Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Vox Sang ; 119(4): 368-376, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38286764

RESUMEN

BACKGROUND AND OBJECTIVES: Red blood cell (RBC) transfusions pose a risk of alloantibody development in patients. For patients with increased alloimmunization risk, extended preventive matching is advised, encompassing not only the ABO-D blood groups but also the most clinically relevant minor antigens: C, c, E, e, K, Fya, Fyb, Jka, Jkb, S and s. This study incorporates patient-specific data and the clinical consequences of mismatching into the allocation process. MATERIALS AND METHODS: We have redefined the MINimize Relative Alloimmunization Risks (MINRAR) model to include patient group preferences in selecting RBC units from a finite supply. A linear optimization approach was employed, considering both antigen immunogenicity and the clinical impact of mismatches for specific patient groups. We also explore the advantages of informing the blood bank about scheduled transfusions, allowing for a more strategic blood distribution. The model is evaluated using historical data from two Dutch hospitals, measuring shortages and minor antigen mismatches. RESULTS: The updated model, emphasizing patient group-specific considerations, achieves a similar number of mismatches as the original, yet shifts mismatches among patient groups and antigens, reducing expected alloimmunization consequences. Simultaneous matching for multiple hospitals at the distribution centre level, considering scheduled demands, led to a 30% decrease in mismatches and a 92% reduction in shortages. CONCLUSION: The reduction of expected alloimmunization consequences by incorporating patient group preferences demonstrates our strategy's effectiveness for patient health. Substantial reductions in mismatches and shortages with multi-hospital collaboration highlights the importance of sharing information in the blood supply chain.


Asunto(s)
Antígenos de Grupos Sanguíneos , Eritrocitos , Humanos , Transfusión Sanguínea , Transfusión de Eritrocitos , Incompatibilidad de Grupos Sanguíneos/prevención & control , Tipificación y Pruebas Cruzadas Sanguíneas , Isoanticuerpos , Sistema del Grupo Sanguíneo ABO
2.
J Thromb Haemost ; 22(4): 1236-1248, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38128762

RESUMEN

Calibration of prothrombin time (PT) in terms of international normalized ratio (INR) has been outlined in "Guidelines for thromboplastins and plasmas used to control oral anticoagulant therapy" (World Health Organization, 2013). The international standard ISO 17511:2020 presents requirements for manufacturers of in vitro diagnostic (IVD) medical devices (MDs) for documenting the calibration hierarchy for a measured quantity in human samples using a specified IVD MD. The objective of this article is to define an unequivocal, metrologically traceable calibration hierarchy for the INR measured in plasma as well as in whole blood samples. Calibration of PT and INR for IVD MDs according to World Health Organization guidelines is similar to that in cases where there is a reference measurement procedure that defines the measurand for value assignment as described in ISO 17511:2020. We conclude that, for PT/INR standardization, the optimal calibration hierarchy includes a primary process to prepare an international reference reagent and measurement procedure that defines the measurand by a value assignment protocol conforming to clause 5.3 of ISO 17511:2020. A panel of freshly prepared human plasma samples from healthy adult individuals and patients on vitamin K antagonists is used as a commutable secondary calibrator as described in ISO 17511:2020. A sustainable metrologically traceable calibration hierarchy for INR should be based on an international protocol for value assignment with a single primary reference thromboplastin and the harmonized manual tilt tube technique for clotting time determination. The primary international reference thromboplastin reagent should be used only for calibration of successive batches of the secondary reference thromboplastin reagent.


Asunto(s)
Química Clínica , Tromboplastina , Adulto , Humanos , Tiempo de Protrombina , Relación Normalizada Internacional , Calibración , Anticoagulantes/uso terapéutico , Estándares de Referencia , Fibrinolíticos/uso terapéutico , Indicadores y Reactivos , Comunicación , Vitamina K
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...