RESUMEN
Programmed death-ligand 1 (PD-L1) drives inhibition of antigen-specific T cell responses through engagement of its receptor programmed death-1 (PD-1) on activated T cells. Overexpression of these immune checkpoint proteins in the tumor microenvironment has motivated the design of targeted antibodies that disrupt this interaction. Despite clinical success of these antibodies, response rates remain low, necessitating novel approaches to enhance performance. Here, we report the development of antibody fusion proteins that block immune checkpoint pathways through a distinct mechanism targeting molecular trafficking. By engaging multiple receptor epitopes on PD-L1, our engineered multiparatopic antibodies induce rapid clustering, internalization, and degradation in an epitope- and topology-dependent manner. The complementary mechanisms of ligand blockade and receptor downregulation led to more durable immune cell activation and dramatically reduced PD-L1 availability in mouse tumors. Collectively, these multiparatopic antibodies offer mechanistic insight into immune checkpoint protein trafficking and how it may be manipulated to reprogram immune outcomes.
Asunto(s)
Antígeno B7-H1 , Regulación hacia Abajo , Antígeno B7-H1/metabolismo , Antígeno B7-H1/inmunología , Antígeno B7-H1/antagonistas & inhibidores , Animales , Ratones , Humanos , Regulación hacia Abajo/efectos de los fármacos , Ratones Endogámicos C57BL , Femenino , Línea Celular Tumoral , Microambiente Tumoral/inmunología , Microambiente Tumoral/efectos de los fármacosRESUMEN
The limited availability of molecularly targeted low-molecular-weight imaging agents for monitoring multiple myeloma (MM)-targeted therapies has been a significant challenge in the field. In response, a first-in-class peptide-based radiotracer, [68Ga]Ga-AJ206, is developed that can be seamlessly integrated into the standard clinical workflow and is specifically designed to noninvasively quantify CD38 levels and pharmacodynamics by positron emission tomography (PET). A bicyclic peptide, AJ206, is synthesized and exhibits high affinity to CD38 (KD: 19.1 ± 0.99 × 10-9 m) by surface plasmon resonance. Further, [68Ga]Ga-AJ206-PET shows high contrast within 60 min and suitable absorbed dose estimates for clinical use. Additionally, [68Ga]Ga-AJ206 detects CD38 expression in cell line-derived xenografts, patient-derived xenografts (PDXs), and disseminated disease models in a manner consistent with flow cytometry and immunohistochemistry findings. Moreover, [68Ga]Ga-AJ206-PET successfully quantifies CD38 pharmacodynamics in PDXs, revealing increased CD38 expression in the tumor following all-trans retinoic acid (ATRA) therapy. In conclusion, [68Ga]Ga-AJ206 exhibits the salient features required for clinical translation, providing CD38-specific high-contrast images in multiple models of MM. [68Ga]Ga-AJ206-PET could be useful for quantifying total CD38 levels and pharmacodynamics during therapy to evaluate approved and new therapies in MM and other diseases with CD38 involvement.
Asunto(s)
ADP-Ribosil Ciclasa 1 , Radioisótopos de Galio , Mieloma Múltiple , Tomografía de Emisión de Positrones , Mieloma Múltiple/tratamiento farmacológico , Mieloma Múltiple/metabolismo , Mieloma Múltiple/diagnóstico por imagen , Animales , ADP-Ribosil Ciclasa 1/metabolismo , Ratones , Humanos , Tomografía de Emisión de Positrones/métodos , Radiofármacos/farmacocinética , Modelos Animales de Enfermedad , Péptidos/metabolismo , Glicoproteínas de Membrana/metabolismo , Línea Celular TumoralRESUMEN
Renal cell carcinoma (RCC) and urothelial carcinoma (UC) are two of the most common genitourinary malignancies. 2-deoxy-2-[18F]fluoro-d-glucose (18F-FDG) can play an important role in the evaluation of patients with RCC and UC. In addition to the clinical utility of 18F-FDG PET to evaluate for metastatic RCC or UC, the shift in molecular imaging to focus on specific ligand-receptor interactions should provide novel diagnostic and therapeutic opportunities in genitourinary malignancies. In combination with the rise of artificial intelligence, our ability to derive imaging biomarkers that are associated with treatment selection, response assessment, and overall patient prognostication will only improve.
Asunto(s)
Carcinoma de Células Renales , Carcinoma de Células Transicionales , Neoplasias Renales , Neoplasias de la Vejiga Urinaria , Neoplasias Urológicas , Humanos , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/secundario , Fluorodesoxiglucosa F18 , Carcinoma de Células Transicionales/diagnóstico por imagen , Inteligencia Artificial , Neoplasias de la Vejiga Urinaria/terapia , Riñón , Neoplasias Urológicas/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Tomografía de Emisión de Positrones/métodos , Neoplasias Renales/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de PositronesRESUMEN
High baseline clearance of immune checkpoint inhibitors (ICIs), independent of dose or systemic exposure, is associated with cachexia and poor outcomes in cancer patients. Mechanisms linking ICI clearance, cachexia and ICI therapy failure are unknown. Here, we evaluate in four murine models and across multiple antibodies whether altered baseline catabolic clearance of administered antibody requires a tumor and/or cachexia and whether medical reversal of cachexia phenotype can alleviate altered clearance. Key findings include mild cachexia phenotype and lack of elevated pembrolizumab clearance in the MC38 tumor-bearing model. We also observed severe cachexia and decreased, instead of increased, baseline pembrolizumab clearance in the tumor-free cisplatin-induced cachexia model. Liver Fcgrt expression correlated with altered baseline catabolic clearance, though elevated clearance was still observed with antibodies having no (human IgA) or reduced (human H310Q IgG1) FcRn binding. We conclude cachexia phenotype coincides with altered antibody clearance, though tumor presence is neither sufficient nor necessary for altered clearance in immunocompetent mice. Magnitude and direction of clearance alteration correlated with hepatic Fcgrt, suggesting changes in FcRn expression and/or recycling function may be partially responsible, though factors beyond FcRn also contribute to altered clearance in cachexia.
Asunto(s)
Inhibidores de Puntos de Control Inmunológico , Neoplasias , Humanos , Animales , Ratones , Inhibidores de Puntos de Control Inmunológico/uso terapéutico , Caquexia/tratamiento farmacológico , Caquexia/etiología , Caquexia/metabolismo , Neoplasias/complicaciones , Neoplasias/tratamiento farmacológico , Neoplasias/metabolismo , Hígado/metabolismo , Inmunoglobulina G/metabolismoRESUMEN
BACKGROUND: Combination therapies that aim to improve the clinical efficacy to immune checkpoint inhibitors have led to the need for non-invasive and early pharmacodynamic biomarkers. Positron emission tomography (PET) is a promising non-invasive approach to monitoring target dynamics, and programmed death-ligand 1 (PD-L1) expression is a central component in cancer immunotherapy strategies. [18F]DK222, a peptide-based PD-L1 imaging agent, was investigated in this study using humanized mouse models to explore the relationship between PD-L1 expression and therapy-induced changes in cancer. METHODS: Cell lines and xenografts derived from three non-small cell lung cancers (NSCLCs) and three urothelial carcinomas (UCs) were used to validate the specificity of [18F]DK222 for PD-L1. PET was used to quantify anti-programmed cell death protein-1 (PD-1) therapy-induced changes in PD-L1 expression in tumors with and without microsatellite instability (MSI) in humanized mice. Furthermore, [18F]DK222-PET was used to validate PD-L1 pharmacodynamics in the context of monotherapy and combination immunotherapy in humanized mice bearing A375 melanoma xenografts. PET measures of PD-L1 expression were used to establish a relationship between pathological and immunological changes. Lastly, spatial distribution analysis of [18F]DK222-PET was developed to assess the effects of different immunotherapy regimens on tumor heterogeneity. RESULTS: [18F]DK222-PET and biodistribution studies in mice with NSCLC and UC xenografts revealed high but variable tumor uptake at 60 min that correlated with PD-L1 expression. In MSI tumors treated with anti-PD-1, [18F]DK222 uptake was higher than in control tumors. Moreover, [18F]DK222 uptake was higher in A375 tumors treated with combination therapy compared with monotherapy, and negatively correlated with final tumor volumes. In addition, a higher number of PD-L1+ cells and higher CD8+-to-CD4+ cell ratio was observed with combination therapy compared with monotherapy, and positively correlated with PET. Furthermore, spatial distribution analysis showed higher [18F]DK222 uptake towards the core of the tumors in combination therapy, indicating a more robust and distinct pattern of immune cell infiltration. CONCLUSION: [18F]DK222-PET has potential as a non-invasive tool for monitoring the effects of immunotherapy on tumors. It was able to detect variable PD-L1 expression in tumors of different cancer types and quantify therapy-induced changes in tumors. Moreover, [18F]DK222-PET was able to differentiate the impact of different therapies on tumors.
Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Animales , Ratones , Antígeno B7-H1 , Distribución Tisular , Tomografía de Emisión de Positrones/métodos , Inmunoterapia/métodosRESUMEN
Purpose To examine the association between hypoxia and programmed cell death ligand 1 (PD-L1) expression using bioluminescence imaging (BLI) and PET/MRI in a syngeneic mouse model of triple-negative breast cancer (TNBC). Materials and Methods PET/MRI and optical imaging were used to determine the role of hypoxia in altering PD-L1 expression using a syngeneic TNBC model engineered to express luciferase under hypoxia. Results Imaging showed a close spatial association between areas of hypoxia and increased PD-L1 expression in the syngeneic murine (4T1) tumor model. Mouse and human TNBC cells exposed to hypoxia exhibited a significant increase in PD-L1 expression, consistent with the in vivo imaging data. The role of hypoxia in increasing PD-L1 expression was further confirmed by using The Cancer Genome Atlas analyses of different human TNBCs. Conclusion These results have identified the potential role of hypoxia in contributing to PD-L1 heterogeneity in tumors by increasing cancer cell PD-L1 expression. Keywords: Hypoxia, PD-L1, Triple-Negative Breast Cancer, PET/MRI, Bioluminescence Imaging Supplemental material is available for this article. © RSNA, 2023.
Asunto(s)
Neoplasias de la Mama Triple Negativas , Humanos , Animales , Ratones , Neoplasias de la Mama Triple Negativas/diagnóstico por imagen , Neoplasias de la Mama Triple Negativas/genética , Antígeno B7-H1/genética , Ligandos , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Hipoxia , ApoptosisRESUMEN
BACKGROUND: Chimeric antigen receptor (CAR) T cell therapy is an exciting cell-based cancer immunotherapy. Unfortunately, CAR-T cell therapy is associated with serious toxicities such as cytokine release syndrome (CRS) and neurotoxicity. The mechanism of these serious adverse events (SAEs) and how homing, distribution and retention of CAR-T cells contribute to toxicities is not fully understood. Enabling in vitro methods to allow meaningful, sensitive in vivo biodistribution studies is needed to better understand CAR-T cell disposition and its relationship to both effectiveness and safety of these products. METHODS: To determine if radiolabelling of CAR-T cells could support positron emission tomography (PET)-based biodistribution studies, we labeled IL-13Rα2 targeting scFv-IL-13Rα2-CAR-T cells (CAR-T cells) with 89Zirconium-oxine (89Zr-oxine) and characterized and compared their product attributes with non-labeled CAR-T cells. The 89Zr-oxine labeling conditions were optimized for incubation time, temperature, and use of serum for labeling. In addition, T cell subtype characterization and product attributes of radiolabeled CAR-T cells were studied to assess their overall quality including cell viability, proliferation, phenotype markers of T-cell activation and exhaustion, cytolytic activity and release of interferon-γ upon co-culture with IL-13Rα2 expressing glioma cells. RESULTS: We observed that radiolabeling of CAR-T cells with 89Zr-oxine is quick, efficient, and radioactivity is retained in the cells for at least 8 days with minimal loss. Also, viability of radiolabeled CAR-T cells and subtypes such as CD4 + , CD8 + and scFV-IL-13Rα2 transgene positive T cell population were characterized and found similar to that of unlabeled cells as determined by TUNEL assay, caspase 3/7 enzyme and granzyme B activity assay. Moreover, there were no significant changes in T cell activation (CD24, CD44, CD69 and IFN-γ) or T cell exhaustion (PD-1, LAG-3 and TIM3) markers expression between radiolabeled and unlabeled CAR-T cells. In chemotaxis assays, migratory capability of radiolabeled CAR-T cells to IL-13Rα2Fc was similar to that of non-labeled cells. CONCLUSIONS: Importantly, radiolabeling has minimal impact on biological product attributes including potency of CAR-T cells towards IL-13Rα2 positive tumor cells but not IL-13Rα2 negative cells as measured by cytolytic activity and release of IFN-γ. Thus, IL-13Rα2 targeting CAR-T cells radiolabeled with 89Zr-oxine retain critical product attributes and suggest 89Zr-oxine radiolabeling of CAR-T cells may facilitate biodistribution and tissue trafficking studies in vivo using PET.
Asunto(s)
Inmunoterapia Adoptiva , Radioisótopos , Linfocitos T , Circonio , Circonio/farmacocinética , Radioisótopos/farmacocinética , Tomografía de Emisión de Positrones , Rastreo Celular/métodos , Anticuerpos de Cadena Única , Linfocitos T/citología , Distribución Tisular , Células Jurkat , Animales , Ratones , Proliferación Celular , Supervivencia CelularRESUMEN
PURPOSE: The limited availability of molecularly targeted low-molecular-weight imaging agents for monitoring multiple myeloma (MM)-targeted therapies has been a significant challenge in the field. In response, we developed [68Ga]Ga-AJ206, a peptide-based radiotracer that can be seamlessly integrated into the standard clinical workflow and is specifically designed to non-invasively quantify CD38 levels and pharmacodynamics by positron emission tomography (PET). EXPERIMENTAL DESIGN: We synthesized a high-affinity binder for quantification of CD38 levels. Affinity was tested using surface plasmon resonance, and In vitro specificity was evaluated using a gallium-68-labeled analog. Distribution, pharmacokinetics, and CD38 specificity of the radiotracer were assessed in MM cell lines and in primary patient-derived myeloma cells and xenografts (PDX) with cross-validation by flow cytometry and immunohistochemistry. Furthermore, we investigated the radiotracer's potential to quantify CD38 pharmacodynamics induced by all-trans retinoic acid therapy (ATRA). RESULTS: [68Ga]Ga-AJ206 exhibited high CD38 binding specificity (KD: 19.1±0.99 nM) and CD38-dependent In vitro binding. [68Ga]Ga-AJ206-PET showed high contrast within 60 minutes and suitable absorbed dose estimates for clinical use. Additionally, [68Ga]Ga-AJ206 detected CD38 expression in xenografts, PDXs and disseminated disease models in a manner consistent with flow cytometry and immunohistochemistry findings. Moreover, [68Ga]Ga-AJ206-PET successfully quantified CD38 pharmacodynamics in PDXs, revealing increased CD38 expression in the tumor following ATRA therapy. CONCLUSIONS: [68Ga]Ga-AJ206 exhibited the salient features required for clinical translation, providing CD38-specific high contrast images in multiple models of MM. [68Ga]Ga-AJ206-PET could be useful for quantifying total CD38 levels and pharmacodynamics during therapy to evaluate approved and new therapies in MM and other diseases with CD38 involvement.
RESUMEN
A radiochemical synthesis of [18 F]DK222, a peptide binder of programmed death ligand 1 protein, suitable for human PET studies is described, and results from validation productions are presented. The high specific activity radiotracer product is prepared as a sterile, apyrogenic solution that conforms to current Good Manufacturing Practice (cGMP) requirements. In addition, the production is extended to use a commercial synthesizer platform (General Electric FASTlab 2).
Asunto(s)
Antígeno B7-H1 , Tomografía de Emisión de Positrones , Humanos , Tomografía de Emisión de Positrones/métodos , Radioisótopos de Flúor , Radiofármacos , Radioquímica/métodosRESUMEN
PURPOSE: Immune checkpoint therapy (ICT) is currently ineffective in a majority of patients. Tumor drug exposure measurements can provide vital insights into mechanisms involved in the resistance of solid tumors to those therapeutics; however, tools to quantify in situ drug exposure are few. We have investigated the potential of programmed death-ligand 1 (PD-L1) pharmacodynamics, quantified using PET, to inform on the tumor exposure of anti-PD-L1 (aPD-L1) therapeutics. EXPERIMENTAL DESIGN: To noninvasively quantify PD-L1 levels, we first developed a novel peptide-based gallium-68-labeled binder, [68Ga]Ga-DK223, and evaluated its in vivo distribution, pharmacokinetics, and PD-L1 specificity in preclinical models of triple-negative breast cancer and urothelial carcinoma with variable PD-L1 expression. We then quantified baseline and accessible PD-L1 levels in tumors as a noninvasive pharmacodynamic measure to assess tumor exposure to two aPD-L1 antibodies (avelumab and durvalumab). RESULTS: DK223 exhibited a KD of 1.01±0.83 nmol/L for PD-L1 and inhibited the PD-1:PD-L1 interaction in a dose-dependent manner. [68Ga]Ga-DK223 provides high-contrast PET images within 60 minutes of administration and detects PD-L1 in an expression-dependent manner in xenograft models. PD-L1 pharmacodynamics measured using [68Ga]Ga-DK223-PET revealed that avelumab and durvalumab had similar exposure early during therapy, but only durvalumab exhibited sustained exposure at the tumor. CONCLUSIONS: [68Ga]Ga-DK223 detected variable PD-L1 levels and exhibited salient features required for clinical translation. [68Ga]Ga-DK223-PET could be useful for quantifying total PD-L1 levels at baseline and accessible PD-L1 levels during therapy to understand drug exposure at the tumor, thus supporting its use for guiding and optimizing ICT.
Asunto(s)
Carcinoma de Células Transicionales , Neoplasias de la Vejiga Urinaria , Humanos , Tomografía de Emisión de Positrones/métodos , Antígeno B7-H1/metabolismo , PéptidosRESUMEN
(1) Background: Despite advances in surgical approaches and drug development, ovarian cancer is still a leading cause of death from gynecological malignancies. Patients diagnosed with late-stage disease are treated with aggressive surgical resection and chemotherapy, but recurrence with resistant disease is often observed following treatment. There is a critical need for effective therapy for late-stage ovarian cancer. Photoimmunotherapy (PIT), using an antibody conjugated to a near infrared (NIR) dye, constitutes an effective theranostic strategy to detect and selectively eliminate targeted cell populations. (2) Methods: Here, we are targeting program death ligand 1 (PD-L1) using NIR-PIT in a syngeneic mouse model of ovarian cancer. PD-L1 PIT-mediated cytotoxicity was quantified in RAW264.7 macrophages and ID8-Defb29-VEGF cells in culture, and in vivo with orthotopic ID8-Defb29-VEGF tumors. (3) Results: Treatment efficacy was observed both in vitro and in vivo. (4) Conclusions: Our data highlight the need for further investigations to assess the potential of using NIR-PIT for ovarian cancer therapy to improve the treatment outcome of ovarian cancer.
RESUMEN
68Ga-NOTA-WL12 is a peptide-based PET imaging agent. We conducted a first-in-human study of 68Ga-NOTA-WL12 for PET to study the in vivo biodistribution, metabolism, radiation dosimetry, safety, and potential for quantifying programmed death ligand-1 (PD-L1) expression levels in patients with advanced non-small cell lung cancer (NSCLC). Methods: In vitro assessment of the PD-L1 expression and cellular uptake of 68Ga-NOTA-WL12 was performed, followed by in vivo evaluation of 68Ga-NOTA-WL12 uptake in mouse models with tumors. Nine patients with NSCLC with lesions expressing PD-L1 were enrolled and monitored for adverse events during the study. 68Ga-NOTA-WL12 and paired 18F-FDG PET/CT imaging were performed. Uptake (SUV, SUL [SUVlean], and kBq/mL) values of tumors and normal organs were obtained. Radiopharmaceutical biodistribution, radiation dosimetry, and the relationship of tumor uptake to PD-L1 expression were evaluated. Follow-up 18F-FDG PET/CT was performed in patients who had undergone treatment with a combination of pembrolizumab with chemotherapy. Results:68Ga-NOTA-WL12 exhibited PD-L1-specific uptake in vitro and in PD-L1-positive tumors in vivo. 68Ga-NOTA-WL12 PET imaging proved safe with acceptable radiation dosimetry. Physiologic tracer uptake was mainly visible in the liver, spleen, small intestine, and kidney. Tumors were clearly visible, particularly in the lungs, with a tumor-to-lung ratio of 4.45 ± 1.89 at 1 h. One hour was a suitable time point for image acquisition because no significant differences were noted in tumor-to-background ratios between 1 and 2 h. A strong, positive correlation was found between tumor uptake (SUVpeak) and PD-L1 immunohistochemistry results (r = 0.9349; P = 0.002). 68Ga-NOTA-WL12 and 18F-FDG PET studies suggest that PD-L1 PET before therapy may indicate the therapeutic efficacy of pembrolizumab plus chemotherapy combination treatment. Conclusion: Our first-in-human findings demonstrate the safety and feasibility of 68Ga-NOTA-WL12 for noninvasive, in vivo detection of tumor PD-L1 expression levels, indicating potential benefits for clinical PD-L1 therapy.
Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Animales , Antígeno B7-H1/metabolismo , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Ratones , Péptidos/metabolismo , Tomografía Computarizada por Tomografía de Emisión de Positrones , Distribución TisularRESUMEN
Macromolecules such as monoclonal antibodies (mAbs) are likely to experience poor tumor penetration because of their large size, and thus low drug exposure of target cells within a tumor could contribute to suboptimal responses. Given the challenge of inadequate quantitative tools to assess mAb activity within tumors, we hypothesized that measurement of accessible target levels in tumors could elucidate the pharmacologic activity of a mAb and could be used to compare the activity of different mAbs. Using positron emission tomography (PET), we measured the pharmacodynamics of immune checkpoint protein programmed-death ligand 1 (PD-L1) to evaluate pharmacologic effects of mAbs targeting PD-L1 and its receptor programmed cell death protein 1 (PD-1). For PD-L1 quantification, we first developed a small peptide-based fluorine-18-labeled PET imaging agent, [18F]DK222, which provided high-contrast images in preclinical models. We then quantified accessible PD-L1 levels in the tumor bed during treatment with anti-PD-1 and anti-PD-L1 mAbs. Applying mixed-effects models to these data, we found subtle differences in the pharmacodynamic effects of two anti-PD-1 mAbs (nivolumab and pembrolizumab). In contrast, we observed starkly divergent target engagement with anti-PD-L1 mAbs (atezolizumab, avelumab, and durvalumab) that were administered at equivalent doses, correlating with differential effects on tumor growth. Thus, we show that measuring PD-L1 pharmacodynamics informs mechanistic understanding of therapeutic mAbs targeting PD-L1 and PD-1. These findings demonstrate the value of quantifying target pharmacodynamics to elucidate the pharmacologic activity of mAbs, independent of mAb biophysical properties and inclusive of all physiological variables, which are highly heterogeneous within and across tumors and patients.
Asunto(s)
Antineoplásicos Inmunológicos/farmacología , Antígeno B7-H1/antagonistas & inhibidores , Neoplasias de la Mama/tratamiento farmacológico , Radioisótopos de Flúor/farmacocinética , Fragmentos de Péptidos/farmacocinética , Tomografía de Emisión de Positrones/métodos , Receptor de Muerte Celular Programada 1/antagonistas & inhibidores , Animales , Apoptosis , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/metabolismo , Neoplasias de la Mama/patología , Proliferación Celular , Femenino , Humanos , Ratones , Ratones Endogámicos NOD , Ratones SCID , Radiofármacos/farmacocinética , Células Tumorales Cultivadas , Ensayos Antitumor por Modelo de XenoinjertoRESUMEN
Fibroblast activation protein (FAP) has become a favored target for imaging and therapy of malignancy. We have synthesized and characterized two new (4-quinolinoyl)-glycyl-2-cyanopyrrolidine-based small molecules for imaging of FAP, QCP01 and [111In]QCP02, using optical and single-photon computed tomography/CT, respectively. Binding of imaging agents to FAP was assessed in six human cancer cell lines of different cancer types: glioblastoma (U87), melanoma (SKMEL24), prostate (PC3), NSCLC (NCIH2228), colorectal carcinoma (HCT116), and lung squamous cell carcinoma (NCIH226). Mouse xenograft models were developed with FAP-positive U87 and FAP-negative PC3 cells to test pharmacokinetics and binding specificity in vivo. QCP01 and [111In]QCP02 demonstrated nanomolar inhibition of FAP at Ki values of 1.26 and 16.20 nM, respectively. Both were selective for FAP over DPP-IV, a related serine protease. Both enabled imaging of FAP-expressing tumors specifically in vivo. [111In]QCP02 showed high uptake at 18.2 percent injected dose per gram in the U87 tumor at 30 min post-administration.
Asunto(s)
Fibroblastos/metabolismo , Colorantes Fluorescentes/química , Gelatinasas/metabolismo , Proteínas de la Membrana/metabolismo , Neoplasias/metabolismo , Serina Endopeptidasas/metabolismo , Animales , Línea Celular Tumoral , Endopeptidasas , Colorantes Fluorescentes/síntesis química , Fluorometría , Xenoinjertos/metabolismo , Humanos , Masculino , Ratones Endogámicos NOD , Ratones SCID , Pirrolidinas/síntesis química , Pirrolidinas/química , Quinolinas/síntesis química , Quinolinas/químicaRESUMEN
[111 In]In-XYIMSR-01 is a promising single-photon emission computed tomography (SPECT) imaging agent for identification of tumors that overexpress carbonic anhydrase IX. To translate [111 In]In-XYIMSR-01 to phase I trials, we performed animal toxicity and dosimetry studies, determined the maximum dose for human use, and completed the chemistry, manufacturing, and controls component of a standard regulatory application. The production process, quality control testing, stability studies, and specifications for sterile drug product release were based on United States Pharmacopeia chapters <823> and <825>, FDA 21 CFR Part 212. Toxicity was evaluated by using nonradioactive [113/115 In]In-XYIMSR-01 according to 21 CFR Part 58 guidelines. Organ Level INternal Dose Assessment/EXponential Modeling (OLINDA/EXM) was used to calculate the maximum single dose for human studies. Three process validation runs at starting radioactivities of ~800 MBq were completed with a minimum concentration of 407 MBq/ml and radiochemical purity of ≥99% at the end of synthesis. A single intravenous dose of 55 µg/ml of [113/115 In]In-XYIMSR-01 was well tolerated in male and female Sprague-Dawley rats. The calculated maximum single dose for human injection from dosimetry studies was 390.35 MBq of [111 In]In-XYIMSR-01. We have completed toxicity and dosimetry studies as well as validated a manufacturing process to test [111 In]In-XYIMSR-01 in a phase I clinical trial.
Asunto(s)
Antígenos de Neoplasias , Anhidrasa Carbónica IXRESUMEN
Therapeutics targeting programmed death ligand 1 (PD-L1) protein and its receptor PD-1 are now dominant players in restoring anti-tumor immune responses. PD-L1 detection by immunohistochemistry (IHC) is emerging as a reproducible biomarker for guiding patient stratification for those therapies in some cancers. However, PD-L1 expression in the tumor microenvironment is highly complex. It is upregulated by aberrant genetic alterations, and is highly regulated at the transcriptional, posttranscriptional, and protein levels. Thus, PD-L1 IHC is inadequate to fully understand the relevance of PD-L1 levels in the whole body and their dynamics to improve therapeutic outcomes. Imaging technologies could potentially assist in meeting that need. Early clinical investigations show promising results in quantifying PD-L1 expression in the whole body by positron emission tomography (PET). Within this context, this review summarizes advancements in regulation of PD-L1 expression and imaging agents, and in PD-L1 PET for drug development, and discusses opportunities and challenges presented by these innovations for guiding immune checkpoint therapy (ICT).
RESUMEN
PURPOSE: Imaging is limited in the evaluation of bacterial infection. Direct imaging of in situ bacteria holds promise for noninvasive diagnosis. We investigated the ability of a bacterial thymidine kinase inhibitor ([124I]FIAU) to image pulmonary and musculoskeletal infections. METHODS: Thirty-three patients were prospectively accrued: 16 with suspected musculoskeletal infection, 14 with suspected pulmonary infection, and 3 with known rheumatoid arthritis without infection. Thirty-one patients were imaged with [124I]FIAU PET/CT and 28 with [18F]FDG PET/CT. Patient histories were reviewed by an experienced clinician with subspecialty training in infectious diseases and were determined to be positive, equivocal, or negative for infection. RESULTS: Sensitivity, specificity, positive-predictive value, negative-predictive value, and accuracy of [124I]FIAU PET/CT for diagnosing infection were estimated as 7.7% to 25.0%, 0.0%, 50%, 0.0%, and 20.0% to 71.4% for musculoskeletal infections and incalculable-100.0%, 51.7% to 72.7%, 0.0% to 50.0%, 100.0%, and 57.1% to 78.6% for pulmonary infections, respectively. The parameters for [18F]FDG PET/CT were 75.0% to 92.3%, 0.0%, 23.1% to 92.3%, 0.0%, and 21.4% to 85.7%, respectively, for musculoskeletal infections and incalculable to 100.0%, 0.0%, 0.0% to 18.2%, incalculable, and 0.0% to 18.2% for pulmonary infections, respectively. CONCLUSIONS: The high number of patients with equivocal clinical findings prevented definitive conclusions from being made regarding the diagnostic efficacy of [124I]FIAU. Future studies using microbiology to rigorously define infection in patients and PET radiotracers optimized for image quality are needed.