Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros













Base de datos
Intervalo de año de publicación
1.
R Soc Open Sci ; 9(5): 212022, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35592762

RESUMEN

There is ongoing and rapid advancement in approaches to modelling the fate of exhaled particles in different environments relevant to disease transmission. It is important that models are verified by comparison with each other using a common set of input parameters to ensure that model differences can be interpreted in terms of model physics rather than unspecified differences in model input parameters. In this paper, we define parameters necessary for such benchmarking of models of airborne particles exhaled by humans and transported in the environment during breathing and speaking.

2.
Sci Rep ; 12(1): 3484, 2022 03 03.
Artículo en Inglés | MEDLINE | ID: mdl-35241703

RESUMEN

Determining the viral load and infectivity of SARS-CoV-2 in macroscopic respiratory droplets, bioaerosols, and other bodily fluids and secretions is important for identifying transmission modes, assessing risks and informing public health guidelines. Here we show that viral load of SARS-CoV-2 Ribonucleic Acid (RNA) in participants' naso-pharyngeal (NP) swabs positively correlated with RNA viral load they emitted in both droplets >10 [Formula: see text] and bioaerosols <10 [Formula: see text] directly captured during the combined expiratory activities of breathing, speaking and coughing using a standardized protocol, although the NP swabs had [Formula: see text] 10[Formula: see text] more RNA on average. By identifying highly-infectious individuals (maximum of 18,000 PFU/mL in NP), we retrieved higher numbers of SARS-CoV-2 RNA gene copies in bioaerosol samples (maximum of 4.8[Formula: see text] gene copies/mL and minimum cycle threshold of 26.2) relative to other studies. However, all attempts to identify infectious virus in size-segregated droplets and bioaerosols were negative by plaque assay (0 of 58). This outcome is partly attributed to the insufficient amount of viral material in each sample (as indicated by SARS-CoV-2 gene copies) or may indicate no infectious virus was present in such samples, although other possible factors are identified.


Asunto(s)
Aerosoles , Tos , Respiración , SARS-CoV-2/aislamiento & purificación , Habla , Carga Viral , Humanos
3.
Sci Rep ; 10(1): 7160, 2020 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-32345986

RESUMEN

Recent increases in marijuana use and legalization without adequate knowledge of the risks necessitate the characterization of the billions of nanoparticles contained in each puff of smoke. Tobacco smoke offers a benchmark given that it has been extensively studied. Tobacco and marijuana smoke particles are quantitatively similar in volatility, shape, density and number concentration, albeit with differences in size, total mass and chemical composition. Particles from marijuana smoke are on average 29% larger in mobility diameter than particles from tobacco smoke and contain 3.4× more total mass. New measurements of semi-volatile fractions determine over 97% of the mass and volume of the particles from either smoke source are comprised of semi-volatile compounds. For tobacco and marijuana smoke, respectively, 4350 and 2575 different compounds are detected, of which, 670 and 536 (231 in common) are tentatively identified, and of these, 173 and 110 different compounds (69 in common) are known to cause negative health effects through carcinogenic, mutagenic, teratogenic, or other toxic mechanisms. This study demonstrates striking similarities between marijuana and tobacco smoke in terms of their physical and chemical properties.


Asunto(s)
Cannabis/química , Nicotiana/química , Humo/análisis , Cromatografía de Gases y Espectrometría de Masas , Volatilización
4.
ACS Sens ; 5(2): 447-453, 2020 02 28.
Artículo en Inglés | MEDLINE | ID: mdl-31922393

RESUMEN

Low-cost methods for measuring airborne microparticles and nanoparticles (aerosols) have remained elusive despite the increasing concern of health impacts from ambient, urban, and indoor sources. While bipolar ion sources are common in smoke alarms, this work is the first to exploit the mean charge on an aerosol resulting from a bipolar charge equilibrium and establish experimentally its correlation to properties of the aerosol particle size distribution. The net current produced from this mean particle charge is demonstrated to be linearly proportional to the product of the mean particle diameter and total number concentration (i ∼ Nd̅) for two bipolar ion sources (85Kr and 241Am). This conclusion is supported by simple equations derived from well-established bipolar charging theory. The theory predicts that the mean charge on the aerosol particles reaches an equilibrium, which, importantly, is independent of the concentration of charging ions. Furthermore, in situ measurements of a roadside aerosol demonstrate that the sensing method yields results in good agreement (R2 = 0.979) with existing portable and laboratory-grade aerosol instruments. The simplicity, stability, and cost of the bipolar ion source overcome challenges of other portable sensors, increasing the feasibility of widespread sensor deployment to monitor ultrafine particle characteristics, which are relevant to lung deposition and by extension, human health.


Asunto(s)
Aerosoles/química , Monitoreo del Ambiente/métodos , Material Particulado/química , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA