Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 106
Filtrar
2.
JTCVS Tech ; 22: 88-89, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38152195
4.
Catheter Cardiovasc Interv ; 98(2): 382-390, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-33522672

RESUMEN

OBJECTIVE: This study aimed to examine the cumulative experience of peri-device leak (PDL) closure following left atrial appendage (LAA) closure. BACKGROUND: The management of PDL following LAA closure remains controversial. While PDL closure has been proposed, procedural features and clinical outcomes have not been well established. METHODS: A systematic review of all published cases of PDL closure with available anatomical, procedural, and clinical outcomes was performed. RESULTS: We identified 18 indexed publications and 110 cases between April 2013 and March 2020. 71 patients (mean age 72 ± 8 yrs), met study criteria and were included. PDL closure was most common in males, bilobar LAA morphology, and after Watchman procedures. The mean PDL size was 7.6 ± 5.8 mm (range 2-26 mm). Leaks were classified according to size: small (<5 mm; 45%), moderate (≥5-9 mm; 25%), and large (≥10 mm; 30%). Endovascular coils and endovascular plugs were used to close both small and moderate sized leaks, and second LAA closure devices were exclusively used for large PDLs. Successful PDL closure occurred in 90%, and was similar between PDL sizes and types of occluder used. Procedural complication rates were uncommon (2.8%). No strokes were reported following PDL closure at 6 months. CONCLUSIONS: In patients with PDL for whom discontinuation of OAC may be considered unsafe, percutaneous closure using a tailored approach with either endovascular coils, plugs, or second occluder represents a safe, and feasible alternative associated with favorable clinical outcomes.


Asunto(s)
Apéndice Atrial , Cateterismo Cardíaco , Anciano , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/terapia , Cateterismo Cardíaco/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
6.
J Thorac Cardiovasc Surg ; 161(5): 1724-1730, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-31924356

RESUMEN

OBJECTIVE: Redo sternotomy in patients with arterial cardiac structures adherent to the sternum carries a risk of catastrophic bleeding. In some of those cases, particularly if they have undergone multiple previous operations, deep hypothermic circulatory arrest alone may not provide sufficient time for a controlled dissection. METHODS: We present a series of 6 cases at risk for exsanguination during sternal re-entry successfully reoperated using percutaneous cardioplegic cardiac arrest induced before completed sternal re-entry to avoid or minimize the hypothermic circulatory arrest time. RESULTS: All patients survived their complex operations. CONCLUSIONS: Percutaneous cardioplegic arrest allows safer repeat sternotomy in patients with arterial cardiac structures adherent to the sternum.


Asunto(s)
Aneurisma de la Aorta/cirugía , Paro Cardíaco Inducido/métodos , Reoperación/métodos , Esternotomía , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Esternotomía/efectos adversos , Esternotomía/métodos
7.
Artículo en Inglés | MEDLINE | ID: mdl-33188424

RESUMEN

OBJECTIVES: Repair outcomes of tricuspid regurgitation (TR) associated with ischaemic mitral regurgitation (IMR) are inferior to functional TR in terms of TR recurrence and right ventricular (RV) reverse remodelling. Our objective is to analyse right versus left heart reverse remodelling after surgery for IMR-associated TR. METHODS: From 2001 to 2011, 568 patients with severe IMR underwent mitral valve surgery (repair 87%, replacement 13%), and 131 had concomitant tricuspid valve repair. Median follow-up was 3.0 years; 25% of living patients were followed up for 6.3 years. Longitudinal analysis of 1527 follow-up echocardiograms was performed to assess ventricular reverse remodelling and function. RESULTS: Unlike the left heart, the right heart failed to reverse remodel (failed to recover ventricular function or halt dilatation). During follow-up after surgery, the right ventricle continued to dilate while the left ventricle regressed in size. RV ejection fraction decreased (46% at 1 month and 44% at 5 years), while left ventricular ejection fraction increased (33% and 37%, respectively). RV strain showed early (-11% at 1 month) and late (-12% at 5 years) dysfunction. Patients who underwent tricuspid valve repair had worse RV function. Mitral regurgitation remained stable after surgical intervention, and TR gradually recurred (37% moderate, 20% severe at 7 years). CONCLUSIONS: Surgical treatment of IMR and TR along with revascularization failed to induce reverse remodelling of the right heart. These findings warrant further investigations to identify optimal timing and approach of intervention for IMR-associated TR with respect to RV remodelling.

8.
J Card Surg ; 35(12): 3655-3657, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33040389

RESUMEN

High volume extracorporeal membrane oxygenation (ECMO) centers have developed mobile ECMO programs in recent years to facilitate the implementation of ECMO support at hospitals with lower capabilities, and transfer these patients for further care. We report a case of mobile ECMO on a patient with coronavirus disease 2019-related acute respiratory distress syndrome, and discuss the potential application in the current severe acute respiratory syndrome coronavirus 2 pandemic.


Asunto(s)
COVID-19/complicaciones , Oxigenación por Membrana Extracorpórea/métodos , Pandemias , Insuficiencia Respiratoria/terapia , SARS-CoV-2 , COVID-19/epidemiología , Humanos , Persona de Mediana Edad , Insuficiencia Respiratoria/etiología
9.
Eur Heart J Case Rep ; 4(3): 1-5, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32617475

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation operators have adapted to a less invasive technique by foregoing the use of general anaesthesia and transoesophageal echocardiography. This is known as a 'minimalist approach'. This approach has yet to be explored in transcatheter mitral valve replacement (TMVR). Two patients with high perioperative risk underwent TMVR using only monitored conscious sedation (CS) and intracardiac echocardiography (ICE). CASE SUMMARY: The patients were symptomatic and required treatment of severe mitral regurgitation and severe mitral stenosis in a mitral valve ring and prosthetic mitral valve, respectively. With the use of an antegrade transseptal approach, the procedure was conducted under CS using ICE only. After placement of the prosthetic mitral valve, the valve was assessed by advancing the ICE catheter through the interatrial septal defect and no significant paravalvular leak occurred. In one case, ad hoc treatment of right to left shunting was successfully pursued. Valve function was excellent immediately and at 24 h after implantation and resulted in significant haemodynamic improvement. CONCLUSION: With more TMVR cases being conducted, the 'minimalist approach' with CS and ICE may be considered in selected cases.

10.
J Surg Res ; 254: 1-6, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32388058

RESUMEN

BACKGROUND: Little is known about graft patency after coronary artery bypass grafting (CABG) performed in patients on dialysis. Our aim was to assess patency of internal thoracic artery (ITA) grafts and saphenous vein grafts (SVGs) in these patients. METHODS: From 1/1997 to 1/2018, 500 patients on dialysis underwent primary CABG with or without concomitant procedures at Cleveland Clinic, 40 of whom had 48 postoperative angiograms for recurrent ischemic symptoms. Complete follow-up was obtained on all but 1 patient lost to follow-up 1 y after CABG. Thirty-six ITA grafts and 65 SVGs were evaluable for stenosis and occlusion. RESULTS: Two of 40 patients (5%) had emergency CABG; 3 (7.5%) with calcified aortas had a change in operative strategy to avoid ascending aortic manipulation, 2 (5%) had poor conduit quality, and 12 (30%) had severe diffuse atherosclerotic disease with calcification of the coronary targets causing technical difficulties. Thirty-three patients (82%) were bypassed with an in situ ITA and 3 (7.5%) had a free ITA graft. Three of 36 ITA grafts were occluded at 0.78, 1.8, and 9.4 y (too few to model). SVG patency was 52% and 37% at 1 and 2 y, respectively. CONCLUSIONS: Among patients on dialysis who underwent CABG, coronary angiography for ischemic symptoms in a select subset revealed that SVG patency was lower than expected from published reports in the general CABG population and may contribute to the poor prognosis of this cohort. Further work is needed to guide graft selection and improve graft patency in dialysis patients.


Asunto(s)
Puente de Arteria Coronaria , Enfermedad Coronaria/cirugía , Supervivencia de Injerto , Fallo Renal Crónico/complicaciones , Diálisis Renal , Grado de Desobstrucción Vascular , Anciano , Enfermedad Coronaria/complicaciones , Enfermedad Coronaria/mortalidad , Femenino , Humanos , Fallo Renal Crónico/terapia , Masculino , Arterias Mamarias/trasplante , Persona de Mediana Edad , Vena Safena/trasplante , Resultado del Tratamiento
12.
J Am Coll Cardiol ; 75(3): 258-268, 2020 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-31976863

RESUMEN

BACKGROUND: The importance of a coronary artery, based on the myocardial mass it perfuses, is well documented, but little is known about the importance of a vessel that has been bypassed and its effect on survival in the context of bilateral internal thoracic artery (BITA) grafting. OBJECTIVES: This study determined the effect of a dominant left anterior descending (LAD) artery and important non-LAD targets on outcomes after BITA grafting. METHODS: From January 1972 to January 2011, of 6,127 patients who underwent BITA grafting, 2,551 received 1 ITA grafted to the LAD and had an evaluable coronary angiogram. A dominant LAD was defined as one that was wrapped around the left ventricular apex. Non-LAD targets were graded based on their terminal reach toward the apex: important: >75% (n = 1,698); and less important: ≤75% (n = 853). Mean follow-up was 14 ± 8.7 years. Multivariable analysis was performed to identify risk factors for time-related mortality. RESULTS: A dominant LAD was present more frequently in patients with less important additional targets (51% vs. 35%; p < 0.0001). A total of 179 patients (7.0%) received a second ITA to multiple targets, 77 (43%) of which were to multiple important target vessels. Unadjusted late survival was similar regardless of degree of importance of the second ITA target-77% at 15 years (p = 0.70) for the important and less important targets, respectively. In the multivariable model, grafting the second ITA to multiple important targets was associated with better long-term survival (p = 0.005). In patients with a nondominant LAD, a second ITA grafted to a less important artery was associated with higher risk of operative mortality (2.4% vs. 0.51%; p = 0.007). A saphenous vein graft to an important or less important target did not influence long-term survival. CONCLUSIONS: In BITA grafting, bypassing multiple important targets to maximize myocardium supplied by ITAs improved long-term survival. In patients with a nondominant LAD, selecting an important target for the second ITA lowered operative mortality.


Asunto(s)
Puente de Arteria Coronaria/mortalidad , Puente de Arteria Coronaria/métodos , Vasos Coronarios/cirugía , Arterias Mamarias/cirugía , Vasos Coronarios/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Mortalidad Hospitalaria/tendencias , Humanos , Masculino , Arterias Mamarias/diagnóstico por imagen , Persona de Mediana Edad , Estudios Prospectivos , Tasa de Supervivencia/tendencias
13.
Catheter Cardiovasc Interv ; 96(2): 442-447, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31713996

RESUMEN

INTRODUCTION: Percutaneous femoral access is the preferred access route for transcatheter aortic valve replacement (TAVR). The majority of experienced TAVR centers use two 6F Perclose ProGlide™ devices to close the primary vascular access site, deployed prior to upsizing sheath size with closure completed at the end of the case (the "preclose" approach). A strategy of utilizing a single Perclose device to preclose may have advantages including fewer complications, complexity, and cost, but the safety of this is unknown. This study examines in the safety and efficacy of using a single Perclose versus double Perclose for perclosure of large bore access during TAVR. METHODS: Patients undergoing Transfemoral (TF) TAVR from January 2014 to December 2017 within the Cleveland Clinic Aortic Valve Center were identified. A retrospective review of medical charts was conducted. Vascular complications were defined according to the VARC-2 criteria. RESULTS: A total of 740 patients were included; 487 (65.8%) received a single Perclose device while 253 (34.2%) received double Perclose devices. Baseline characteristics were similar with no differences between the single versus double Perclose groups, respectively. The access sheath size was similar in both groups with (14, 16, and 18 F) being the most common sizes utilized. Of the total 487 patients with single Perclose, 75.6% needed additional closure device (AngioSeal). With double Perclose strategy, additional closure device (AngioSeal) was used in 40.3% patients with 470 (63.5%) patients being successfully perclosed. Vascular complication rates including hematoma, stenosis requiring stenting, pseudoaneurysm, and other major vascular complications were similar between both groups. CONCLUSION: Single 6F ProGlide use for preclosure is a safe strategy for TF TAVR using the S3 valve. Additional closure device was not needed in almost one-quarter of the patients. When necessary, residual bleeding can be controlled with the AngioSeal Device at the end of the procedure. This single device preclose strategy can help to reduce the cost of TAVR procedure without increasing risk.


Asunto(s)
Cateterismo Periférico , Arteria Femoral , Hemorragia/prevención & control , Técnicas Hemostáticas/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos de Cierre Vascular , Anciano , Anciano de 80 o más Años , Cateterismo Periférico/efectos adversos , Diseño de Equipo , Femenino , Hemorragia/etiología , Técnicas Hemostáticas/efectos adversos , Humanos , Masculino , Ohio , Punciones , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
14.
JACC Case Rep ; 2(3): 468-472, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34317266

RESUMEN

A variety of fenestrated vascular plugs have been used to seal paravalvular leaks with meaningful success; however, incomplete closure and refractory hemolysis remains a common problem. We describe the feasibility and rationale of their first experience using a nonfenestrated Cardioform Septal Occluder (Gore Medical, Flagstaff, Arizona) to treat a giant mitral paravalvular leak. (Level of Difficulty: Advanced.).

15.
Prog Cardiovasc Dis ; 62(6): 493-495, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31707062

RESUMEN

Patients with isolated functional or recurrent tricuspid regurgitation are often considered high risk and denied surgery. There has been growing experience for transcatheter tricuspid valve implantation through valve-in-valve or valve-in-ring, and recently, but to a lesser extent, in native annulus. The NaviGate is a novel self-expanding valved-stent designed with unique features to treat tricuspid regurgitation, particularly, in the settings of severely dilated tricuspid annulus. Herein, we present the innovation facets and clinical application of the NaviGate system.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Cateterismo Cardíaco/métodos , Diseño de Equipo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Selección de Paciente , Stents Metálicos Autoexpandibles , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/patología , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/cirugía
16.
JACC Cardiovasc Interv ; 12(21): 2210-2220, 2019 11 11.
Artículo en Inglés | MEDLINE | ID: mdl-31699379

RESUMEN

OBJECTIVES: The aim of this study was to compare the rate and trend of vascular complications when placing a second arterial sheath in the contralateral femoral artery during transcatheter aortic valve replacement (TAVR) unilaterally versus bilaterally. BACKGROUND: Vascular complications occur in approximately 5% to 8% of TAVR procedures. Many operators place a second arterial sheath in the contralateral femoral artery to perform aortic root angiography. The authors surmised that placing the second sheath ipsilateral and distal to the delivery sheath would be an easier option with similar safety. METHODS: The Cleveland Clinic Aortic Valve Center TAVR database was accessed, and data for patients undergoing transfemoral TAVR (TF-TAVR) from January 2014 to December 2017 were analyzed retrospectively. The primary outcome was the rate of peripheral vascular complications. RESULTS: A total of 1,208 patients who underwent TF-TAVR were included in this study. One thousand seven patients (83.36%) underwent bilateral femoral access, and 201 patients (16.64%) underwent TF-TAVR using a unilateral femoral approach. Over the study duration, use of the unilateral access approach trended upward significantly, reaching 43.7% of total cases in 2017. A gradual decline in access site-related vascular complications was observed, from 13.7% in 2014 to 7.4% in 2017. After propensity-score matching, peripheral vascular complications were similar between bilateral access and unilateral access (10.8% vs. 8.6%) (p = 0.543). CONCLUSIONS: There was a significant decline in vascular complications from 2014 to 2017. Unilateral-access TF-TAVR provided similar safety compared with bilateral-access TF-TAVR and is a more accessible approach for managing access site-related complications and possibly achieving better patient satisfaction.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Cateterismo Periférico , Arteria Femoral , Reemplazo de la Válvula Aórtica Transcatéter , Enfermedades Vasculares/prevención & control , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/instrumentación , Bases de Datos Factuales , Femenino , Arteria Femoral/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Humanos , Masculino , Ohio , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Dispositivos de Acceso Vascular , Enfermedades Vasculares/diagnóstico por imagen , Enfermedades Vasculares/etiología
17.
Heart Surg Forum ; 22(4): E281-E282, 2019 07 02.
Artículo en Inglés | MEDLINE | ID: mdl-31398091

RESUMEN

We report a 62-year-old male who had severe aortic insufficiency after a homograft root replacement, requiring venoarterial extracorporeal membrane oxygenation prior to surgery due to profound cardiogenic shock. Severe aortic insufficiency is a contraindication for venoarterial extracorporeal membrane oxygenation, but we were able to stabilize the patient and successfully perform an urgent reoperative surgery.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Oxigenación por Membrana Extracorpórea/métodos , Complicaciones Posoperatorias/cirugía , Falla de Prótesis/efectos adversos , Reoperación , Choque Cardiogénico/etiología , Aloinjertos , Insuficiencia de la Válvula Aórtica/etiología , Contraindicaciones de los Procedimientos , Puente de Arteria Coronaria , Oxigenación por Membrana Extracorpórea/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Infarto del Miocardio con Elevación del ST/etiología , Terapia Recuperativa/métodos , Choque Cardiogénico/cirugía
18.
J Card Surg ; 34(8): 676-683, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31212385

RESUMEN

BACKGROUND AND AIM: To compare outcomes of patients treated with inhaled epoprostenol and low tidal volume ventilation during cardiopulmonary bypass with those who did not receive this medication in the operating room at all, and those who received it as a rescue therapy at the end of the case. METHODS: Retrospective chart review between 2014 and 2017, follow-up included the entire hospital stay. RESULTS: Seventy-one patients were included, and mean age was 54 years. 78.9% of the patients were male. Procedures included 96% (n = 68) aortic valve replacement, 28% (n = 20) reconstruction of the intravalvular fibrosa, and 13% (n = 9) repair of an endocarditis-related intracardiac fistula. Patients who received epoprostenol (iEpo) (treatment and rescue groups), when compared with the control group had more intra-aortic balloon pump placement (23% vs 2.5%, P = .018), open chest after surgery (32% vs 7.5%, P = .012), and duration of mechanical ventilation (8.3 ± 2.7 vs. 2.4 ± 0.4 days, P = 0.01). There was no significant difference between the two groups in terms of extracorporeal circulatory support (6.5% vs 2.5%, P = .577) and hospital death (13% vs 10%, P = .72). In a subanalysis, hospital death and duration of mechanical ventilation were higher in the recue group when compared with the treatment group (P = .004 and .056, respectively). CONCLUSIONS: Prophylactic application of iEpo with low tidal volume ventilation for an anticipated complex endocarditis operation may contribute to favorable outcome when compared with postoperative epoprostenol rescue.


Asunto(s)
Endocarditis/cirugía , Epoprostenol/administración & dosificación , Cuidados Intraoperatorios , Complicaciones Posoperatorias/prevención & control , Respiración Artificial/métodos , Síndrome de Dificultad Respiratoria/prevención & control , Administración por Inhalación , Procedimientos Quirúrgicos Cardíacos , Puente Cardiopulmonar , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia Respiratoria/prevención & control , Estudios Retrospectivos , Riesgo , Índice de Severidad de la Enfermedad , Volumen de Ventilación Pulmonar , Resultado del Tratamiento
19.
Ann Thorac Surg ; 108(5): 1314-1323, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31254508

RESUMEN

BACKGROUND: Reconstruction of the intervalvular fibrosa (IVF) for invasive double-valve infective endocarditis (IE) is a technically challenging operation. This study presents the long-term outcomes of two surgical techniques for IVF reconstruction. METHODS: From 1988 to 2017, 138 patients with invasive double-valve IE underwent surgical reconstruction of the IVF, along with double-valve replacement (Commando procedure, n = 86) or aortic valve replacement with mitral valve repair (hemi-Commando procedure, n = 52). Mean follow-up was 41 ± 5.9 months. RESULTS: Reoperation was required in 82% of patients, and 34% underwent emergency surgery. Pathologic features included positive blood cultures (90%), prosthetic valve IE (75%), aortic root abscess (78%), mitral annular abscess (24%), and intracardiac fistula (12%). There were 28 hospital deaths: 21 (24%) in the Commando group and 7 (14%) in the hemi-Commando group (P = .12). Overall survival at 1, 5, and 10 years was 67%, 48%, and 37%, respectively. Coronary artery disease, native valve IE, and causative organism (Staphylococcus aureus, coagulase-negative Staphylococcus, and viridans streptococci) were risk factors for late mortality. Freedom from reoperation at 1, 5, and 8 years was 87%, 74%, and 55%, respectively. Freedom from recurrent IE at 1, 5, and 8 years was 90%, 78%, and 67%, respectively. CONCLUSIONS: Although it is technically demanding, surgery for invasive IE involving IVF, which provides the only chance for cure, can be performed with reasonable clinical outcomes. In cases of IE invading the IVF and limited to the anterior mitral valve leaflet, a hemi-Commando procedure that includes mitral valve repair has improved early outcomes.


Asunto(s)
Válvula Aórtica/cirugía , Endocarditis Bacteriana/cirugía , Enfermedades de las Válvulas Cardíacas/microbiología , Enfermedades de las Válvulas Cardíacas/cirugía , Válvula Mitral/cirugía , Endocarditis Bacteriana/complicaciones , Femenino , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
20.
Ann Thorac Surg ; 108(3): 700-707, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31034827

RESUMEN

BACKGROUND: Damage to the cardiac conduction system requiring permanent pacemaker implantation is a complication of aortic valve replacement (AVR) that may importantly affect quality of life. We investigated the prevalence of and preprocedure risk factors for new permanent pacemakers after surgical (SAVR) and transcatheter AVR (TAVR) at a single institution. METHODS: Preoperative variables and baseline electrocardiograms were reviewed for 5807 patients undergoing elective SAVR, with or without coronary artery bypass grafting, and 1292 undergoing TAVR, with or without percutaneous coronary intervention, from 2006 to 2017 at Cleveland Clinic. Patients with previous permanent pacemakers were excluded. Risk factors for permanent pacemaker implantation were identified using multivariable logistic regression analysis. RESULTS: New permanent pacemakers were implanted in 151 (2.6%) after SAVR and in 125 (9.7%) after TAVR (whole group SAVR vs TAVR, P <.0001). Risk factors for pacemaker implantation after TAVR included preoperative conduction disturbances and type of prosthesis (SAPIEN, 9.5%; SAPIEN XT, 4.8%; SAPIEN 3, 10% [Edwards Lifesciences, Irvine, CA]; CoreValve, 30% [Medtronic, Minneapolis, MN]; and other TAVR, 10%). There were no reliable risk factors for pacemaker implantation after SAVR. Bicuspid valves, mechanical vs bioprosthetic valves, higher Society of Thoracic Surgeons risk score, and concomitant coronary artery bypass grafting were not associated with elevated risk. CONCLUSIONS: At a high-volume institution in the current era, establishing a baseline for pacemaker implantation after AVR is necessary. Preoperative conduction disturbances and transcatheter valve type affect its prevalence. These data provide a benchmark that should be taken into account when considering TAVR in low-risk patients.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Marcapaso Artificial/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Centros Médicos Académicos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Benchmarking , Estimulación Cardíaca Artificial/efectos adversos , Estudios de Cohortes , Femenino , Hospitales de Alto Volumen , Humanos , Cuidados a Largo Plazo , Masculino , Marcapaso Artificial/estadística & datos numéricos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/terapia , Prevalencia , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Análisis de Supervivencia , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...