. Methods were compared pairwise using the Steel-Dwass test for each metric pooled across all OARs. Further dosimetric analysis was performed on three high-performing autosegmentation methods (DL, IPP with RF and 4 fractions [IPP_RF_4], IPP with 1 fraction [IPP_1]), and one low-performing (PAL with STAPLE and 5 atlases [PAL_ST_5]). For five patients, delivered doses from clinical plans were recalculated on setup images with ground truth and autosegmented structure sets. Differences in maximum and mean dose to each structure between the ground truth and autosegmented structures were calculated and correlated with geometric metrics. RESULTS: DL and IPP methods performed best overall, all significantly outperforming inter-observer variability and with no significant difference between methods in pairwise comparison. PAL methods performed worst overall; most were not significantly different from the inter-observer variability or from each other. DL was the fastest method (33 s per case) and PAL methods the slowest (3.7-13.8 min per case). Execution time increased with a number of prior fractions/atlases for IPP and PAL. For DL, IPP_1, and IPP_RF_4, the majority (95%) of dose differences were within ± 250 cGy from ground truth, but outlier differences up to 785 cGy occurred. Dose differences were much higher for PAL_ST_5, with outlier differences up to 1920 cGy. Dose differences showed weak but significant correlations with all geometric metrics (R2 between 0.030 and 0.314). CONCLUSIONS: The autosegmentation methods offering the best combination of performance and execution time are DL and IPP_1. Dose reconstruction on on-board T2-weighted MRIs is feasible with autosegmented structures with minimal dosimetric variation from ground truth, but contours should be visually inspected prior to dose reconstruction in an end-to-end dose accumulation workflow.


Asunto(s)
Neoplasias de Cabeza y Cuello , Planificación de la Radioterapia Asistida por Computador , Humanos , Proyectos Piloto , Flujo de Trabajo , Planificación de la Radioterapia Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Imagen por Resonancia Magnética/métodos , Órganos en Riesgo
11.
medRxiv ; 2023 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-38105979

RESUMEN

Background/objective: Pain is a challenging multifaceted symptom reported by most cancer patients, resulting in a substantial burden on both patients and healthcare systems. This systematic review aims to explore applications of artificial intelligence/machine learning (AI/ML) in predicting pain-related outcomes and supporting decision-making processes in pain management in cancer. Methods: A comprehensive search of Ovid MEDLINE, EMBASE and Web of Science databases was conducted using terms including "Cancer", "Pain", "Pain Management", "Analgesics", "Opioids", "Artificial Intelligence", "Machine Learning", "Deep Learning", and "Neural Networks" published up to September 7, 2023. The screening process was performed using the Covidence screening tool. Only original studies conducted in human cohorts were included. AI/ML models, their validation and performance and adherence to TRIPOD guidelines were summarized from the final included studies. Results: This systematic review included 44 studies from 2006-2023. Most studies were prospective and uni-institutional. There was an increase in the trend of AI/ML studies in cancer pain in the last 4 years. Nineteen studies used AI/ML for classifying cancer patients' pain development after cancer therapy, with median AUC 0.80 (range 0.76-0.94). Eighteen studies focused on cancer pain research with median AUC 0.86 (range 0.50-0.99), and 7 focused on applying AI/ML for cancer pain management decisions with median AUC 0.71 (range 0.47-0.89). Multiple ML models were investigated with. median AUC across all models in all studies (0.77). Random forest models demonstrated the highest performance (median AUC 0.81), lasso models had the highest median sensitivity (1), while Support Vector Machine had the highest median specificity (0.74). Overall adherence of included studies to TRIPOD guidelines was 70.7%. Lack of external validation (14%) and clinical application (23%) of most included studies was detected. Reporting of model calibration was also missing in the majority of studies (5%). Conclusion: Implementation of various novel AI/ML tools promises significant advances in the classification, risk stratification, and management decisions for cancer pain. These advanced tools will integrate big health-related data for personalized pain management in cancer patients. Further research focusing on model calibration and rigorous external clinical validation in real healthcare settings is imperative for ensuring its practical and reliable application in clinical practice.

12.
J Med Imaging (Bellingham) ; 10(6): 065501, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37937259

RESUMEN

Purpose: To improve segmentation accuracy in head and neck cancer (HNC) radiotherapy treatment planning for the 1.5T hybrid magnetic resonance imaging/linear accelerator (MR-Linac), three-dimensional (3D), T2-weighted, fat-suppressed magnetic resonance imaging sequences were developed and optimized. Approach: After initial testing, spectral attenuated inversion recovery (SPAIR) was chosen as the fat suppression technique. Five candidate SPAIR sequences and a nonsuppressed, T2-weighted sequence were acquired for five HNC patients using a 1.5T MR-Linac. MR physicists identified persistent artifacts in two of the SPAIR sequences, so the remaining three SPAIR sequences were further analyzed. The gross primary tumor volume, metastatic lymph nodes, parotid glands, and pterygoid muscles were delineated using five segmentors. A robust image quality analysis platform was developed to objectively score the SPAIR sequences on the basis of qualitative and quantitative metrics. Results: Sequences were analyzed for the signal-to-noise ratio and the contrast-to-noise ratio and compared with fat and muscle, conspicuity, pairwise distance metrics, and segmentor assessments. In this analysis, the nonsuppressed sequence was inferior to each of the SPAIR sequences for the primary tumor, lymph nodes, and parotid glands, but it was superior for the pterygoid muscles. The SPAIR sequence that received the highest combined score among the analysis categories was recommended to Unity MR-Linac users for HNC radiotherapy treatment planning. Conclusions: Our study led to two developments: an optimized, 3D, T2-weighted, fat-suppressed sequence that can be disseminated to Unity MR-Linac users and a robust image quality analysis pathway that can be used to objectively score SPAIR sequences and can be customized and generalized to any image quality optimization protocol. Improved segmentation accuracy with the proposed SPAIR sequence will potentially lead to improved treatment outcomes and reduced toxicity for patients by maximizing the target coverage and minimizing the radiation exposure of organs at risk.

14.
medRxiv ; 2023 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-37645931

RESUMEN

Radiation therapy (RT) is a crucial treatment for head and neck squamous cell carcinoma (HNSCC), however it can have adverse effects on patients' long-term function and quality of life. Biomarkers that can predict tumor response to RT are being explored to personalize treatment and improve outcomes. While tissue and blood biomarkers have limitations, imaging biomarkers derived from magnetic resonance imaging (MRI) offer detailed information. The integration of MRI and a linear accelerator in the MR-Linac system allows for MR-guided radiation therapy (MRgRT), offering precise visualization and treatment delivery. This data descriptor offers a valuable repository for weekly intra-treatment diffusion-weighted imaging (DWI) data obtained from head and neck cancer patients. By analyzing the sequential DWI changes and their correlation with treatment response, as well as oncological and survival outcomes, the study provides valuable insights into the clinical implications of DWI in HNSCC. [Table: see text].

15.
Front Oncol ; 13: 1210087, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37614495

RESUMEN

Purpose: Identify Oropharyngeal cancer (OPC) patients at high-risk of developing long-term severe radiation-associated symptoms using dose volume histograms for organs-at-risk, via unsupervised clustering. Material and methods: All patients were treated using radiation therapy for OPC. Dose-volume histograms of organs-at-risk were extracted from patients' treatment plans. Symptom ratings were collected via the MD Anderson Symptom Inventory (MDASI) given weekly during, and 6 months post-treatment. Drymouth, trouble swallowing, mucus, and vocal dysfunction were selected for analysis in this study. Patient stratifications were obtained by applying Bayesian Mixture Models with three components to patient's dose histograms for relevant organs. The clusters with the highest total mean doses were translated into dose thresholds using rule mining. Patient stratifications were compared against Tumor staging information using multivariate likelihood ratio tests. Model performance for prediction of moderate/severe symptoms at 6 months was compared against normal tissue complication probability (NTCP) models using cross-validation. Results: A total of 349 patients were included for long-term symptom prediction. High-risk clusters were significantly correlated with outcomes for severe late drymouth (p <.0001, OR = 2.94), swallow (p = .002, OR = 5.13), mucus (p = .001, OR = 3.18), and voice (p = .009, OR = 8.99). Simplified clusters were also correlated with late severe symptoms for drymouth (p <.001, OR = 2.77), swallow (p = .01, OR = 3.63), mucus (p = .01, OR = 2.37), and voice (p <.001, OR = 19.75). Proposed cluster stratifications show better performance than NTCP models for severe drymouth (AUC.598 vs.559, MCC.143 vs.062), swallow (AUC.631 vs.561, MCC.20 vs -.030), mucus (AUC.596 vs.492, MCC.164 vs -.041), and voice (AUC.681 vs.555, MCC.181 vs -.019). Simplified dose thresholds also show better performance than baseline models for predicting late severe ratings for all symptoms. Conclusion: Our results show that leveraging the 3-D dose histograms from radiation therapy plan improves stratification of patients according to their risk of experiencing long-term severe radiation associated symptoms, beyond existing NTPC models. Our rule-based method can approximate our stratifications with minimal loss of accuracy and can proactively identify risk factors for radiation-associated toxicity.

16.
medRxiv ; 2023 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-37205359

RESUMEN

Objectives: We aim to characterize the serial quantitative apparent diffusion coefficient (ADC) changes of the target disease volume using diffusion-weighted imaging (DWI) acquired weekly during radiation therapy (RT) on a 1.5T MR-Linac and correlate these changes with tumor response and oncologic outcomes for head and neck squamous cell carcinoma (HNSCC) patients as part of a programmatic R-IDEAL biomarker characterization effort. Methods: Thirty patients with pathologically confirmed HNSCC who received curative-intent RT at the University of Texas MD Anderson Cancer Center, were included in this prospective study. Baseline and weekly Magnetic resonance imaging (MRI) (weeks 1-6) were obtained, and various ADC parameters (mean, 5 th , 10 th , 20 th , 30 th , 40 th , 50 th , 60 th , 70 th , 80 th , 90 th and 95 th percentile) were extracted from the target regions of interest (ROIs). Baseline and weekly ADC parameters were correlated with response during RT, loco-regional control, and the development of recurrence using the Mann-Whitney U test. The Wilcoxon signed-rank test was used to compare the weekly ADC versus baseline values. Weekly volumetric changes (Δvolume) for each ROI were correlated with ΔADC using Spearman's Rho test. Recursive partitioning analysis (RPA) was performed to identify the optimal ΔADC threshold associated with different oncologic outcomes. Results: There was an overall significant rise in all ADC parameters during different time points of RT compared to baseline values for both gross primary disease volume (GTV-P) and gross nodal disease volumes (GTV-N). The increased ADC values for GTV-P were statistically significant only for primary tumors achieving complete remission (CR) during RT. RPA identified GTV-P ΔADC 5 th percentile >13% at the 3 rd week of RT as the most significant parameter associated with CR for primary tumor during RT (p <0.001). Baseline ADC parameters for GTV-P and GTV-N didn't significantly correlate with response to RT or other oncologic outcomes. There was a significant decrease in residual volume of both GTV-P & GTV-N throughout the course of RT. Additionally, a significant negative correlation between mean ΔADC and Δvolume for GTV-P at the 3 rd and 4 th week of RT was detected (r = -0.39, p = 0.044 & r = -0.45, p = 0.019, respectively). Conclusion: Assessment of ADC kinetics at regular intervals throughout RT seems to be correlated with RT response. Further studies with larger cohorts and multi-institutional data are needed for validation of ΔADC as a model for prediction of response to RT.

17.
medRxiv ; 2023 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-36865296

RESUMEN

Background: Oropharyngeal cancer (OPC) is a widespread disease, with radiotherapy being a core treatment modality. Manual segmentation of the primary gross tumor volume (GTVp) is currently employed for OPC radiotherapy planning, but is subject to significant interobserver variability. Deep learning (DL) approaches have shown promise in automating GTVp segmentation, but comparative (auto)confidence metrics of these models predictions has not been well-explored. Quantifying instance-specific DL model uncertainty is crucial to improving clinician trust and facilitating broad clinical implementation. Therefore, in this study, probabilistic DL models for GTVp auto-segmentation were developed using large-scale PET/CT datasets, and various uncertainty auto-estimation methods were systematically investigated and benchmarked. Methods: We utilized the publicly available 2021 HECKTOR Challenge training dataset with 224 co-registered PET/CT scans of OPC patients with corresponding GTVp segmentations as a development set. A separate set of 67 co-registered PET/CT scans of OPC patients with corresponding GTVp segmentations was used for external validation. Two approximate Bayesian deep learning methods, the MC Dropout Ensemble and Deep Ensemble, both with five submodels, were evaluated for GTVp segmentation and uncertainty performance. The segmentation performance was evaluated using the volumetric Dice similarity coefficient (DSC), mean surface distance (MSD), and Hausdorff distance at 95% (95HD). The uncertainty was evaluated using four measures from literature: coefficient of variation (CV), structure expected entropy, structure predictive entropy, and structure mutual information, and additionally with our novel Dice-risk measure. The utility of uncertainty information was evaluated with the accuracy of uncertainty-based segmentation performance prediction using the Accuracy vs Uncertainty (AvU) metric, and by examining the linear correlation between uncertainty estimates and DSC. In addition, batch-based and instance-based referral processes were examined, where the patients with high uncertainty were rejected from the set. In the batch referral process, the area under the referral curve with DSC (R-DSC AUC) was used for evaluation, whereas in the instance referral process, the DSC at various uncertainty thresholds were examined. Results: Both models behaved similarly in terms of the segmentation performance and uncertainty estimation. Specifically, the MC Dropout Ensemble had 0.776 DSC, 1.703 mm MSD, and 5.385 mm 95HD. The Deep Ensemble had 0.767 DSC, 1.717 mm MSD, and 5.477 mm 95HD. The uncertainty measure with the highest DSC correlation was structure predictive entropy with correlation coefficients of 0.699 and 0.692 for the MC Dropout Ensemble and the Deep Ensemble, respectively. The highest AvU value was 0.866 for both models. The best performing uncertainty measure for both models was the CV which had R-DSC AUC of 0.783 and 0.782 for the MC Dropout Ensemble and Deep Ensemble, respectively. With referring patients based on uncertainty thresholds from 0.85 validation DSC for all uncertainty measures, on average the DSC improved from the full dataset by 4.7% and 5.0% while referring 21.8% and 22% patients for MC Dropout Ensemble and Deep Ensemble, respectively. Conclusion: We found that many of the investigated methods provide overall similar but distinct utility in terms of predicting segmentation quality and referral performance. These findings are a critical first-step towards more widespread implementation of uncertainty quantification in OPC GTVp segmentation.

18.
Front Oncol ; 13: 1120392, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36925936

RESUMEN

Background: Demand for head and neck cancer (HNC) radiotherapy data in algorithmic development has prompted increased image dataset sharing. Medical images must comply with data protection requirements so that re-use is enabled without disclosing patient identifiers. Defacing, i.e., the removal of facial features from images, is often considered a reasonable compromise between data protection and re-usability for neuroimaging data. While defacing tools have been developed by the neuroimaging community, their acceptability for radiotherapy applications have not been explored. Therefore, this study systematically investigated the impact of available defacing algorithms on HNC organs at risk (OARs). Methods: A publicly available dataset of magnetic resonance imaging scans for 55 HNC patients with eight segmented OARs (bilateral submandibular glands, parotid glands, level II neck lymph nodes, level III neck lymph nodes) was utilized. Eight publicly available defacing algorithms were investigated: afni_refacer, DeepDefacer, defacer, fsl_deface, mask_face, mri_deface, pydeface, and quickshear. Using a subset of scans where defacing succeeded (N=29), a 5-fold cross-validation 3D U-net based OAR auto-segmentation model was utilized to perform two main experiments: 1.) comparing original and defaced data for training when evaluated on original data; 2.) using original data for training and comparing the model evaluation on original and defaced data. Models were primarily assessed using the Dice similarity coefficient (DSC). Results: Most defacing methods were unable to produce any usable images for evaluation, while mask_face, fsl_deface, and pydeface were unable to remove the face for 29%, 18%, and 24% of subjects, respectively. When using the original data for evaluation, the composite OAR DSC was statistically higher (p ≤ 0.05) for the model trained with the original data with a DSC of 0.760 compared to the mask_face, fsl_deface, and pydeface models with DSCs of 0.742, 0.736, and 0.449, respectively. Moreover, the model trained with original data had decreased performance (p ≤ 0.05) when evaluated on the defaced data with DSCs of 0.673, 0.693, and 0.406 for mask_face, fsl_deface, and pydeface, respectively. Conclusion: Defacing algorithms may have a significant impact on HNC OAR auto-segmentation model training and testing. This work highlights the need for further development of HNC-specific image anonymization methods.

19.
Med Phys ; 50(4): 2089-2099, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36519973

RESUMEN

BACKGROUND/PURPOSE: Adequate image registration of anatomical and functional magnetic resonance imaging (MRI) scans is necessary for MR-guided head and neck cancer (HNC) adaptive radiotherapy planning. Despite the quantitative capabilities of diffusion-weighted imaging (DWI) MRI for treatment plan adaptation, geometric distortion remains a considerable limitation. Therefore, we systematically investigated various deformable image registration (DIR) methods to co-register DWI and T2-weighted (T2W) images. MATERIALS/METHODS: We compared three commercial (ADMIRE, Velocity, Raystation) and three open-source (Elastix with default settings [Elastix Default], Elastix with parameter set 23 [Elastix 23], Demons) post-acquisition DIR methods applied to T2W and DWI MRI images acquired during the same imaging session in twenty immobilized HNC patients. In addition, we used the non-registered images (None) as a control comparator. Ground-truth segmentations of radiotherapy structures (tumour and organs at risk) were generated by a physician expert on both image sequences. For each registration approach, structures were propagated from T2W to DWI images. These propagated structures were then compared with ground-truth DWI structures using the Dice similarity coefficient and mean surface distance. RESULTS: 19 left submandibular glands, 18 right submandibular glands, 20 left parotid glands, 20 right parotid glands, 20 spinal cords, and 12 tumours were delineated. Most DIR methods took <30 s to execute per case, with the exception of Elastix 23 which took ∼458 s to execute per case. ADMIRE and Elastix 23 demonstrated improved performance over None for all metrics and structures (Bonferroni-corrected p < 0.05), while the other methods did not. Moreover, ADMIRE and Elastix 23 significantly improved performance in individual and pooled analysis compared to all other methods. CONCLUSIONS: The ADMIRE DIR method offers improved geometric performance with reasonable execution time so should be favoured for registering T2W and DWI images acquired during the same scan session in HNC patients. These results are important to ensure the appropriate selection of registration strategies for MR-guided radiotherapy.


Asunto(s)
Neoplasias de Cabeza y Cuello , Planificación de la Radioterapia Asistida por Computador , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Imagen por Resonancia Magnética/métodos , Imagen de Difusión por Resonancia Magnética , Dosificación Radioterapéutica , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos
20.
Oral Oncol Rep ; 72023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38638130

RESUMEN

Objectives: Pain during Radiation Therapy (RT) for oral cavity/oropharyngeal cancer (OC/OPC) is a clinical challenge due to its multifactorial etiology and variable management. The objective of this study was to define complex pain profiles through temporal characterization of pain descriptors, physiologic state, and RT-induced toxicities for pain trajectories understanding. Materials and methods: Using an electronic health record registry, 351 OC/OPC patients treated with RT from 2013 to 2021 were included. Weekly numeric scale pain scores, pain descriptors, vital signs, physician-reported toxicities, and analgesics were analyzed using linear mixed effect models and Spearman's correlation. Area under the pain curve (AUCpain) was calculated to measure pain burden over time. Results: Median pain scores increased from 0 during the weekly visit (WSV)-1 to 5 during WSV-7. By WSV-7, 60% and 74% of patients reported mouth and throat pain, respectively, with a median pain score of 5. Soreness and burning pain peaked during WSV-6/7 (51%). Median AUCpain was 16% (IQR (9.3-23)), and AUCpain significantly varied based on gender, tumor site, surgery, drug use history, and pre-RT pain. A temporal increase in mucositis and dermatitis, declining mean bodyweight (-7.1%; P < 0.001) and mean arterial pressure (MAP) 6.8 mmHg; P < 0.001 were detected. Pulse rate was positively associated while weight and MAP were negatively associated with pain over time (P < 0.001). Conclusion: This study provides insight on in-depth characterization and associations between dynamic pain, physiologic, and toxicity kinetics. Our findings support further needs of optimized pain control through temporal data-driven clinical decision support systems for acute pain management.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA