1.
Rheumatology (Oxford) ; 61(3): 943-952, 2022 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-33993221

RESUMEN

OBJECTIVES: Pulmonary manifestations in RA are common comorbidities. Interstitial lung disease (ILD), both idiopathic and in RA, has been associated with several genetic variants. We assessed pulmonary fibrosis (PF) in an inception cohort of RA patients in relation to genetic variants and disease-related factors. METHODS: A total of 1466 early RA patients were consecutively included and followed prospectively from the index date until death or 31 December 2016. Clinical and laboratory data and treatment were continuously registered according to the Swedish Rheumatology Quality Register. DNA was available from 1184 patients and 571 151 genome-wide single-nucleotide polymorphisms (SNPs) were analysed. Thirteen identified genetic variants were extracted. At follow-up, the patients answered a questionnaire regarding disease progression and lung involvement that was validated by reviewing medical records and analysing radiological examinations. RESULTS: The prevalence of PF was 5.6% and the annualized incidence rate was 5.0/1000 (95% CI 3.80, 6.54). Four SNPs were associated with PF in RA: rs35705950 [MUC5B; OR 2.5 (95% CI 1.5, 4.0), adjusted P-value = 0.00016, q-value = 0.0021]; rs111521887 [TOLLIP; OR 1.9 (95% CI 1.3, 2.8), adjusted P-value = 0.0014, q-value = 0.0092]; rs2609255 [FAM13A; OR 1.7 (95% CI 1.1, 2.5), adjusted P-value = 0.013, q-value = 0.055] and rs2736100 [TERT; OR 1.5 (95% CI 1.0, 2.2), adjusted P-value = 0.046, q-value = 0.15]. Older age and RF positivity were associated with increased risk, while MTX treatment was associated with a lower risk of PF. CONCLUSIONS: Development of PF in an inception cohort of RA patients was associated with 4 of 12 ILD risk genes. RA-related factors except for age at diagnosis and RF positivity were of limited importance in PF development.


Asunto(s)
Artritis Reumatoide/epidemiología , Fibrosis Pulmonar/epidemiología , Factores de Edad , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Proteínas Activadoras de GTPasa/genética , Humanos , Péptidos y Proteínas de Señalización Intracelular/genética , Masculino , Persona de Mediana Edad , Mucina 5B/genética , Polimorfismo de Nucleótido Simple , Fibrosis Pulmonar/genética , Factor Reumatoide/sangre , Suecia/epidemiología , Telomerasa/genética
2.
Acta Radiol Open ; 7(5): 2058460118772863, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29760949

RESUMEN

BACKGROUND: The radiation dose for patients can be reduced with many methods and one way is to use abdominal compression. In this study, the radiation dose and image quality for a new patient-controlled compression device were compared with conventional compression and compression in the prone position. PURPOSE: To compare radiation dose and image quality of patient-controlled compression compared with conventional and prone compression in general radiography. MATERIAL AND METHODS: An experimental design with quantitative approach. After obtaining the approval of the ethics committee, a consecutive sample of 48 patients was examined with the standard clinical urography protocol. The radiation doses were measured as dose-area product and analyzed with a paired t-test. The image quality was evaluated by visual grading analysis. Four radiologists evaluated each image individually by scoring nine criteria modified from the European quality criteria for diagnostic radiographic images. RESULTS: There was no significant difference in radiation dose or image quality between conventional and patient-controlled compression. Prone position resulted in both higher dose and inferior image quality. CONCLUSION: Patient-controlled compression gave similar dose levels as conventional compression and lower than prone compression. Image quality was similar with both patient-controlled and conventional compression and was judged to be better than in the prone position.

3.
Acta Radiol ; 58(6): 702-709, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28157395

RESUMEN

Background Iterative reconstruction (IR) is a recent reconstruction algorithm for computed tomography (CT) that can be used instead of the standard algorithm, filtered back projection (FBP), to reduce radiation dose and/or improve image quality. Purpose To evaluate and compare the image quality of low-dose CT of the lumbar spine reconstructed with IR to conventional FBP, without further reduction of radiation dose. Material and Methods Low-dose CT on 55 patients was performed on a Siemens scanner using 120 kV tube voltage, 30 reference mAs, and automatic dose modulation. From raw CT data, lumbar spine CT images were reconstructed with a medium filter (B41f) using FBP and four levels of IR (levels 2-5). Five reviewers scored all images on seven image quality criteria according to the European guidelines on quality criteria for CT, using a five-grade scale. A side-by-side comparison was also performed. Results There was significant improvement in image quality for IR (levels 2-4) compared to FBP. According to visual grading regression, odds ratios of all criteria with 95% confidence intervals for IR2, IR3, IR4, and IR5 were: 1.59 (1.39-1.83), 1.74 (1.51-1.99), 1.68 (1.46-1.93), and 1.08 (0.94-1.23), respectively. In the side-by-side comparison of all reconstructions, images with IR (levels 2-4) received the highest scores. The mean overall CTDIvol was 1.70 mGy (SD 0.46; range, 1.01-3.83 mGy). Image noise decreased in a linear fashion with increased strength of IR. Conclusion Iterative reconstruction at levels 2, 3, and 4 improves image quality of low-dose CT of the lumbar spine compared to FPB.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Vértebras Lumbares/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X/métodos , Adulto Joven
4.
Br J Radiol ; 89(1063): 20150993, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27123700

RESUMEN

OBJECTIVE: To evaluate metal artefact reduction (MAR) techniques from four CT vendors in hip prosthesis imaging. METHODS: Bilateral hip prosthesis phantom images, obtained by using MAR algorithms for single-energy CT data or dual-energy CT (DECT) data and by monoenergetic reconstructions of DECT data, were visually graded by five radiologists using 10 image quality criteria. Comparisons between the MAR images and a reference image were performed for each scanner separately. Ordinal probit regression analysis was used. RESULTS: The MAR algorithms in general improved the image quality based on the majority of the criteria (up to between 8/10 and 10/10) with a statistical improvement in overall image quality (p < 0.001). However, degradation of image quality, such as new artefacts, was seen in some cases. A few monoenergetic reconstruction series improved the image quality (p < 0.004) for one of the DECT scanners, but it was only improved for some of the criteria (up to 5/10). Monoenergetic reconstructions resulted in worse image quality for the majority of the criteria (up to 7/10) for the other DECT scanner. CONCLUSION: The MAR algorithms improved the image quality of the hip prosthesis CT images. However, since additional artefacts and degradation of image quality were seen in some cases, all algorithms should be carefully evaluated for every clinical situation. Monoenergetic reconstructions were in general concluded to be insufficient for reducing metal artefacts. ADVANCES IN KNOWLEDGE: Qualitative evaluation of the usefulness of several MAR techniques from different vendors in CT imaging of hip prosthesis.


Asunto(s)
Artefactos , Articulación de la Cadera/diagnóstico por imagen , Prótesis de Cadera , Metales , Fantasmas de Imagen , Tomografía Computarizada por Rayos X , Algoritmos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Eur Radiol ; 26(6): 1766-74, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26385800

RESUMEN

OBJECTIVES: Abdominal radiography is frequently used in acute abdominal non-traumatic pain despite the availability of more advanced diagnostic modalities. This study evaluates the diagnostic accuracy of low-dose CT compared with abdominal radiography, at similar radiation dose levels. METHODS: Fifty-eight patients were imaged with both methods and were reviewed independently by three radiologists. The reference standard was obtained from the diagnosis in medical records. Sensitivity and specificity were calculated. A systematic review was performed after a literature search, finding a total of six relevant studies including the present. RESULTS: Overall sensitivity with 95 % CI for CT was 75 % (66-83 %) and 46 % (37-56 %) for radiography. Specificity was 87 % (77-94 %) for both methods. In the systematic review the overall sensitivity for CT varied between 75 and 96 % with specificity from 83 to 95 % while the overall sensitivity for abdominal radiography varied between 30 and 77 % with specificity 75 to 88 %. CONCLUSIONS: Based on the current study and available evidence, low-dose CT has higher diagnostic accuracy than abdominal radiography and it should, where logistically possible, replace abdominal radiography in the workup of adult patients with acute non-traumatic abdominal pain. KEY POINTS: • Low-dose CT has a higher diagnostic accuracy than radiography. • A systematic review shows that CT has better diagnostic accuracy than radiography. • Radiography has no place in the workup of acute non-traumatic abdominal pain.


Asunto(s)
Dolor Abdominal/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Errores Diagnósticos , Diverticulitis del Colon/complicaciones , Diverticulitis del Colon/diagnóstico por imagen , Femenino , Hernia Abdominal/complicaciones , Hernia Abdominal/diagnóstico por imagen , Hernia Inguinal/complicaciones , Hernia Inguinal/diagnóstico por imagen , Humanos , Obstrucción Intestinal/complicaciones , Obstrucción Intestinal/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos , Dosis de Radiación , Radiografía Abdominal/métodos , Sensibilidad y Especificidad , Neoplasias del Colon Sigmoide/complicaciones , Neoplasias del Colon Sigmoide/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas , Adulto Joven
6.
Acta Radiol ; 57(5): 602-11, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26221055

RESUMEN

BACKGROUND: Lumbar spine radiography is often performed instead of CT for radiation dose concerns. PURPOSE: To compare image quality and diagnostic information from low dose lumbar spine CT at an effective dose of about 1 mSv with lumbar spine radiography. MATERIAL AND METHODS: Fifty-one patients were examined by both methods. Five reviewers scored all examinations on eight image quality criteria using a five-graded scale and also assessed three common pathologic changes. RESULTS: Low dose CT scored better than radiography on the following: sharp reproduction of disc profile and vertebral end-plates (odds ratio [OR], 1.8; 95% confidence interval [CI], 1.3-2.5), intervertebral foramina and pedicles (OR, 4.3; 95% CI, 3.1-5.9), intervertebral joints (OR, 139; 95% CI, 59-326), spinous and transverse processes (OR, 7.0; 95% CI, 4.3-11.2), sacro-iliac joints (OR, 4.2; 95% CI, 3.2-5.7), reproduction of the adjacent soft tissues (OR, 2.9; 95% CI, 2.1-4.0), and absence of any obscuring superimposed gastrointestinal gas and contents (OR, 188; 95% CI, 66-539). Radiography scored better on sharp reproduction of cortical and trabecular bone (OR, 0.3; 95% CI, 0.2-0.4). The reviewers visualized disk degeneration, spondylosis/diffuse idiopathic skeletal hyperostosis (DISH) and intervertebral joint osteoarthritis more clearly and were more certain with low dose CT. Mean time to review low dose CT was 204 s (95% CI, 194-214 s.), radiography 152 s (95% CI, 146-158 s.). The effective dose for low dose CT was 1.0-1.1 mSv, for radiography 0.7 mSv. CONCLUSION: Low dose lumbar spine CT at about 1 mSv has superior image quality to lumbar spine radiography with more anatomical and diagnostic information.


Asunto(s)
Vértebras Lumbares/diagnóstico por imagen , Dosis de Radiación , Enfermedades de la Columna Vertebral/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad
7.
Acta Radiol ; 55(7): 824-32, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24215904

RESUMEN

BACKGROUND: Lumbar spine radiography has limited diagnostic value but low radiation dose compared with computed tomography (CT). The average effective radiation dose from lumbar spine radiography is about 1.1 mSv. Low-dose lumbar spine CT may be an alternative to increase the diagnostic value at low radiation dose, around 1 mSv. PURPOSE: To determine the optimal settings for low-dose lumbar spine CT simultaneously aiming for the highest diagnostic image quality possible. MATERIAL AND METHODS: An ovine lower thoracic and lumbar spine phantom, with all soft tissues around the vertebrae preserved except the skin, was placed in a 20 L plastic container filled with water. The phantom was scanned repeatedly with various technical settings; different tube potential, reference mAs, and with different convolution filters. Five radiologists evaluated the image quality according to a modification of the European guidelines for multislice computed tomography (MSCT) quality criteria for lumbar spine CT 2004. In a visual comparison the different scans were also ranked subjectively according to perceived image quality. Image noise and contrast were measured. RESULTS: A tube potential of 120 kV with reference mAs 30 and medium or medium smooth convolution filter gave the best image quality at a sub-millisievert dose level, i.e. with an effective dose comparable to that from lumbar spine radiography. CONCLUSION: Low-dose lumbar spine CT thus opens a possibility to substitute lumbar spine radiography with CT without obvious increase in radiation dose.


Asunto(s)
Vértebras Lumbares/diagnóstico por imagen , Dosis de Radiación , Protección Radiológica/métodos , Intensificación de Imagen Radiográfica/métodos , Vértebras Torácicas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Animales , Humanos , Variaciones Dependientes del Observador , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Ovinos , Tomografía Computarizada por Rayos X/instrumentación
8.
Respir Res ; 9: 63, 2008 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-18721453

RESUMEN

BACKGROUND: To our knowledge, no studies of the possible association of early life environment with snoring in adulthood have been published. We aimed to investigate whether early life environment is associated with snoring later in life. METHODS: A questionnaire including snoring frequency in adulthood and environmental factors in early life was obtained from 16,190 randomly selected men and women, aged 25-54 years, in Sweden, Norway, Iceland, Denmark and Estonia (response rate 74%). RESULTS: A total of 15,556 subjects answered the questions on snoring. Habitual snoring, defined as loud and disturbing snoring at least 3 nights a week, was reported by 18%. Being hospitalized for a respiratory infection before the age of two years (adjusted odds ratio (OR) = 1.27; 95% confidence interval (CI) 1.01-1.59), suffering from recurrent otitis as a child (OR = 1.18; 95%CI 1.05-1.33), growing up in a large family (OR = 1.04; 95%CI 1.002-1.07) and being exposed to a dog at home as a newborn (OR = 1.26; 95%CI 1.12-1.42) were independently related to snoring later in life and independent of a number of possible confounders in adulthood. The same childhood environmental factors except household size were also related with snoring and daytime sleepiness combined. CONCLUSION: The predisposition for adult snoring may be partly established early in life. Having had severe airway infections or recurrent otitis in childhood, being exposed to a dog as a newborn and growing up in a large family are environmental factors associated with snoring in adulthood.


Asunto(s)
Ronquido/epidemiología , Adulto , Factores de Edad , Causalidad , Comorbilidad , Exposición a Riesgos Ambientales/estadística & datos numéricos , Estonia/epidemiología , Composición Familiar , Femenino , Encuestas Epidemiológicas , Humanos , Masculino , Persona de Mediana Edad , Otitis Media/epidemiología , Infecciones del Sistema Respiratorio/epidemiología , Países Escandinavos y Nórdicos/epidemiología , Encuestas y Cuestionarios
9.
Phys Med Biol ; 52(17): 5263-76, 2007 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-17762085

RESUMEN

In the optimization process of lumbar spine examinations, factorial experiments were performed addressing the question of whether the effective dose can be reduced and the image quality maintained by adjusting the image processing parameters. A 2k-factorial design was used which is a systematic and effective method of investigating the influence of many parameters on a result variable. Radiographic images of a Contrast Detail phantom were exposed using the default settings of the process parameters for lumbar spine examinations. The image was processed using different settings of the process parameters. The parameters studied were ROI density, gamma, detail contrast enhancement (DCE), noise compensation, unsharp masking and unsharp masking kernel (UMK). The images were computer analysed and an image quality figure (IQF) was calculated and used as a measurement of the image quality. The parameters with the largest influence on image quality were noise compensation, unsharp masking, unsharp masking kernel and detail contrast enhancement. There was an interaction between unsharp masking and kernel indicating that increasing the unsharp masking improved the image quality when combined with a large kernel size. Combined with a small kernel size however the unsharp masking had a deteriorating effect. Performing a factorial experiment gave an overview of how the image quality was influenced by image processing. By adjusting the level of noise compensation, unsharp masking and kernel, the IQF was improved to a 30% lower effective dose.


Asunto(s)
Algoritmos , Vértebras Lumbares/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Pantallas Intensificadoras de Rayos X , Análisis Factorial , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
Respir Med ; 101(7): 1431-8, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17350816

RESUMEN

OBJECTIVE: Some studies have shown an association between lower maternal age at delivery and increased asthma in children and young adults. It is unclear whether this represents an effect of maternal ageing or a protective effect of siblings. In a North-European population based study, we investigated whether mother's age at delivery was associated with risk for asthma and hay fever in adult offspring, taking into account relevant confounders. METHODS: A total of 16,190 subjects (74%) aged 23-54 yr answered a postal questionnaire in a follow-up of the European Community Respiratory Health Survey (ECRHS I). RESULTS: The associations of maternal age at delivery with hay fever, respiratory symptoms and diagnosed asthma were analysed using logistic regression, adjusting for household size, dwelling, parental education, centre, gender, adult hay fever, smoking, age and body mass index (BMI). The adjusted odds ratios (95% CI) for wheeze with breathlessness, wheeze without a cold and asthma in the offspring were 0.94 (0.90-0.99), 0.89 (0.86-0.94) and 0.92 (0.88-0.97), respectively, per 5 yr increase in maternal age. No heterogeneity between centres was found (p=0.84). The estimates remained similar in sub-sample analyses when adjusting for siblings, maternal smoking (n=3109) and for birth weight (n=1686). Hay fever was more common among those with the youngest and oldest mothers. CONCLUSIONS: In this large North-European multi-centre study, asthma was less common with increasing maternal age. This effect was consistent between centres and persisted with adjustment for several potential confounders, suggesting that the association may possibly be explained by biological changes related to maternal ageing.


Asunto(s)
Asma/etiología , Edad Materna , Adolescente , Adulto , Factores de Edad , Asma/embriología , Asma/epidemiología , Métodos Epidemiológicos , Europa (Continente)/epidemiología , Composición Familiar , Femenino , Humanos , Masculino , Persona de Mediana Edad , Embarazo , Efectos Tardíos de la Exposición Prenatal , Rinitis Alérgica Estacional/embriología , Rinitis Alérgica Estacional/epidemiología , Rinitis Alérgica Estacional/etiología
11.
Respir Med ; 100(10): 1843-9, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16516455

RESUMEN

BACKGROUND: Respiratory symptoms are related to anxiety and depression in several cross-sectional studies but the association has not been explored in longitudinal studies. STUDY OBJECTIVES: To prospectively study the change in dyspnea in relation to symptoms of anxiety and depression over a 9-year time period. METHODS: The study comprised of 515 adults from a population sample who had participated in the European Commission Respiratory Health Survey (ECRHS) I in 1991-1992 and in the ECRHS II in 1999-2000. The questionnaire included a modified British Medical Research Council Scale for dyspnea grading and the Hospital Anxiety and Depression scale questionnaire. RESULTS: The prevalence of dyspnea was 10.7% in the first and 12.6% in the second survey. Symptoms of depression was an independent determinants for dyspnea in both surveys (OR (95% CI) 3.72 (1.51-9.17) and 3.40 (1.49-7.80), respectively). In subjects that did not have dyspnea at the first survey onset of symptoms of anxiety (OR 3.53 (1.03-12.1)) and depression (OR 12.2 (3.97-37.5)) were significantly related to having dyspnea at the second survey, whereas onset of dyspnea was not significantly associated with developing symptoms of anxiety or depression when each disorder was entered separately. CONCLUSION: Our data indicates that there is a causal relationship between development of symptoms of anxiety and depression and dyspnea. Psychological status is therefore an important factor to consider both when evaluating the results of epidemiological respiratory studies and in clinical settings when treating patients that have dyspnea.


Asunto(s)
Trastornos de Ansiedad/complicaciones , Trastorno Depresivo/complicaciones , Disnea/psicología , Adulto , Asma/complicaciones , Índice de Masa Corporal , Estudios Transversales , Femenino , Volumen Espiratorio Forzado/fisiología , Humanos , Masculino , Estudios Prospectivos , Factores de Riesgo , Fumar/efectos adversos
12.
Radiat Prot Dosimetry ; 114(1-3): 246-52, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15933116

RESUMEN

To find if factorial experiments can be used in the optimisation of diagnostic imaging, a factorial experiment was performed to investigate some of the factors that influence image quality, kerma area product (KAP) and effective dose (E). In a factorial experiment the factors are varied together instead of one at a time, making it possible to discover interactions between the factors as well as major effects. The factors studied were tube potential, tube loading, focus size and filtration. Each factor was set to two levels (low and high). The influence of the factors on the response variables (image quality, KAP and E) was studied using a direct digital detector. The major effects of each factor on the response variables were estimated as well as the interaction effects between factors. The image quality, KAP and E were mainly influenced by tube loading, tube potential and filtration. There were some active interactions, for example, between tube potential and filtration and between tube loading and filtration. The study shows that factorial experiments can be used to predict the influence of various parameters on image quality and radiation dose.


Asunto(s)
Intensificación de Imagen Radiográfica/métodos , Radiometría/métodos , Humanos , Procesamiento de Imagen Asistido por Computador , Modelos Estadísticos , Fantasmas de Imagen , Radiación , Dosis de Radiación , Protección Radiológica , Dispersión de Radiación , Pantallas Intensificadoras de Rayos X