Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 132
Filtrar
1.
J Am Heart Assoc ; 13(13): e9757, 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38934857

RESUMEN

BACKGROUND: Outcomes from cardiopulmonary resuscitation (CPR) following sudden cardiac arrest are suboptimal. Postresuscitation targeted temperature management has been shown to have benefit in subjects with sudden cardiac arrest due to ventricular fibrillation, but there are few data for outcomes from sudden cardiac arrest due to pulseless electrical activity. In addition, intra-CPR cooling is more effective than postresuscitation cooling. Physical cooling is associated with increased protein kinase B activity. Therefore, our group developed a novel peptide, TAT-PHLPP9c, which regulates protein kinase B. We hypothesized that when given during CPR, TAT-PHLPP9c would improve survival and neurologic outcomes following pulseless electrical activity arrest. METHODS AND RESULTS: In 24 female pigs, pulseless electrical activity was induced by inflating balloon catheters in the right coronary and left anterior descending arteries for ≈7 minutes. Advanced life support was initiated. In 12 control animals, epinephrine was given after 1 and 3 minutes. In 12 peptide-treated animals, 7.5 mg/kg TAT-PHLPP9c was also administered at 1 and 3 minutes of CPR. The balloons were removed after 2 minutes of support. Animals were recovered and neurologically scored 24 hours after return of spontaneous circulation. Return of spontaneous circulation was more common in the peptide group, but this difference was not significant (8/12 control versus 12/12 peptide; P=0.093), while fully intact neurologic survival was significantly more common in the peptide group (0/12 control versus 11/12 peptide; P<0.00001). TAT-PHLPP9c significantly increased myocardial nicotinamide adenine dinucleotide levels. CONCLUSIONS: TAT-PHLPP9c resulted in improved survival with full neurologic function after sudden cardiac arrest in a swine model of pulseless electrical activity, and the peptide shows potential as an intra-CPR pharmacologic agent.


Asunto(s)
Reanimación Cardiopulmonar , Modelos Animales de Enfermedad , Paro Cardíaco , Animales , Reanimación Cardiopulmonar/métodos , Femenino , Paro Cardíaco/terapia , Paro Cardíaco/fisiopatología , Paro Cardíaco/tratamiento farmacológico , Porcinos , Péptidos/administración & dosificación , Péptidos/farmacología , Factores de Tiempo
2.
J Med Syst ; 48(1): 57, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38801649

RESUMEN

Wearable electronics are increasingly common and useful as health monitoring devices, many of which feature the ability to record a single-lead electrocardiogram (ECG). However, recording the ECG commonly requires the user to touch the device to complete the lead circuit, which prevents continuous data acquisition. An alternative approach to enable continuous monitoring without user initiation is to embed the leads in a garment. This study assessed ECG data obtained from the YouCare device (a novel sensorized garment) via comparison with a conventional Holter monitor. A cohort of thirty patients (age range: 20-82 years; 16 females and 14 males) were enrolled and monitored for twenty-four hours with both the YouCare device and a Holter monitor. ECG data from both devices were qualitatively assessed by a panel of three expert cardiologists and quantitatively analyzed using specialized software. Patients also responded to a survey about the comfort of the YouCare device as compared to the Holter monitor. The YouCare device was assessed to have 70% of its ECG signals as "Good", 12% as "Acceptable", and 18% as "Not Readable". The R-wave, independently recorded by the YouCare device and Holter monitor, were synchronized within measurement error during 99.4% of cardiac cycles. In addition, patients found the YouCare device more comfortable than the Holter monitor (comfortable 22 vs. 5 and uncomfortable 1 vs. 18, respectively). Therefore, the quality of ECG data collected from the garment-based device was comparable to a Holter monitor when the signal was sufficiently acquired, and the garment was also comfortable.


Asunto(s)
Electrocardiografía Ambulatoria , Electrocardiografía , Humanos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Adulto , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/métodos , Anciano de 80 o más Años , Electrocardiografía/instrumentación , Electrocardiografía/métodos , Dispositivos Electrónicos Vestibles , Adulto Joven , Vestuario , Procesamiento de Señales Asistido por Computador/instrumentación
3.
Bioengineering (Basel) ; 11(3)2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38534496

RESUMEN

BACKGROUND: Wearable devices represent a new approach for monitoring key clinical parameters, such as ECG signals, for research and health purposes. These devices could outcompete medical devices in terms of affordability and use in out-clinic settings, allowing remote monitoring. The major limitation, especially when compared to implantable devices, is the presence of artifacts. Several authors reported a relevant percentage of recording time with poor/unusable traces for ECG, potentially hampering the use of these devices for this purpose. For this reason, it is of the utmost importance to develop a simple and inexpensive system enabling the user of the wearable devices to have immediate feedback on the quality of the acquired signal, allowing for real-time correction. METHODS: A simple algorithm that can work in real time to verify the quality of the ECG signal (acceptable and unacceptable) was validated. Based on simple statistical parameters, the algorithm was blindly tested by comparison with ECG tracings previously classified by two expert cardiologists. RESULTS: The classifications of 7200 10s-signal samples acquired on 20 patients with a commercial wearable ECG monitor were compared. The algorithm has an overall efficiency of approximately 95%, with a sensitivity of 94.7% and a specificity of 95.3%. CONCLUSIONS: The results demonstrate that even a simple algorithm can be used to classify signal coarseness, and this could allow real-time intervention by the subject or the technician.

4.
Blood Purif ; 53(5): 405-417, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38382484

RESUMEN

INTRODUCTION: The Anemia Control Model (ACM) is a certified medical device suggesting the optimal ESA and iron dosage for patients on hemodialysis. We sought to assess the effectiveness and safety of ACM in a large cohort of hemodialysis patients. METHODS: This is a retrospective study of dialysis patients treated in NephroCare centers between June 1, 2013 and December 31, 2019. We compared patients treated according to ACM suggestions and patients treated in clinics where ACM was not activated. We stratified patients belonging to the reference group by historical target achievement rates in their referral centers (tier 1: <70%; tier 2: 70-80%; tier 3: >80%). Groups were matched by propensity score. RESULTS: After matching, we obtained four groups with 85,512 patient-months each. ACM had 18% higher target achievement rate, 63% smaller inappropriate ESA administration rate, and 59% smaller severe anemia risk compared to Tier 1 centers (all p < 0.01). The corresponding risk ratios for ACM compared to Tier 2 centers were 1.08 (95% CI: 1.08-1.09), 0.49 (95% CI: 0.47-0.51), and 0.64 (95% CI: 0.61-0.68); for ACM compared to Tier 3 centers, 1.01 (95% CI: 1.01-1.02), 0.66 (95% CI: 0.63-0.69), and 0.94 (95% CI: 0.88-1.00), respectively. ACM was associated with statistically significant reductions in ESA dose administration. CONCLUSION: ACM was associated with increased hemoglobin target achievement rate, decreased inappropriate ESA usage and a decreased incidence of severe anemia among patients treated according to ACM suggestion.


Asunto(s)
Anemia , Eritropoyetina , Hematínicos , Humanos , Diálisis Renal/efectos adversos , Hematínicos/uso terapéutico , Hematínicos/efectos adversos , Estudios Retrospectivos , Anemia/tratamiento farmacológico , Anemia/etiología , Eritropoyetina/uso terapéutico , Eritropoyetina/efectos adversos , Hemoglobinas/análisis
5.
Blood Purif ; 53(2): 80-87, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38008072

RESUMEN

INTRODUCTION: The rapid advancement of artificial intelligence and big data analytics, including descriptive, diagnostic, predictive, and prescriptive analytics, has the potential to revolutionize many areas of medicine, including nephrology and dialysis. Artificial intelligence and big data analytics can be used to analyze large amounts of patient medical records, including laboratory results and imaging studies, to improve the accuracy of diagnosis, enhance early detection, identify patterns and trends, and personalize treatment plans for patients with kidney disease. Additionally, artificial intelligence and big data analytics can be used to identify patients' treatment who are not receiving adequate care, highlighting care inefficiencies in the dialysis provider, optimizing patient outcomes, reducing healthcare costs, and consequently creating values for all the involved stakeholders. OBJECTIVES: We present the results of a comprehensive survey aimed at exploring the attitudes of European physicians from eight countries working within a major hemodialysis network (Fresenius Medical Care NephroCare) toward the application of artificial intelligence in clinical practice. METHODS: An electronic survey on the implementation of artificial intelligence in hemodialysis clinics was distributed to 1,067 physicians. Of the 1,067 individuals invited to participate in the study, 404 (37.9%) professionals agreed to participate in the survey. RESULTS: The survey showed that a substantial proportion of respondents believe that artificial intelligence has the potential to support physicians in reducing medical malpractice or mistakes. CONCLUSION: While artificial intelligence's potential benefits are recognized in reducing medical errors and improving decision-making, concerns about treatment plan consistency, personalization, privacy, and the human aspects of patient care persist. Addressing these concerns will be crucial for successfully integrating artificial intelligence solutions in nephrology practice.


Asunto(s)
Inteligencia Artificial , Nefrología , Humanos , Nefrólogos , Diálisis Renal , Encuestas y Cuestionarios
6.
Clin Kidney J ; 16(11): 1878-1884, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37915897

RESUMEN

Healthcare systems worldwide are currently undergoing significant transformations in response to increasing costs, a shortage of healthcare professionals and the growing complexity of medical needs among the population. Value-based healthcare reimbursement systems are emerging as an attempt to incentivize patient-centricity and cost containment. From a technological perspective, the transition to digitalized services is intended to support these transformations. A Health Information System (HIS) is a technological solution designed to govern the data flow generated and consumed by healthcare professionals and administrative staff during the delivery of healthcare services. However, the exponential growth of digital capabilities and applied advanced analytics has expanded their traditional functionalities and brought the promise of automating administrative procedures and simple repetitive tasks, while enhancing the efficiency and outcomes of healthcare services by incorporating decision support tools for clinical management. The future of HIS is headed towards modular architectures that can facilitate implementation and adaptation to different environments and systems, as well as the integration of various tools, such as artificial intelligence (AI) models, in a seamless way. As an example, we present the experience and future developments of the European Clinical Database (EuCliD®). EuCliD is a multilingual HIS used by 20 000 nurses and physicians on a daily basis to manage 105 000 patients treated in 1100 clinics in 43 different countries. EuCliD encompasses patients' follow-up, automatic reporting and mobile applications while enabling efficient management of clinical processes. It is also designed to incorporate multiagent systems to automate repetitive tasks, AI modules and advanced dynamic dashboards.

7.
J Nephrol ; 36(7): 2001-2011, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37707692

RESUMEN

BACKGROUND: Intradialytic hypotension remains one of the most recurrent complications of dialysis sessions. Inadequate management can lead to adverse outcomes, highlighting the need to develop personalized approaches for the prevention of intradialytic hypotension. Here, we sought to develop and validate two AI-based risk models predicting the occurrence of symptomatic intradialytic hypotension at different time points. METHODS: The models were built using the XGBoost algorithm and they predict the occurrence of intradialytic hypotension in the next dialysis session and in the next month. The initial dataset, obtained from routinely collected data in the EuCliD® Database, was split to perform model derivation, training and validation. Model performance was evaluated by concordance statistic and calibration charts; the importance of features was assessed with the Shapley Additive Explanation (SHAP) methodology. RESULTS: The final dataset included 1,249,813 dialysis sessions, and the incidence rate of intradialytic hypotension was 10.07% (95% CI 10.02-10.13). Our models retained good discrimination (AUC around 0.8) and a suitable calibration yielding to the selection of three classification thresholds identifying four distinct risk groups. Variables providing the most significant impact on risk estimates were blood pressure dynamics and other metrics mirroring hemodynamic instability over time. CONCLUSIONS: Recurrent symptomatic intradialytic hypotension could be reliably and accurately predicted using routinely collected data during dialysis treatment and standard clinical care. Clinical application of these prediction models would allow for personalized risk-based interventions for preventing and managing intradialytic hypotension.


Asunto(s)
Hipotensión , Fallo Renal Crónico , Humanos , Triaje , Hipotensión/diagnóstico , Hipotensión/etiología , Hipotensión/prevención & control , Presión Sanguínea , Diálisis Renal/efectos adversos , Diálisis Renal/métodos , Inteligencia Artificial , Fallo Renal Crónico/terapia
8.
Sensors (Basel) ; 23(10)2023 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-37430719

RESUMEN

Worldwide, population aging and unhealthy lifestyles have increased the incidence of high-risk health conditions such as cardiovascular diseases, sleep apnea, and other conditions. Recently, to facilitate early identification and diagnosis, efforts have been made in the research and development of new wearable devices to make them smaller, more comfortable, more accurate, and increasingly compatible with artificial intelligence technologies. These efforts can pave the way to the longer and continuous health monitoring of different biosignals, including the real-time detection of diseases, thus providing more timely and accurate predictions of health events that can drastically improve the healthcare management of patients. Most recent reviews focus on a specific category of disease, the use of artificial intelligence in 12-lead electrocardiograms, or on wearable technology. However, we present recent advances in the use of electrocardiogram signals acquired with wearable devices or from publicly available databases and the analysis of such signals with artificial intelligence methods to detect and predict diseases. As expected, most of the available research focuses on heart diseases, sleep apnea, and other emerging areas, such as mental stress. From a methodological point of view, although traditional statistical methods and machine learning are still widely used, we observe an increasing use of more advanced deep learning methods, specifically architectures that can handle the complexity of biosignal data. These deep learning methods typically include convolutional and recurrent neural networks. Moreover, when proposing new artificial intelligence methods, we observe that the prevalent choice is to use publicly available databases rather than collecting new data.


Asunto(s)
Síndromes de la Apnea del Sueño , Dispositivos Electrónicos Vestibles , Humanos , Inteligencia Artificial , Electrocardiografía , Inteligencia
9.
Qual Life Res ; 32(10): 2939-2950, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37269433

RESUMEN

PURPOSE: Chronic pruritus significantly impairs hemodialysis patients' health status and quality of life (QOL) and it is associated with higher mortality rate, more frequent hospitalizations, poorer dialysis and medication adherence, and deteriorated mental status. However, pruritus is still underestimated, underdiagnosed, and undertreated in the real-life clinical scenario. We investigated prevalence, clinical characteristics, clinical correlates, severity as well as physical and psychological burden of chronic pruritus among adult hemodialysis patients in a large international real-world cohort. METHODS: We conducted a retrospective cross-sectional study of patients registered in 152 Fresenius Medical Care (FMC) NephroCare clinics located in Italy, France, Ireland, United Kingdom, and Spain. Demographic and medical data were retrieved from the EuCliD® (European Clinical) database, while information on pruritus and QoL were abstracted from KDQOL™-36 and 5-D Itch questionnaire scores. RESULTS: A total of 6221 patients were included, of which 1238 were from France, 163 Ireland, 1469 Italy, 2633 Spain, and 718 UK. The prevalence of mild-to-severe pruritus was 47.9% (n = 2977 patients). Increased pruritus severity was associated with increased use of antidepressants, antihistamines, and gabapentin. Patients with severe pruritus more likely suffered from diabetes, more frequently missed dialysis sessions, and underwent more hospitalizations due to infections. Both mental and physical QOL scores were progressively lower as the severity of pruritus increased; this association was robust to adjustment for potential confounders. CONCLUSION: This international real-world analysis confirms that chronic pruritus is a highly prevalent condition among dialysis patients and highlights its considerable burden on several dimensions of patients' life.


Asunto(s)
Diálisis Renal , Insuficiencia Renal Crónica , Adulto , Humanos , Calidad de Vida/psicología , Estudios Transversales , Estudios Retrospectivos , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/terapia , Aceptación de la Atención de Salud , Prurito/epidemiología , Prurito/etiología
10.
Biology (Basel) ; 12(3)2023 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-36979141

RESUMEN

Microalgae represent a growing innovative source of nutraceuticals such as carotenoids and phenolic compound which are naturally present within these single-celled organisms or can be induced in response to specific growth conditions. The presence of the unfavourable allelic variant in genes involved in the control of oxidative stress, due to one or more SNPs in gene encoding protein involved in the regulation of redox balance, can lead to pathological conditions such as insulin resistance, which, in turn, is directly involved in the pathogenesis of type 2 diabetes mellitus. In this review we provide an overview of the main SNPs in antioxidant genes involved in the promotion of insulin resistance with a focus on the potential role of microalgae-derived antioxidant molecules as novel nutritional tools to mitigate oxidative stress and improve insulin sensitivity.

11.
Cells ; 12(4)2023 02 09.
Artículo en Inglés | MEDLINE | ID: mdl-36831228

RESUMEN

Lipid membrane turnover and myelin repair play a central role in diseases and lesions of the central nervous system (CNS). The aim of the present study was to analyze lipid composition changes due to inflammatory conditions. We measured the fatty acid (FA) composition in erythrocytes (RBCs) and spinal cord tissue (gas chromatography) derived from mice affected by experimental allergic encephalomyelitis (EAE) in acute and remission phases; cholesterol membrane content (Filipin) and GM1 membrane assembly (CT-B) in EAE mouse RBCs, and in cultured neurons, oligodendroglial cells and macrophages exposed to inflammatory challenges. During the EAE acute phase, the RBC membrane showed a reduction in polyunsaturated FAs (PUFAs) and an increase in saturated FAs (SFAs) and the omega-6/omega-3 ratios, followed by a restoration to control levels in the remission phase in parallel with an increase in monounsaturated fatty acid residues. A decrease in PUFAs was also shown in the spinal cord. CT-B staining decreased and Filipin staining increased in RBCs during acute EAE, as well as in cultured macrophages, neurons and oligodendrocyte precursor cells exposed to inflammatory challenges. This regulation in lipid content suggests an increased cell membrane rigidity during the inflammatory phase of EAE and supports the investigation of peripheral cell membrane lipids as possible biomarkers for CNS lipid membrane concentration and assembly.


Asunto(s)
Encefalomielitis Autoinmune Experimental , Ácidos Grasos Omega-3 , Ratones , Animales , Filipina/metabolismo , Encefalomielitis Autoinmune Experimental/patología , Ácidos Grasos Insaturados/metabolismo , Inflamación/metabolismo , Eritrocitos/metabolismo , Membrana Celular/metabolismo , Lípidos de la Membrana/metabolismo , Vaina de Mielina/metabolismo
12.
Sensors (Basel) ; 23(3)2023 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-36772665

RESUMEN

Recent advancements in smart, wearable technologies have allowed the detection of various medical conditions. In particular, continuous collection and real-time analysis of electrocardiogram data have enabled the early identification of pathologic cardiac rhythms. Various algorithms to assess cardiac rhythms have been developed, but these utilize excessive computational power. Therefore, adoption to mobile platforms requires more computationally efficient algorithms that do not sacrifice correctness. This study presents a modified QRS detection algorithm, the AccYouRate Modified Pan-Tompkins (AMPT), which is a simplified version of the well-established Pan-Tompkins algorithm. Using archived ECG data from a variety of publicly available datasets, relative to the Pan-Tompkins, the AMPT algorithm demonstrated improved computational efficiency by 5-20×, while also universally enhancing correctness, both of which favor translation to a mobile platform for continuous, real-time QRS detection.


Asunto(s)
Algoritmos , Dispositivos Electrónicos Vestibles , Electrocardiografía , Procesamiento de Señales Asistido por Computador
13.
Nephrol Dial Transplant ; 38(7): 1700-1706, 2023 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-36649682

RESUMEN

BACKGROUND: Cold hemodialysis (HD) prevented intradialysis hypotension (IDH) in small, short-term, randomized trials in selected patients with IDH. Whether this treatments prevents IDH and mortality in the HD population at large is unknown. METHODS: We investigated the relationship between dialysate temperature and the risk of IDH, i.e. nadir blood pressure <90 mmHg (generalized estimating equation model) and all-cause mortality (Cox's regression) in an incident cohort of HD patients (n = 8071). To control for confounding by bias by indication and other factors we applied instrumental variables adjusting for case mix at facility level. RESULTS: Twenty-seven percent of patients in the study cohort were systematically treated with a dialysate temperature ≤35.5°C. Over a median follow-up of 13.6 months (interquartile range 5.2-26.1 months), a 0.5°C reduction of the dialysate temperature was associated with a small (-2.4%) reduction of the risk of IDH [odds ratio (OR) 0.976, 95% confidence interval (CI) 0.957-0.995, P = .013]. In case-mix, facility-level adjusted analysis, the association became much stronger (OR 0.67, 95% CI 0.63-0.72, risk reduction = 33%, P < .001). In contrast, colder dialysate temperature had no effect on mortality both in the unadjusted [hazard ratio (HR) (0.5°C decrease) 1.074, 95% CI 0.972-1.187, P = .16] and case-mix-adjusted analysis at facility level (HR 1.01, 95% CI 0.88-1.16, P = .84). Similar results were registered in additional analyses by instrumental variables applying the median dialysate temperature or the facility percentage of patients prescribed a dialysate temperature <36°C. Further analyses restricted to patients with recurrent IDH fully confirmed these findings. CONCLUSIONS: Cold HD was associated with IDH in the HD population but had no association with all-cause mortality.


Asunto(s)
Hipotensión , Fallo Renal Crónico , Humanos , Hipotensión/etiología , Hipotensión/prevención & control , Diálisis Renal/efectos adversos , Diálisis Renal/métodos , Presión Sanguínea , Soluciones para Diálisis , Fallo Renal Crónico/terapia , Fallo Renal Crónico/complicaciones
14.
IEEE ASME Trans Mechatron ; 28(4): 2405-2410, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39104914

RESUMEN

Effective radiation therapy aims to maximize the radiation dose delivered to the tumor while minimizing damage to the surrounding healthy tissues, which can be a challenging task when the tissue-tumor space is small. To eliminate the damage to healthy tissue, it is now possible to inject biocompatible hydrogels between cancerous targets and surrounding tissues to create a spacer pocket. Conventional methods have limitations in poor target visualization and device tracking. In this paper, we leverage our MR-tracking technique to develop a novel injection needle for hydrogel spacer deployment. Herein, we present the working principle and fabrication method, followed by benchtop validation in an agar phantom, and MRI-guided validation in tissue-mimic prostate phantom and sexually mature female swine. Animal trials indicated that the spacer pockets in the rectovaginal septum can be accurately visualized on T2-weighted MRI. The experimental results showed that the vaginal-rectal spacing was successfully increased by 12 ± 2 mm anterior-posterior.

15.
Ultrasound J ; 14(1): 31, 2022 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-35895165

RESUMEN

OBJECTIVES: The purpose of this study is to provide expert consensus recommendations to establish a global ultrasound curriculum for undergraduate medical students. METHODS: 64 multi-disciplinary ultrasound experts from 16 countries, 50 multi-disciplinary ultrasound consultants, and 21 medical students and residents contributed to these recommendations. A modified Delphi consensus method was used that included a systematic literature search, evaluation of the quality of literature by the GRADE system, and the RAND appropriateness method for panel judgment and consensus decisions. The process included four in-person international discussion sessions and two rounds of online voting. RESULTS: A total of 332 consensus conference statements in four curricular domains were considered: (1) curricular scope (4 statements), (2) curricular rationale (10 statements), (3) curricular characteristics (14 statements), and (4) curricular content (304 statements). Of these 332 statements, 145 were recommended, 126 were strongly recommended, and 61 were not recommended. Important aspects of an undergraduate ultrasound curriculum identified include curricular integration across the basic and clinical sciences and a competency and entrustable professional activity-based model. The curriculum should form the foundation of a life-long continuum of ultrasound education that prepares students for advanced training and patient care. In addition, the curriculum should complement and support the medical school curriculum as a whole with enhanced understanding of anatomy, physiology, pathophysiological processes and clinical practice without displacing other important undergraduate learning. The content of the curriculum should be appropriate for the medical student level of training, evidence and expert opinion based, and include ongoing collaborative research and development to ensure optimum educational value and patient care. CONCLUSIONS: The international consensus conference has provided the first comprehensive document of recommendations for a basic ultrasound curriculum. The document reflects the opinion of a diverse and representative group of international expert ultrasound practitioners, educators, and learners. These recommendations can standardize undergraduate medical student ultrasound education while serving as a basis for additional research in medical education and the application of ultrasound in clinical practice.

16.
Disaster Med Public Health Prep ; 17: e194, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-35361295

RESUMEN

OBJECTIVES: In mass casualty scenarios, patients with apparent hemodynamic and respiratory stability might have occult life-threatening injuries. These patients could benefit from more accurate triage methods. This study assessed the impact of point-of-care ultrasound on the accuracy of secondary triage conducted at an advanced medical post to enhance the detection of patients who, despite their apparent clinically stable condition, could benefit from earlier evacuation to definitive care or immediate life-saving treatment. METHODS: A mass casualty simulated event consisting of a bomb blast in a remote area was conducted with 10 simulated casualties classified as YELLOW at the primary triage scene; patients were evaluated by 4 physicians at an advanced medical post. Three patients had, respectively, hemoperitoneum, pneumothorax, and hemothorax. Only 2 physicians had sonographic information. RESULTS: All 4 physicians were able to suspect hemoperitoneum as a possible critical condition to be managed first, but only physicians with additional sonographic information accurately detected pneumothorax and hemothorax, thus deciding to immediately evacuate or treat.


Asunto(s)
Servicios Médicos de Urgencia , Incidentes con Víctimas en Masa , Neumotórax , Humanos , Triaje/métodos , Servicios Médicos de Urgencia/métodos , Proyectos Piloto , Hemoperitoneo , Hemotórax/diagnóstico por imagen , Hemotórax/etiología , Sistemas de Atención de Punto
17.
Biology (Basel) ; 11(3)2022 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-35336766

RESUMEN

Background: Weight loss through physical exercise is warranted among obese individuals. Recently, a greater benefit in cardiorespiratory fitness was achievable with high-intensity interval training (HIIT) as compared with moderate intensity continuous training. The beneficial effect of training on CV health might be related to a specific modulation of circulating irisin, an adypo-myokine implicated in the regulation of energy expenditure. Methods: The present study investigates the circulating plasma levels of irisin at baseline and in response to 12-week of training program either with HIIT or moderate-intensity continuous training (MICT) among young female and male obese subjects. Clinical, anthropometric, and training characteristics for each participant were available. A sex-disaggregated data for circulating plasma levels of irisin pre- and post-training are provided as well as an adjusted multivariate linear regression model to identify the determinants of post-training irisin levels. Results: Data from a total of 32 obese healthy individuals (47% female, mean age 38.7 years, mean BMI 35.6 kg/m2), randomized in a 1:1 manner to HIIT or MICT were analyzed. Circulating plasma levels of irisin similarly and significantly decreased in both MICT and HIIT interventional groups. Females had higher post-exercise irisin levels than males (6.32 [5.51-6.75] vs. 4.97 [4.57-5.72] µg/mL, p = 0.001). When stratified by an interventional group, a statistically significant difference was observed only for the MICT group (male, 4.76 [4.20-5.45] µg/mL vs. female 6.48 [4.88-6.84] µg/mL p = 0.03). The circulating post-training level of irisin was independently associated with post-training fat-free mass (ß -0.34, 95% confidence interval, CI -0.062, -0.006, p = 0.019) in a model adjusted confounders. When female sex was added into the adjusted model, it was retained as the only factor independently associated with irisin levels (ß 1.22, 95% CI, 0.50, 1.93, p = 0.002). Conclusions: In obese healthy subjects, circulating irisin levels were reduced in response to 12-weeks of exercise involving either HIIT or MICT. A sex-specific differences in circulating irisin levels at baseline and as biological response to chronic exercise was described. Sex-specific biological response of irisin to exercise should be further explored to tailor sex-specific training approaches for improving the cardiovascular health of obese healthy subjects.

18.
Heart Rhythm ; 19(7): 1165-1173, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35240311

RESUMEN

BACKGROUND: External defibrillators are used for arrhythmia cardioversion and for defibrillating during cardiac arrest. During defibrillation, short-duration biphasic pulses cause intense motion due to rapid chest-wall muscle contraction. A reduced motion external defibrillator (RMD) was constructed by integrating a commercial defibrillator with a Tetanizing-waveform generator. A long-duration, low-amplitude, tetanizing waveform slowly stimulated the chest musculature before the biphasic pulse, reducing muscle contraction during the shock. OBJECTIVE: The purpose of this study was to evaluate RMD defibrillation in swine for subject motion during defibrillation pulses and for defibrillation effectiveness. RMD defibrillation can reduce the duration of arrhythmia ablation therapy or simplify cardioversion procedures. METHODS: The tetanizing unit delivered a triangular 1-kHz pulse of 0.25- to 2.0-second duration and 10- to 100-V peak amplitude, subsequently triggering the conventional defibrillator to output standard 1- to 200-J energy biphasic pulses at the next R wave. Forward limb motion was evaluated by measuring peak acceleration and limb work during RMD (tetanizing + biphasic) or biphasic pulse-only waveforms at 10-3-second sampling rate. Seven swine were arrested electrically and subsequently defibrillated. Biphasic pulse-only and RMD defibrillations were repeated 25-35 times per swine, varying tetanizing parameters and biphasic pulse energy. Defibrillation thresholds (DFTs) were established by measuring the minimum energy required to restore sinus rhythm with biphasic pulse-only or RMD defibrillations. RESULTS: Two forward-limb acceleration peaks occurred during both the tetanizing waveform and biphasic pulse, indicating rapid and slower nociceptic (pain sensation) nerve fiber activation. Optimal RMD tetanizing parameters (25-35 V, 0.25- to 0.75-second duration), relative to biphasic pulse-only defibrillations, resulted in 74% ± 10% smaller peak accelerations and 85% ± 10% reduced limb work. DFT energies were identical when comparing RMD to biphasic pulse-only defibrillations. CONCLUSION: Relative to conventional defibrillations, RMD defibrillations maintain rhythm restoration efficiency with drastically reduced subject motion.


Asunto(s)
Cardioversión Eléctrica , Paro Cardíaco , Animales , Arritmias Cardíacas , Desfibriladores , Cardioversión Eléctrica/métodos , Porcinos , Fibrilación Ventricular/terapia
19.
Histochem Cell Biol ; 157(5): 497-511, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35235045

RESUMEN

Understanding the inner morphology of intact tissues is one of the most competitive challenges in modern biology. Since the beginning of the twentieth century, optical tissue clearing (OTC) has provided solutions for volumetric imaging, allowing the microscopic visualization of thick sections of tissue, organoids, up to whole organs and organisms (for example, mouse or rat). Recently, tissue clearing has also been introduced in clinical settings to achieve a more accurate diagnosis with the support of 3D imaging. This review aims to give an overview of the most recent developments in OTC and 3D imaging and to illustrate their role in the field of medical diagnosis, with a specific focus on clinical applications.


Asunto(s)
Imagenología Tridimensional , Organoides , Animales , Imagenología Tridimensional/métodos , Ratones , Imagen Óptica/métodos , Ratas
20.
J Intern Med ; 291(2): 224-231, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34437741

RESUMEN

BACKGROUND: Asymptomatic patients with Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) can develop hypercoagulable conditions and acute vascular events. The objective of this study is to determine whether SARS-CoV-2 was present in resected specimens from patients with acute bowel ischemia, but asymptomatic for Coronavirus Disease 2019 (COVID-19) and with persistently real-time polymerase chain reaction negative pharyngeal swab. METHODS: Three consecutive patients presented severe abdominal symptoms due to extensive ischemia and necrosis of the bowel, with co-existent thrombosis of abdominal blood vessels. None had the usual manifestations of COVID-19, and repeated pharyngeal swabs tested negative. They underwent emergency surgery with intestinal resection. Immunohistochemical testing for SARS-CoV-2 on resected tissue was performed. RESULTS: All tested samples were strongly positive for SARS-CoV-2. CONCLUSIONS: This is the first case report in which patients with severe intestinal symptoms presented a marked SARS-CoV-2 positivity in the resected tissues, without any usual clinical manifestations of COVID-19. These results suggest that the patients might be infected with SARS-CoV-2 presenting acute abdominal distress but without respiratory or constitutional symptoms.


Asunto(s)
COVID-19 , Intestino Grueso/patología , Isquemia , COVID-19/patología , Humanos , Isquemia/diagnóstico , Isquemia/virología , Necrosis , Reacción en Cadena en Tiempo Real de la Polimerasa , SARS-CoV-2 , Trombosis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...