Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Bioanalysis ; 16(7): 149-163, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38385904

RESUMEN

Aims: AZD7442 is a combination SARS-CoV-2 therapy comprising two co-dosed monoclonal antibodies. Materials & methods: The authors validated a hybrid ligand-binding assay-LC-MS/MS method for pharmacokinetic assessment of AZD7442 in human serum with nominal concentration range of each analyte of 0.300-30.0 µg/ml. Results: Validation results met current regulatory acceptance criteria. The validated method supported three clinical trials that spanned more than 17 months and ≥720 analytical runs (∼30,000 samples and ∼3000 incurred sample reanalyses per analyte). The data generated supported multiple health authority interactions, across the globe. AZD7442 (EVUSHELD) was approved in 12 countries for pre-exposure prophylaxis of COVID-19. Conclusion: The results reported here demonstrate the robust, high-throughput capability of the hybrid ligand-binding assay-LC-MS/MS approach being employed to support-next generation versions of EVUSHELD, AZD3152.


The measurement of antibodies in human body fluids (e.g., blood, serum) has historically been tied to laboratory tests that may face operational limitations, including susceptibility to interference from other blood components and a reliance on unique reagents that can take months to produce. As such, there is a pursuit of alternative analytical methods to more accurately detect and measure antibody drugs from complex matrices. In the method, the authors describe different techniques that once combined were used to capture, separate, filter, fragment and then detect and measure the co-dosed antibody drugs. This method has been validated in accordance with current health authority guidelines and has been used to support three clinical trials that spanned more than 17 months; that is, the validated method was used to analyze nearly 30,000 serum samples from more than 2000 patients. Collectively, the results reported here demonstrate the robustness and high-throughput capability of this analytical approach.


Asunto(s)
Anticuerpos Neutralizantes , COVID-19 , Cromatografía Líquida con Espectrometría de Masas , Humanos , Cromatografía Liquida/métodos , Ligandos , Espectrometría de Masas en Tándem/métodos , SARS-CoV-2 , Anticuerpos Monoclonales/uso terapéutico , Combinación de Medicamentos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA