Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Clin Pharmacol Drug Dev ; 11(6): 754-760, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35166054

RESUMEN

This phase 1 study compared the pharmacokinetic (PK) and glucose pharmacodynamic (PD) characteristics of biosimilar SAR342434 insulin lispro and Japan-reference Humalog insulin lispro. This was a randomized, double-blind, 2-period, crossover study. Thirty-six healthy Japanese male subjects underwent a 10-hour euglycemic clamp following a single subcutaneous 0.3-U/kg dose of SAR342434 or Humalog. Insulin lispro concentration and blood glucose were measured, and the glucose infusion rate (GIR) was adjusted to maintain the target blood glucose level. Primary PK end points were maximum plasma insulin lispro concentration and area under the plasma insulin concentration-time curve (AUC) from time 0 to the last quantifiable concentration. Primary PD end points were area under the GIR-time curve from time 0 to 10 hours and maximum GIR. PK exposure (maximum plasma concentration and AUC from time 0 to the last quantifiable concentration) and PD activity (GIR-AUC from time 0 to 10 hours and maximum GIR) were similar between treatments. Geometric mean ratios were close to 1, and the corresponding 90% and 95%CIs (PK and PD activity, respectively) were within the 0.80 to 1.25 equivalence range. SAR342434 and Humalog were well tolerated. In healthy Japanese males, SAR342434 and Humalog showed similar PK exposure profiles and PD potency, in support of SAR342434 use as a biosimilar product.


Asunto(s)
Biosimilares Farmacéuticos , Biosimilares Farmacéuticos/efectos adversos , Biosimilares Farmacéuticos/farmacocinética , Glucemia , Estudios Cruzados , Glucosa , Humanos , Hipoglucemiantes , Insulina Lispro , Japón , Masculino
2.
Cell Metab ; 34(1): 59-74.e10, 2022 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-34932984

RESUMEN

Unimolecular triple incretins, combining the activity of glucagon-like peptide-1 (GLP-1), glucose-dependent insulinotropic polypeptide (GIP), and glucagon (GCG), have demonstrated reduction in body weight and improved glucose control in rodent models. We developed SAR441255, a synthetic peptide agonist of the GLP-1, GCG, and GIP receptors, structurally based on the exendin-4 sequence. SAR441255 displays high potency with balanced activation of all three target receptors. In animal models, metabolic outcomes were superior to results with a dual GLP-1/GCG receptor agonist. Preclinical in vivo positron emission tomography imaging demonstrated SAR441255 binding to GLP-1 and GCG receptors. In healthy subjects, SAR441255 improved glycemic control during a mixed-meal tolerance test and impacted biomarkers for GCG and GIP receptor activation. Single doses of SAR441255 were well tolerated. The results demonstrate that integrating GIP activity into dual GLP-1 and GCG receptor agonism provides improved effects on weight loss and glycemic control while buffering the diabetogenic risk of chronic GCG receptor agonism.


Asunto(s)
Receptor del Péptido 1 Similar al Glucagón , Control Glucémico , Incretinas , Receptores de la Hormona Gastrointestinal , Receptores de Glucagón , Pérdida de Peso , Animales , Polipéptido Inhibidor Gástrico , Péptido 1 Similar al Glucagón , Receptor del Péptido 1 Similar al Glucagón/agonistas , Humanos , Incretinas/farmacología , Péptidos/farmacología , Receptores de la Hormona Gastrointestinal/agonistas , Receptores de Glucagón/agonistas , Pérdida de Peso/efectos de los fármacos
3.
Sci Rep ; 11(1): 22931, 2021 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-34824344

RESUMEN

This study compared the pharmacokinetic and glucodynamic profiles of biosimilar SAR341402 insulin aspart to Japan-approved insulin aspart (NovoRapid) in healthy Japanese males. In this single-center, randomized, double-blind, single-dose, two-period, crossover study, subjects received 0.3 U/kg of SAR341402 or NovoRapid before undergoing a 10 h euglycemic clamp procedure. Plasma insulin aspart concentrations and blood glucose levels were measured, and glucose infusion rates (GIRs) were assessed. Primary endpoints were maximum plasma insulin aspart concentration (INS-Cmax), area under the plasma insulin concentration-time curve to the last quantifiable concentration (INS-AUClast), area under the GIR-time curve during the clamp (GIR-AUC0-10 h), and maximum GIR (GIRmax). Forty subjects were randomized with 39 completing both treatment periods. Pharmacokinetic exposure showed a mean ratio between products of 1.00 (90% confidence interval [CI] 0.94-1.05) for INS-Cmax and 1.02 (90% CI 1.00-1.04) for INS-AUClast. Glucodynamic activity showed a mean ratio between products of 1.00 (95% CI 0.93-1.06) for GIR-AUC0-10 h and 1.01 (95% CI 0.95-1.08) for GIRmax. The 90% CIs for pairwise treatment ratios were within the predefined equivalence range of 0.80-1.25. Both treatments were well tolerated. We concluded that similar pharmacokinetic exposure and glucodynamic potency were shown for SAR341402 and NovoRapid in healthy Japanese males.


Asunto(s)
Biosimilares Farmacéuticos/farmacocinética , Glucemia/efectos de los fármacos , Hipoglucemiantes/farmacocinética , Insulina Aspart/farmacocinética , Adulto , Biomarcadores/sangre , Biosimilares Farmacéuticos/administración & dosificación , Biosimilares Farmacéuticos/efectos adversos , Glucemia/metabolismo , Estudios Cruzados , Método Doble Ciego , Voluntarios Sanos , Humanos , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/efectos adversos , Insulina Aspart/administración & dosificación , Insulina Aspart/efectos adversos , Japón , Masculino , Persona de Mediana Edad , Equivalencia Terapéutica , Adulto Joven
4.
Diabetes Obes Metab ; 23(3): 674-681, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33236518

RESUMEN

AIM: To compare the pharmacokinetic exposure of SAR341402 Mix 70/30 (SARAsp -Mix) with US- and European (EU)-approved versions of insulin aspart Mix 70/30 (NovoLog Mix 70/30 [NN-Mix-US]/NovoMix 30 [NN-Mix-EU]) and SAR341402 insulin aspart solution (SAR-Asp) in subjects with type 1 diabetes. MATERIALS AND METHODS: This was a randomized, double-blind, crossover trial in two cohorts. Fifty-two subjects received a single subcutaneous 0.3 U/kg dose of each treatment and underwent a euglycaemic clamp procedure lasting for a maximum of 24 hours after dosing. In cohort 1, subjects (N = 36) were exposed once each to SARAsp -Mix, NN-Mix-US and NN-Mix-EU. In cohort 2, subjects (N = 16) were exposed once each to SARAsp -Mix and SAR-Asp. RESULTS: Of the 52 subjects randomized, 48 completed all treatment periods. In cohort 1, the extent of exposure (total and maximum concentration) was similar among the three treatments, with the 90% confidence intervals for pairwise treatment ratios meeting the predefined acceptance range (0.80 to 1.25). In cohort 2, statistically significant differences (P < .001) in early (0-4 hours) and intermediate (4-12 hours) exposure to SARAsp -Mix compared with SAR-Asp were observed, all exceeding a 20% difference. Pharmacodynamic results were in support of the pharmacokinetic findings for both cohorts. All treatments were well tolerated and there were no relevant differences in safety variables among treatments. CONCLUSIONS: SARAsp -Mix showed similar pharmacokinetic exposure to commercially available insulin aspart Mix 70/30 formulations, and a distinct exposure profile compared with SAR-Asp.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina Aspart , Glucemia , Estudios Cruzados , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Método Doble Ciego , Técnica de Clampeo de la Glucosa , Humanos , Hipoglucemiantes/efectos adversos , Insulina Aspart/efectos adversos
5.
Diabetes Technol Ther ; 22(4): 278-284, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31825248

RESUMEN

Background: The objective of this study was to demonstrate the pharmacokinetic and pharmacodynamic similarity among SAR341402 insulin aspart biosimilar/follow-on product, United States-sourced insulin aspart (NovoLog®), and European Union-sourced insulin aspart (NovoRapid®). Materials and Methods: This was a single-center, randomized, double-blind, 3-treatment, 3-period, single-dose, crossover euglycemic study (NCT03202875) in 30 adult male subjects with type 1 diabetes (T1D). Subjects received 0.3 U/kg of each treatment under fasted conditions and underwent a 12-h euglycemic clamp technique to assess pharmacokinetic and pharmacodynamic activity for up to 12 h. Primary endpoints were area under the plasma insulin concentration-time curve from time zero to the last quantifiable concentration (INS-AUClast), and extrapolated to infinity (INS-AUCinf), maximum plasma insulin concentration (INS-Cmax), and the area under the body weight-standardized glucose infusion rate (GIR)-time curve from 0 to 12 hours (GIR-AUC0-12h) among the three treatments. GIRmax was the main secondary endpoint. Results: Of the 30 subjects randomized, 29 completed all 3 treatment periods. Pharmacokinetic and pharmacodynamic profiles were similar in all groups. The extent of exposure (INS-Cmax, INS-AUClast, and INS-AUCinf) and glucodynamic activity (GIR-AUC0-12h, GIRmax) was similar among the three treatments. The corresponding 90% confidence intervals for pairwise treatment ratios were completely contained within the limits of 80%-125%. SAR341402 was well tolerated. Conclusions: The present study demonstrated similar pharmacokinetic exposure profiles and glucodynamic potency among SAR341402, NovoLog, and NovoRapid in subjects with T1D, supporting further clinical evaluation of SAR341402 as a biosimilar/follow-on product.


Asunto(s)
Biosimilares Farmacéuticos/farmacocinética , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Técnica de Clampeo de la Glucosa , Hipoglucemiantes/farmacocinética , Insulina Aspart/farmacocinética , Adolescente , Adulto , Anciano , Glucemia/efectos de los fármacos , Estudios Cruzados , Diabetes Mellitus Tipo 1/sangre , Método Doble Ciego , Unión Europea , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Estados Unidos , Adulto Joven
6.
Diabetes Technol Ther ; 22(9): 666-673, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-31833801

RESUMEN

Background: The aim was to assess the safety and tolerability of the insulin aspart biosimilar/follow-on product SAR341402 (100 U/mL solution; SAR-Asp) and originator insulin aspart (100 U/mL; NN-Asp; NovoLog®) self-administered through an insulin pump. Materials and Methods: This randomized, open-label, 2 × 4-week crossover study enrolled 45 adults with type 1 diabetes (T1D). Participants were randomized 1:1 to the treatment sequence SAR-Asp/NN-Asp or NN-Asp/SAR-Asp. The basal and prandial insulin doses were individually titrated. The primary outcome was the number of participants with at least one infusion set occlusion (infusion set change due to failure-to-correct hyperglycemia [plasma glucose ≥250 mg/dL] by insulin pump bolus) during the 4-week treatment. The main secondary outcome was the number of participants with at least one episode of unexplained hyperglycemia (regardless of correction by an insulin pump bolus without apparent material defect, medical, dietary, insulin dosing reason, or pump problem). Results: The number of participants reporting ≥1 infusion set occlusion were similar between treatments: 14/43 on SAR-Asp (33 events) and 12/43 on NN-Asp (24 events). The estimated difference in infusion set occlusion risk for SAR-Asp versus NN-Asp was 4.1% (95% confidence interval: -9.3% to 17.4%). The number of participants with ≥1 episode of unexplained hyperglycemia was similar between treatments (31/43 on SAR-Asp [154 events]; 32/43 on NN-Asp [175 events]). Hypoglycemia, treatment-emergent adverse events, hypersensitivity, and injection site reactions were similar between treatments. Conclusions: SAR-Asp and NN-Asp were well tolerated and had similar infusion set occlusions over a 4-week period in insulin pump users with T1D.


Asunto(s)
Biosimilares Farmacéuticos/uso terapéutico , Diabetes Mellitus Tipo 1 , Hipoglucemiantes/uso terapéutico , Insulina Aspart/uso terapéutico , Adulto , Anciano , Biosimilares Farmacéuticos/efectos adversos , Glucemia , Estudios Cruzados , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Humanos , Hipoglucemiantes/efectos adversos , Insulina Aspart/efectos adversos , Sistemas de Infusión de Insulina , Masculino , Persona de Mediana Edad
7.
J Diabetes Sci Technol ; 12(3): 680-686, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29359575

RESUMEN

BACKGROUND: SAR342434 (U100; SAR-Lis; insulin lispro) is a biosimilar/follow-on to insulin lispro (U100; Ly-Lis). Similar pharmacokinetics/pharmacodynamics between the two products has been demonstrated in a hyperinsulinemic euglycemic clamp study. The current study evaluated the safety of SAR-Lis and Ly-Lis when administered by continuous subcutaneous insulin infusion (CSII; insulin pumps). METHODS: This was a randomized, open-label, 2 × 4-week, two-arm crossover study in 27 patients with type 1 diabetes mellitus (NCT02603510). The main outcome was the incidence of infusion set occlusions (ISOs), defined as failure to correct hyperglycemia (plasma glucose ≥≥ 300 mg/dl) by 50 mg/dl within 60 minutes by insulin bolus via the pump. Secondary outcomes included intervals between infusion set changes, treatment-emergent adverse events (TEAEs) including infusion site, hypersensitivity reactions and hypoglycemic events, and safety. RESULTS: The number of patients reporting at least one ISO was small: 6/25 patients on SAR-Lis reported 14 ISOs and 4/27 on Ly-Lis reported nine ISOs. The estimated difference in ISO risk for SAR-Lis versus Ly-Lis was 7.9% (95% CI, -1.90 to 17.73). Mean interval between infusion set changes for any reason was similar with SAR-Lis (3.09 days) and Ly-Lis (2.95 days). The event rate (events/patient-month) of any hypoglycemia was similar with SAR-Lis (7.15) and Ly-Lis (7.98), as was the percentage of patients who experienced any TEAE (12.0% and 14.8%). CONCLUSION: Both SAR-Lis and Ly-Lis were well tolerated by patients using insulin pumps. The results do not suggest a clinically significant difference in the risk of ISO between SAR-Lis and Ly-Lis when used in CSII.


Asunto(s)
Biosimilares Farmacéuticos/administración & dosificación , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina/efectos adversos , Insulina Lispro/administración & dosificación , Adulto , Anciano , Estudios Cruzados , Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad
8.
Diabetes Obes Metab ; 19(5): 622-627, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-27987252

RESUMEN

AIM: To compare the pharmacokinetics (PK) and pharmacodynamics (PD) of 3 rapid-acting insulin lispro products: SAR342434 solution, United States (US)-approved Humalog and European Union (EU)-approved Humalog. METHODS: In a single-centre, randomized, double-blind, 3-treatment, 3-period, 6-sequence, crossover, euglycaemic clamp study (NCT02273258), adult male subjects with type 1 diabetes were randomized to receive 0.3 U/kg of SAR342434 solution, US-approved and EU-approved Humalog under fasted conditions. PK and PD (glucose infusion rate [GIR]) were assessed up to 12 hours. RESULTS: Of the 30 subjects randomized, 28 completed all 3 treatment periods. Mean concentration and GIR vs time profiles were similar for all 3 products. Exposure (INS-Cmax , INS-AUClast and INS-AUC) and activity (GIRmax and GIR-AUC0-12h ) of SAR342434, US-approved and EU-approved Humalog were similar in all comparisons (point estimates of treatment ratios, 0.95-1.03 for PK parameters and 1.00-1.07 for PD parameters), with 90% confidence intervals for the ratios of geometric least squares means within the pre-specified bioequivalence limit (0.80-1.25) and no significant differences in time-related parameters. Within-subject variability of exposure and activity was low across the 3 clamps, indicating high day-to-day reproducibility in clamp performance, irrespective of the individual product. Adverse events were similar for all 3 products. No safety concerns were noted in vital signs or in laboratory and electrocardiogram data. CONCLUSIONS: The results of this study demonstrate similarity in insulin lispro exposure profiles and PD activity of SAR342434 solution to both US- and EU-approved Humalog, and between both US- and EU-approved Humalog, supporting the use of SAR342434 solution for injection as a follow-on product.


Asunto(s)
Biosimilares Farmacéuticos/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hiperglucemia/prevención & control , Hipoglucemia/prevención & control , Hipoglucemiantes/uso terapéutico , Insulina Lispro/uso terapéutico , Adulto , Biosimilares Farmacéuticos/efectos adversos , Biosimilares Farmacéuticos/sangre , Biosimilares Farmacéuticos/farmacocinética , Estudios Cruzados , Diabetes Mellitus Tipo 1/sangre , Método Doble Ciego , Aprobación de Drogas , Unión Europea , Alemania/epidemiología , Técnica de Clampeo de la Glucosa , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Hipoglucemiantes/efectos adversos , Hipoglucemiantes/sangre , Hipoglucemiantes/farmacocinética , Incidencia , Insulina Lispro/efectos adversos , Insulina Lispro/sangre , Insulina Lispro/farmacocinética , Masculino , Persona de Mediana Edad , Proteínas Recombinantes/efectos adversos , Proteínas Recombinantes/sangre , Proteínas Recombinantes/farmacocinética , Proteínas Recombinantes/uso terapéutico , Estados Unidos , Adulto Joven
9.
J Diabetes Sci Technol ; 11(2): 263-269, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27664062

RESUMEN

BACKGROUND: Insulin glargine 300 U/mL (Gla-300) contains the same active ingredient as glargine 100 U/mL (Gla-100), and provides the same number of units in one-third of the volume. The SoloSTAR® injector pen has been modified to ensure accurate administration of this reduced volume and to improve user experience. METHODS: Insulin- and pen-naïve adults with type 2 diabetes (T2DM) inadequately controlled with oral antihyperglycemic drugs, who had glycated hemoglobin (HbA1c) levels of 7.0-11.0 % (53-97 mmol/mol) were studied. They received once-daily Gla-300 in this 4-week, multicenter, open-label, single-arm study (NCT02227212). Ease of use/ease of learning (the primary endpoint), glycemic control, safety, and reliability of the disposable (prefilled) Gla-300 injector pen (secondary endpoints) were evaluated. RESULTS: At week 4, 95.0% of 40 participating subjects assessed the pen as excellent/good and none as poor/very poor; 97.5% would recommend it to others. Total Diabetes Treatment Satisfaction Questionnaire scores were stable throughout the study. Mean (SD) fasting plasma glucose levels decreased from 166.1 (35.0) mg/dL at baseline to 124.2 (41.1) mg/dL at week 4. No product technical complaints (PTCs) or adverse events (AEs) related to PTCs were reported. The number of subjects experiencing hypoglycemic events of any kind and the incidence of AEs were low. No serious AEs were reported. CONCLUSIONS: The Gla-300 injector pen is easy to use and easy to learn to use, with demonstrable reliability and high degrees of acceptance and treatment satisfaction. Once-daily Gla-300 basal insulin treatment was well tolerated and effective in pen- and insulin-naïve adult T2DM subjects.


Asunto(s)
Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Insulina Glargina/administración & dosificación , Anciano , Equipos Desechables , Femenino , Humanos , Inyecciones Subcutáneas , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Jeringas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...