RESUMEN
Nonafact(®), an ultrapure, monoclonal antibody-purified factor IX concentrate (FIX) was developed to minimize risk of thrombotic complications and viral transmission. To investigate the pharmacokinetics, efficacy and safety, phase III/IV studies were performed in the Netherlands and Poland from 1996 to 2007. The mean half-life, in vivo response and recovery of Nonafact(®) were 18.7 (SD 2.0) h, 1.1 (SD 0.2) IU dL(-1) per IU kg(-1) b.w. of FIX infused and 49% (SD 10%), respectively. Eleven surgical procedures were performed in eight patients. During two surgeries, both high-risk, blood loss was observed. No postoperative bleeding occurred. The in vivo recovery of FIX was higher than expected. In the phase III follow-up study, 26 previously treated patients (PTP) were included with a median follow-up of 1130 days. From the 1617 minor bleedings, 80.5% was stopped after a single infusion. In the phase IV study thirteen patients were treated for a median study period of 737 days. In the two follow-up studies the investigators rated the effect of Nonafact(®) as excellent/good in 95% of major bleedings. Surgeries for which Nonafact(®) was given prophylactically were without bleeding problems. In total more than 10 million units of Nonafact(®) were used during almost 120 person-years. Only one minor adverse event was reported. No inhibitors, viral transmissions and thrombogenic events occurred. In conclusion, Nonafact(®) is safe and provides excellent haemostasis in haemophilia B patients treated for spontaneous bleeding or undergoing surgical procedures. Due to the excellent in vivo recovery characteristic, treatment with Nonafact(®) is cost saving compared to other FIX products.
Asunto(s)
Anticuerpos Monoclonales/uso terapéutico , Factor IX/uso terapéutico , Hemofilia B/tratamiento farmacológico , Adolescente , Adulto , Anticuerpos Monoclonales/farmacocinética , Pérdida de Sangre Quirúrgica/prevención & control , Factor IX/farmacocinética , Estudios de Seguimiento , Hemofilia B/cirugía , Hemostasis Quirúrgica/métodos , Humanos , Persona de Mediana Edad , Países Bajos , Polonia , Hemorragia Posoperatoria/prevención & control , Adulto JovenAsunto(s)
Aspirina/efectos adversos , Factores de Coagulación Sanguínea/administración & dosificación , Factor VIIa/administración & dosificación , Inhibidor de Coagulación del Lupus/efectos adversos , Insuficiencia Renal/etiología , Anciano , Humanos , Masculino , Proteínas Recombinantes/administración & dosificaciónRESUMEN
The appearance of inhibitory antibodies against factor VIII (FVIII) is the most severe and costly complication of replacement therapy in patients with haemophilia A (HA). To determine the relationship between FVIII genotype and inhibitor development, baseline FVIII activity, genotype and inhibitor development were reviewed in 1104 patients with HA. In patients with severe HA, splicing errors present the highest frequency of inhibitors, ahead of inversion of intron 1 and of intron 22, nonsense mutations and large deletions. The lowest inhibitor frequency in severe HA is found in patients with missense mutations and small deletions/insertions. Subanalyses indicate that nonsense mutations and small deletions/insertions leading to a frameshift in the light chain are associated with a significant higher risk of inhibitor formation than similar mutations occurring in the heavy chain (27% vs. 14%). These mutation types also have a higher frequency of inhibitors when occurring in exons 23-26, where a second FVIII transcript originates, compared with similar mutations in exons 1-22 (28% vs. 17%). These results suggest that complete absence of FVIII because of null mutations, including splice site mutations, or the absence of a second transcript result in an increased risk of inhibitor development.
Asunto(s)
Autoanticuerpos/sangre , Factor VIII/genética , Hemofilia A/genética , Mutación , Sitios de Empalme de ARN/genética , Estudios de Cohortes , Análisis Mutacional de ADN/métodos , Factor VIII/antagonistas & inhibidores , Factor VIII/inmunología , Factor VIII/uso terapéutico , Predisposición Genética a la Enfermedad , Genotipo , Hemofilia A/tratamiento farmacológico , Hemofilia A/inmunología , Humanos , Masculino , FenotipoRESUMEN
BACKGROUND: We recently described a new autosomal recessive type of Ehlers-Danlos syndrome (EDS) based on a deficiency of the extracellular matrix protein tenascin-X (TNX). TNX-deficient patients have hypermobile joints, hyperextensible skin and show easy bruising. Because of the reported cardiovascular abnormalities in other EDS types and the excessive haematoma formation after mild trauma in TNX-deficient individuals, we investigated whether cardiovascular or coagulation abnormalities occur in these patients. METHODS: We examined seven TNX-deficient patients. One of them had a mitral valve prolapse and died postoperatively after valve replacement, before the study was completed. RESULTS: Bleeding time and coagulation factors (INR, APTT, PT and fibrinogen) were all within the normal range. Ultrasonographic examination of the carotid and femoral arteries showed normal vessel wall compliance and distensibility. Echocardiography showed a slight billowing of the mitral valve in two patients from one family. All patients had normal diameters of aortic root and ascending aorta. CONCLUSION: Although the patient group is small, there are no indications of generalised cardiovascular abnormalities in this type of EDS. We would recommend echocardiography for all these patients at the first evaluation and when a cardiac murmur appears.
Asunto(s)
Síndrome de Ehlers-Danlos/diagnóstico , Tenascina/deficiencia , Ecocardiografía , Síndrome de Ehlers-Danlos/complicaciones , Síndrome de Ehlers-Danlos/genética , Síndrome de Ehlers-Danlos/metabolismo , Humanos , Prolapso de la Válvula Mitral/complicaciones , Prolapso de la Válvula Mitral/diagnóstico por imagenRESUMEN
AAFACT, a monoclonal purified, solvent/detergent treated human plasma-derived coagulation factor VIII concentrate obtained from plasma of voluntary, non-remunerated blood donors, is manufactured and marketed in the Netherlands by Sanquin Plasma Products since 1995. In a postmarketing surveillance study, 70 previously treated haemophilia A patients were included (73% severe, 14% moderate and 13% mild haemophilia A). Most of these patients were followed during 4 years for the appearance of adverse events, possible transmissions of blood-borne viruses and the occurrence of antibodies against FVIII. The efficacy of treatment was determined in each patient by the in vivo recovery of FVIII. During this study, only six adverse events, possibly related to the use of AAFACT, were reported. None of these were indicated as serious. Transmissions of HIV, HAV, HBV and HCV in the seronegative patients have not been observed. In none of the patients, inhibitors to FVIII were detected. The in vivo recovery of FVIII during this study was not different from the in vivo recovery observed in eight patients during the preregistration study. There was a correlation of in vivo recovery with age and body weight. From these results, we conclude that the clinical usage of this human plasma-derived FVIII product is efficient and safe.