Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Clin Ophthalmol ; 17: 3165-3176, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37901285

RESUMEN

Purpose: The purpose of this study was to evaluate the performance of verofilcon A daily disposable contact lenses (CL) in CL wearers who identified themselves as heavy digital device users. Patients and Methods: This prospective, non-masked, open-label study enrolled CL wearers who reported ≥6 hours digital device use per day. Participants were dispensed with the verofilcon A study lenses for 14±2 days, to be worn for at least 5 days a week and 10 hours per day, while continuing their normal routine of digital device use. Participants rated the lens performance at the Day 14 visit using a 0-100 (with 100 being best) scale. Ratings were completed at lens insertion, after 6 hours of digital device use, just before CL removal and for overall experience. Participants also completed a 4-point (strongly agree/disagree, slightly agree/disagree) Likert scale-based questionnaire. Results: Thirty-two participants were eligible and completed the study (27 females; age 25.8 ± 6.0 years, ranging from 19 to 40). Overall lens performance ratings at the Day 14 visit (mean ± standard deviation) for comfort, dryness, and clarity of vision were 91 ± 11, 88 ± 11, and 92 ± 9, respectively. Subjective ratings were stable throughout the day with no significant differences after insertion, after 6 hours of digital device use and before CL removal (all p>0.05). The majority of participants agreed that the study lenses performed well, provided good all-day comfort (28/32; p<0.01) and good all-day vision (29/32; p<0.01). Participants also agreed that after ≥6 hours of digital device use they were satisfied with CL comfort (27/32; p<0.01), vision (29/32; p<0.01) and that the lenses provided good performance (26/32; p<0.01). Conclusion: Verofilcon A lenses were found to perform well, with high ratings for comfort, dryness and vision that remained high throughout the day, during extensive digital device use.

2.
Ocul Surf ; 29: 537-546, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37478969

RESUMEN

PURPOSE: Meibomian gland dysfunction (MGD) is a chronic progressive disease with downstream effects on ocular signs and symptoms. AZR-MD-001 is a selenium sulfide ophthalmic ointment that was investigated as a potential treatment option for patients with MGD. METHODS: A Phase 2, multi-center, double-masked, parallel group study was conducted across 29 sites, with 245 patients randomized 1:1:1 to AZR-MD-001 0.5%, AZR-MD-001 1.0% or vehicle applied to the lower eyelid, twice weekly. Patients were eligible for the trial if they presented with signs and symptoms of MGD. Co-primary efficacy endpoints were the changes from baseline in number of open glands (Meibomian Glands Yielding Liquid Secretion [MGYLS] score) and patient-reported ocular surface symptoms (Ocular Surface Disease Index [OSDI] total score) at Month 3. Efficacy outcomes were captured at Day 14, Month 1.5 and Month 3. Safety and tolerability were assessed for treatment-emergent adverse events (TEAEs). RESULTS: AZR-MD-001 0.5% (n = 82 patients) treatment resulted in significant improvements in MGYLS score, with patients experiencing an average increase from baseline of 4.2 and 2.4 open glands secreting meibum for the drug and vehicle, respectively (p < 0.001) and from baseline a mean OSDI total score improvement of 7.3 and 3.8 for the drug and vehicle, respectively (p < 0.05). Most TEAEs were mild and transient, with 3 serious adverse events (SAEs) reported with AZR-MD-001 (none related to study drug). CONCLUSIONS: Co-primary endpoints were met for AZR-MD-001 0.5% at Month 3, with a statistically significant improvement in the signs and symptoms of MGD. AZR-MD-001 was safe and well tolerated. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03652051, ANZCTR Registration Number: AZ201801.

3.
Ocul Surf ; 29: 77-130, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37061220

RESUMEN

In this report the use of eye cosmetic products and procedures and how this represents a lifestyle challenge that may exacerbate or promote the development of ocular surface and adnexal disease is discussed. Multiple aspects of eye cosmetics are addressed, including their history and market value, psychological and social impacts, possible problems associated with cosmetic ingredients, products, and procedures, and regulations for eye cosmetic use. In addition, a systematic review that critically appraises randomized controlled trial evidence concerning the ocular effects of eyelash growth products is included. The findings of this systematic review highlight the evidence gaps and indicate future directions for research to focus on ocular surface outcomes associated with eyelash growth products.


Asunto(s)
Cosméticos , Oftalmopatías , Humanos , Ojo , Oftalmopatías/etiología , Cosméticos/efectos adversos , Ensayos Clínicos Controlados Aleatorios como Asunto
4.
Cont Lens Anterior Eye ; 45(5): 101579, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35246387

RESUMEN

PURPOSE: To explore the impact of subjective factors (lens handling, comfort and vision) on overall single vision contact lens satisfaction. METHODS: Correlation analysis of a prospective, randomised, double-masked, bilateral crossover study involving 55 adapted lens wearers fitted with somofilcon A (SiHy) (clariti® 1 day, CooperVision) and etafilcon A (Hy) (1 DAY ACUVUE® MOIST, Johnson & Johnson Vision) was conducted. Subjective ratings of lens handling, comfort and vision collected after 1 week of lens wear for each lens type were correlated with overall satisfaction. Data were analysed by combining data for both lens types and also for each lens separately. RESULTS: For the combined analysis, significant correlations (p < 0.01) were found between subjective ratings of overall satisfaction and ratings of handing for application (r = 0.64), handling for removal (r = 0.50), comfort upon application (r = 0.59), comfort at end of day (r = 0.61), overall satisfaction with comfort (r = 0.88) and overall satisfaction with vision (r = 0.64). Correlation analysis of the per lens data showed that lens specific correlations of overall satisfaction with handling for lens application varied greatly with lens material (SiHy: r = 0.26, p = 0.05 vs Hy: r = 0.72, p < 0.01). Correlation strength of comfort upon application/at end of day with overall satisfaction also varied with lens material (Application: SiHy: r = 0.40 vs Hy: r = 0.61; End of day: SiHy: r = 0.76 vs Hy: r = 0.58; all p ≤ 0.01). CONCLUSION: Overall satisfaction was significantly correlated with the specific subjective evaluations of handling, vision and comfort. Correlations of overall satisfaction and ease of handling for each lens type suggest that, for habitual contact lens wearers, dissatisfaction with handling at the time of lens application can play a major role in overall dissatisfaction with a lens. Handling for application had a similar correlation (r) value as vision, suggesting that handling for application should not be underestimated when considering overall patient satisfaction.


Asunto(s)
Lentes de Contacto Hidrofílicos , Estudios Cruzados , Humanos , Satisfacción del Paciente , Satisfacción Personal , Estudios Prospectivos , Visión Ocular
5.
Ann Neurol ; 91(1): 66-77, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34761434

RESUMEN

OBJECTIVE: Small fiber neuropathy (SFN) is clinically and etiologically heterogeneous. Although autoimmunity has been postulated to be pathophysiologically important in SFN, few autoantibodies have been described. We aimed to identify autoantibodies associated with idiopathic SFN (iSFN) by a novel high-throughput protein microarray platform that captures autoantibodies expressed in the native conformational state. METHODS: Sera from 58 SFN patients and 20 age- and gender-matched healthy controls (HCs) were screened against >1,600 immune-related antigens. Fluorescent unit readout and postassay imaging were performed, followed by composite data normalization and protein fold change (pFC) analysis. Analysis of an independent validation cohort of 33 SFN patients against the same 20 HCs was conducted to identify reproducible proteins in both cohorts. RESULTS: Nine autoantibodies were screened with statistical significance and pFC criteria in both cohorts, with at least 50% change in serum levels. Three proteins showed consistently high fold changes in main and validation cohorts: MX1 (FC = 2.99 and 3.07, respectively, p = 0.003, q = 0.076), DBNL (FC = 2.11 and 2.16, respectively, p = 0.009, q < 0.003), and KRT8 (FC = 1.65 and 1.70, respectively, p = 0.043, q < 0.003). Further subgroup analysis into iSFN and SFN by secondary causes (secondary SFN) in the main cohort showed that MX1 is higher in iSFN compared to secondary SFN (FC = 1.61 vs 0.106, p = 0.009). INTERPRETATION: Novel autoantibodies MX1, DBNL, and KRT8 are found in iSFN. MX1 may allow diagnostic subtyping of iSFN patients. ANN NEUROL 2022;91:66-77.


Asunto(s)
Autoanticuerpos/inmunología , Autoantígenos/inmunología , Neuropatía de Fibras Pequeñas/inmunología , Adulto , Anciano , Autoanticuerpos/sangre , Estudios de Cohortes , Femenino , Humanos , Queratina-8/inmunología , Masculino , Proteínas de Microfilamentos/inmunología , Persona de Mediana Edad , Proteínas de Resistencia a Mixovirus/inmunología , Neuropatía de Fibras Pequeñas/sangre , Dominios Homologos src/inmunología
6.
Optom Vis Sci ; 99(1): 67-75, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34882608

RESUMEN

SIGNIFICANCE: Supplementing diet with a novel combination of omega-3 and omega-6 fatty acids significantly improved symptoms in extremely symptomatic participants with dry eye disease (DED). PURPOSE: This study aimed to determine the effect of daily intake of a novel combination of essential fatty acids on signs and symptoms of DED. METHODS: Participants with moderate to severe DED were enrolled in a prospective, randomized, double-masked parallel group study. Participants ingested either the treatment supplement containing omega-3 and omega-6 fatty acids (1200 mg eicosapentaenoic acid, 300 mg docosahexaenoic acid, 150 mg γ-linoleic acid) or the placebo (coconut and olive oil) daily for 3 months. To determine compliance, Omega-3 Index blood tests were conducted. At baseline and at 1 and 3 months, the following assessments were conducted: Ocular Surface Disease Index (OSDI) questionnaire and Symptom Assessment Questionnaire in Dry Eye, noninvasive tear breakup time, tear meniscus height, tear osmolarity, ocular redness, surface staining, Schirmer test, and meibography. RESULTS: Fifty participants (mean ± standard deviation baseline OSDI score, 52.2 ± 16.5) completed the study: 24 randomized to treatment and 26 randomized to placebo. Although there was an improvement in OSDI score at 3 months for both groups (treatment: -13.4 points, P = .003; placebo: -7.8 points, P = .02), participants with baseline OSDI scores >52 demonstrated an even larger significant improvement in symptoms with the treatment at 3 months compared with baseline (n = 13, -20.8 points, P = .002). There were no significant changes in any of the ocular assessments at 1 or 3 months (all P > .05). After 3 months, Omega-3 Index increased by 34% in the treatment group (baseline, 5.3 ± 0.8; 3 months, 8.0 ± 2.1; P < .001) and did not change in the placebo group (baseline, 4.8 ± 0.8; 3 months, 4.8 ± 0.6; P = .95). CONCLUSIONS: Supplementation with eicosapentaenoic acid, docosahexaenoic acid, and γ-linoleic acid resulted in a significant and clinically meaningful improvement of dry eye symptoms in extremely symptomatic participants with DED (OSDI ≥52).


Asunto(s)
Síndromes de Ojo Seco , Ácidos Grasos Omega-3 , Suplementos Dietéticos , Ácidos Docosahexaenoicos/uso terapéutico , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/tratamiento farmacológico , Ácido Eicosapentaenoico/uso terapéutico , Ácidos Grasos Omega-3/uso terapéutico , Ácidos Grasos Omega-6/uso terapéutico , Humanos , Ácidos Linoleicos/uso terapéutico , Estudios Prospectivos , Lágrimas
7.
Brain Sci ; 11(8)2021 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-34439587

RESUMEN

Impaired sense of smell occurs in a fraction of patients with COVID-19 infection, but its effect on cerebral activity is unknown. Thus, this case report investigated the effect of COVID-19 infection on frontotemporal cortex activity during olfactory stimuli. In this preliminary study, patients who recovered from COVID-19 infection (n = 6) and healthy controls who never contracted COVID-19 (n = 6) were recruited. Relative changes in frontotemporal cortex oxy-hemoglobin during olfactory stimuli was acquired using functional near-infrared spectroscopy (fNIRS). The area under curve (AUC) of oxy-hemoglobin for the time interval 5 s before and 15 s after olfactory stimuli was derived. In addition, olfactory function was assessed using the Sniffin' Sticks 12-identification test (SIT-12). Patients had lower SIT-12 scores than healthy controls (p = 0.026), but there were no differences in oxy-hemoglobin AUC between healthy controls and patients (p > 0.05). This suggests that past COVID-19 infection may not affect frontotemporal cortex function, and these preliminary results need to be verified in larger samples.

8.
Cont Lens Anterior Eye ; 44(2): 330-367, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33775382

RESUMEN

Contact lens-related complications are common, affecting around one third of wearers, although most are mild and easily managed. Contact lenses have well-defined anatomical and physiological effects on the ocular surface and can result in other consequences due to the presence of a biologically active material. A contact lens interacts with the tear film, ocular surface, skin, endogenous and environmental microorganisms, components of care solutions and other antigens which may result in disease specific to contact lens wear, such as metabolic or hypersensitivity disorders. Contact lens wear may also modify the epidemiology or pathophysiology of recognised conditions, such as papillary conjunctivitis or microbial keratitis. Wearers may also present with intercurrent disease, meaning concomitant or pre-existing conditions unrelated to contact lens wear, such as allergic eye disease or blepharitis, which may complicate the diagnosis and management of contact lens-related disease. Complications can be grouped into corneal infection (microbial keratitis), corneal inflammation (sterile keratitis), metabolic conditions (epithelial: microcysts, vacuoles, bullae, tight lens syndrome, epithelial oedema; stromal: superficial and deep neovascularisation, stromal oedema [striae/folds], endothelial: blebs, polymegethism/ pleomorphism), mechanical (corneal abrasion, corneal erosion, lens binding, warpage/refractive error changes; superior epithelial arcuate lesion, mucin balls, conjunctival epithelial flaps, ptosis, discomfort), toxic and allergic disorders (papillary conjunctivitis, solution-induced corneal staining, incomplete neutralisation of peroxide, Limbal Stem Cell Deficiency), tear resurfacing disorders/dry eye (contact lens-induced dry eye, Meibomian gland dysfunction, lid wiper epitheliopathy, lid parallel conjunctival folds, inferior closure stain, 3 and 9 o'clock stain, dellen, dimple veil) or contact lens discomfort. This report summarises the best available evidence for the classification, epidemiology, pathophysiology, management and prevention of contact lens-related complications in addition to presenting strategies for optimising contact lens wear.


Asunto(s)
Lentes de Contacto Hidrofílicos , Lentes de Contacto , Enfermedades de la Córnea , Síndromes de Ojo Seco , Conjuntiva , Lentes de Contacto/efectos adversos , Enfermedades de la Córnea/etiología , Humanos , Lágrimas
9.
Optom Vis Sci ; 98(2): 113-120, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33534379

RESUMEN

SIGNIFICANCE: In this study, assessments of conjunctival redness were performed to evaluate whether patients with or without dry eye disease (DED) could be discriminated based on this measure. Our findings suggest that subjectively grading redness by quadrant, as opposed to automated en face measurements, may be more suitable for this purpose. PURPOSE: This study aimed to quantify bulbar redness using the validated bulbar redness (VBR) grading scale and an automated objective method (Oculus Keratograph 5M; K5M) in participants with DED and non-DED controls. METHODS: Participants with DED (Ocular Surface Disease Index score ≥20 and Oxford scale corneal staining ≥2) and controls (Ocular Surface Disease Index score ≤10 and corneal staining ≤1) attended two study visits. In part 1A of visit 1, baseline bulbar redness was graded with the VBR scale in each conjunctival quadrant of both eyes, followed by automated measurements of temporal and nasal redness with the K5M. This was immediately followed by part 1B, during which a topical vasoconstrictor was instilled into both eyes. Redness assessments were repeated 5 and 30 minutes after instillation with both instruments. Participants returned 14 days later for visit 2, where the same assessments as for visit 1A were repeated. RESULTS: Seventy-four participants (50 DED and 24 controls) completed the study. There were statistically significant differences in redness between the DED and control groups when assessed with the VBR scale (14/16 comparisons; all, P < .05), whereas no significant differences in K5M-derived redness between the DED and non-DED groups were found at any location or time point. Both subjective and objective instruments detected statistically significant reductions in redness 5 and 30 minutes after instillation of the vasoconstrictor (all, P < .01). CONCLUSIONS: Although both subjective and objective instruments were sensitive to detecting changes in redness induced by vasoconstriction, statistically significant differences in redness between DED and control groups were only found using the VBR scale.


Asunto(s)
Enfermedades de la Conjuntiva/clasificación , Diagnóstico por Computador/métodos , Técnicas de Diagnóstico Oftalmológico/instrumentación , Síndromes de Ojo Seco/diagnóstico , Hiperemia/clasificación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Hiperemia/diagnóstico , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Adulto Joven
10.
Eye Contact Lens ; 47(5): 277-282, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33290295

RESUMEN

OBJECTIVES: To retrospectively compare frequency of contact lens (CL) complications in soft CL users of hydrogen peroxide (H2O2) and multipurpose solutions (MPS). METHODS: This was a multicenter, retrospective chart review of CL records from each patient's three most recent eye examinations at academic and private practices. Patients must have used the same solution type for at least 3 years. Univariate analyses were conducted using t tests, and chi-square or Fisher's exact test for categorical measures. RESULTS: There were 1,137 patients included, with 670 (59%) using MPS and 467 (41%) H2O2. In total, 706 (62%) experienced at least one complication; 409 used MPS and 297 used H2O2. There was no difference in the proportion of patients experiencing at least one complication between MPS (61%) and H2O2 (64%) (P=0.38). Multipurpose solutions users were more likely to report discomfort compared with H2O2 users (P=0.04). Presumed microbial keratitis was experienced by 16 MPS and nine H2O2 users (P=0.60). CONCLUSIONS: No significant differences were found in the frequency of CL complications between MPS and H2O2. H2O2 users were less likely to report discomfort and thus switching to a H2O2 system may be an alternative in CL users with discomfort.


Asunto(s)
Lentes de Contacto Hidrofílicos , Queratitis , Soluciones para Lentes de Contacto/efectos adversos , Humanos , Peróxido de Hidrógeno/efectos adversos , Estudios Retrospectivos , Estados Unidos/epidemiología
11.
Brain Behav Immun ; 88: 559-565, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32330593

RESUMEN

OBJECTIVE: Since the declaration of the coronavirus 2019 (COVID-19) outbreak as pandemic, there are reports on the increased prevalence of physical symptoms observed in the general population. We investigated the association between psychological outcomes and physical symptoms among healthcare workers. METHODS: Healthcare workers from 5 major hospitals, involved in the care for COVID-19 patients, in Singapore and India were invited to participate in a study by performing a self-administered questionnaire within the period of February 19 to April 17, 2020. Healthcare workers included doctors, nurses, allied healthcare workers, administrators, clerical staff and maintenance workers. This questionnaire collected information on demographics, medical history, symptom prevalence in the past month, Depression Anxiety Stress Scales (DASS-21) and the Impact of Events Scale-Revised (IES-R) instrument. The prevalence of physical symptoms displayed by healthcare workers and the associations between physical symptoms and psychological outcomes of depression, anxiety, stress, and post-traumatic stress disorder (PTSD) were evaluated. RESULTS: Out of the 906 healthcare workers who participated in the survey, 48 (5.3%) screened positive for moderate to very-severe depression, 79 (8.7%) for moderate to extremely-severe anxiety, 20 (2.2%) for moderate to extremely-severe stress, and 34 (3.8%) for moderate to severe levels of psychological distress. The commonest reported symptom was headache (32.3%), with a large number of participants (33.4%) reporting more than four symptoms. Participants who had experienced symptoms in the preceding month were more likely to be older, have pre-existing comorbidities and a positive screen for depression, anxiety, stress, and PTSD. After adjusting for age, gender and comorbidities, it was found that depression (OR 2.79, 95% CI 1.54-5.07, p = 0.001), anxiety (OR 2.18, 95% CI 1.36-3.48, p = 0.001), stress (OR 3.06, 95% CI 1.27-7.41, p = 0.13), and PTSD (OR 2.20, 95% CI 1.12-4.35, p = 0.023) remained significantly associated with the presence of physical symptoms experienced in the preceding month. Linear regression revealed that the presence of physical symptoms was associated with higher mean scores in the IES-R, DASS Anxiety, Stress and Depression subscales. CONCLUSIONS: Our study demonstrates a significant association between the prevalence of physical symptoms and psychological outcomes among healthcare workers during the COVID-19 outbreak. We postulate that this association may be bi-directional, and that timely psychological interventions for healthcare workers with physical symptoms should be considered once an infection has been excluded.


Asunto(s)
Ansiedad/epidemiología , Infecciones por Coronavirus , Depresión/epidemiología , Personal de Salud/estadística & datos numéricos , Pandemias , Neumonía Viral , Trastornos por Estrés Postraumático/epidemiología , Estrés Psicológico/epidemiología , Adulto , Técnicos Medios en Salud/psicología , Técnicos Medios en Salud/estadística & datos numéricos , Betacoronavirus , COVID-19 , Femenino , Cefalea/epidemiología , Personal de Salud/psicología , Humanos , India/epidemiología , Internacionalidad , Letargia/epidemiología , Masculino , Enfermeras y Enfermeros/psicología , Enfermeras y Enfermeros/estadística & datos numéricos , Faringitis/epidemiología , Médicos/psicología , Médicos/estadística & datos numéricos , Prevalencia , SARS-CoV-2 , Singapur/epidemiología , Trastornos del Inicio y del Mantenimiento del Sueño/epidemiología , Encuestas y Cuestionarios
13.
Clin Ophthalmol ; 13: 1193-1202, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31371916

RESUMEN

Purpose: To evaluate ocular physiological responses to etafilcon A multifocal (etMF) daily disposable (DD) lenses after 4 weeks of wear, when switching from habitual silicone hydrogel (SiHy) daily wear. Method: A single-arm, open-label, bilateral dispensing study was conducted in 39 habitual spherical SiHy wearers (14 hyperopes; 25 myopes). Clinical visits occurred with habitual SiHy (control) at baseline and after 4 weeks of etMF DD open-eye lens wear at exit. Objective limbal/bulbar hyperemia using the Oculus K5M (0-4) and subjective grading of lid wiper epitheliopathy (LWE) (0-4) were tested for non-inferiority (NI), using a margin of 1 grade. Corneal thickness along a 10 mm cord was measured using the Visante OCT and tested for NI using a 30 µm margin. Corneal staining area was graded (0-100%). Results: The least-square mean differences (LSMD) and 95% confidence interval (95% CI) between etMF DD and habitual SiHy in central and peripheral corneal thickness (µm) were 3.64 (-2.0, 9.29) and 3.0 (-7.72, 13.72) in hyperopic, and 3.56 (-0.66, 7.78) and 6.40 (-1.62, 14.42) in myopic subjects. The LSMD (95% CI) for bulbar and limbal hyperemia were -0.08 (-0.19, 0.02) and -0.01 (-0.12, 0.09) in hyperopes, and 0.04 (-0.03, 0.12) and 0.04 (-0.04, 0.11) in myopes. The LSMD (95% CI) for LWE were 0.11 (-0.39, 0.60) and 0.30 (-0.07, 0.67) for hyperopes and myopes, respectively. Conclusions: No clinically significant differences in a variety of physiological responses were found when habitual reusable SiHy daily wear subjects were refitted into hydrogel etMF, when the subjects were followed for 4 weeks.

14.
Clin Ophthalmol ; 12: 695-700, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29692601

RESUMEN

PURPOSE: To evaluate tear osmolarity after using a hydroxypropyl-guar (HP-guar)-based lubricating eye drop four times daily (QID) for 3 weeks. METHODS: Thirty-one participants with dry eye disease (Ocular Surface Disease Index [OSDI] score ≥20 and tear osmolarity ≥300 mOsm/L in at least one eye) were enrolled in this prospective, dispensing, non-randomized study involving a baseline visit and 3-week follow-up. Tear osmolarity, non-invasive tear break up time (NITBUT), conjunctival hyperemia, corneal and conjunctival staining were determined at baseline. Participants were instructed to instill one drop of a HP-guar-based drop QID in each eye for 3 weeks. At the follow-up visit, the symptoms and ocular surface parameters were reassessed. At this visit, one HP-guar drop was instilled into each eye and osmolarity was measured after 15 minutes, to examine short-term changes in osmolarity. RESULTS: Twenty-eight participants completed the study (5M, 23F; median age 54 yrs, range 25-83 yrs). At baseline, mean OSDI score was 44.9±15.2 and mean osmolarities were 314.63±11.9/306.6±10.1 mOsm/L (worst eye [WE]/better eye [BE]). After 3 weeks, mean osmolarity reduced to 307.7±15.7/303.9±11.3 mOsm/L (WE/BE; p<0.05 and p=0.228, respectively) and mean OSDI scores reduced to 28.3±17.0 (p<0.01). A significant reduction in osmolarity was observed 15 minutes after instilling the lubricating drop (p<0.05 WE, p=0.09 BE). Significant improvements in central corneal staining (p<0.05 OU) and NITBUT (p<0.05 WE only) were observed. Reductions in conjunctival staining and hyperemia were observed, but were not significant (p>0.05). CONCLUSIONS: A significant reduction in tear osmolarity and improvements in dry eye symptoms, corneal staining, and NITBUT were observed after 3 weeks of QID use of a HP-guar-based lubricant drop. A decrease in osmolarity was also demonstrated 15 minutes after drop instillation.

15.
Eye Contact Lens ; 42(4): 211-20, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26398576

RESUMEN

Despite the fact that cosmetic products undergo rigorous testing to ensure they are safe for human use, some users report mild discomfort following their application. The cutaneous changes, such as allergic dermatitis, are well reported, but the ocular changes associated with eye cosmetic use are less so. Some pigmented cosmetic products may accumulate within the lacrimal system and conjunctivae over many years of use, but immediate reports of eye discomfort after application are most common. Changes to the tear film and its stability may occur shortly after application, and contact lens wearers can also be affected by lens spoliation from cosmetic products. Additionally, creams used in the prevention of skin aging are often applied around the eyes, and retinoids present in these formulations can have negative effects on meibomian gland function and may be a contributing factor to dry eye disease. The aim of this review is to summarize current knowledge regarding the impact of cosmetic products on the eye, ocular surface, and tear film.


Asunto(s)
Cosméticos/efectos adversos , Ojo/efectos de los fármacos , Ojo/microbiología , Ojo/patología , Ojo/fisiopatología , Alérgenos/efectos adversos , Animales , Antioxidantes/efectos adversos , Bimatoprost/efectos adversos , Blefaritis/etiología , Blefaritis/patología , Blefaritis/fisiopatología , Conjuntiva/microbiología , Conjuntiva/patología , Conjuntiva/fisiopatología , Enfermedades de la Conjuntiva/etiología , Lentes de Contacto , Contraindicaciones , Cosméticos/farmacología , Cosméticos/toxicidad , Síndromes de Ojo Seco/etiología , Síndromes de Ojo Seco/fisiopatología , Infecciones del Ojo/etiología , Infecciones del Ojo/microbiología , Humanos , Aparato Lagrimal/patología , Aparato Lagrimal/fisiopatología , Glándulas Tarsales/efectos de los fármacos , Glándulas Tarsales/fisiopatología , Ácaros/microbiología , Retinoides/efectos adversos , Piel/microbiología , Piel/fisiopatología , Tensoactivos/efectos adversos , Lágrimas/fisiología
16.
Eye Contact Lens ; 41(5): 304-9, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25738987

RESUMEN

PURPOSE: To examine, record, and quantify the migration of a conventional eye cosmetic pencil when applied to periocular skin in two different locations: behind the lash line (ELI) and along the periocular skin (ELO). METHODS: This was a pilot study (prospective, randomized crossover design) involving two visits on separate days. Three female subjects were randomly assigned one of two eyeliner application conditions: ELI (inside the lash line) or ELO (anterior to the lash line). Pencil eyeliner ("Glimmerstick" in Graphite; Avon, Northampton, United Kingdom) was applied to the subject's upper and lower right eyelid by the examiner. Slitlamp video recording of glitter particles suspended within the tear film was conducted for 30 sec on 10 occasions up to 2 hr post-eyeliner application. The number of glitter particles suspended in the tear film, analyzed using ImageJ software, is reported. RESULTS: The migration of the glitter particles occurred more readily in ELI application, with maximum contamination of the tear film achieved 5 to 10 min post-application. The migration of eyeliner following ELO application was comparatively slower and reduced compared with ELI application. The quantity of glitter particles suspended in the tear film varied between subjects; however, 2 hr post-application, contamination of the tear film from pencil eyeliner was negligible. CONCLUSIONS: Pencil eyeliner migrates most readily and maximally contaminates the tear film when applied posterior to the lash line. This has implications for contact lens wearers and patients with dry eye syndrome or sensitive eyes. Eye cosmetic usage for participants involved in anterior eye and contact lens research should be carefully considered in the design of studies.


Asunto(s)
Cosméticos/análisis , Lágrimas/química , Adulto , Cosméticos/farmacocinética , Estudios Cruzados , Síndromes de Ojo Seco/etiología , Femenino , Humanos , Proyectos Piloto , Estudios Prospectivos , Distribución Aleatoria , Factores de Tiempo
17.
Ophthalmic Physiol Opt ; 32(6): 501-7, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23057565

RESUMEN

PURPOSE: Eye cosmetics usage is commonplace and whilst some products such as eyeliner are applied with close proximity to the ocular surface, there is little knowledge of the short- and long-term ocular effects of eye cosmetic formulations. This study aimed to investigate the use of eye cosmetics and identify any relationships between ocular comfort and cosmetic usage. METHODS: Results were collated from an online survey comprising 23 questions that recorded demographics, Ocular Surface Disease Index (OSDI) score, extent and range of eye cosmetic use and perceived comfort differences with and without eye cosmetics. RESULTS: The 1360 female respondents (median age 25, interquartile range 20-34 years) completed the survey; 83% reported using eye cosmetics regularly (≥ 3 times per week) with mascara being most commonly used. Fifty three per cent used at least three different eye cosmetics products regularly. OSDI scores of cosmetics users were similar to non-users (p = 0.083), but perceived comfort was greater when cosmetics were not used (p < 0.001). In occasional cosmetics users (use of products < 3 times per week), 65% reported a reduction in comfort when cosmetics were used. Median OSDI scores suggested a trend towards reduced comfort amongst eyeliner users (p = 0.07) although frequency and type of cosmetic products used did not appear to influence OSDI scores. CONCLUSIONS: This study shows the use of multiple eye cosmetics is extensive and associated with the perception of ocular discomfort. With such widespread use of these products, more research is required to assess the effect on the ocular surface and tear film, which may be underestimated.


Asunto(s)
Cosméticos , Ojo , Adulto , Comportamiento del Consumidor , Cosméticos/administración & dosificación , Cosméticos/efectos adversos , Síndromes de Ojo Seco/inducido químicamente , Síndromes de Ojo Seco/psicología , Femenino , Humanos , Percepción , Lágrimas/efectos de los fármacos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA