Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-30377546

RESUMEN

OBJECTIVE: The purpose of this survey was to estimate the prevalence of viral load (VL) suppression and emergence of HIV drug resistance (HIVDR) among individuals receiving antiretroviral therapy (ART) for 36 months or longer in Viet Nam using a nationally representative sampling method. METHODS: The survey was conducted between May and August 2014 using a two-stage cluster design. Sixteen ART clinics were selected using probability proportional to proxy size sampling, and patients receiving ART for at least 36 months were consecutively enrolled. Epidemiological information and blood specimens were collected for HIV-1 VL and HIVDR testing; HIVDR was defined by the Stanford University HIVDR algorithm. RESULTS: Overall, 365 eligible individuals were recruited with a mean age of 38.2 years; 68.4% were men. The mean time on ART was 75.5 months (95% confidence interval [CI]: 69.0-81.9 months), and 93.7% of the patients were receiving non-nucleoside reverse transcriptase inhibitor-based regimens. Of the 365 individuals, 345 (94.7%, 95% CI: 64.1-99.4%) had VL below 1000 copies/mL and 19 (4.6%, 95% CI: 2.8--7.5) had HIVDR mutations. DISCUSSION: Our nationally representative survey found a high level of VL suppression and a low prevalence of HIVDR among individuals who received ART for at least 36 months in Viet Nam. Continued surveillance for HIVDR is important for evaluating and improving HIV programs.


Asunto(s)
Antirretrovirales/uso terapéutico , Farmacorresistencia Viral , Infecciones por VIH/tratamiento farmacológico , Carga Viral/estadística & datos numéricos , Adulto , Femenino , Humanos , Masculino , Encuestas y Cuestionarios , Factores de Tiempo , Resultado del Tratamiento , Vietnam
2.
Cardiovasc Revasc Med ; 19(3 Pt A): 273-278, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-28918876

RESUMEN

BACKGROUND/PURPOSE: Multiple BRSs and specifically the Absorb scaffold (BVS) (Abbott Vascular, Santa Clara, CA USA) have been often used to treat long diffuse coronary artery lesions. We evaluate by a computational fluid dynamic(CFD) study the impact on the intravascular fluid rheology on multiple bioabsorbable scaffolds (BRS) by standard overlapping versus edge-to-edge technique. METHODS/MATERIALS: We simulated the treatment of a real long significant coronary lesion (>70% luminal narrowing) involving the left anterior descending artery (LAD) treated with a standard or edge-to-edge technique, respectively. Simulations were performed after BVS implantations in two different conditions: 1) Edge-to-edge technique, where the scaffolds are kissed but not overlapped resulting in a luminal encroachment of 0.015cm (150µm); 2) Standard overlapping, where the scaffolds are overlapped resulting in a luminal encroachment of 0.030cm (300µm). After positioning the BVS across the long lesion, the implantation procedure was performed in-silico following all the usual procedural steps. RESULTS: Analysis of the wall shear stress (WSS) suggested that at the vessel wall level the WSS were lower in the overlapping zones overlapping compared to the edge-to-edge zone (∆=0.061Pa, p=0.01). At the struts level the difference between the two WSS was more striking (∆=1.065e-004 p=0.01) favouring the edge-to-edge zone. CONCLUSIONS: Our study suggested that at both vessel wall and scaffold struts levels, there was lowering WSS when multiple BVS were implanted with the standard overlapping technique compared to the "edge-to-edge" technique. This lower WSS might represent a substrate for restenosis, early and late BVS thrombosis, potentially explaining at least in part the recent evidences of devices poor performance.


Asunto(s)
Implantes Absorbibles , Simulación por Computador , Enfermedad de la Arteria Coronaria/cirugía , Reestenosis Coronaria/etiología , Estenosis Coronaria/cirugía , Trombosis Coronaria/etiología , Modelos Cardiovasculares , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Stents , Velocidad del Flujo Sanguíneo , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Circulación Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/fisiopatología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/fisiopatología , Trombosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/fisiopatología , Humanos , Diseño de Prótesis , Reología , Factores de Riesgo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...