Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
Water Res ; 253: 121300, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38367385

RESUMEN

Landfills are the primary endpoint for the disposal of PFAS-laden waste, which subsequently releases PFAS to the surrounding environments through landfill leachate. Ozone foam fractionation emerges as a promising technology for PFAS removal to address the issue. This study aims to (i) assess the effectiveness of the ozone foam fractionation system to remove PFAS from landfill leachate, and (ii) quantify equilibrium PFAS adsorption onto the gas-water interface of ozone bubbles, followed by a comparison with air foam fractionation. The results show that ozone foam fractionation is effective for PFAS removal from landfill leachate, with more than 90 % long-chain PFAS removed. The identified operating conditions provide valuable insights for industrial applications, guiding the optimization of ozone flow rates (1 L/min), dosing (43 mg/L) and minimizing foamate production (4 % wettability). The equilibrium modelling reveals that the surface excess of air bubbles exceeds that of ozone bubbles by 20-40 % at a corresponding PFAS concentration. However, the overall removal of PFAS from landfill leachate by ozone foam fractionation remains substantial. Notably, ozone foam fractionation generates foamate volumes 2 - 4 times less, resulting in significant cost savings for the final disposal of waste products and reduced site storage requirements.


Asunto(s)
Fluorocarburos , Ozono , Eliminación de Residuos , Contaminantes Químicos del Agua , Eliminación de Residuos/métodos , Contaminantes Químicos del Agua/análisis , Adsorción , Instalaciones de Eliminación de Residuos
2.
J Hazard Mater ; 466: 133471, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38266587

RESUMEN

This review provides a comprehensive overview of the occurrence, fate, treatment and multi-criteria analysis of microplastics (MPs) and organic contaminants (OCs) in biosolids. A meta-analysis was complementarily analysed through the literature to map out the occurrence and fate of MPs and 10 different groups of OCs. The data demonstrate that MPs (54.7% occurrence rate) and linear alkylbenzene sulfonate surfactants (44.2% occurrence rate) account for the highest prevalence of contaminants in biosolids. In turn, dioxin, polychlorinated biphenyls (PCBs) and phosphorus flame retardants (PFRs) have the lowest rates (<0.01%). The occurrence of several OCs (e.g., dioxin, per- and polyfluoroalkyl substances, polycyclic aromatic hydrocarbons, pharmaceutical and personal care products, ultraviolet filters, phosphate flame retardants) in Europe appear at higher rates than in Asia and the Americas. However, MP concentrations in biosolids from Australia are reported to be 10 times higher than in America and Europe, which required more measurement data for in-depth analysis. Amongst the OC groups, brominated flame retardants exhibited exceptional sorption to biosolids with partitioning coefficients (log Kd) higher than 4. To remove these contaminants from biosolids, a wide range of technologies have been developed. Our multicriteria analysis shows that anaerobic digestion is the most mature and practical. Thermal treatment is a viable option; however, it still requires additional improvements in infrastructure, legislation, and public acceptance.


Asunto(s)
Dioxinas , Retardadores de Llama , Microplásticos , Plásticos , Biosólidos , Retardadores de Llama/análisis
3.
Water Res X ; 20: 100195, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37637861

RESUMEN

Per- and polyfluoroalkyl substances (PFAS) within concrete pads impacted by historical firefighting training using aqueous film-forming foam (AFFF) may be potential secondary sources of PFAS due to surficial leaching. This study aimed to (i) characterize the effectiveness of two commercially available sealants (Product A and Product B) in mitigating leaching of five PFAS (e.g., PFOS, PFOA, PFHxS, PFHxA, 6:2 FTS) from concrete surfaces at the laboratory-scale, and (ii) develop a model to forecast cumulative leaching of the same five PFAS over 20 years from sealed and unsealed concrete surfaces. Laboratory trials demonstrated that both sealants reduced the surficial leaching of the five PFAS studied, and Product B demonstrated a comparatively greater reduction in surface leaching than Product A as measured against unsealed controls. The cumulative PFOS leaching from an unsealed concrete surface is estimated by the model to be about 400 mg/m2 over 20 years and reached asymptotic conditions after 15 years. In contrast, the model output suggests asymptotic conditions were not achieved within the modeled time of 20 years after sealing with Product A and 85% of PFOS was predicted to have leached (∼340 mg/m2). Negligible leaching of PFOS after sealing with Product B was observed ( < 5 × 10-9 mg/m2). Results from modeled rainfall scenarios suggest PFAS leachability is reduced from sealed versus unsealed AFFF-impacted concrete surfaces.

4.
Chemosphere ; 314: 137702, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36587913

RESUMEN

This study aims to investigate the spatiotemporal trends and impact of COVID-19 lockdowns to the profile of physiochemical parameters in the influent of wastewater treatment plants (WWTPs) around Brisbane, Australia. One 24-hr composite influent sample was collected from 10 WWTPs and analyzed for a range of physiochemical parameters per week (i.e., chemical oxygen demand (COD), total organic carbon (TOC), total nitrogen (TN), total phosphorus (TP), ammonia, volatile suspended solid (VSS)) and per month (i.e., Ni and Cr) from 2012 to 2020, including the period of COVID-19 lockdowns in the region. The catchments studied were urban, with a mix of domestic and industrial activities contributing towards the contaminant profile. Statistical analysis identified that industrial and commercial land use, as well as population size had a large impact to the parameter loads and profile. Per capita mass loads of Cr in one catchment were 100 times higher than in others from one industrial point source. TP demonstrated a potential monotonic decrease over time due to practical reduction policies that have been implemented for phosphorous content in household detergents, except for one catchment where trade waste from food manufacturing industries contributed to an overall increase of 6.9%/year TP. The COVID-19 lockdown (March-April 2020) posed different impact on different catchments, either decrease (7-61%) or increase (2-40%) of most parameter loads (e.g., COD, TOC, TN, TP, VSS, Ammonia), which was likely driven by catchment characteristics (i.e., the proportion of residential, commercial, and industrial land uses). This study enhances our understanding of spatiotemporal trend of contaminants in the catchments for further effective source control.


Asunto(s)
COVID-19 , Aguas del Alcantarillado , Humanos , Amoníaco/análisis , COVID-19/epidemiología , Control de Enfermedades Transmisibles , Australia , Nitrógeno/análisis , Fósforo/análisis , Eliminación de Residuos Líquidos
5.
Sci Total Environ ; 870: 161749, 2023 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-36690112

RESUMEN

Human biomonitoring programs of per- and polyfluoroalkyl substances (PFAS) have been conducted around the world to assess human exposure and health risk. Inquiry into population PFAS levels in a socioeconomically and geographically unique region such as the Pacific Island Papua New Guinea, may provide new insights into PFAS exposure pathways and sources. This study presented the first indication of PFAS exposure in the Papua New Guinea population. De-identified serum samples were pooled from surplus pathology serum samples collected between 2019 and 2020. A total of 11 PFAS were detected in the serum pools including 10 perfluoroalkyl acids (PFAA) and 9Cl-F53B (a perfluorooctane sulfonic acid - PFOS alternative). The observed PFAA profile was somewhat similar to that observed for general population data of other countries such as Australia, Malaysia, and Canada suggesting similar exposure sources and/or pathways. However, PFAS concentrations were consistently lower than concentrations in the serum measured in pools obtained from Australia. The detection of 9Cl-F53B in all pools was a new finding which might be related to exposure from locally industrial sources.


Asunto(s)
Ácidos Alcanesulfónicos , Contaminantes Ambientales , Fluorocarburos , Humanos , Papúa Nueva Guinea , Ácidos Alcanesulfónicos/análisis , Monitoreo Biológico , Fluorocarburos/análisis , Australia , Canadá
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA